{"title":"Control Panel Parts","description":"\u003cp\u003ePush buttons, indicator lights, selector switches, timers, relays, limit switches, panel fans and thermostats for building and maintaining control panels.\u003c\/p\u003e","products":[{"product_id":"cnc-dc-miniature-relay-24v-compact-reliable-control-1","title":"Miniature Relay 8 Pin 220V AC, 24V DC | Compact \u0026 Reliable Control","description":"\u003cp class=\"MsoNormal\"\u003eThe CNC 8 Pin Miniature Relays are small electrical switches used to control circuits. They have 8 pins for easy connection and are designed to fit into compact spaces. These relays are used in many devices to turn them on or off by sending a small electrical signal. They work well in control panels, automation systems, and electrical equipment. The relays are reliable, long-lasting, and easy to install, making them a good choice for many electronic and industrial applications.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eFeatures of CNC 8 Pin Miniature Relays:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list .5in;\"\u003eCompact 8-pin design for easy installation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list .5in;\"\u003eAvailable in 220V AC and 24V DC versions\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list .5in;\"\u003eHigh-performance coil and contact system\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list .5in;\"\u003eTransparent case for visual inspection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list .5in;\"\u003eSuitable for socket or PCB mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eSpecifications of CNC 8 Pin Miniature Relays:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eVoltage: 220V AC \/ 24V DC\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eType: Power Relay\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003ePin Count: 8\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eContact Configuration: SPDT or DPDT (varies by model)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo2; tab-stops: list .5in;\"\u003eDurable plastic housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eUses:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eIndustrial automation systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eControl panels and machinery\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eElectrical appliances\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eSignal switching in circuits\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo3; tab-stops: list .5in;\"\u003eHVAC systems and lighting controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBenefits:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list .5in;\"\u003eReliable switching performance\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list .5in;\"\u003eEasy to install in compact spaces\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list .5in;\"\u003eSuitable for both AC and DC applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list .5in;\"\u003eLong operational life\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo4; tab-stops: list .5in;\"\u003eReduces the need for manual control systems\u003c\/li\u003e\n\u003c\/ul\u003e For over and under voltage protection, add a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protector\u003c\/a\u003e to your board.\n\u003cdiv style=\"margin-top:15px;font-size:14px\"\u003e\n\u003cstrong\u003e📖 Related Guides:\u003c\/strong\u003e\u003cul style=\"padding-left:18px;margin-top:5px\"\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/contactor-vs-relay-difference-when-to-use-pakistan\" style=\"color:#d42027\"\u003eContactor vs Relay Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/magnetic-contactor-wiring-guide-pakistan-connection-diagram\" style=\"color:#d42027\"\u003eMagnetic Contactor Wiring Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"220V AC","offer_id":42417060642882,"sku":null,"price":800.0,"currency_code":"PKR","in_stock":true},{"title":"24V AC","offer_id":41924526342210,"sku":"dc-miniature-relay-24v","price":950.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/8_Pin_DC_Miniature_Relay_24V.webp?v=1755860234"},{"product_id":"cnc-ac-miniature-relay-220v-compact-reliable-control-1","title":"AC Miniature Relay 220V | Compact \u0026 Reliable Power Control","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eMiniature relay buyers in Pakistan choose the AC Miniature Relay 220V when they need a dependable control relay for switching and automation logic inside panels, not a heavy power contactor and not an improvised loose-wire solution. Starting from Rs.800, this 220V AC relay is used in control circuits for lighting control, HVAC sequencing, panel logic, alarm interlocks, motor control support, timers, thermostats, and simple automation tasks in factories, workshops, commercial sites, and home utility panels.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eQuick Specs\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eProduct\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eAC Miniature Relay 220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eCoil voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e220V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eFormat\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eMiniature control relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eSocket or DIN rail compatible arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eTypical contact use\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLight switching \/ control logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eBest application\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eAutomation and control circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eAlternative to\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLarger contactor on small control tasks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eCategory\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eSwitching \/ control device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA miniature relay is a switching device used in control circuits. It allows one small control signal to open or close another circuit. In simple words, it is one of the basic building blocks of automation. You see it in machine panels, temperature controllers, timer circuits, HVAC logic, small pumps, lighting control, and interlock arrangements. It is cheaper and smaller than a contactor when the actual switching duty is light.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThat difference matters. A \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027\"\u003emagnetic contactor\u003c\/a\u003e is the better choice for heavier motor and power switching. A miniature relay is better when you are handling logic and lighter control duties. In Pakistan, electricians and panel builders often need exactly this kind of part for sequence control, signal duplication, status interlocks, and control isolation inside compact boards.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis is why the AC miniature relay is important even though it looks simple. Many panels fail or become messy because small control parts are replaced with unsafe shortcuts. A proper relay keeps control work neat, serviceable, and easier to troubleshoot later.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTypical Applications in Pakistan\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eCommon uses include timer-based pump start delays with a \u003ca href=\"\/products\/cnc-ah2-n-timer-relay-precise-ic-timer-control\" style=\"color:#d42027\"\u003etimer relay AH2-N\u003c\/a\u003e, thermostat-controlled ventilation or heating logic with a \u003ca href=\"\/products\/cnc-thermostat-temperature-controller-precise-temperature-regulation\" style=\"color:#d42027\"\u003ethermostat temperature controller\u003c\/a\u003e, light control in workshops, changeover logic support, and small motor control commands where the relay controls the coil of a larger contactor.