CNC AC 4 Pole 385V 20KA-40KA, 40KA-60KA, 60KA-80KA Surge Protection Device YCS6 front view surge protection device Pakistan
CNC AC 4 Pole 385V 20KA-40KA, 40KA-60KA, 60KA-80KA Surge Protection Device YCS6 angled view surge protection device Pakistan
AC 4 Pole 385V 20KA-40KA, 40KA-60KA, 60KA-80KA Surge Protection Device YCS6 - CNC AC 4 Pole 385V 20KA-40KA, 40KA-60KA, 60KA-80KA Surge Protection Device YCS6 front view surge protection device Pakistan

AC 4 Pole 385V 20KA-40KA, 40KA-60KA, 60KA-80KA Surge Protection Device YCS6

Rs.5,500
Rs.5,900
Rs.5,500
Size And Voltage : In=20KA Imax=40KA 750V
Subtotal: Rs.5,500
CNC AC 4 Pole 385V 20KA-40KA, 40KA-60KA, 60KA-80KA Surge Protection Device YCS6 front view surge protection device Pakistan

AC 4 Pole 385V 20KA-40KA, 40KA-60KA, 60KA-80KA Surge Protection Device YCS6

Rs.5,900 Rs.5,500

AC 4 Pole 385V 20KA-40KA, 40KA-60KA, 60KA-80KA Surge Protection Device YCS6

Rs.5,900 Rs.5,500
Size And Voltage : In=20KA Imax=40KA 750V
Spare cartridge: for the 385V 20kA / 40kA version, use the AC SPD 385V Cartridge (20kA / 40kA). For the 440V versions, see the AC SPD 440V Cartridge and check the kA rating matches.
Always match the voltage and kA printed on your SPD before ordering. Not sure? WhatsApp 0326-1111376.

AC 4P SPD is the correct board-level surge protection format when the installation is 3-phase and the cost of downtime is higher than the cost of protection. The CNC YCS6 4-pole surge protection device is meant for 3-phase panels, industrial boards, lifts, commercial buildings, solar ACDBs and generator-related distribution where transient overvoltage can damage drives, relays, meters and control electronics.

Key Features and Specifications

Feature Details
Product type AC 4-pole surge protection device for 3-phase low-voltage systems
Series CNC YCS6
Best use Factory incomers, commercial boards, 3-phase ACDBs, lifts and machine panels
Voltage/capacity range 385V, 440V, 750V and higher discharge variants shown
Discharge options In 20kA / Imax 40kA, higher 40/60kA and 60/80kA options, plus 100kA 440V listing
Protection role Diverts transient surge energy before it reaches expensive three-phase equipment

Three-phase boards in Pakistan face more than simple overload risk. They carry VFDs, PLC panels, elevators, compressors, data-room air conditioning, textile auxiliaries and solar inverter outputs. One serious surge can damage more than one device at once.

A 4P SPD is not just a bigger 2P SPD.

Technical Specifications

Parameter Value
Series YCS6
Poles 4P
System type 3-phase AC low-voltage distribution and related panel protection
Rated frequency 50/60Hz
Network compatibility TT, IT, TN-S, TN-C and TN-C-S systems
Applicable standard IEC 61643-1
Options In 20kA / Imax 40kA at 385V, 440V and 750V
Higher options In 40kA / Imax 60kA at 440V, In 60kA / Imax 80kA at 440V, and 100kA 440V listing
Mounting DIN rail or panel rail installation inside 3-phase distribution board
Protection target Surges from lightning influence, switching events and utility disturbances
Panel coordination note Works best with short leads, proper earth bar layout and coordinated upstream protection

In 3-phase work, the bigger mistake is assuming an SPD is optional because “the board already has breakers.” Breakers do not respond to the same problem. MCBs and MCCBs protect against overcurrent. SPD addresses fast transient overvoltage. They are different devices for different faults.

