DC Breaker Pakistan 2026: Solar Battery Inverter
-
DC 1P MCB 500V 125A YCB1 | Reliable Protection
- Rs.1,150
Rs.1,300- Rs.1,150
- Unit price
- per
CNC YCB8s-125PV DC 1 Pole MCB -- 500V 125A A single-pole DC miniature circuit breaker rated at 500V and 125A, built specifically for photovoltaic and battery protection. This is the breaker you need when running high-current DC strings or battery bank feeds in solar...- Rs.1,150
Rs.1,300- Rs.1,150
- Unit price
- per
-
DC 2 Pole MCB 500V | Solar PV Breaker
- Rs.1,600
Rs.1,800- Rs.1,600
- Unit price
- per
DC 2 Pole MCB 500V is the core safety breaker used on the DC side of solar systems to disconnect and protect strings from overcurrent and short-circuit faults. The CNC Electric YCB8-63PV is built for solar PV use, DIN-rail mounting, and comes in 4...- Rs.1,600
Rs.1,800- Rs.1,600
- Unit price
- per
-
DC 2 Pole MCB 500V 125A | for Battery Protection
- Rs.2,500
Rs.2,800- Rs.2,500
- Unit price
- per
Battery breaker buyers in Pakistan choose the DC 2 Pole 500V 125A Battery Breaker YCB1-125 when they need high-current DC battery breaker performance for real installations rather than improvised solutions. Starting from Rs.2,500, this product suits everyday use cases such as AC lines, geysers,...- Rs.2,500
Rs.2,800- Rs.2,500
- Unit price
- per
-
DC 4 Pole MCB 1000V | Solar PV Breaker
- Rs.3,400
Rs.3,700- Rs.3,400
- Unit price
- per
DC MCB 4 pole 1000V price in Pakistan matters when a solar installer needs a breaker that actually matches DC string voltage instead of a normal AC breaker forced into a PV job. This CNC Electric listing is sold locally from Rs.3,300 with selectable...- Rs.3,400
Rs.3,700- Rs.3,400
- Unit price
- per
-
DC 4 Pole MCB 1500V | Solar PV Breaker
- Rs.3,800
Rs.4,220- Rs.3,800
- Unit price
- per
DC MCB 4 pole 1500V is used where a solar DC circuit needs compact overcurrent protection instead of a larger MCCB. This 32A model is listed at Rs.3,800 on CNC Electric Pakistan. It suits PV strings, combiner boxes, battery-linked DC boards, and other high-voltage...- Rs.3,800
Rs.4,220- Rs.3,800
- Unit price
- per
Updated: May 2026 · CNC Electric Pakistan
DC Breaker (DC MCB) — Pakistan Quick Answer (May 2026)
A DC breaker in Pakistan (commonly DC MCB) protects solar PV strings, battery banks, and EV charger circuits from overload and short circuit at 500V / 1000V / 1500V DC. Unlike AC MCBs, DC breakers use magnetic arc-quenching (no zero-crossing) and are polarity-marked (+/−). CNC 2026 prices range from Rs. 650 (2P 500V 16A YCB8-63PV) for small home solar to Rs. 3,200 (4P 1500V 63A YCB8s) for industrial PV plants.
| Solar System | Recommended DC MCB | CNC Model | 2026 PKR |
|---|---|---|---|
| 1–3 kW rooftop (24V / 48V battery) | 2P 500V 16A Curve C | YCB8-63PV 2P 16A 500V | 650 |
| 3–5 kW hybrid (96V battery) | 2P 1000V 25A Curve C | YCB8-63PV 2P 25A 1000V | 950 |
| 5–10 kW on-grid solar | 2P 1000V 32A Curve K | YCB8-63PV 2P 32A 1000V K | 1,150 |
| 10–15 kW hybrid (multi-string) | 2P 1000V 63A Curve K | YCB8-63PV 2P 63A 1000V | 1,650 |
| 15–30 kW commercial 3-string | 3P 1000V 40A | YCB8-63PV 3P 40A 1000V | 2,200 |
| Industrial PV 1500V | 4P 1500V 63A | YCB8s 4P 63A 1500V | 3,200 |
Voltage sizing rule: DC MCB Uc must be ≥ PV string Voc. 8 panels series ≈ 350V → use 500V. 15-20 panels series ≈ 700V → use 1000V. Industrial strings ≈ 1100V → use 1500V.