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt is also useful for annunciation and alarms. For example, one status input can energize a relay and trigger a lamp, buzzer, or a second control path. That is why it belongs in professional DB and panel building work across Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSelection Guide\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eUse Case\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eRecommended Product\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSimple automation \/ control logic\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eAC miniature relay\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eCompact and economical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eHeavy motor switching\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eMagnetic contactor\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eRelay is too small for heavy-duty switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eDelay-based switching logic\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eTimer relay + miniature relay\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eLets time and switching functions work together\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eTemperature-based switching\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eThermostat + relay \/ contactor\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eRelay supports the control chain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eNeed fault protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eMCB \/ RCBO \/ SPD as appropriate\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eA relay is not a protection device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Install\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA control relay should be installed by a technician or electrician familiar with relay logic, contact configuration, and coil voltage matching.\u003c\/p\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eConfirm the control circuit voltage is 220V AC before energizing the relay coil.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eMount the relay in its proper socket or DIN rail assembly.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eIdentify coil terminals and NO \/ NC contacts correctly before wiring.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eUse proper ferrules and neat panel wiring to keep future maintenance easy.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eTest pickup, dropout, and contact switching behavior after installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis is a switching and control component, not a protection device. It does not protect against overload or short circuit, so use the correct \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027\"\u003eMCB\u003c\/a\u003e or other breaker. It does not protect against earth leakage, so an \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027\"\u003eRCCB \/ RCBO\u003c\/a\u003e is still required where leakage protection is needed. It does not stop voltage spikes, so sensitive control panels may still need an \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003eSPD\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eMiniature Relay vs Contactor vs Timer Relay\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eMiniature Relay\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eContactor\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eTimer Relay\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMain role\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eControl switching\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003ePower switching\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eTime-delay logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSize\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eSmall\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eLarger\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eSmall \/ control size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eBest for\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eAutomation logic\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMotors and heavier loads\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDelayed operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eCost\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLower\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eHigher\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eUsually higher than simple relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eCan replace the others fully\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCNC vs Other Market Options\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eCNC\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003ePremium imported brands\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eLocal mixed market\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eTypical price in Pakistan\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eRs.800\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eUsually higher\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eVaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eBest value use\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eControl circuits and light switching\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eGood but pricier\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eMay be inconsistent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eVaries\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften unclear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eAvailability with matching automation parts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eDepends\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eScattered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSuitability for Pakistan panels\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eStrong practical option\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eGood but costlier\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eCan be hard to standardize\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCross-Category Recommendations\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIf you are buying an AC miniature relay, also consider the \u003ca href=\"\/products\/cnc-ah2-n-timer-relay-precise-ic-timer-control\" style=\"color:#d42027\"\u003etimer relay AH2-N\u003c\/a\u003e for delayed switching, \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027\"\u003emagnetic contactors\u003c\/a\u003e for heavier load switching, \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027\"\u003ethermal relays\u003c\/a\u003e for motor overload arrangements, and the \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027\"\u003e2P MCB\u003c\/a\u003e for branch protection. In a complete panel, the relay is only one part of the system.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBrowse \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003eAC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027\"\u003eDC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027\"\u003eAC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027\"\u003eDC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027\"\u003eMCCBs\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003eAC SPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027\"\u003eDC SPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-regulator\" style=\"color:#d42027\"\u003evoltage regulators \/ stabilizers\u003c\/a\u003e, \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027\"\u003eRCCB \/ RCBO\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003etypes of circuit breakers\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/solar-db-box-guide-everything-pakistan-installers-need-to-know\" style=\"color:#d42027\"\u003esolar DB guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003etypes of circuit breakers guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/circuit-breaker-trip-curves-explained-b-c-and-d-curve-mcbs\" style=\"color:#d42027\"\u003etrip curves explained\u003c\/a\u003e, \u003ca href=\"\/blogs\/news\/changeover-breaker-complete-guide-in-pakistan\" style=\"color:#d42027\"\u003echangeover guide\u003c\/a\u003e. Even automation panels need proper breaker, surge, and fault-protection selection around the relay logic.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products from CNC Electric\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-ah2-n-timer-relay-precise-ic-timer-control\" style=\"color:#d42027\"\u003eTimer Relay AH2-N\u003c\/a\u003e — Rs.2,300\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027\"\u003eMagnetic Contactors\u003c\/a\u003e — Collection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027\"\u003eThermal Relay\u003c\/a\u003e — Collection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027\"\u003e2 Pole MCB\u003c\/a\u003e — Rs.850\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-thermostat-temperature-controller-precise-temperature-regulation\" style=\"color:#d42027\"\u003eThermostat Temperature Controller\u003c\/a\u003e — Rs.950\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is a miniature relay used for?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA miniature relay is used in control circuits for switching, sequencing, interlocking, and automation logic.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the 220V relay price in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product starts from Rs.800, making it a practical low-cost control component for panels and automation work.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs a miniature relay the same as a contactor?