{"product_id":"cnc-ycch6-modular-ac-contactor","title":"Modular AC Contactor 40A 2P | DIN-Rail Installation Contactor for Lighting \u0026 Heating (YCCH6)","description":"\u003cdiv style=\"font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',Roboto,Arial,sans-serif;font-size:15px;line-height:1.7;color:#222;max-width:820px;margin:0 auto;\"\u003e\n\n\u003cdiv style=\"background:#fff5f5;border-left:4px solid #d42027;padding:16px 18px;margin:0 0 24px;border-radius:4px;\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0;\"\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e The CNC YCCH6 is a \u003cstrong\u003emodular DIN-rail AC contactor\u003c\/strong\u003e for switching lighting, heating and other resistive or low-inductive loads remotely and silently from your distribution board. It covers \u003cstrong\u003e16 A to 100 A\u003c\/strong\u003e in 2-pole and 4-pole versions, with coil options of 24, 110 or 230 V, and clips straight onto a 35 mm DIN rail. Built to IEC 61095. Price on request.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0 0 14px;\"\u003eWhen you need to switch a large lighting circuit, a heater bank, a pump or a floor of sockets from a single control signal — a timer, a switch, a building-management system — you use a \u003cstrong\u003emodular contactor\u003c\/strong\u003e. It sits in the distribution board on DIN rail, takes little width, and switches the load quietly and reliably tens of thousands of times.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:34px;margin-bottom:12px;color:#111;\"\u003eWhat the YCCH6 does\u003c\/h2\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0 0 14px;\"\u003eThe YCCH6 switches a load on and off in response to a small control voltage on its coil. It's designed for \u003cstrong\u003eAC-1, AC-7a and AC-7b\u003c\/strong\u003e duties — resistive and low-inductive household and commercial loads such as lighting, heating and small motors — and operates quietly enough for use in occupied buildings. Being modular, it lines up neatly beside MCBs and RCBOs on the same rail.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:34px;margin-bottom:12px;color:#111;\"\u003eModel range (16–100 A)\u003c\/h2\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0 0 14px;\"\u003eAvailable in 2-pole and 4-pole, in module widths from 18 mm (one module) upward, with a choice of contact configurations:\u003c\/p\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:18px 0;font-size:14px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;background:#f0f0f0;padding:8px;text-align:left;font-weight:700;\"\u003ePoles\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;background:#f0f0f0;padding:8px;text-align:left;font-weight:700;\"\u003eRated current AC-7a (A)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;background:#f0f0f0;padding:8px;text-align:left;font-weight:700;\"\u003eModule width\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;background:#f0f0f0;padding:8px;text-align:left;font-weight:700;\"\u003eContact configurations\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e2-pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e16 \/ 20 \/ 25 \/ 32\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e18 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e2NO, 2NC, 1NO+1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e2-pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e40\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e36 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e1NO, 1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e2-pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e63\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e36 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e2NO, 2NC, 1NO+1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e2-pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e100\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e54 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e2NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e4-pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e16 \/ 20 \/ 25\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e36 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e4NO, 4NC, 3NO, 3NC, 3NO+1NC, 2NO+2NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e4-pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e40 \/ 63\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e54 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e4NO, 4NC, 3NO, 3NC, 3NO+1NC, 2NO+2NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e4-pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e100\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e108 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:8px;\"\u003e4NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0 0 14px;\"\u003eCoil voltage options are 24, 110 or 230 V (230 V is standard). A sister version, the \u003cstrong\u003eYCCH6Z\u003c\/strong\u003e, offers a universal \u003cstrong\u003eAC\/DC coil\u003c\/strong\u003e (12\/24\/48\/110\/230 V) for control systems that switch the coil with DC.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:34px;margin-bottom:12px;color:#111;\"\u003eKey specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:18px 0;font-size:15px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;background:#f0f0f0;padding:10px;text-align:left;font-weight:700;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;background:#f0f0f0;padding:10px;text-align:left;font-weight:700;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003eUtilization categories\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003eAC-1, AC-7a, AC-7b\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003eRated current (thermal, Ith)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003e16 \/ 20 \/ 25 \/ 32 \/ 40 \/ 63 \/ 100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003eRated operating voltage Ue\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003e250 V (2P) \/ 400 V (4P), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003eRated insulation voltage Ui\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003eCoil voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003e24 \/ 110 \/ 230 V (230 V standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003eControlled power (AC-7a)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003e3.5–22 kW @230 V · 13.5–69 kW @400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003eElectrical \/ mechanical life\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003e10 ×10⁵ \/ 100 ×10⁵ operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003eOperating frequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003e100 operations\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003eStandards\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003eIEC 