Read also: DC Surge Protection (SPD) · DC Fuses · DC Isolators
Why You Cannot Use an AC MCB on Solar DC
An AC MCB extinguishes the arc using the natural zero-crossing of 50 Hz AC current (200 times per second). DC current never crosses zero — so an AC MCB cannot interrupt a DC fault. The arc continues burning until the breaker melts, often causing fire in solar combiner boxes.
DC MCBs use a permanent magnet inside the arc chamber to stretch and cool the DC arc until it extinguishes. They are also polarity-marked (+ and − terminals) — install reverse-polarity and the magnetic blow-out fails.
Pole Count for Solar — 2P vs 3P vs 4P
| Poles | Configuration | Use For |
|---|---|---|
| 2P (DC+, DC-) | Single string, floating ground | Most Pakistani residential rooftop solar |
| 3P (DC+, DC-, PE) | Grounded PV with earth-fault detection | Commercial PV with negative grounding |
| 4P (multi-string) | Two strings + PE per breaker | Industrial PV combiner boxes |
Trip Curve — B, C, or K for Solar?
Solar DC has constant current (no inrush like a motor). The trip curve choice is less critical than for AC. Curve C is standard for solar DC MCBs. Curve K trips slightly slower (8-14× rated current) and is used when you want to ride through brief MPPT search-current spikes. Curve B is rarely needed for solar.
DC Breaker FAQ — Pakistan
Q1: What is the price of a DC breaker in Pakistan?
CNC DC breaker (DC MCB) prices in 2026 start at Rs. 650 for a 2P 16A 500V YCB8-63PV (1-3 kW solar) and go up to Rs. 3,200 for a 4P 63A 1500V YCB8s (industrial PV). Most popular for 5 kW Pakistani solar is 2P 25A 1000V at Rs. 950.
Q2: Can I use an AC MCB for solar DC?
No — never. AC MCBs cannot extinguish DC arcs (no zero-crossing). The arc continues burning, melts the breaker, often causes fire. Always use a DC-rated MCB with the polarity marking matched correctly.
Q3: How do I size a DC MCB for my solar string?
Three rules: (1) DC MCB Uc voltage ≥ PV string Voc, (2) DC MCB amp rating = 1.25 × Isc of PV string, (3) Pick Curve C for standard solar (or K for grid-tied inverters with MPPT inrush).
Q4: 2-pole or 4-pole DC MCB for residential solar?
For single PV string (1 array, 1 inverter): 2-pole (DC+ and DC−). For multi-string commercial arrays: 4-pole. Most Pakistani 1-15 kW rooftop solar uses 2-pole 500V or 1000V.
Q5: Is CNC DC MCB PSQCA certified?
Yes. All CNC YCB8-63PV and YCB8s series DC MCBs carry IEC 60947-2 compliance and PSQCA approval. Verify holographic sticker on side of unit.
Q6: What is the difference between YCB8-63PV and YCB8s?
YCB8-63PV: rated for 500V / 1000V DC (residential and commercial solar up to 10 kW). YCB8s: rated for 1500V DC (industrial PV plants, utility-scale solar). Both are polarity-marked, magnetic arc-quench design.
Q7: What warranty does CNC offer?
1-year manufacturer warranty on DC MCBs. Replacement at CNC service centre, College Road, Township, Lahore within 7 working days.
Protect your DC circuits from overloads and short circuits with high-quality DC Breakers from cncelectric.pk. Ideal for solar power systems, industrial DC panels, battery banks, and sensitive electronic devices, our DC breakers ensure maximum safety, reliable performance, and uninterrupted operation.
Key Features of DC Breakers
- Overload & Short Circuit Protection: Instantly trips during abnormal current conditions, safeguarding your devices.
