{"product_id":"cnc-ycqd7-integrated-star-delta-motor-starter","title":"Star-Delta Motor Starter 45–75 kW | Intelligent Integrated Reduced-Voltage Starter (YCQD7)","description":"\u003cp\u003e\u003cem\u003eSizing a motor starter? Match the starter to the motor's kW and starting profile — the selection guide below is your starting point, but always confirm on site.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eIndustrial buyers in Pakistan choose the \u003cstrong\u003eCNC YCQD7 intelligent integrated star-delta starter\u003c\/strong\u003e when they need to start a large three-phase motor without hammering the supply with a full direct-on-line inrush. It packs the main, star and delta contactors, an intelligent controller and the auxiliary contacts into one compact module — the smooth star-to-delta start that used to need three separate contactors plus a timer, now factory-integrated. This listing is the \u003cstrong\u003eZ (multifunctional)\u003c\/strong\u003e type, which adds a full motor-protection suite and an on-board display.\u003c\/p\u003e\n\u003ch2\u003eQuick Specs\u003c\/h2\u003e\n\u003ctable class=\"spec\" style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;line-height:1.5\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eCNC YCQD7 Intelligent Integrated Star-Delta Starter (Z \/ multifunctional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eStart method\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eStar → Delta (reduced-voltage), adjustable star run time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eRated current Ie (AC-3)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003e65 – 110 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eMotor power\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003e45 – 90 kW (this listing 45 \/ 55 \/ 75 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eRated voltage Ue\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003e380 V \/ 400 V, 3-phase, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eInsulation voltage Ui\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003e800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eControl (coil) voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003e220 \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eProtection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eOverload · locked-rotor · phase-loss · 3-phase imbalance · over-voltage · under-voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eIndication\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eLCD display + fault alarm, status \u0026amp; power indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eCommunication\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eRS-485 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eShort-circuit protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eNot built in — fit an upstream fuse (NH1-125) or MCCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eIEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003ePanel \/ screw-fix, vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eWarranty\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003e5-year replacement warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cp style=\"max-width:75ch\"\u003eFull technical documentation from CNC Electric:\u003c\/p\u003e\n\u003cul class=\"steps\"\u003e\n\u003cli\u003e📄 \u003ca href=\"https:\/\/www.cncele.com\/uploads\/YCQD7-Instructions-24.06.pdf\" target=\"_blank\"\u003eUser Manual \/ Instructions (PDF)\u003c\/a\u003e — wiring, star-time and protection setup, terminal layout.\u003c\/li\u003e\n\u003cli\u003e📘 \u003ca href=\"https:\/\/www.cncele.com\/uploads\/YCQD7-Sample-Book24.06.pdf\" target=\"_blank\"\u003eSpecification Sheet \/ Sample Book (PDF)\u003c\/a\u003e — full ratings table, model matrix, dimensions.\u003c\/li\u003e\n\u003cli\u003e📐 \u003ca href=\"https:\/\/www.cncele.com\/uploads\/YCQD7-3D.zip\" target=\"_blank\"\u003e3D Drawings (ZIP)\u003c\/a\u003e — for panel layout and CAD.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat This Product Does\u003c\/h2\u003e\n\u003cp\u003eA big squirrel-cage motor started direct-on-line pulls 6–8× its rated current for the first few seconds. On a Pakistani supply — especially on a genset or a weak rural feeder — that inrush trips breakers, dips the voltage for everything else, and stresses the motor windings and couplings. A star-delta starter cuts that starting current to roughly one-third by first connecting the motor windings in star (each winding sees only 58% of line voltage), then switching to delta for full-voltage running once the motor is up to speed.\u003c\/p\u003e\n\u003cp\u003eThe YCQD7 does this automatically: energise the 220 V control coil and the intelligent controller closes the main + star contactors for the reduced-voltage start, waits out the adjustable star time, then drops the main contactor and re-closes with the delta contactor for normal running. On the Z version, the controller also watches the motor continuously and trips on overload, locked rotor, phase loss, three-phase imbalance, and over\/under-voltage — showing the fault on its display so your operator knows why it stopped.