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. A relay is generally for lighter control work, while a contactor is for heavier power switching such as motors and larger loads.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I use this with a timer relay?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. That is a common control combination in panel design, where the timer decides when the relay switches.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan this relay protect my motor?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. It is not a protective device. Use the correct breaker, thermal relay, and contactor arrangement for motor protection.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs it suitable for HVAC and lighting control?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. HVAC sequencing and light control are common uses because the relay is compact and affordable.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this work in Pakistan panel boards?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, it is suited to the kinds of control panels, workshops, and utility boards commonly built across Pakistan.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhy buy from CNC Electric Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBecause you can match the relay with timers, thermostats, contactors, DB boxes, and protection devices from the same overall product ecosystem, with free delivery and 5-year warranty messaging.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eProfessional control panels depend on small reliable parts just as much as on breakers and contactors. CNC Electric Pakistan offers free delivery, 5-year warranty support, and matching automation components for clean panel building. WhatsApp us at 0326-1111376.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n","brand":"CNC ELECTRIC","offers":[{"title":"220V AC","offer_id":41924526374978,"sku":"ac-220v-maniature relay","price":800.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/AC_Miniature_Relay_220V.webp?v=1756100727"},{"product_id":"cnc-ampere-selector-switch-accurate-current-measurement","title":"Ampere Selector Switch 20A LW28 | Accurate Current Measurement","description":"\u003ch2\u003eAmpere Selector Switch 20A — LW28 Series Cam Switch\u003c\/h2\u003e\n\n\u003cp\u003eThe LW28-20 ammeter selector switch lets you read current across all three phases from a single panel-mounted ammeter. Rotate the knob to switch between \u003cstrong\u003eL1, L2, L3, and OFF\u003c\/strong\u003e positions — no need for three separate ammeters on your distribution board.\u003c\/p\u003e\n\n\u003cp\u003eThis is the standard cam-type selector switch used by electricians across Pakistan in \u003cstrong\u003e3-phase DB boxes, industrial panels, and generator control boards\u003c\/strong\u003e. Pair it with a CT (current transformer) and a panel ammeter for accurate per-phase current monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLW28-20\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePositions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (OFF – L1 – L2 – L3)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel mount (22mm cutout)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSilver alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e660V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000+ rotations\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (panel front)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhere It's Used\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3-phase distribution boards\u003c\/strong\u003e — rotate to check amps on each phase without opening the panel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGenerator control panels\u003c\/strong\u003e — monitor load balance across phases\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial motor control centers\u003c\/strong\u003e — quick phase-by-phase current check\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSolar on-grid DB boxes\u003c\/strong\u003e — verify export current per phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWiring Setup\u003c\/h3\u003e\n\u003cp\u003eWire the selector switch between your \u003cstrong\u003e3 CTs (one per phase)\u003c\/strong\u003e and the panel ammeter. In the OFF position, the ammeter circuit is open. Rotate to L1, L2, or L3 to route that phase's CT secondary through the ammeter. Standard wiring diagram included in the box.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Electricians Prefer the LW28\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSolid cam mechanism — no loose contacts after years of daily switching\u003c\/li\u003e\n  \u003cli\u003eSilver alloy contacts — low resistance, accurate readings\u003c\/li\u003e\n  \u003cli\u003eCompact 22mm panel hole — fits standard DB cutouts\u003c\/li\u003e\n  \u003cli\u003eClear position markings — readable even in dim panel enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x LW28-20 ammeter selector switch\u003c\/li\u003e\n  \u003cli\u003e1x mounting nut and hardware\u003c\/li\u003e\n  \u003cli\u003eWiring diagram\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This switch handles the ammeter signal circuit only — it does not carry the main load current. Always use appropriately rated CTs for your system. For voltage selection between phases, see our \u003ca href=\"\/collections\/selector-switch\"\u003eVolt-Ampere Selector Switches\u003c\/a\u003e.\u003c\/p\u003e","brand":"CNC ELECTRIC","offers":[{"title":"20A","offer_id":41924527587394,"sku":"ampare-selector-switch","price":1350.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Ampere_Selector_Switch_Accurate_Current_Measurement.webp?v=1755864537"},{"product_id":"cnc-ah2-n-timer-relay-precise-ic-timer-control","title":"Timer Relay | Precise IC Timer Control for Reliable Switching","description":"\u003cdiv style=\"font-family: system-ui,-apple-system,sans-serif; font-size: 15px; line-height: 1.6; color: #333;\"\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eTimer Relay AH2-N 220V\/30s is a practical timer relay option for Pakistani buyers who want a proper electrical product instead of improvised market stock. Starting from Rs.2,300, it is suited to real use cases in Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar where reliability, neat installation, and future maintenance matter.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: bold; margin-top: 25px; margin-bottom: 10px;\"\u003eQuick Specs\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"background: #f0f0f0; padding: 10px; border: 1px solid #d0d0d0; text-align: left; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background: #f0f0f0; padding: 10px; border: 1px solid #d0d0d0; text-align: left; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003e220V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eTime range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003e0-30 seconds or selected scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eSocket\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003e8-pin relay base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003ePanel or DIN rail base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eUse\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003eMotor control, lighting, HVAC, pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003e5-year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: bold; margin-top: 25px; margin-bottom: 10px;\"\u003eWhat This Product Does\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eAH2-N style delay timer relays are common in Pakistani control work because they solve a simple but important problem: some devices must not switch at exactly the same moment. A controlled delay helps sequence contactors, delay pump restart, stage HVAC devices, and improve automation behavior without a full PLC.\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eThis makes the timer relay useful in workshops, factories, commercial buildings, and machine panels. It is especially common where electricians want a reliable 220V timer relay with a familiar 8-pin base and simple adjustment rather than software programming.\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eIt should be paired with \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color: #d42027;\"\u003emagnetic contactors\u003c\/a\u003e, \u003ca href=\"\/collections\/circuit-breakers\" style=\"color: #d42027;\"\u003eMCBs\u003c\/a\u003e, and proper control wiring, because a timer relay only handles timing logic and not heavy-load fault protection.