{"product_id":"cnc-4-pole-changeover-switch-100a-ep-series","title":"4 Pole Changeover Switch 100A | EP Series","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003e4 pole changeover switch 100A is the manual transfer switch for panels that need mains and backup selection with neutral switching. Price in Pakistan is Rs.4,000. This EP series unit is built for 0-1-2 source transfer in generator boards, inverter panels, solar backup systems, and industrial distribution panels supplied by \u003ca href=\"\/collections\/changeovers-switch-ep\" style=\"color:#d42027;\"\u003eCNC Electric Pakistan\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e4 pole manual transfer switch, 100A.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e0-1-2 sequence: OFF, mains, generator.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eSwitches neutral plus 3 phases together.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eHeavy-duty copper contacts for repeated manual transfer duty.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eBuilt for panel mounting; useful in backup and solar transfer boards.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eBest when you want manual source control instead of an \u003ca href=\"\/collections\/ats\" style=\"color:#d42027;\"\u003eATS\u003c\/a\u003e.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eType\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eEP manual changeover switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePoles\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e4 pole\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCurrent\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e100A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSequence\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e0-1-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSwitching style\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eManual transfer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eVoltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUp to 440V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eContact material\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHeavy-duty copper contacts\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMounting\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePanel mounted \/ DIN compatible panel layout\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMains-generator, inverter-grid, solar backup source transfer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDetailed drawings \/ terminal map\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eContact us: 0326-1111376\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eVariant\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRating\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrice\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eEP 3 pole\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e20A \/ 32A \/ 63A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.1,650 \/ Rs.1,950 \/ Rs.2,850\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThree-phase manual transfer without switched neutral\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eEP 4 pole\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e63A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.3,500\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMains-generator transfer where neutral must switch too\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eEP 4 pole\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e100A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.4,000\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHeavier home, office, solar, and industrial backup panels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eEP rotary 4 pole\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e63A 0-1-2-3-4\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.3,600\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMulti-position selection where standard 0-1-2 is not enough\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis 100A 4 pole unit is a practical fit for generator panels, solar backup boards, commercial mains-to-generator transfer, and larger inverter source selection. In Faisalabad, it suits backup panels where neutral switching matters on three-phase loads. For home and commercial boards, it is usually paired with \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPDs\u003c\/a\u003e, and upstream \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ecircuit breakers\u003c\/a\u003e.\u003c\/p\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eUse case\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRecommended variant\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThree-phase mains and generator transfer\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e4P 100A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSwitches neutral plus all three phases\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMedium office or commercial backup board\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e4P 100A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMore current headroom than 63A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSmall three-phase workshop\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3P 63A or 4P 63A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDepends on whether switched neutral is required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Choose\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eYour need\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eThis product?\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBetter alternative\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eManual mains-generator transfer with neutral switching\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e—\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAutomatic source transfer\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNo\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e\u003ca href=\"\/collections\/ats\" style=\"color:#d42027;\"\u003eATS\u003c\/a\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eInternal DIN-rail changeover inside a compact board\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually no\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e\u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003eDIN changeover breaker\u003c\/a\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eComparison\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePoint\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCNC EP 4P 100A\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eEP 4P 63A\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eATS 4P 100A\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePrice\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.4,000\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.3,500\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.7,500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOperation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eManual\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eManual\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAutomatic\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCurrent\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e100A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e63A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e100A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eManual backup transfer with switched neutral\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSmaller manual transfer jobs\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAutomatic outage response\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis switch does not regulate voltage, stop surge damage, trip on overload, or transfer power automatically. It is a manual source selector. Use it with the right \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ebreakers\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protectors\u003c\/a\u003e, and \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003esurge protection devices\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation\u003c\/h2\u003e\n  \u003col style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount the switch firmly in the panel.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMark mains, OFF, and generator positions clearly.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eUse correct cable size and torque for the 100A panel design.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eTest source transfer before load handover.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/changeovers-switch-ep\" style=\"color:#d42027;font-weight:700\"\u003eChangeover Switch EP\u003c\/a\u003e for other panel-mounted manual transfer options.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;font-weight:700\"\u003eDIN changeover breakers\u003c\/a\u003e for internal rail-mounted transfer boards.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/ats\" style=\"color:#d42027;font-weight:700\"\u003eAutomatic transfer switches\u003c\/a\u003e for automatic source change.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;font-weight:700\"\u003eVoltage protectors\u003c\/a\u003e for mains fluctuation control.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;font-weight:700\"\u003eVoltage protector finder\u003c\/a\u003e if the backup panel also feeds sensitive loads.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003eSPD\u003c\/a\u003e for surge protection near generator and inverter panels.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003eCircuit breakers\u003c\/a\u003e for upstream protection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;font-weight:700\"\u003eDB boxes\u003c\/a\u003e for complete transfer-panel assembly.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/solar-bundles\" style=\"color:#d42027;font-weight:700\"\u003eSolar bundles\u003c\/a\u003e for inverter and solar-side protection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/news\/changeover-breaker-complete-guide-in-pakistan\" style=\"color:#d42027;\"\u003eChangeover breaker guide\u003c\/a\u003e for panel planning.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/voltage-protector-vs-stabilizer-which-one-does-your-home-actually-need\" style=\"color:#d42027;\"\u003eVoltage protector vs stabilizer\u003c\/a\u003e for backup-load protection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;font-weight:700\"\u003eFire extinguisher products\u003c\/a\u003e as the final panel add-on.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat does 0-1-2 mean?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003e0 is OFF, 1 is mains, 2 is generator.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the price in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eRs.4,000.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhy choose 4 pole instead of 3 pole?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eUse 4 pole when neutral also needs switching.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this automatic?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. It is a manual changeover switch.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan it be used for solar?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, for manual inverter-grid or backup transfer panels.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan it replace an ATS?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eOnly if manual transfer is acceptable.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes it provide surge protection?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. Add an SPD.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eNeed wiring diagram or bulk pricing?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eWhatsApp 0326-1111376.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003e4 pole changeover switch 100A is a strong manual transfer option for mains, generator, inverter, and solar backup panels. For stock, wiring help, and bulk pricing, WhatsApp \u003ca href=\"https:\/\/wa.me\/923261111376\" style=\"color:#d42027;font-weight:700\"\u003e0326-1111376\u003c\/a\u003e. Orders above Rs.10,000 qualify for free delivery.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"100A 0-1-2","offer_id":43011242623042,"sku":null,"price":4100.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Changeover_2_Pole_Switch.webp?v=1770894117","url":"https:\/\/www.cncelectric.pk\/products\/cnc-4-pole-changeover-switch-100a-ep-series","provider":"CNC Electric Pakistan","version":"1.0","type":"link"}