- Durable & Reliable: Made with premium materials to ensure long-lasting performance.
- Fast Response Time: Quick disconnection prevents damage to inverters, batteries, and DC equipment.
- Versatile Applications: Suitable for solar systems, DC panels, battery banks, and industrial setups.
- Easy Installation: Compact design with user-friendly mounting options.
Why Choose CNCelectric.pk DC Breakers?
- Protects sensitive DC circuits and prevents costly equipment damage.
- Compatible with solar arrays, hybrid inverters, DC panels, and industrial machinery.
- High-quality construction ensures long-term durability and stable performance.
- Available at competitive DC breaker prices in Pakistan.
With CNCelectric.pk, you get trusted, tested, and efficient DC breakers that guarantee safe and stable operation of your electrical systems.
Frequently Asked Questions – DC Circuit Breakers
1. What is a DC circuit breaker?
A DC circuit breaker is a safety device designed to protect electrical circuits operating on direct current (DC). It automatically disconnects power during overloads or short circuits.
2. Where are DC circuit breakers commonly used?
- Solar power systems
- Battery banks
- DC panels
- Electric vehicles
- Telecom systems
- Industrial DC applications
3. What is the difference between AC and DC circuit breakers?
- DC breakers are designed to handle continuous current and higher arc energy.
- AC breakers are used only for alternating current systems.
Using an AC breaker in a DC system is unsafe and not recommended.
4. Why is a special breaker required for DC systems?
DC current does not naturally cross zero like AC, making arc suppression difficult. DC breakers are specially engineered to safely interrupt DC current.
5. What ratings should I check before buying a DC breaker?
- Voltage rating (DC)
- Current rating (Amps)
- Number of poles
- Application type (solar, battery, industrial)
6. Are DC breakers suitable for solar systems?
Yes, DC breakers are essential for solar installations. They protect panels, charge controllers, inverters, and batteries.
7. Can DC circuit breakers be reused after tripping?
Yes, most DC circuit breakers are resettable and can be reused after the fault is resolved.
8. What is the difference between DC MCB and DC MCCB?
- DC MCB: Used for low current and small solar or residential systems.
- DC MCCB: Used for higher current industrial and commercial applications.
9. How do I choose the right DC breaker?
Choose a DC breaker based on system voltage, load current, and application requirements. Always select certified and properly rated products.
10. Do DC circuit breakers improve system safety?
- Prevents fire hazards
- Protects expensive equipment
- Ensures reliable and stable operation
📖 Related Guide: Types of Circuit Breakers
📖 Related Guide: Breaker Price List Pakistan
Solar Bundles: On-Grid Solar DB Bundles →
Solar Bundles: Hybrid Solar DB Bundles →
Tools: Build Your Custom Solar DB Bundle →
Frequently Asked Questions
Can I use a 1P or 2P WiFi breaker on a 3-phase circuit?
No. For a true 3-phase load you must use a 4P or minimum 3P breaker. Using a single-pole breaker on one phase is dangerous because the other two phases stay live.
Is a 3P breaker enough or do I need 4P?
3P is enough for pure 3-phase loads like isolated motors. For mixed loads, building mains, solar outputs, or TN-C-S earthing, use 4P for full isolation.
What's the maximum amp rating for a 3-phase WiFi breaker in Pakistan?
CNC 4P WiFi breakers go up to 100A. Above that you move to MCCB class with a separate smart controller.
Can I use a 3-phase WiFi breaker with a single-phase pump?
Technically yes but wasteful. Single-phase pumps should use 2P WiFi breakers. Use 4P only when the pump itself is 3-phase.
Does the 4G backup version work in rural Pakistan?
Yes, with any standard 4G data SIM from Jazz, Zong, Ufone, or Telenor. The breaker uses cellular as a fallback when WiFi is down.
Can I monitor individual phases separately?
Yes. CNC 4P WiFi breakers expose per-phase voltage, current, and power draw in the Tuya Smart app.