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: bold; margin-top: 25px; margin-bottom: 10px;\"\u003eSelection Guide\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"background: #f0f0f0; padding: 10px; border: 1px solid #d0d0d0; text-align: left; font-weight: bold;\"\u003eAppliance \/ Load \/ Use Case\u003c\/th\u003e\n\u003cth style=\"background: #f0f0f0; padding: 10px; border: 1px solid #d0d0d0; text-align: left; font-weight: bold;\"\u003eRecommended Rating \/ Variant\u003c\/th\u003e\n\u003cth style=\"background: #f0f0f0; padding: 10px; border: 1px solid #d0d0d0; text-align: left; font-weight: bold;\"\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eMotor star-delta interlock\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003e5-30s delay\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eLets main and star contactors sequence safely\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eStaircase or corridor lights\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003eShort delay relay\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eAdds timed switching without manual guesswork\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eWater pump restart delay\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003e5-20s\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003ePrevents immediate re-energizing after a dip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eHVAC fans and blowers\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003e10-30s\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eImproves staging and sequencing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: bold; margin-top: 25px; margin-bottom: 10px;\"\u003eHow to Install\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eInstallation should always be completed by a licensed electrician, panel builder, or qualified solar installer. Correct cable size, torque, labeling, earthing, and testing matter as much as the product itself.\u003c\/p\u003e\n\u003cul style=\"margin: 10px 0; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 6px;\"\u003eMount the relay socket firmly on panel or compatible rail base.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 6px;\"\u003eWire the supply and control contacts according to the selected timer diagram.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 6px;\"\u003eSet the time range and fine-adjust the dial.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 6px;\"\u003eTest with no critical load first, then verify the sequence with a qualified electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: bold; margin-top: 25px; margin-bottom: 10px;\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eThis timer relay is not a protection device. It does not stop overload, short circuit, earth leakage, surge, or undervoltage by itself. Use proper MCBs, RCBOs, SPDs, and contactors for protection.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: bold; margin-top: 25px; margin-bottom: 10px;\"\u003eCNC vs Schneider \/ Other Brands\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"background: #f0f0f0; padding: 10px; border: 1px solid #d0d0d0; text-align: left; font-weight: bold;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background: #f0f0f0; padding: 10px; border: 1px solid #d0d0d0; text-align: left; font-weight: bold;\"\u003eCNC\u003c\/th\u003e\n\u003cth style=\"background: #f0f0f0; padding: 10px; border: 1px solid #d0d0d0; text-align: left; font-weight: bold;\"\u003eSchneider\u003c\/th\u003e\n\u003cth style=\"background: #f0f0f0; padding: 10px; border: 1px solid #d0d0d0; text-align: left; font-weight: bold;\"\u003eLocal Brands\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eTypical price in Pakistan\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003eRs.2,300\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eUsually significantly higher\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003eVaries, often inconsistent quality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eBranded product family\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003eOften mixed stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003e5-year warranty\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eVaries by channel\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003eOften limited or unclear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eValue for Pakistani buyers\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003eStrong price-to-performance\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003ePremium but expensive\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003eMay be cheap upfront but uncertain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eRelated ecosystem\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003eGood matching accessories and collections\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0;\"\u003eDepends on local availability\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d0d0d0; background: #f9f9f9;\"\u003eOften pieced together from different sellers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: bold; margin-top: 25px; margin-bottom: 10px;\"\u003eCross-Category Recommendations\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eIf you are buying this product, also explore \u003ca href=\"\/collections\/circuit-breakers\" style=\"color: #d42027;\"\u003ecircuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color: #d42027;\"\u003eDC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-breaker\" style=\"color: #d42027;\"\u003eAC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color: #d42027;\"\u003eDC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color: #d42027;\"\u003eMCCB collection\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color: #d42027;\"\u003eAC SPD collection\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-spd\" style=\"color: #d42027;\"\u003eDC SPD collection\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color: #d42027;\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-regulator\" style=\"color: #d42027;\"\u003evoltage regulator \/ stabilizer collection\u003c\/a\u003e, \u003ca href=\"\/collections\/rccb\" style=\"color: #d42027;\"\u003eRCCB and RCBO collection\u003c\/a\u003e, \u003ca href=\"\/collections\/changeovers\" style=\"color: #d42027;\"\u003emanual changeover switches\u003c\/a\u003e, \u003ca href=\"\/collections\/changeovers-switch-ep\" style=\"color: #d42027;\"\u003eEP changeover switches\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color: #d42027;\"\u003etypes of circuit breakers\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/mcb-size-chart-for-pakistan-pick-the-right-breaker-for-every-appliance\" style=\"color: #d42027;\"\u003eMCB size chart for Pakistan\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/circuit-breaker-trip-curves-explained-b-c-and-d-curve-mcbs\" style=\"color: #d42027;\"\u003etrip curves guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/spd-full-form-what-is-surge-protection-device-why-pakistan-needs-it\" style=\"color: #d42027;\"\u003eSPD full form guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/voltage-protector-vs-stabilizer-which-one-does-your-home-actually-need\" style=\"color: #d42027;\"\u003evoltage protector vs stabilizer\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/solar-db-box-guide-everything-pakistan-installers-need-to-know\" style=\"color: #d42027;\"\u003esolar DB box guide\u003c\/a\u003e, \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color: #d42027;\"\u003eMagnetic Contactors\u003c\/a\u003e, \u003ca href=\"\/collections\/db-boxes\" style=\"color: #d42027;\"\u003eDB Boxes\u003c\/a\u003e. These links help buyers compare the right category before ordering instead of treating every electrical product as if it does the same job.\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eUseful related options include \u003ca href=\"\/products\/cnc-ac-miniature-relay-220v-compact-reliable-control-1\" style=\"color: #d42027;\"\u003eMiniature Relay\u003c\/a\u003e Rs.800, \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color: #d42027;\"\u003eMagnetic Contactors\u003c\/a\u003e, \u003ca href=\"\/products\/cnc-thermostat-temperature-controller-precise-temperature-regulation\" style=\"color: #d42027;\"\u003eThermostat Temperature Controller\u003c\/a\u003e Rs.950, \u003ca href=\"\/collections\/db-boxes\" style=\"color: #d42027;\"\u003eDB Boxes\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: bold; margin-top: 25px; margin-bottom: 10px;\"\u003eRelated Products from CNC Electric\u003c\/h2\u003e\n\u003cul style=\"margin: 10px 0; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003ca href=\"\/products\/cnc-ac-miniature-relay-220v-compact-reliable-control-1\" style=\"color: #d42027;\"\u003eMiniature Relay\u003c\/a\u003e — Rs.800\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 6px;\"\u003e\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color: #d42027;\"\u003eMagnetic Contactors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003ca href=\"\/products\/cnc-thermostat-temperature-controller-precise-temperature-regulation\" style=\"color: #d42027;\"\u003eThermostat Temperature Controller\u003c\/a\u003e — Rs.950\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 6px;\"\u003e\u003ca href=\"\/collections\/db-boxes\" style=\"color: #d42027;\"\u003eDB Boxes\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: bold; margin-top: 25px; margin-bottom: 10px;\"\u003eWhy Pakistani Buyers Choose This Product\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eControl products are often ignored during planning, yet they are what turn a rough electrical job into a professional panel. They add logic, sequencing, and repeatability, which reduces nuisance problems and makes the system easier to understand later.