{"product_id":"cnc-ycqva-2-automatic-transfer-switch-ats-2-pole-dual-power-changeover","title":"CNC YCQVA-2 Automatic Transfer Switch (ATS) | 2 Pole Dual Power Changeover","description":"\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eGeneral\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe YCQVA-2 series products are applicable to rated currents of 100A and below, supporting intelligent switching between dual power supplies of mains-to-mains and mains-to-generator. The two input circuits adopt a physical isolation design, fully complying with electrical safety specifications and standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eIt features dual modes of automatic circuit switching and manual free switching for flexible and convenient use. The overvoltage and undervoltage protection thresholds can be customized; automatic power-off protection is triggered immediately when the voltage exceeds the set range. A built-in delayed restart mechanism enables automatic closing and power supply restoration after the grid voltage stabilizes. Meanwhile, it allows independent setting of the current limiting value, with automatic power-off upon overcurrent and self-recovery after fault elimination. The complete machine integrates multiple safety protections including neutral loss, overvoltage, undervoltage and overload, comprehensively preventing hidden risks such as grid voltage fluctuations and current abnormalities. It effectively ensures the long-term stable operation of rear-end electrical equipment and avoids fault damage.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eType designation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"table_wrap\"\u003e\n\u003cdiv class=\"scroll\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\" style=\"width: 100.08%; height: 160.625px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"150\" style=\"width: 27.6348%;\"\u003e\n\u003ccol width=\"196\" style=\"width: 36.1663%;\"\u003e\n\u003ccol width=\"237\" style=\"width: 35.9808%;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd width=\"150\" height=\"35\" style=\"text-align: center; height: 35px;\"\u003eModel\u003c\/td\u003e\n\u003ctd width=\"196\" style=\"text-align: center; height: 35px;\"\u003eRated current\u003c\/td\u003e\n\u003ctd width=\"237\" style=\"text-align: center; height: 35px;\"\u003eRated supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30px;\"\u003e\n\u003ctd width=\"150\" height=\"30\" style=\"text-align: center; height: 30px;\"\u003eYCQVA-2\u003c\/td\u003e\n\u003ctd width=\"196\" style=\"text-align: center; height: 30px;\"\u003e63A\u003c\/td\u003e\n\u003ctd width=\"237\" style=\"text-align: center; height: 30px;\"\u003eAC220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 95.625px;\"\u003e\n\u003ctd rowspan=\"2\" width=\"150\" height=\"92\" style=\"text-align: center; height: 95.625px;\"\u003e  Automatic\u003cbr\u003etransfer switch\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"196\" style=\"text-align: center; height: 95.625px;\"\u003e63A\u003cbr\u003e80A\u003cbr\u003e100A\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"237\" style=\"text-align: center; height: 95.625px;\"\u003eAC220V\u003cbr\u003eAC110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eOperating conditions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e1. When installing the product, the input terminal must be connected to a circuit breaker.\u003c\/div\u003e\n\u003cdiv\u003e2. After receiving the product, first connect only one power source to check if the display is normal.\u003c\/div\u003e\n\u003cdiv\u003e3. The equipment must be installed by qualified professionals.\u003c\/div\u003e\n\u003cdiv\u003e4. Before operating the device, disconnect all power supplies and do not touch any terminal when the power supply is connected.\u003c\/div\u003e\n\u003cdiv\u003e5. Verify that terminals are properly connected.\u003c\/div\u003e\n\u003cdiv\u003e6. Do not use the equipment in places that may be corroded by gas, strong sunlight and rain.\u003c\/div\u003e\n\u003cdiv\u003e7. Clean equipment with a dry cloth.\u003c\/div\u003e\n\u003cdiv\u003e8. Failure to comply with these instructions will result in serious injury or serious accident.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv\u003e1. Automatic Transfer Switch: with “priority” phase\u003c\/div\u003e\n\u003cdiv\u003e2. Microcontroller-based\u003c\/div\u003e\n\u003cdiv\u003e3. Digital display of working voltage, current\u003c\/div\u003e\n\u003cdiv\u003e4. Measurement accuracy is 0.5 class\u003c\/div\u003e\n\u003cdiv\u003e5. Key setting parameter\u003c\/div\u003e\n\u003cdiv\u003e6. Can set the priority phase sequence\u003c\/div\u003e\n\u003cdiv\u003e7. DIN rail mounting\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical data\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"table_wrap\"\u003e\n\u003cdiv class=\"scroll\" style=\"text-align: center;\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\" style=\"width: 100.08%; height: 439.233px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"217\" style=\"width: 40.1109%;\"\u003e\n\u003ccol width=\"293\" style=\"width: 54.159%;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 27.5852px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 27.5852px; text-align: center;\"\u003eRated supply voltage\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 27.5852px; text-align: center;\"\u003eAC 2*110V\/220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eOperating voltage range\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003eAC 80-300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eRated frequency\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eHysteresis\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003eOvervoltage:5V Undervoltage:5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e0.5 class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eRated insulation voltage\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e450V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eOutput contact\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e1NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eElectrical life\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eSwitch delay to reserve phases\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e\u0026gt;0.2s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eOvervoltage trip delay\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e0.1s; ≥350V; 0.02s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eUndervoltage trip delay\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e0.1s; ≥350V; 0.02s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eMechanical life\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eProtection class\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003ePollution degree\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eAltitude\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e-5°C~40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e≤50% or 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e-10°C~55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eProduct size\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e63A:90*96*67mm ; 80A\/100A:90*103*67mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eVoltage accuracy\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e\u0026lt;1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eRated operating current\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e63A\/80A\/100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd width=\"217\" height=\"19\" style=\"height: 19.6023px;\"\u003eMax. operating current\u003c\/td\u003e\n\u003ctd width=\"293\" style=\"height: 19.6023px;\"\u003e63A\/100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"Default Title","offer_id":46038397485122,"sku":null,"price":10000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/CNCElectricDualPowerATSModule.png?v=1794826303","url":"https:\/\/www.cncelectric.pk\/products\/cnc-ycqva-2-automatic-transfer-switch-ats-2-pole-dual-power-changeover","provider":"CNC Electric Pakistan","version":"1.0","type":"link"}