For solar ACDBs and commercial generator-linked systems, this distinction matters even more because switching events are common. The buyer here is usually not protecting one TV. The buyer is protecting a whole board full of controls and expensive equipment.

Product Range and Models

Model Rating Voltage Use
YCS6 4P SPD In 20kA / Imax 40kA 385V Standard 3-phase board surge protection
YCS6 4P SPD In 20kA / Imax 40kA 440V Higher-voltage 3-phase applications
YCS6 4P SPD In 20kA / Imax 40kA 750V Special application rating
YCS6 4P SPD In 40kA / Imax 60kA 440V Higher surge-capacity board protection
YCS6 4P SPD In 60kA / Imax 80kA 440V Stronger surge-duty applications
YCS6 4P SPD 100kA 440V High surge-capacity listing

Do not pick the highest discharge number blindly. Surge coordination depends on site exposure, equipment value and board design. Many commercial boards are well served by 20/40kA class. Higher values are selected when the risk profile and panel design justify them.

Applications in Pakistan

Application Recommended Setup Why
Factory main incomer panel 4P SPD with strong earthing Protects drives, relays, meters and controls on the three-phase system
Lift and elevator distribution board 4P SPD in building main or lift board Useful where control cards and lift electronics are expensive and sensitive
Solar ACDB on commercial rooftop 4P SPD coordinated with system earthing Reduces surge stress on inverter AC output side and connected board electronics
Textile unit machine feeder board 4P SPD on distribution section Textile plants often run electronics and motors together on one board
Generator or ATS-linked commercial panel 4P SPD Switching events and utility disturbances justify surge protection
Hospital, school or office 3-phase board 4P SPD Sensitive electrical and IT infrastructure benefits from board-level surge control

Hospitals, schools, factories, plazas, textile floors and solar commercial sites are the natural audience.

Sizing and Selection Guide

Your Situation Choose This Variant Why
You have a 3-phase incoming or sub-distribution board Choose 4P SPD Correct pole configuration for full 3-phase board protection
You only have a single-phase home or shop board Choose 2P SPD instead A 4P unit is unnecessary for that application
Panel contains VFDs, meters, timers or PLCs Choose 4P SPD plus sound earthing Electronics make surge protection more valuable
Solar system has 3-phase ACDB Choose 4P SPD Board-level AC surge protection is appropriate on the three-phase side
You need stronger surge capacity because of exposure or critical load Consider higher 40/60, 60/80 or 100kA options Use system risk, not guesswork, to choose capacity
You only need a replacement plug-in module Choose SPD cartridge if the base is compatible Do not buy full assembly when only cartridge replacement is needed

Pole count is the first decision. Surge capacity is the second. Earthing quality is always part of both decisions.

CNC vs Competitors

Comparison Point CNC Alternative 1 Alternative 2
Comparison point CNC 4P SPD No SPD on 3-phase board Socket-level protectors only
Protection coverage Whole 3-phase board None Only selected plug points
Suitability for factory controls Good Poor Poor
Suitability for solar ACDB Good Poor Poor
Works with board earthing system Yes No protection path Not as coordinated
Best buyer Commercial/industrial board owner Risk-tolerant user Light office/home user only
Downtime prevention value High None Limited

For 3-phase installations, the real competitor is often no protection at all. That usually looks cheaper until one drive, one ATS controller or one lift board fails.

What This Product Does NOT Protect Against

  • It does not protect against sustained under-voltage or over-voltage. Add a voltage protector where that risk exists.
  • It does not replace MCCB, fuse or breaker protection for overcurrent faults.
  • It does not remove the need for proper earthing and bonding throughout the 3-phase board.
  • It does not guarantee survival from every direct lightning event without wider lightning protection design and correct installation practice.
  • It does not cure poor neutral management, loose lugs or unsafe ATS/generator wiring.

A 4P SPD is one layer of protection, not the whole electrical design. That honest message prevents wrong expectations and bad installations.