\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eThat is why workshops, factories, commercial buildings, and panel builders across Pakistan keep using familiar DIN rail control accessories. They are simple, serviceable, and easy for electricians to troubleshoot.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: bold; margin-top: 25px; margin-bottom: 10px;\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 style=\"font-size: 17px; font-weight: bold; margin-top: 20px; margin-bottom: 8px;\"\u003eWhat is the timer relay price in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eThis product starts from Rs.2,300. CNC Electric Pakistan sells across Pakistan with free delivery and a 5-year warranty.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 17px; font-weight: bold; margin-top: 20px; margin-bottom: 8px;\"\u003eIs this available in Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar?\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eYes. The product is intended for buyers across Pakistan and can be compared online before ordering.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 17px; font-weight: bold; margin-top: 20px; margin-bottom: 8px;\"\u003eCan a normal electrician install it?\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eA qualified electrician or solar installer should handle installation so cable size, torque, labeling, and protection coordination are correct.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 17px; font-weight: bold; margin-top: 20px; margin-bottom: 8px;\"\u003eHow do I choose the right size or variant?\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eUse the selection guide in this description as a starting point, then confirm the final rating from the actual load current, system voltage, string count, and site conditions.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 17px; font-weight: bold; margin-top: 20px; margin-bottom: 8px;\"\u003eIs CNC better than cheap local alternatives?\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eCNC Electric Pakistan is usually chosen because it offers branded products, coordinated related items, clearer specifications, free delivery, and a 5-year warranty.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 17px; font-weight: bold; margin-top: 20px; margin-bottom: 8px;\"\u003eDoes this replace every other protection device?\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eNo. Good electrical design uses each product for its actual purpose. Breakers, RCBOs, SPDs, voltage protectors, fuses, timers, and connectors all do different jobs.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 17px; font-weight: bold; margin-top: 20px; margin-bottom: 8px;\"\u003eCan I use this in solar installations?\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eIn many cases yes. Final selection should still be matched to the real design.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 17px; font-weight: bold; margin-top: 20px; margin-bottom: 8px;\"\u003eWhy buy from CNC Electric Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eBecause buyers want a practical price in Pakistan, matching accessories, and a complete ecosystem instead of mixing unknown parts from multiple sellers.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 17px; font-weight: bold; margin-top: 20px; margin-bottom: 8px;\"\u003eWhat is AH2-N timer relay used for?\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eIt is used where a controlled time delay is needed before a contact opens or closes, such as motor panels, pumps, lighting, HVAC sequencing, and small automation jobs.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 17px; font-weight: bold; margin-top: 20px; margin-bottom: 8px;\"\u003eCan I use this instead of a contactor?\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eNo. A timer relay controls logic and timing. Heavy load switching should still be handled by a proper contactor or relay matched to the load current.\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 12px;\"\u003eFor system planning, compare the linked collections and guides above, then order the right matched components instead of guessing. CNC Electric Pakistan offers free delivery and a 5-year warranty. WhatsApp us at 0326-1111376.\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 8px;\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/timer-switch-guide-pakistan-digital-timer-relay-types-wiring\" style=\"color: #d42027;\"\u003eTimer Switch Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"220V\/30 Sec \/ Time Relay","offer_id":41924527980610,"sku":"AH2-N","price":2000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/AH2-N_Timer_Relay.webp?v=1755864438"},{"product_id":"cnc-xj3-d-3-phase-sequence-relay-reliable-phase-protection","title":"3 Phase Sequence Relay | Reliable Phase Protection \u0026 Monitoring","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003ePhase sequence relay is the right protection device when a three-phase motor must never run with a missing phase or the wrong phase order. On CNC Electric Pakistan, this XJ3-D listing is shown at Rs.3,500, so it sits in the practical industrial-control range rather than the expensive protection-relay category. For pumps, compressors, chillers, lifts, textile machines and workshop motors in Pakistan, this relay helps stop the contactor circuit before reverse rotation, single phasing or unstable three-phase conditions damage equipment.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product matters most on sites where three-phase supply is not always clean and predictable. After load shedding, generator changeover, maintenance rewiring or feeder disturbance, a motor can see the wrong phase sequence or lose one phase completely. A motor may hum, run hot, pull unbalanced current, or rotate the wrong direction. A phase sequence relay is meant to stop that problem before the contactor pulls in fully and the machine turns a voltage mistake into a repair bill.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eThree-phase monitoring for \u003cstrong\u003ephase failure\u003c\/strong\u003e, \u003cstrong\u003ewrong phase sequence\u003c\/strong\u003e, \u003cstrong\u003eovervoltage\u003c\/strong\u003e and \u003cstrong\u003eundervoltage\u003c\/strong\u003e conditions.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eLocal CNC Electric Pakistan listing price is \u003cstrong\u003eRs.3,500\u003c\/strong\u003e for the XJ3-D phase protection relay.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eDesigned to control the contactor coil circuit so the motor load is not allowed to run under unsafe phase conditions.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eOfficial family data shows \u003cstrong\u003eAC 380V, 50\/60Hz\u003c\/strong\u003e operating voltage for this relay class.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eAdjustable overvoltage and undervoltage window makes it more useful than a basic phase-loss-only relay.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eSuitable for control panels using \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003emagnetic contactors\u003c\/a\u003e, \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003ethermal relays\u003c\/a\u003e and upstream \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ecircuit breakers\u003c\/a\u003e.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e35mm rail mounting support in official family data helps it fit cleanly in many industrial panels and \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB boxes\u003c\/a\u003e.