RCBO 4P Residual Current Circuit Breakers 32A, 63A YCB6HLN

RCBO 4P Residual Current Circuit Breakers 32A, 63A YCB6HLN

Rs.3,200
Rs.3,800
Rs.3,200
AMPERE: 32A
Subtotal: Rs.3,200
RCBO 4P Residual Current Circuit Breakers 32A, 63A YCB6HLN

RCBO 4P Residual Current Circuit Breakers 32A, 63A YCB6HLN

Rs.3,800 Rs.3,200

RCBO 4P Residual Current Circuit Breakers 32A, 63A YCB6HLN

Rs.3,800 Rs.3,200
AMPERE: 32A

Not sure which voltage protector you need?

Try our VA Protector Product Finder Tool — Pakistan's first interactive selector.

4 pole RCBO buyers in Pakistan choose the RCBO 4P 32A-63A YCB6HLN when they need one device that combines earth leakage protection, overload protection, and short-circuit protection on a three-phase circuit. Starting from Rs.3,000, this three phase RCBO suits workshops, offices, lifts, small machinery feeders, commercial panels, and other 400V AC applications where panel space, simplicity, and safety all matter. For many sites in Pakistan, a 4P RCBO is the cleaner alternative to fitting a separate 4P RCCB plus a separate 4P MCB.

Quick Specs

Specification Value
Model YCB6HLN 4P RCBO
Poles 4 Pole
Voltage 400V AC three-phase
Current ratings 32A, 63A
Leakage sensitivity 30mA
Protection type Earth leakage + overload + short circuit
Mounting DIN rail
Standard IEC 61009
Warranty 5-year warranty

What This Product Does

RCBO stands for Residual Current Circuit Breaker with Overcurrent protection. In plain words, it combines two jobs in one device. First, it trips on dangerous earth leakage. Second, it trips on overload and short circuit. For three-phase panels, that is a big advantage because it reduces device count and simplifies the wiring layout inside the board.

Many Pakistani buyers understand the difference only after panel space becomes a problem. A 4P RCCB only handles leakage protection; it still needs a separate 4P MCB for overload and short circuit. A 4P RCBO combines both roles. That is why it is attractive for smaller commercial panels, pumps, workshop feeders, and three-phase loads where compactness matters.

This product is especially useful where one three-phase outgoing circuit must be protected neatly in one modular device. It is not a substitute for surge protection or voltage quality protection, but it is the correct answer when the question is leakage plus overcurrent on a 3-phase line.

When a 4P RCBO Makes More Sense Than RCCB + MCB

Choose a 4P RCBO when you want one protective device for a three-phase feeder and you want to save space in the panel. It is practical in DB boards where multiple feeders already consume DIN rail space. It is also easier to explain to non-technical buyers because one product protects against two major categories of fault.

Choose separate devices when the design requires independent selection, coordination, or replacement of the RCCB and MCB functions. In bigger engineered panels, separate devices can still make sense. But for many real-world Pakistan jobs, especially compact panels, the all-in-one format is easier and cleaner.

Selection Guide

Use Case Recommended Rating Why
Small three-phase commercial feeder 32A RCBO Suitable where the protected line current is moderate
Three-phase office / workshop feeder 63A RCBO after design check More headroom for larger outgoing line loads
Need leakage only, already have overcurrent device 4P RCCB may be considered RCBO is not always necessary if design is separate
Need one compact device for leakage + overcurrent 4P RCBO Saves space and simplifies the panel
Single-phase circuit only Use 1P+N RCBO Do not overspecify a 4P device for single-phase loads

How to Install

This product should be installed by a licensed electrician or panel builder because three-phase wiring errors are costly and can be dangerous.

  • Isolate the three-phase incoming supply and confirm zero voltage before touching the panel.
  • Mount the RCBO on DIN rail and verify the correct incoming and outgoing terminal arrangement.
  • Connect all poles correctly so phase sequence and neutral routing remain consistent with the design.
  • Torque terminals properly and test the RCBO trip function before energizing the feeder.
  • After commissioning, test leakage trip behavior and confirm load current is within the selected rating.

