Changeover Switch Price Pakistan 2026
-
1 Pole Changeover Switch 63A | DIN Rail
- Rs.600
Rs.700- Rs.600
- Unit price
- per
Not sure which voltage protector you need? Try our VA Protector Product Finder Tool — Pakistan's first interactive selector. Changeover switch is the practical manual solution for selecting between two power sources such as WAPDA and generator on small single-phase circuits. The CNC Electric...- Rs.600
Rs.700- Rs.600
- Unit price
- per
-
2 Pole Changeover Switch 63A,100A | DIN Rail
- Rs.1,500
Rs.1,700- Rs.1,500
- Unit price
- per
Not sure which voltage protector you need? Try our VA Protector Product Finder Tool — Pakistan's first interactive selector. Changeover switch 2 pole 63A is the most common and most practical manual source selector for Pakistani homes because it switches both phase and neutral...- Rs.1,500
Rs.1,700- Rs.1,500
- Unit price
- per
-
AC 3P Changeover Breaker Din Rail 63A - YCBZ
- Rs.1,900
Rs.2,100- Rs.1,900
- Unit price
- per
A 3 pole changeover breaker is the practical answer when you need manual source selection in a three-phase panel without moving to a larger plate-mounted switch or a costlier ATS. This CNC Electric listing is tracked in the project product data at Rs.1,500 for...- Rs.1,900
Rs.2,100- Rs.1,900
- Unit price
- per
-
AC 4P Changeover Breaker Din Rail 63A, 100A, 125A - YCBZ
- Rs.2,500
Rs.2,750- Rs.2,500
- Unit price
- per
This 4 pole changeover breaker gives manual source transfer inside the panel without moving to a large external rotary switch or an automatic ATS. Available in 63A, 100A, and 125A, it fits mains-to-generator, mains-to-inverter, and source-selection boards where the operator wants a clean DIN...- Rs.2,500
Rs.2,750- Rs.2,500
- Unit price
- per
Updated: May 2026 · CNC Electric Pakistan
Changeover Switch — Pakistan Quick Answer (May 2026)
A changeover switch in Pakistan transfers your electrical load between two power sources — typically WAPDA / K-Electric mains and a backup generator or solar inverter. Manual changeover requires you to flip a handle (10–60 seconds), while automatic changeover (ATS) does it itself in 50–200 milliseconds. Current CNC 2026 PKR prices: manual from Rs. 1,800 (2P 63A) to Rs. 18,500 (4P 250A); automatic from Rs. 6,200 (2P 63A) to Rs. 89,000 (4P 630A).
| Setup | Recommended Type | CNC Model | 2026 Price (PKR) |
|---|---|---|---|
| Manual-start generator, 5–10 kVA | Manual changeover 2P 63A | YCBZ-63 2P | 1,800–3,500 |
| Manual-start generator, 3-phase | Manual changeover 4P 63A | YCBZ-63 4P | 3,800–5,800 |
| Auto-start generator, single-phase | Automatic changeover (ATS) 2P 63A | YCQR / YCQ4 2P 63A | 6,200–6,700 |
| Auto-start generator, 3-phase | Automatic changeover (ATS) 4P 100A | YCQ4 4P 100A | 7,200 |
| Solar DC switching | PV-rated DC ATS | YCQ4 DC 2P 500V 100A | 7,300 |
| Industrial 3-phase, 100–300 kVA | Heavy-duty ATS 4P 200–630A | YCS1 4P 200–630A | 18,500–89,000 |
Quick decision: If your generator starts itself (AMF panel), buy automatic changeover. If you start the generator manually, buy manual changeover — saves Rs. 4,000–5,000 with no functional loss. ✅ All CNC switches: 1-year warranty · IEC 60947 compliant · PSQCA-approved.
Read also: Automatic Changeover Switch Price Guide 2026 · ATS Buyer's Guide 2026
Changeover Switch Price in Pakistan 2026 — Buyer's Guide
A changeover switch — also called a changeover breaker, transfer switch, or generator switch — physically transfers your home or business load between two power sources (WAPDA mains and a generator, or grid and solar inverter). In Pakistan's reality of daily load-shedding and net-metering, it is the single most important switching device in any backup setup. CNC Electric stocks the YCBZ-63 series in 1-pole, 2-pole, 3-pole and 4-pole configurations from 63 A to 125 A, priced from Rs. 600.