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProduct listing\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3 Phase Sequence Relay | Reliable Phase Protection \u0026amp; Monitoring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eModel sold locally\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eXJ3-D\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLocal sale price\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.3,500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProtection functions\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOvervoltage, undervoltage, phase failure, phase sequence error\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOperating voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAC 380V, 50\/60Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOvervoltage range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e380V to 460V, 1.5s to 4s adjustable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUndervoltage range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e300V to 380V, 2s to 9s adjustable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePhase failure \/ sequence reaction time\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e≤2 seconds\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eContact form\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1 group changeover contact\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eContact capacity\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUe\/Ie AC-15 380V \/ 0.47A; Ith 3A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eElectrical life\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1×10\u003csup\u003e5\u003c\/sup\u003e operations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMechanical life\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1×10\u003csup\u003e6\u003c\/sup\u003e operations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAmbient temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e-5°C to +40°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eInstallation mode\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e35mm rail installation or soleplate mounting\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range and Price\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eModel\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eSupply monitored\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eProtection type\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrice\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eXJ3-D\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3 phase AC 380V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePhase failure, wrong sequence, under\/overvoltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.3,500\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis description uses only data published on the live product page plus official family data that clearly fits the XJ3-D relay class. A full local wiring diagram, exact terminal numbering for the sale listing, and enclosure dimensions are not currently listed on the live Pakistan page and have not been guessed.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications — Where to Use This Phase Sequence Relay\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis relay belongs in three-phase control panels where motor direction and balanced supply matter. In Faisalabad, it makes sense on textile machines, compressors and process motors where wrong phase order after maintenance can stop production or run equipment backwards. In Lahore, it suits workshops, chillers, pumps and machine-control panels where electricians often deal with generator changeover and mixed-site power conditions. In Karachi, plant rooms, HVAC systems and utility motors can benefit because phase failure or wrong sequence is not something you want the contactor to discover after the motor has already been energized.\u003c\/p\u003e\n\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eApplication\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy a phase sequence relay helps\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhat it protects against\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWater pumps and booster sets\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStops the control circuit if the supply loses a phase or comes back in the wrong order\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDry run direction problems, hot running, nuisance motor stress\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCompressors and chillers\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMaintains safer start permission after phase disturbance\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eReverse rotation and low-voltage coil problems\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTextile and process lines\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProtects motors after rewiring, generator transfer or supply anomalies\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWrong phase sequence after maintenance\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLifts, hoists and travel motors\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAdds control-side protection where direction matters\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIncorrect rotation and unstable three-phase supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGenerator-backed industrial panels\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHelps the panel reject unsafe phase conditions before contactor pickup\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBad phase order or a missing phase after changeover\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Choose the Right Phase Protection Device\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe first question is simple: do you only need motor overload protection, or do you also need to verify that all three phases are healthy and in the correct order before the motor runs? If the site runs three-phase motors where direction matters, overload alone is not enough. If the site has frequent maintenance, generator backup, or voltage irregularity, a relay with phase-failure and under\/overvoltage logic is the better choice.\u003c\/p\u003e\n\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eYour panel situation\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eUse this relay?\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThree-phase motor with direction-sensitive rotation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWrong phase order can reverse motor direction\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOnly need overload protection on a motor starter\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNot alone\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYou still need a \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003ethermal overload relay\u003c\/a\u003e for current overload protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSite has generator backup or frequent supply disturbance\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSupply changeovers increase the value of phase and voltage checking\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSingle-phase load only\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNo\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThis product is for three-phase control logic\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003ePhase Sequence Relay vs Other Protection Devices — Why CNC?\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eDevice\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhat it does well\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhat it does not replace\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCNC phase sequence relay\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eChecks phase order, phase loss, undervoltage and overvoltage before allowing the control circuit to hold\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDoes not replace overload, breaker or surge protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOnly thermal overload relay\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProtects against motor overcurrent and overload heating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCannot detect wrong phase sequence before motor start\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOnly voltage protector\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUseful for over\/under voltage on sensitive loads\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually not designed to verify three-phase sequence logic for motor control\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis phase sequence relay does not replace upstream short-circuit protection, motor overload protection, leakage protection, or surge protection. It cannot do the job of a \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ecircuit breaker\u003c\/a\u003e, an \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCCB \/ RCBO\u003c\/a\u003e, or a \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003ethermal overload relay\u003c\/a\u003e. It is a control-side monitoring relay. Its job is to stop unsafe three-phase conditions from energizing the contactor circuit in the first place.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt also does not protect against lightning or switching surges. If your control panel is near motors, long cable runs, generator switching or outdoor feeders, add a proper \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003esurge protection device\u003c\/a\u003e. If the site has recurring low and high mains swings, pair the panel with the correct \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protector\u003c\/a\u003e where relevant.