DB Boxes
-
Plastic Body 4, 8, 12, 18, 24 Way Distribution Box YCX1 | Surface Mount Design
- Rs.1,050
Rs.1,700- Rs.1,050
- Unit price
- per
The Plastic Body 4-24 Way Distribution Box YCX1 is a surface-mount distribution box for homes, shops, offices, and light commercial panels in Pakistan. Starting from Rs.1,050, this DB box provides the enclosure where your MCBs, RCBOs, SPDs, and voltage protectors live. If you are...- Rs.1,050
Rs.1,700- Rs.1,050
- Unit price
- per
-
Steel Body 9, 12, 16, 20, 24 Way Distribution Box YCX6 – Surface Mount Design Boxes
- Rs.3,600
Rs.4,100- Rs.3,600
- Unit price
- per
General: The DB Box YCX6 is applicable to residential buildings or places for non-professional people to enter, and it includes control equipment and signal equipment. It is suitable for circuits with alternating current, where the nominal voltage to earth does not exceed 380V, and the output...- Rs.3,600
Rs.4,100- Rs.3,600
- Unit price
- per
-
Waterproof Distribution Box 12, 18 Ways HA | Safe & Weather-Resistant
- Rs.4,700
Rs.5,300- Rs.4,700
- Unit price
- per
Looking for a waterproof DB box price in Pakistan for a home panel, shop installation, service area, or outdoor feeder point? This CNC Electric HA Series waterproof distribution box is listed at Rs. 4,600 and gives you a practical enclosure for housing breakers and...- Rs.4,700
Rs.5,300- Rs.4,700
- Unit price
- per
-
Waterproof Distribution Box 12, 18 Ways IP65 YCX8 | Safe & Weather-Resistant
- Rs.6,150
Rs.6,950- Rs.6,150
- Unit price
- per
Waterproof DB box IP65 is the right choice when your distribution board cannot stay inside a clean dry room. This CNC Electric Pakistan listing is for a weatherproof enclosure sold in 12-way and 18-way options, starting from Rs.5,800 in Pakistan. It suits outdoor walls,...- Rs.6,150
Rs.6,950- Rs.6,150
- Unit price
- per
Updated: May 2026 · CNC Electric Pakistan
DB Box (Distribution Board) — Pakistan Quick Answer (May 2026)
A DB Box (Distribution Board, sometimes called electric panel or load center) in Pakistan houses all your circuit breakers (MCBs, RCCB, voltage protector) in a single enclosure, organising power distribution from the main incoming supply to individual circuits. It's the single most important electrical component in every Pakistani home — the safety and reliability of all wiring depends on the DB box design. CNC 2026 prices range from Rs. 1,800 (4-way plastic surface) for small homes to Rs. 18,500 (24-way metal flush with door) for commercial installations.
| House Type | Recommended DB Box | Capacity | 2026 PKR |
|---|---|---|---|
| Studio / small flat (1-2 rooms) | 4-way plastic surface | 4 single-pole MCB slots | 1,800 |
| 3-5 marla home | 8-way plastic surface | 8 single-pole MCB slots | 2,800 |
| 5-10 marla home (single-phase) | 12-way plastic / metal surface | 12 MCB slots + main switch | 4,500–5,500 |
| 10-marla + (multi-AC) | 18-way metal flush with door | 18 slots + main + RCCB | 7,500 |
| 3-phase home / shop main | 12-way 3-phase metal | 36-pole equivalent (12 × 4P) | 9,500 |
| Large commercial / 3-phase shop | 24-way metal flush with door | 24 slots + breaker + indicator | 18,500 |
Sizing rule: Count circuits needed (lighting, sockets per room, AC per room, geyser, motor, kitchen) + 30% spare. Typical 5-marla home = 7 circuits → use 12-way DB (leaves 5 spare). Never max out — every panel needs spare for future loads.
Read also: Circuit Breakers · RCCB · Voltage Protectors
Plastic vs Metal Body — Which to Choose
| Factor | Plastic Body | Metal Body |
|---|---|---|
| Price | Cheaper (~40% less) | Higher |
| Durability | 10-15 years | 25+ years |
| Fire rating | V-0 self-extinguishing (proper PC/ABS) | Non-flammable |
| Best for | Residential interior, dry locations | Commercial, industrial, outdoor |
| Tamper resistance | Low | High (lockable door) |
| Earthing | Earth bar only | Body itself bonded to earth |
Surface vs Flush Mount
- Surface-mount: bolts on top of finished wall. Easier install, less expensive. Good for retrofit, garages, outhouses.
- Flush-mount: recessed into the wall, only the cover sits flush with plaster. Cleaner look, premium feel. Requires wall pocket during construction.
How Many Ways Do You Actually Need?