Every CNC changeover switch is built on DIN-rail breaker housings with full mechanical interlock (so both sources can never close at once), IEC 60947-3 compliance, and a 5-year warranty. Stocked locally in Lahore with same-day dispatch nationwide.
CNC Changeover Switch Price Table — Pakistan 2026
| Model | Poles | Rating | Use Case | Price (PKR) |
|---|---|---|---|---|
| YCBZ-63 1P 63 A | 1 Pole | 63 A | Single live, common neutral (DIY home backup) | Rs. 600 |
| YCBZ-63 2P 63 A | 2 Pole | 63 A | Single phase home / shop (live + neutral switching) | Rs. 1,500 |
| YCBZ-63 2P 100 A | 2 Pole | 100 A | Larger single phase home (≥ 15 kW) | Rs. 4,000 |
| YCBZ-63 3P 63 A | 3 Pole | 63 A | 3-phase without neutral switching | Rs. 1,900 |
| YCBZ-63 4P 63 A | 4 Pole | 63 A | Full 3-phase + neutral (commercial / factory) | Rs. 2,500 |
| YCBZ-63 4P 100 A | 4 Pole | 100 A | Factory main, large solar hybrid | Rs. 5,500 |
| YCBZ-63 4P 125 A | 4 Pole | 125 A | Industrial main panel | Rs. 8,500 |
Free delivery across Pakistan. 5-year warranty. Bulk & dealer pricing — WhatsApp +92 326 1111376.
Looking for the fully automatic version (Automatic Transfer Switch)? See CNC ATS — Automatic Transfer Switch instead.
Manual vs Automatic Changeover Switch — Which One Do You Need?
This is the first decision. A manual changeover switch is a breaker-style toggle: you walk to the DB box and physically flip from mains to generator. An automatic changeover switch (ATS) senses power loss, signals the generator to start, and transfers the load — no human intervention.
| Feature | Manual Changeover | Automatic Transfer Switch (ATS) |
|---|---|---|
| Transfer trigger | Human operator | Voltage / frequency sensor |
| Transfer time | 10-30 seconds + walk time | 3-10 seconds (fully automatic) |
| Generator auto-start | No (manual start) | Yes (sends start signal) |
| Best for | Home, shop, manual genset | Auto-start genset, server room, hospital |
| Price range (Pakistan) | Rs. 600 – 8,500 | Rs. 18,000 – 90,000+ |
| Maintenance | None (mechanical only) | Annual relay / sensor check |
For most Pakistani homes with a manual-start generator, the YCBZ-63 2P 63 A at Rs. 1,500 is the right answer. Step up to the 4-pole 100 A version if you have a 3-phase connection, or move to a full ATS if your generator has auto-start.
How a Changeover Switch Works
Inside a changeover switch are two ganged breakers connected by a mechanical interlock. Position A closes the mains side and opens the generator side. Position B does the opposite. The interlock physically prevents both sides from closing simultaneously — without this, you would back-feed the dead WAPDA line (a lineman-killer fault) or short the generator output against live mains.
The switch handles the switching, not the protection. You still need an MCB or MCCB upstream to handle overload and short-circuit faults. The changeover sits between two breaker banks: one for the WAPDA input, one for the generator input. This is why electricians refer to it as a "switching device, not protection device" — its only job is to route load to one source at a time, safely.
2-Pole vs 3-Pole vs 4-Pole — Picking the Right Configuration
1-Pole (Rs. 600): Switches only the live conductor. Neutral stays connected to one source permanently. Cheapest option but limited — never use where the neutral can rise above ground potential (i.e., never with portable inverter generators).
2-Pole (Rs. 1,500 – 4,000): Switches both live and neutral. Standard for single-phase home and shop installations. Buy this one unless you have a specific reason not to.
3-Pole (Rs. 1,900): Switches all three live phases. Common in older 3-phase industrial setups with a fixed common neutral. Cheaper than 4-pole but offers no neutral isolation between sources.
4-Pole (Rs. 2,500 – 8,500): Switches three live phases plus neutral. Required for any 3-phase installation with separately-derived neutrals — which means any installation where the generator's neutral is bonded to its own earth (almost all modern gensets). Also mandatory for TT and TN-S earthing systems per Pakistan Electrical Code.
Amperage Selection — 30 A, 63 A, 100 A, or 125 A?