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n  \u003col style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount the relay on a 35mm DIN rail or approved panel base according to your panel layout.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eBring the three monitored phases to the relay exactly as shown on the wiring diagram supplied with the product or official instruction manual.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eWire the output contact into the \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003econtactor\u003c\/a\u003e coil control path so the motor cannot start under bad phase conditions.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eSet the required overvoltage and undervoltage thresholds only after confirming the supply conditions of your site and the motor panel design.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eTest healthy supply, missing phase and wrong sequence conditions before handing over the panel.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"margin-top:25px;padding:15px;background:#f9f9f9;border:1px solid #e0e0e0;border-radius:5px;\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin-bottom:10px;line-height:1.6\"\u003eComplete Your Electrical Setup\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;line-height:1.6\"\u003e⚡ \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSurge Protection Devices (SPD)\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;line-height:1.6\"\u003e🔌 \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003eVoltage Protectors\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;line-height:1.6\"\u003e📦 \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB Boxes\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:0;line-height:1.6\"\u003e📖 \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eGuide: Types of Circuit Breakers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px\"\u003e⚡ \u003ca href=\"\/collections\/capacitor-banks\" style=\"color:#d42027\"\u003eCapacitor Banks\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis relay normally belongs inside a wider motor or control panel. Buyers usually pair it with \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003emagnetic contactors\u003c\/a\u003e, \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003ethermal overload relays\u003c\/a\u003e, upstream \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027;\"\u003eAC breakers\u003c\/a\u003e or \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;\"\u003epush buttons\u003c\/a\u003e, \u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;\"\u003eselector switches\u003c\/a\u003e, \u003ca href=\"\/collections\/indicator-lights\" style=\"color:#d42027;\"\u003eindicator lights\u003c\/a\u003e, and where mains quality is poor, a proper \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;\"\u003evoltage protector finder tool\u003c\/a\u003e to select the right protection strategy. For supporting reading, see the \u003ca href=\"\/blogs\/news\/changeover-breaker-complete-guide-in-pakistan\" style=\"color:#d42027;\"\u003eChangeover Breaker Guide\u003c\/a\u003e, the \u003ca href=\"\/blogs\/news\/ac-mccb-breaker-complete-guide-to-moulded-case-circuit-breaker-features-applications\" style=\"color:#d42027;\"\u003eMCCB Guide\u003c\/a\u003e, and the \u003ca href=\"\/blogs\/guides\/rccb-breaker-guide-pakistan-earth-leakage-protection\" style=\"color:#d42027;\"\u003eSafety Breaker Guide\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat does a phase sequence relay do?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt checks whether all three phases are present and in the correct order before or during control operation. If phase order is wrong or a phase fails, it drops or blocks the control circuit.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhy is wrong phase sequence dangerous?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eMany three-phase motors will reverse direction if the phase order is changed. That can damage pumps, conveyors, compressors, lifts and process machinery.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan this relay protect against phase failure?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. The official XJ3-D family data specifically includes phase-failure protection and phase-sequence error protection.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this the same as a thermal overload relay?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. A thermal overload relay protects a motor from overload current. A phase sequence relay checks the health and order of the three-phase supply feeding the control circuit.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the price of this phase sequence relay in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eAt the time checked, CNC Electric Pakistan listed this XJ3-D phase sequence relay at Rs.3,500.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs a phase sequence relay worth the price in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIf you run three-phase motors with generator backup, frequent maintenance, or unreliable supply conditions, yes. One wrong-sequence startup can cost far more than the relay.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I install it in a DB or control panel on DIN rail?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. Official family data allows 35mm track installation or soleplate mounting, which suits many motor-control panels.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this relay replace surge protection or a voltage protector?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. It monitors three-phase condition and phase order. Use the proper \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e for surge risk and the right \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protector\u003c\/a\u003e where voltage fluctuation is the main problem.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNeed help choosing the right protection relay or building the full three-phase panel around it? Contact CNC Electric Pakistan on WhatsApp \u003cstrong\u003e0326-1111376\u003c\/strong\u003e for selection help, price confirmation and matching products. Orders above Rs.10,000 qualify for free delivery, and you can pair this relay with contactors, overload relays, breakers, SPDs and panel accessories from the same store.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"3 Phase","offer_id":41924531880002,"sku":"XJ3-D","price":3500.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/XJ3-D_3_Phase_Sequence_Relay.webp?v=1756100288"},{"product_id":"cnc-thermostat-temperature-controller-precise-temperature-regulation","title":"Thermostat for Panel Fan KTS011 0–60°C (Blue, NO)","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cdiv style=\"background:#f6f6f6;border-left:3px solid #1f6fd1;padding:12px 14px;margin:0 0 16px\"\u003e\n\u003cstrong\u003eFor a panel cooling fan.\u003c\/strong\u003e This is the \u003cstrong\u003eKTS011 (blue dial)\u003c\/strong\u003e — normally open: it switches the fan ON when the panel gets hotter than your setting and OFF again when it cools down.\u003cbr\u003e\n\u003cspan style=\"font-size:13px;color:#666\"\u003eNeed to switch a panel heater instead? Use the \u003ca href=\"\/products\/cnc-thermostat-temperature-controller-reliable-heat-control\" style=\"color:#d42027\"\u003eKTO011 (red dial) heater thermostat\u003c\/a\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe CNC KTS011 is a small DIN-rail thermostat for electrical panels and enclosures. Set the dial between 0 and 60°C. While the panel is cooler than the setting, the contact stays open and the fan is off; when the panel heats up to the setting, the contact closes and the fan runs. This keeps breakers, drives and electronics from overheating in summer.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eKTS011 (blue dial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eContact\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eNormally open (NO) — closes when temperature rises\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSetting range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e0 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSwitching capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e250V AC 10A · 120V AC 15A · DC 30W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSwitching difference\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eAbout 7°C (±4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e35mm DIN rail clip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eService life\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMore than 100,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e−45 to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhich thermostat do I need?