\u003c\/p\u003e\n\u003ch2\u003eWhere It Fits Best in Pakistan\u003c\/h2\u003e\n\u003cp\u003eThis starter is relevant for buyers in Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, Gujranwala and Peshawar running larger motor loads — flour and feed mills, water and irrigation pumps, compressors, crushers, blowers and industrial fans. Anywhere a 40–120 HP motor is started against the line, a star-delta starter protects both the supply and the motor. Pair it with an upstream \u003ca href=\"#\"\u003eMCCB\u003c\/a\u003e for short-circuit protection and, where the motor is remote, a local \u003ca href=\"#\"\u003eisolator switch\u003c\/a\u003e for safe maintenance.\u003c\/p\u003e\n\u003ch2\u003eSelection Guide\u003c\/h2\u003e\n\u003ctable class=\"cmp\" style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;line-height:1.5\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eMotor\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eRecommended variant\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eUp to ~60 HP \/ 45 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003e45 kW (65 A frame)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eCovers most mill and pump motors in this band with headroom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003e~60–75 HP \/ 55 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003e55 kW (85 A frame)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eMid-range crushers, blowers, larger pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003e~100 HP \/ 75 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003e75 kW (110 A frame)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eLarge mill mains, big compressors and fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eMotor must be startable during a wiring fault (fire pump)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eAsk for the \"S\" mechanical-emergency type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eAdds a manual forced-start lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eSizing must match the motor nameplate current and its starting profile — confirm on site with your electrician before ordering.\u003c\/p\u003e\n\u003ch2\u003eHow to Install\u003c\/h2\u003e\n\u003cul class=\"steps\"\u003e\n\u003cli\u003eInstallation must be done by a licensed electrician or qualified panel technician.\u003c\/li\u003e\n\u003cli\u003eFit an upstream short-circuit device (fuse NH1-125 or an MCCB) — the starter does not include short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eBring the six motor leads out (both ends of all three windings) to the starter's motor terminals — star-delta needs all six.\u003c\/li\u003e\n\u003cli\u003eFeed the 220 V control voltage to the coil terminals; set the star run-time and protection thresholds on the display.\u003c\/li\u003e\n\u003cli\u003eConfirm rotation, then test the star→delta changeover on no load before committing the drive.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat This Product Does NOT Do\u003c\/h2\u003e\n\u003cp\u003eA star-delta starter softens the \u003cem\u003estart\u003c\/em\u003e only — it does \u003cstrong\u003enot\u003c\/strong\u003e give variable running speed (for that you need a \u003ca href=\"#\"\u003eVFD\u003c\/a\u003e). It has \u003cstrong\u003eno built-in short-circuit protection\u003c\/strong\u003e, so it always needs an upstream fuse or MCCB, and it is \u003cstrong\u003enot an isolator\u003c\/strong\u003e — add a separate disconnect for safe maintenance. The star-to-delta transition is a step change, so there is a brief torque dip at changeover; for a completely smooth ramp choose an electronic soft starter.\u003c\/p\u003e\n\u003ch2\u003eStar-Delta vs Soft Starter vs VFD\u003c\/h2\u003e\n\u003ctable class=\"cmp\" style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;line-height:1.5\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eStar-Delta (this)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eSoft Starter (YCQR)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eVFD (YCB600)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eReduces start inrush\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eYes (step to ⅓)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eYes (smooth ramp)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eYes (frequency ramp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eVariable running speed\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eTransition\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eStep (brief dip)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eSmooth\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eSmooth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eRelative cost\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eLowest\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eMid\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eHighest\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eBest for\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eBig motors needing a gentle, low-cost start\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eWhere a smoother start matters\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eAnything needing speed