Match the changeover switch rating to your main incoming breaker, not your generator. Here is the sizing matrix for typical Pakistani loads:
| Load | Typical kW | Recommended Changeover |
|---|---|---|
| 1-BR apartment, 1 AC | 3-5 kW | 30 A or 63 A (2P) |
| Home with 2-3 ACs, fridge, lights | 8-12 kW | 63 A 2P (Rs. 1,500) |
| Large home / villa | 15-20 kW | 100 A 2P (Rs. 4,000) or 4P |
| Small shop / office | 5-10 kW | 63 A 2P |
| Restaurant / mid-shop | 15-25 kW | 100 A 4P (Rs. 5,500) |
| Factory / industrial floor | 40-80 kW | 125 A 4P (Rs. 8,500) |
| Solar hybrid system (5-10 kW) | 5-10 kW | 63 A 2P or 4P |
If your generator is much smaller than your mains breaker (e.g., 3 kW genset on a 20 kW mains), size the changeover to the larger of the two — so it can handle full mains current when on grid.
Changeover Switch vs ATS — When Each Is Right
The terminology overlaps confusingly in Pakistan. Clarifying:
- Changeover switch / changeover breaker: Manual, breaker-style, mechanical interlock. Rs. 600 – 8,500.
- Automatic changeover switch: Same form factor but with internal contactor + control board. Rs. 18,000 – 40,000.
- ATS (Automatic Transfer Switch): Full panel-mount unit with voltage sensing, gen-start signal, and time delays. Rs. 30,000 – 90,000.
Use a manual changeover if your generator is started by hand (pulling a cord or pressing a starter button). Use an automatic version (ATS) if your generator has an auto-start panel, or if you need transfer during off-hours when nobody can flip a switch. Hospitals, server rooms, and 24-hour factories always need ATS; homes and shops rarely do. Browse CNC ATS Switches for the auto-start range.
Where to Install Your Changeover Switch
Home (single-phase): Mount the YCBZ-63 2P 63 A in the main DB box, downstream of the WAPDA main MCB and the generator output MCB. Both inputs feed the changeover, output goes to the home distribution bus.
Commercial / shop: Same configuration but typically 100 A 2-pole. Mount in the main panel; ensure adequate cabling on both sides (≥ 25 mm² copper for 100 A).
3-phase factory: YCBZ-63 4-pole 100-125 A at the main panel. Always switch neutral. Lock-off facility recommended for maintenance isolation.
Solar hybrid: Mount on the AC output side of the inverter, between inverter output and home bus, so you can manually bypass to WAPDA in case of inverter fault. Or on the inverter input side if you want hard isolation between grid and inverter.
Top Picks by Use Case
Best for Home with One AC: YCBZ-63 1P 63 A. Rs. 600 — cheapest entry point if you only need live-side switching. View product →
Best Value (Home / Shop, Single Phase): YCBZ-63 2P 63 A. Rs. 1,500 — the right answer for 80% of installations. Live + neutral switching, 63 A handles most home loads. View product →
Best for Larger Homes: YCBZ-63 2P 100 A. Rs. 4,000 — for homes with 3+ ACs or solar hybrid. View product →
Best for 3-Phase Without Neutral: YCBZ-63 3P 63 A. Rs. 1,900 — older industrial setups. View product →
Best for Factory: YCBZ-63 4P 100 A or 125 A. Rs. 5,500 – 8,500. Full 3-phase + neutral, IEC 60947-3 compliant. View product →
CNC vs Clopal vs Opas vs Millat — Brand Comparison
| Brand | Origin | Warranty | 4-Pole Range | Mechanical Interlock | Price for 63 A 2P |
|---|---|---|---|---|---|
| CNC | Imported, PK-stocked | 5 years | 63-125 A | Yes (gang-tied) | Rs. 1,500 |
| Clopal | Local brand | 1 year | 63-100 A | Yes | Rs. 1,300 – 1,800 |
| Opas | Local brand | 1 year | 63-100 A | Yes | Rs. 1,400 – 2,000 |
| Millat (Milat) | Pakistan-manufactured | 1 year | 32-100 A (rotary) | Rotary cam | Rs. 1,200 – 1,700 |
| Schneider | Imported premium | 2 years | 40-160 A | Yes | Rs. 6,500 – 12,000 |
CNC offers the longest warranty (5 years) in the value tier. Millat (rotary cam-style) is the cheapest local option but uses a rotary mechanism rather than the breaker-style design, which makes service replacement more complex. Schneider is premium but 4-5× the price.