What This Product Does NOT Protect Against

This 4 pole RCBO does not protect against lightning and switching surges, so add a 4P AC SPD where surge risk exists. It does not protect against sustained overvoltage and undervoltage, so use a 3-phase VA protector if line conditions are poor. It is also not a substitute for good panel design, cable sizing, and coordination. The RCBO only covers earth leakage, overload, and short circuit on the protected circuit.

4P RCBO vs 4P RCCB + 4P MCB vs 1P+N RCBO

Feature 4P RCBO 4P RCCB + 4P MCB 1P+N RCBO
Leakage protection Yes Yes Yes
Overload / short circuit Yes Yes, via separate MCB Yes
Device count One combined unit Two separate units One combined unit
Best use Three-phase feeder Three-phase panel with separate design choice Single-phase circuits
Panel space Lower Higher Lower for single phase only

CNC vs Schneider / Other Brands

Feature CNC Schneider Local brands
Typical price in Pakistan Starts from Rs.3,000 Usually higher Varies widely
Three-phase protection value Strong price-to-performance Premium but expensive Often inconsistent
Warranty 5-year warranty Varies by channel Often unclear
Panel space saving Good all-in-one solution Also available in premium ranges Not always easy to verify
Suitability for Pakistan market Good balance of cost and function Good but pricier May look cheaper but riskier

Cross-Category Recommendations

If you are buying a 4P RCBO, also look at the 1P+N RCBO for single-phase lines, the 4P RCCB if you need separate leakage protection, the 4P MCB for separate overcurrent control, the 4P 3-phase VA protector for voltage problems, and the 4P AC SPD for surge protection.

Browse AC circuit breakers, DC circuit breakers, AC breaker collection, DC breaker collection, MCCBs, AC SPDs, DC SPDs, voltage protectors, voltage regulators / stabilizers, RCCB / RCBO, types of circuit breakers, solar DB guide, RCBO vs ELCB guide, types of circuit breakers guide, voltage protector vs stabilizer. This helps buyers understand where RCBO protection stops and where SPD or voltage protection begins.

Related Products from CNC Electric

FAQs

What is a 4 pole RCBO used for?

A 4 pole RCBO is used on three-phase circuits where you want both earth leakage protection and overcurrent protection in one device.

What is the RCBO price in Pakistan for this model?

This product starts from Rs.3,000. It is a practical three-phase protection option for buyers who want one compact device.

Is a 4P RCBO better than a 4P RCCB?

They do different jobs. A 4P RCBO includes overload and short-circuit protection as well, while a 4P RCCB needs a separate MCB.

Can I use this for a three-phase office or shop?

Yes, that is one of the most common use cases, provided a licensed electrician confirms the correct rating and panel design.

Does it protect against surges?

No. Add a 4P AC SPD for lightning and switching surges because an RCBO is not a surge protector.

Does it protect against low voltage and high voltage?

No. For sustained overvoltage and undervoltage, add a 3-phase VA protector on the incoming line where needed.

What is 30mA sensitivity for?

30mA is commonly used for personal-protection-level earth leakage tripping, helping disconnect a circuit when leakage becomes dangerous.

Is this available across Pakistan?

Yes, CNC Electric Pakistan supplies across Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, Peshawar, and other cities with free delivery positioning in these product pages.

For three-phase safety, the right protective chain is usually RCBO or RCCB, plus MCB coordination, plus SPD and voltage protection where needed. CNC Electric Pakistan offers free delivery, 5-year warranty support, and matching panel accessories. WhatsApp us at 0326-1111376. Pair with an aerosol fire extinguisher for added panel safety.

See also: RCCB Breaker Guide

Returns & Refunds

  • Return within 7 days of delivery: unused, in original packaging, with invoice.
  • Damaged, defective or wrong item? Tell us within 72 hours on WhatsApp +92 326 1111376. We pay return shipping if the mistake is ours.
  • Refund after inspection, within 5–7 working days, to your original payment method.
  • 5-year replacement warranty on breakers for manufacturing defects. Keep the original box: warranty claims need it.

Shipping

  • Delivery across Pakistan by courier, usually 3–5 business days after dispatch.
  • Cash on Delivery in most cities; bank transfer, Easypaisa and JazzCash also accepted.
  • Free delivery on orders over Rs. 10,000.

Full details: Refund policy · Shipping policy

Related Products

Recently Viewed Products