control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCNC vs Schneider vs Local Assembly\u003c\/h2\u003e\n\u003ctable class=\"cmp\" style=\"width:100%;border-collapse:collapse;margin:16px 0;font-size:15px;line-height:1.5\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eCNC YCQD7\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003ePremium brands\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px;text-align:left;background:#f5f5f5;font-weight:600;vertical-align:top\"\u003eLoose contactors + timer\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eBuild\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eOne integrated, tested module\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eIntegrated, premium price\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003e3 contactors + timer, site-wired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eMotor protection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eBuilt in (Z type)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eBuilt in\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eAdd a separate relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003ePrice in Pakistan\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eStrong value\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eMuch higher\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eCheap parts, more labour + wiring faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003e5-year\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eChannel dependent\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;vertical-align:top\"\u003eNone on the assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCross-Category Recommendations\u003c\/h2\u003e\n\u003cp\u003eIf you're buying this starter, also consider an upstream \u003ca href=\"#\"\u003eMCCB\u003c\/a\u003e for short-circuit protection, a local \u003ca href=\"#\"\u003eisolator switch\u003c\/a\u003e at the motor, and a \u003ca href=\"#\"\u003eDIN power supply\u003c\/a\u003e for control voltage. For speed-controlled loads see our \u003ca href=\"#\"\u003eVFD range\u003c\/a\u003e; for a smoother start see our \u003ca href=\"#\"\u003esoft starters\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"faq\"\u003e\u003csummary\u003eWhat size YCQD7 do I need for my motor?\u003c\/summary\u003e\u003cp\u003eMatch the starter to the motor's kW and full-load current. As a guide: up to ~45 kW use the 65 A frame, ~55 kW the 85 A frame, and ~75 kW the 110 A frame. Always confirm against the motor nameplate and starting profile on site.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"faq\"\u003e\u003csummary\u003eDoes it need six wires from the motor?\u003c\/summary\u003e\u003cp\u003eYes. Star-delta starting brings both ends of all three windings out, so the motor must have six leads available at its terminal box (delta-connectable at line voltage).\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"faq\"\u003e\u003csummary\u003eDoes it include short-circuit protection?\u003c\/summary\u003e\u003cp\u003eNo. Fit an upstream fuse (NH1-125) or an MCCB. The YCQD7 handles starting and motor protection; the upstream device handles short circuits.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"faq\"\u003e\u003csummary\u003eHow is it different from a soft starter or VFD?\u003c\/summary\u003e\u003cp\u003eStar-delta softens the start in one step and is the most economical option. A soft starter ramps more smoothly; a VFD adds full variable-speed control. None of the three is \"better\" — you choose by whether you need speed control (VFD), a smooth ramp (soft starter), or a low-cost gentle start (star-delta).\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"faq\"\u003e\u003csummary\u003eCan a normal electrician install it?\u003c\/summary\u003e\u003cp\u003eA licensed electrician or qualified panel technician should install and commission it, including the upstream protection, the six motor leads, and the star-time \/ protection settings on the display.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"faq\"\u003e\u003csummary\u003eIs it available across Pakistan?\u003c\/summary\u003e\u003cp\u003eYes — CNC Electric Pakistan delivers nationwide with free delivery and cash on delivery, with common demand from Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad and Peshawar.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdiv class=\"whatsapp\"\u003eNeed help sizing this for your motor? \u003cstrong\u003eWhatsApp 0326-1111376\u003c\/strong\u003e with your motor kW \/ HP and we'll confirm the right frame. Free delivery, 5-year warranty, cash on delivery.\u003c\/div\u003e","brand":"CNC","offers":[{"title":"45 kW (65 A)","offer_id":45139667255362,"sku":"YCQD7-65Z","price":0.0,"currency_code":"PKR","in_stock":true},{"title":"55 kW (85 A)","offer_id":45139667288130,"sku":"YCQD7-85Z","price":0.0,"currency_code":"PKR","in_stock":true},{"title":"75 kW (110 A)","offer_id":45139667320898,"sku":"YCQD7-110Z","price":0.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/YCQD7-65Z_E6_AD_A3.jpg?v=1788450588","url":"https:\/\/www.cncelectric.pk\/products\/cnc-ycqd7-integrated-star-delta-motor-starter","provider":"CNC Electric Pakistan","version":"1.0","type":"link"}