Types of Changeover Switch
1. Breaker-type (DIN-rail): Two MCB-style breakers ganged together with mechanical interlock. CNC YCBZ-63 series. Compact, DB-box friendly, easy to replace.
2. Rotary cam: Single body with a rotary handle that moves contacts between three positions (mains, off, generator). Common in Millat, Opas. Bulkier but visible position indication.
3. Knife-switch: Older industrial double-throw knife switches with bare blades. Largely obsolete for safety reasons; still found in legacy installations.
4. Automatic (ATS): Adds voltage sensing, time delays, and a contactor. See CNC ATS range.
5. Solar/hybrid changeover: Identical to breaker-type but rated for DC operation in some inverter-input configurations. Use AC-rated changeovers (YCBZ-63 series) for AC-side switching only.
Installation Wiring — Single-Phase Home
- Switch OFF both the WAPDA main MCB and the generator output MCB.
- Mount the YCBZ-63 2P on the DIN rail of the main DB box, between the two input MCBs and the home distribution bus.
- Wire the WAPDA Live + Neutral to the top-left input pair. Wire the Generator Live + Neutral to the top-right input pair.
- Wire the output Live + Neutral (bottom terminals) to the home distribution bus.
- Confirm the toggle handle has clearly labelled positions (MAINS / OFF / GEN).
- Restore the WAPDA main MCB. With the changeover in MAINS position, verify home power. Switch the changeover to GEN position — home power should drop. Start the generator and verify home power returns when in GEN position.
- Always return to MAINS position when the generator is off, so the system is ready for the next outage.
For 3-phase installations, the wiring follows the same pattern with three lives plus neutral (4-pole) or three lives only (3-pole).
Bulk & Dealer Pricing
CNC YCBZ-63 changeover switches are stocked locally in Lahore with same-day dispatch to Karachi, Islamabad, Faisalabad, Multan, Peshawar, and Quetta. Bulk pricing (10+ units) and dealer / contractor rates available. Solar installer bundles (changeover + DC breaker + SPD + voltage protector) priced separately. WhatsApp +92 326 1111376 with your project requirement.
Frequently Asked Questions — Changeover Switch Pakistan
What is a changeover switch?
A changeover switch is an electrical device that physically transfers a load between two power sources — typically WAPDA mains and a generator — with a mechanical interlock that prevents both sources from being connected at the same time.
What is the difference between a changeover switch and an ATS?
A changeover switch is operated manually (a person flips the handle). An ATS (Automatic Transfer Switch) detects power loss automatically and transfers the load without human intervention, usually also signalling the generator to start. Changeover switches are cheaper (Rs. 600 – 8,500); ATS units cost Rs. 18,000 – 90,000.
What size changeover switch do I need for my home?
For most single-phase Pakistani homes (8-12 kW load, 2-3 ACs), a 63 A 2-pole changeover is sufficient. For larger homes with 3+ ACs or solar hybrid systems, use the 100 A 2-pole or 4-pole. Match the changeover rating to your main WAPDA breaker, not your generator.
What is the price of a changeover switch in Pakistan?
CNC changeover switches range from Rs. 600 (1-pole 63 A) to Rs. 8,500 (4-pole 125 A). The most common size — 2-pole 63 A for home / shop use — is Rs. 1,500. All units include a 5-year warranty and free delivery across Pakistan.
Should I buy a 2-pole, 3-pole or 4-pole changeover?
For single-phase (one live + neutral), use 2-pole. For 3-phase with shared neutral, use 3-pole. For modern 3-phase with separately-derived neutrals (most installations today), use 4-pole. When in doubt on 3-phase, go 4-pole — it is always safe and code-compliant.
Can a changeover switch be used with a generator?
Yes — that is its primary use. The changeover sits between your mains supply and your generator output, routing power to your home from one or the other. The mechanical interlock prevents back-feeding into the WAPDA line, which is required by code for lineman safety.
Can a changeover switch be used with solar?
Yes. Mount on the AC output side of the hybrid inverter, between inverter and home bus, so you can manually bypass to WAPDA if the inverter faults. Or on the input side to physically isolate inverter from grid. Use the standard AC-rated YCBZ-63 series — do not use AC changeovers for DC operation between solar panels.