61095, GB17885\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003e35 mm DIN rail (TH35)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003eAmbient \/ altitude\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px;\"\u003e−5 to +40 °C, ≤2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:34px;margin-bottom:12px;color:#111;\"\u003eModel code\u003c\/h2\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0 0 14px;\"\u003eThe code reads \u003cstrong\u003eYCCH6-[current] \/ [contacts]\u003c\/strong\u003e, where the contact figure is NO-count then NC-count: \u003cstrong\u003e\/20\u003c\/strong\u003e = 2NO, \u003cstrong\u003e\/02\u003c\/strong\u003e = 2NC, \u003cstrong\u003e\/11\u003c\/strong\u003e = 1NO+1NC, \u003cstrong\u003e\/40\u003c\/strong\u003e = 4NO, \u003cstrong\u003e\/04\u003c\/strong\u003e = 4NC, \u003cstrong\u003e\/22\u003c\/strong\u003e = 2NO+2NC, \u003cstrong\u003e\/31\u003c\/strong\u003e = 3NO+1NC. A \u003cstrong\u003eZ\u003c\/strong\u003e suffix denotes the AC\/DC-coil YCCH6Z family.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:34px;margin-bottom:12px;color:#111;\"\u003eWhat the YCCH6 is (and isn't)\u003c\/h2\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0 0 14px;\"\u003eThe YCCH6 is a \u003cstrong\u003emodular household\/commercial contactor\u003c\/strong\u003e to IEC 61095 — ideal for lighting and heating control in a distribution board. It is not an industrial motor-duty contactor for heavy AC-3 motor starting (that is a different series). If you need to force the contactor on or off \u003cstrong\u003eby hand\u003c\/strong\u003e as well as automatically, choose the \u003ca href=\"\/products\/cnc-ycch7-modular-ac-contactor-manual-override\" style=\"color:#d42027;text-decoration:underline;\"\u003eCNC YCCH7 with manual override\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:34px;margin-bottom:12px;color:#111;\"\u003eDownloads\u003c\/h2\u003e\n\u003cul style=\"margin:0 0 16px;padding-left:22px;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.7;margin-bottom:8px;\"\u003e\u003ca href=\"https:\/\/www.cncele.com\/uploads\/YCCH6-YCCH7-%E8%AF%B4%E6%98%8E%E4%B9%A622..1.pdf\" style=\"color:#d42027;text-decoration:underline;\"\u003eYCCH6 \/ YCCH7 user manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.7;margin-bottom:8px;\"\u003e\u003ca href=\"https:\/\/www.cncele.com\/uploads\/YCCH6-YCCH7-%E6%A0%B7%E6%9C%AC-23.11.18.pdf\" style=\"color:#d42027;text-decoration:underline;\"\u003eYCCH6 \/ YCCH7 catalogue (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.7;margin-bottom:8px;\"\u003e\u003ca href=\"https:\/\/www.cncele.com\/uploads\/2210-YCCH6-YCCH7-CE-certification-GTS1.pdf\" style=\"color:#d42027;text-decoration:underline;\"\u003eCE certificate (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:34px;margin-bottom:12px;color:#111;\"\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:22px;margin-bottom:6px;color:#111;\"\u003eWhat is a modular contactor used for?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0 0 14px;\"\u003eA modular contactor switches a load — lighting, heating, sockets, a pump — on and off from a control signal, mounted on DIN rail in the distribution board. It lets a small switch, timer or building system control a large circuit safely and quietly.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:22px;margin-bottom:6px;color:#111;\"\u003eHow is it different from a normal contactor?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0 0 14px;\"\u003eA modular contactor is built to IEC 61095 for household and similar loads, is narrow (DIN-module width) so it fits beside MCBs in a consumer unit, and is designed to operate quietly. Industrial contactors are built to IEC 60947 for heavy motor duty and are physically larger.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:22px;margin-bottom:6px;color:#111;\"\u003eWhat does AC-7a mean?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0 0 14px;\"\u003eAC-7a is the IEC 61095 category for slightly inductive household loads such as lighting and small appliances; AC-7b covers household motor loads. The YCCH6 carries ratings in both, plus AC-1 for purely resistive loads.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:22px;margin-bottom:6px;color:#111;\"\u003eWhich coil voltage should I choose?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0 0 14px;\"\u003eMatch the coil to the control voltage your switch, timer or controller provides — 24, 110 or 230 V (230 V is the common choice). For DC control signals, use the YCCH6Z AC\/DC-coil version.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:22px;margin-bottom:6px;color:#111;\"\u003eHow much DIN space does it take?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0 0 14px;\"\u003eFrom 18 mm (one module) for the smaller 2-pole ratings up to 108 mm for the 100 A 4-pole. The model range table lists the width for each rating and pole count.\u003c\/p\u003e\n\n\u003cdiv style=\"background:#f7f7f9;border-left:4px solid #d42027;padding:16px 18px;margin:28px 0;border-radius:4px;\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0;\"\u003eNeed to switch it by hand as well as automatically? See the \u003ca href=\"\/products\/cnc-ycch7-modular-ac-contactor-manual-override\" style=\"color:#d42027;text-decoration:underline;\"\u003eCNC YCCH7 modular contactor with manual override\u003c\/a\u003e. Browse the full \u003ca href=\"\/collections\/industrial-products\" style=\"color:#d42027;text-decoration:underline;\"\u003eCNC industrial products\u003c\/a\u003e range.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#fff5f5;border:1px solid #f0c9c9;padding:16px 18px;margin:24px 0 0;border-radius:4px;\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.7;margin:0;\"\u003eTell us the load, current and coil voltage and we'll confirm the exact YCCH6 model. \u003cstrong\u003eCNC Electric\u003c\/strong\u003e is the authorised CNC distributor in Pakistan — \u003ca href=\"https:\/\/wa.me\/923261111376\" style=\"color:#d42027;text-decoration:underline;\"\u003emessage us on WhatsApp\u003c\/a\u003e for a price and quote.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n","brand":"CNC","offers":[{"title":"16 A","offer_id":45153523466306,"sku":"YCCH6-16\/11","price":0.0,"currency_code":"PKR","in_stock":true},{"title":"25 A","offer_id":45153523499074,"sku":"YCCH6-25\/11","price":0.0,"currency_code":"PKR","in_stock":true},{"title":"40 A","offer_id":45153523531842,"sku":"YCCH6-40\/11","price":0.0,"currency_code":"PKR","in_stock":true},{"title":"63 A","offer_id":45153523564610,"sku":"YCCH6-63\/11","price":0.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/YCCH6-25-20-600x600.jpg?v=1788507690","url":"https:\/\/www.cncelectric.pk\/products\/cnc-ycch6-modular-ac-contactor","provider":"CNC Electric Pakistan","version":"1.0","type":"link"}