Installation Guide

  • Install the SPD inside the 3-phase board on rail space close to the incoming side and earth bar layout.
  • Keep conductors short, direct and neatly routed. Extra lead length reduces surge performance.
  • Coordinate the SPD with upstream protective device practice in the panel design.
  • Check the site earthing and bonding condition before commissioning the system.
  • Mark the board drawings or labels so future electricians know a 4P SPD is installed and can inspect it during maintenance.

Three-phase boards get crowded quickly. Good installation is not only about fitting the SPD physically. It is about keeping the wiring short and disciplined despite limited space around MCCBs, ATS units and meters.

Add Fire Protection to Your Panel

Protect your panel with a DIN Rail Aerosol Fire Extinguisher. Auto activation. 10-year shelf life. Fire safety guide →

Related Products

4P SPD is usually purchased as part of a larger 3-phase board strategy. These links are selected around commercial and industrial panel protection.

  • SPD collection — See other AC surge protection options and capacities.
  • MCCB collection — Protect the incoming and feeder circuits around the same board.
  • ATS collection — Many protected 3-phase boards also include automatic transfer switching.
  • Changeover switches — Useful where manual source selection still exists in commercial boards.
  • Voltage protectors — Add sustained voltage protection where the site supply is unstable.
  • DB boxes — Organize commercial or plant distribution hardware properly.
  • SPD guide — Helpful for explaining surge protection to clients and site teams.
  • Net metering guide — Relevant for 3-phase solar users coordinating AC-side protection.
  • Fire extinguisher collection — Three-phase boards also need electrical fire protection.
  • DIN rail fire extinguisher — Final add-on for large commercial and industrial panels.

Frequently Asked Questions

Why do I need 4P SPD on a 3-phase board?

Because the board carries multiple phases and often sensitive controls. A 4P SPD gives whole-board transient surge protection in the correct pole format.

Can 4P SPD be used on solar ACDB?

Yes. It is commonly relevant on the AC side of commercial and three-phase solar systems when coordinated properly with the rest of the board.

Is 20kA/40kA enough or should I buy 60kA/80kA?

That depends on exposure level, system design and the value of the equipment being protected. Higher numbers are not automatic proof of better selection.

Does 4P SPD replace voltage protector?

No. SPD handles fast transient spikes. Voltage protectors handle long-duration over and under-voltage conditions.

Can I install 4P SPD without checking earth resistance?

That is poor practice. Earthing quality directly affects SPD performance.

Will it protect VFD and PLC panels?

It helps reduce surge exposure to them when installed correctly at the board level. That is one of the main reasons to use it.

Is 4P SPD only for factories?

No. It is also useful in commercial buildings, lifts, schools, hospitals, plazas and 3-phase solar systems.

Which Pakistani cities commonly need 4P SPD?

Any city with commercial or industrial boards does. Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, Peshawar and Sialkot all have sites where 3-phase surge protection makes economic sense.

Final Word

The CNC YCS6 AC 4P SPD is meant for 3-phase boards where one surge can damage several expensive devices at once. It is relevant for factories, lifts, solar ACDBs, offices and commercial buildings across Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, Peshawar and Sialkot. Orders above Rs.10,000 qualify for free delivery. For capacity selection or board coordination help, WhatsApp 0326-1111376.

Returns & Refunds

  • Return within 7 days of delivery: unused, in original packaging, with invoice.
  • Damaged, defective or wrong item? Tell us within 72 hours on WhatsApp +92 326 1111376. We pay return shipping if the mistake is ours.
  • Refund after inspection, within 5–7 working days, to your original payment method.
  • 5-year replacement warranty on breakers for manufacturing defects. Keep the original box: warranty claims need it.

Shipping

  • Delivery across Pakistan by courier, usually 3–5 business days after dispatch.
  • Cash on Delivery in most cities; bank transfer, Easypaisa and JazzCash also accepted.
  • Free delivery on orders over Rs. 10,000.

Full details: Refund policy · Shipping policy

Related Products

Recently Viewed Products