Is a changeover switch the same as a circuit breaker?
No. A changeover switches between two sources; a circuit breaker protects against overload and short-circuit. A changeover switch does not provide protection — you still need an MCB or MCCB upstream of each input. Some YCBZ-63 units include thermal-magnetic protection internally as a bonus, but rely on the upstream breaker for primary protection.
How long does a changeover switch last?
Mechanical life is typically 10,000-30,000 operations for breaker-type changeovers per IEC 60947-3. At 2-3 changeovers per day during heavy load-shedding, that is 10+ years of service. CNC ships with a 5-year warranty — longest in the value tier.
Can I install a changeover switch myself?
Wiring a changeover switch involves connecting two live power sources. Always hire a licensed electrician unless you are qualified for high-voltage work. Failures here can back-feed live WAPDA lines (lineman injury), short the generator against mains (genset destruction), or leave the system permanently miswired. Cost of installation is Rs. 1,500 – 3,000 — well worth it.
More CNC Electric Buyer's Guides
- Voltage Protector vs Stabilizer 2026 — Which One Does Your Home Actually Need
- SPD Price in Pakistan 2026 — Surge Protection Device Buyer's Guide
- Electricity Meter Price in Pakistan 2026 — Digital, Smart & 3-Phase Buyer's Guide
- Magnetic Contactor Price in Pakistan 2026 — 12A-265A CJX2s Buyer's Guide
- Fire Extinguisher Price in Pakistan 2026 — ABC, CO2, Aerosol Buyer's Guide
- Net Metering Pakistan 2026 — Cost, NEPRA Rules & Solar Protection
- MCCB Breaker Price in Pakistan 2026 — MCB vs MCCB vs RCCB Buyer's Guide
- DC Breaker Price in Pakistan 2026 — Solar & Battery Buyer's Guide
- Solar DC Cable Price in Pakistan 2026 — 4mm & 6mm Buyer's Guide
- How to Choose a Voltage Protector / VA Protector — Selection Guide
- How to Wire SPD with Fuse + MCB + RCCB — Fire-Safe Surge Protection
- 1500V Industrial Solar Installation — DC Breaker, SPD, MCCB Sizing
- MCCB & ACB for Industrial Pakistan — Factory Switchgear
- MCB Wiring & Installation Guide — DB Box Layout, Torque
- AC Breaker for Air Conditioner — 1, 1.5, 2, 3 Ton Sizing
- Solar Combiner Box Wiring — DC Breaker, Fuse, SPD Step-by-Step
- EV Charger Pakistan 2026 — Home & Commercial Buyer's Guide
- CNC Industrial Range — Complete Factory Switchgear Roadmap
- Battery Bank Pakistan — LFP vs Lead-Acid Solar Battery Buyer's Guide
- Solar Inverter Pakistan — Hybrid, Grid-Tie, Off-Grid Selection
- MC4 Connectors Pakistan — Branded vs Generic, Crimping Guide
- PV String Sizing — Voc, Temperature Derating, Inverter Compatibility
- DC Fuse vs DC Breaker — Solar Strings, Batteries & SPD
- Off-Grid Solar System Design Pakistan — Complete Sizing Guide
- Why AC Breaker CANNOT Be Used on Solar — Physics & Risks
- CNC 1500V DC Solar Protection BOM — 100kW to 5MW
- 5 SPD Fire Case Studies Pakistan — Root Cause Analysis
Changeover Switch Selection Quick-Reference
| Type | Typical Use | Price (PKR) |
|---|---|---|
| Manual Lever 63A 4P | Home backup | Rs. 2,800 – 3,400 |
| Manual Rotary EP 100A 3P | Shop / clinic | Rs. 4,200 – 5,500 |
| MTS Inter-Lock 100A 4P | Small office | Rs. 6,800 – 8,500 |
| ATS Automatic 100A 4P | Critical loads | Rs. 35,000 – 48,000 |
| ATS Automatic 400A 4P | Industrial | Rs. 95,000 – 145,000 |
Full in-depth guide: Changeover Switch Pakistan 2026 — Manual vs Auto vs ATS — includes sizing formulas, wiring diagrams, FAQ and 2026 Pakistani pricing.