Standard circuit count for Pakistani homes:
| Home Type | Typical Circuits | Min Ways Needed |
|---|---|---|
| Studio (1 room + bath) | Lights, sockets, geyser, AC | 4-6 ways |
| 3-marla (2 rooms) | + kitchen, more sockets | 6-8 ways |
| 5-marla (3 rooms) | + 2 ACs, water motor | 10-12 ways |
| 10-marla (4-5 rooms) | + 3-4 ACs, geyser × 2 | 16-18 ways |
| 1-kanal (6+ rooms) | + submersible, EV charger ready | 24+ ways |
What Goes INSIDE the DB Box — Best Practice for Pakistan
- Main switch / MCCB at the top (incoming WAPDA / generator)
- Voltage protector or stabilizer relay (optional, recommended for inverter homes)
- Main RCCB (30 mA, protects entire house from earth leakage)
- Individual MCBs per circuit: 1P 16A for lighting, 1P 20A for sockets, 1P 32A for AC, 1P 16A for motor
- Spare slots (30% empty for future expansion)
- Earth bar + neutral bar at the bottom
DB Box FAQ — Pakistan
Q1: What is the price of a DB box in Pakistan?
CNC DB box prices in 2026 start at Rs. 1,800 for a 4-way plastic surface (small flat) and go up to Rs. 18,500 for a 24-way metal flush with door (commercial). Most-bought size for Pakistani 5-marla home is 12-way plastic at Rs. 4,500.
Q2: How many ways DB box do I need for my house?
5-marla home → 10-12 ways. 10-marla → 16-18 ways. 1-kanal → 24+ ways. Always size 30% larger than current circuit count to allow future expansion.
Q3: Plastic or metal DB box — which is better?
Plastic is cheaper and adequate for residential indoor use (V-0 fire-rated). Metal is more durable (25+ years), tamper-resistant, and required for commercial / outdoor / industrial. Both are PSQCA-approved when from CNC.
Q4: Should the DB box have an RCCB?
Yes — strongly recommended for any new installation. A 30 mA RCCB at the main protects the entire house from electric shock. Pakistani electrical code now requires RCCB in all new constructions; older homes should retrofit.
Q5: Surface or flush mount DB box?
Surface-mount = easier install, no wall cutting. Flush-mount = cleaner look, sits inside wall. Surface for retrofits, flush for new construction.
Q6: Is CNC DB box PSQCA certified?
Yes. All CNC DB boxes carry PSQCA approval and IEC 61439 compliance. The holographic sticker is on the inside cover.
Q7: What size cable for the main incoming to DB box?
For single-phase 40A main: 10 mm² copper. For 60A main: 16 mm². For 80A main: 25 mm². For 3-phase 63A main: 4 × 10 mm² copper. Always have the incoming cable rated higher than the main breaker.
Keep your electrical systems organized, safe, and reliable with premium DB Boxes (also commonly known as DP box in Pakistan) from CNCelectric.pk. Designed for homes, offices, factories, and industrial panels, our distribution boxes provide a secure housing for MCBs, RCCBs, fuses, and other essential electrical components.
Whether you are installing a new electrical setup or upgrading an existing panel, our DB Boxes offer maximum protection, easy installation, and a professional finish. They are available in plastic and metal variants, ensuring durability, fire resistance, and long-term safety.
Features & Benefits:
- Durable & Fire-Resistant: Made from high-quality materials to withstand heat and impact.
- Complete Circuit Protection: Safeguards your wiring and devices from dust, moisture, and accidental contact.
- Versatile & Modular: Supports MCBs, RCCBs, fuses, and other modular electrical devices.
- Easy Installation: Lightweight design with pre-marked knockouts and mounting options for quick setup.
- Professional & Neat Appearance: Keeps your wiring organized and panels clean for a polished look.
- Multiple Sizes Available: Choose the right size for your residential, commercial, or industrial needs.
At CNCelectric.pk, we ensure that every DB Box delivers reliable performance, safety, and value. With competitive DB Box prices in Pakistan, you get the perfect combination of quality and affordability.
Related Guide: Solar DB Box Guide for Pakistan
📊 Read: 33 Electrical Fires in Pakistan — Protect Your DB Box
📖 Related Guide: DB Box Wiring Guide Pakistan
📊 Related: digital energy meter — kWh meters for single-phase and 3-phase metering in Pakistan.
Frequently Asked Questions
What is the price of a DB box in Pakistan in 2026?
CNC plastic DB box 4-way starts at PKR 1,200, 8-way at PKR 2,200, 12-way at PKR 3,400. Metal-body DB boxes from PKR 2,800, weatherproof IP65 DB boxes from PKR 4,500.
Metal vs plastic DB box — which is safer?
Metal DB boxes have better fire resistance and are required by code for some commercial installations. Plastic (uPVC) DB boxes are lighter, cheaper, and fine for residential indoor use. For outdoor or solar installations, use IP65 metal.
How many ways do I need for a typical Pakistani home?
8-way for a 1-bedroom, 12-way for a 2-3 bedroom house with AC + tubewell, 18-way for a larger house with solar + EV charger.
Do CNC DB boxes come with breakers pre-installed?
No — DB boxes are sold separately from breakers. This lets you mix and match the exact breaker sizes you need. We can pre-assemble a complete DB box on request — message us via WhatsApp.
Are CNC DB boxes IP-rated for outdoor use?
Indoor DB boxes are IP20. Weatherproof DB boxes are IP65 (dust-tight, jet-water resistant) — required for outdoor solar combiner installations.