Changeover Switch Pakistan 2026 — Complete Range
CNC Electric stocks the full range of changeover switches for Pakistani homes, offices, shops, factories and solar installations — from cheap 2-pole manual lever switches for home generator backup, through 4-pole rotary EP switches for shop/clinic main panels, all the way up to fully automatic transfer switches (ATS) with 3-10 second auto-switching for critical loads. Every unit IEC 60947-3 certified, 5-year warranty.
Complete Changeover Switch Type + Price Reference
| Type | Rating | Typical Use | Price (PKR) |
|---|---|---|---|
| Manual Lever 2P 63A YCBZ | 230V single-phase | Home WAPDA ↔ generator backup | Rs. 1,700 – 2,400 |
| Manual Lever 4P 63A YCBZ | 400V 3-phase + neutral | Small office, clinic | Rs. 2,800 – 3,400 |
| Manual Lever 4P 100A | 400V 100A | Medium shop, restaurant | Rs. 4,500 – 5,500 |
| Rotary EP 2P 63A | 230V single-phase | Clean panel aesthetics | Rs. 1,700 – 2,200 |
| Rotary EP 4P 100A | 400V 100A | Industrial panel | Rs. 5,500 – 7,200 |
| Rotary EP 4P 250A | 400V 250A | Factory section panel | Rs. 8,500 – 11,500 |
| Rotary EP 4P 400A | 400V 400A | Factory main | Rs. 13,500 – 17,500 |
| MTS Inter-Lock 100A 4P | 400V 100A break-before-make | Office with critical UPS | Rs. 6,800 – 8,500 |
| ATS Automatic 63A 4P | 3-10 sec auto-transfer | Home with always-on backup | Rs. 12,500 – 18,500 |
| ATS Automatic 100A 4P | 3-10 sec auto-transfer | Small clinic, ATM, fuel pump | Rs. 35,000 – 48,000 |
| ATS Automatic 250A 4P | 3-10 sec auto-transfer | Hospital, data center, telecom | Rs. 65,000 – 95,000 |
| ATS Automatic 400A 4P | 3-10 sec auto-transfer | Factory main with generator | Rs. 95,000 – 145,000 |
Manual vs Automatic — Decision Guide
| Use Manual If… | Use Automatic If… |
|---|---|
| Someone always home to flip the lever within 5-30 min of outage | Unattended site (fuel pump, ATM, server room, factory off-shift) |
| Cost-sensitive; saves 70-80% vs ATS | Critical loads (medical, IT, security) |
| Generator is manual-start anyway | Auto-start generator already installed |
| Backup power tolerance ≥ 30 min | Need backup power within 10-30 seconds |
Why Buy Changeover Switches From CNC Electric Pakistan
- Single trusted brand: every changeover is genuine CNC, IEC 60947-3 certified, no counterfeit risk vs mixed-brand aggregators.
- 5-year warranty from Lahore stock: faulty unit replaced within 72 hours, no China RMA delays.
- Sizing engineering support: WhatsApp our team with your generator kVA + load list, get the right rating recommendation.
- Bulk dealer pricing: 10+ unit orders get 8-12% discount automatically.
- ATS bundle pricing: pre-packaged ATS + voltage protector + DB bundles save 15-20% vs separate.
In-Depth Buying Guides
Frequently Asked Questions
What is the price of a changeover switch in Pakistan in 2026?
CNC manual lever changeover starts at PKR 2,800, rotary EP at PKR 4,200, MTS inter-lock changeover at PKR 6,800, and automatic ATS at PKR 35,000.
Manual vs automatic changeover — which should I buy?
Manual is cheaper and reliable for occasional generator use. Automatic (ATS) is essential if you want hands-off transfer between grid, solar, and generator — especially useful when nobody is home to flip a switch.
What is the difference between a changeover and an ATS?
A changeover is a manual lever or rotary switch that you operate yourself. An ATS (automatic transfer switch) detects loss of mains and switches to the backup source automatically within 1–3 seconds.
What size changeover do I need for a 5 kW home?
Use a 4-pole 63A changeover for a typical 5 kW residential system. Size up to 100A if you have an EV charger or central AC on the same circuit.
Are CNC changeover switches IEC certified?
Yes — CNC changeover switches and ATS units meet IEC 60947-3 and IEC 60947-6-1 (for ATS). All units include a 5-year warranty.