\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:10px;border:1px solid #d0d0d0;background:#f0f0f0;text-align:left\"\u003eYou want to\u003c\/th\u003e\n\u003cth style=\"padding:10px;border:1px solid #d0d0d0;background:#f0f0f0;text-align:left\"\u003eChoose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eRun a cooling fan when the panel gets hot\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e\u003cstrong\u003eKTS011 — this product (blue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eRun a heater when the panel is cold\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e\u003ca href=\"\/products\/cnc-thermostat-temperature-controller-reliable-heat-control\" style=\"color:#d42027\"\u003eKTO011 heater thermostat (red)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to install\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli\u003eClip it on the DIN rail in the upper part of the panel, where hot air collects.\u003c\/li\u003e\n\u003cli\u003eWire the thermostat contact in series with the fan supply.\u003c\/li\u003e\n\u003cli\u003eFans or loads above 10A at 250V: let the thermostat switch a contactor or relay coil instead.\u003c\/li\u003e\n\u003cli\u003eSet the dial and check the fan switches as expected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis is a control device, not a protection device — it does not protect against overload, short circuit or surges. Use a proper breaker on the circuit.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the difference between the blue and red thermostat?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBlue (KTS011) is normally open and is used for fans. Red (KTO011) is normally closed and is used for heaters.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eThermostat or timer — which do I need?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA thermostat switches on temperature. A timer switches on time. For a panel fan that should run only when it is hot, use this thermostat.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNeed help choosing? WhatsApp us at 0326-1111376.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"0-60C","offer_id":41924531978306,"sku":"thermostate-temp-controller","price":950.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Thermostat_Temperature_Controller-7.webp?v=1756118820"},{"product_id":"cnc-thermostat-temperature-controller-reliable-heat-control","title":"Thermostat for Panel Heater KTO011 0–60°C (Red, NC)","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cdiv style=\"background:#f6f6f6;border-left:3px solid #d71920;padding:12px 14px;margin:0 0 16px\"\u003e\n\u003cstrong\u003eFor a panel heater.\u003c\/strong\u003e This is the \u003cstrong\u003eKTO011 (red dial)\u003c\/strong\u003e — normally closed: it keeps the heater ON while the panel is cold and switches it OFF when the temperature rises to your setting.\u003cbr\u003e\n\u003cspan style=\"font-size:13px;color:#666\"\u003eNeed to switch a cooling fan instead? Use the \u003ca href=\"\/products\/cnc-thermostat-temperature-controller-precise-temperature-regulation\" style=\"color:#d42027\"\u003eKTS011 (blue dial) fan thermostat\u003c\/a\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe CNC KTO011 is a small DIN-rail thermostat for electrical panels and enclosures. Set the dial between 0 and 60°C. While the panel is colder than the setting, the contact stays closed and your heater runs; when the panel warms up to the setting, the contact opens and the heater stops. This keeps panels dry and protects electronics from cold and condensation.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eKTO011 (red dial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eContact\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eNormally closed (NC) — opens when temperature rises\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSetting range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e0 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSwitching capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e250V AC 10A · 120V AC 15A · DC 30W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSwitching difference\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eAbout 7°C (±4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e35mm DIN rail clip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eService life\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMore than 100,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e−45 to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhich thermostat do I need?\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:10px;border:1px solid #d0d0d0;background:#f0f0f0;text-align:left\"\u003eYou want to\u003c\/th\u003e\n\u003cth style=\"padding:10px;border:1px solid #d0d0d0;background:#f0f0f0;text-align:left\"\u003eChoose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eRun a heater when the panel is cold\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e\u003cstrong\u003eKTO011 — this product (red)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eRun a cooling fan when the panel gets hot\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e\u003ca href=\"\/products\/cnc-thermostat-temperature-controller-precise-temperature-regulation\" style=\"color:#d42027\"\u003eKTS011 fan thermostat (blue)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to install\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli\u003eClip it on the DIN rail, away from the heater itself.\u003c\/li\u003e\n\u003cli\u003eWire the thermostat contact in series with the heater supply.\u003c\/li\u003e\n\u003cli\u003eHeaters above 10A at 250V: let the thermostat switch a contactor or relay coil instead.\u003c\/li\u003e\n\u003cli\u003eSet the dial and check the heater switches as expected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis is a control device, not a protection device — it does not protect against overload, short circuit or surges. Use a proper breaker on the circuit.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the difference between the red and blue thermostat?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eRed (KTO011) is normally closed and is used for heaters. Blue (KTS011) is normally open and is used for fans.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan it switch my heater directly?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, up to 10A at 250V AC. For bigger heaters, use it to switch a contactor.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNeed help choosing? WhatsApp us at 0326-1111376.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"0-60C","offer_id":41924532011074,"sku":"thermostate-heat-control","price":950.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Thermostat_Temperature_Controller-3.webp?v=1756118736"},{"product_id":"cnc-weekly-digital-timer-tp8a16","title":"Digital Weekly Timer 220V 30A | Efficient Load \u0026 Power Management","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe Digital Weekly Timer 200V 30A TP8A16 is a programmable \u003cstrong\u003edigital timer\u003c\/strong\u003e for buyers who need full-week ON\/OFF scheduling in Pakistan. Starting from Rs.2,850, this \u003cstrong\u003eweekly timer\u003c\/strong\u003e lets you automate street lights, sign boards, shop lighting, water pumps, geysers, AC routines, and selected industrial equipment by day and time instead of by guesswork. For electricians and facility managers in Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar, it is a more flexible answer than a simple delay timer relay.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eQuick Specs\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eProduct\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDigital Weekly Timer TP8A16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eHandle \/ Model\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003ecnc-weekly-digital-timer-tp8a16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eOperating Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e200V class weekly digital timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eFunction\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eProgrammable ON\/OFF scheduling through the week\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eTypical Uses\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLights, pumps, geysers, AC routines, sign boards, equipment timing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003ePanel \/ DIN rail compatible installation approach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eControl Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eClock-based weekly scheduling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty from CNC Electric Pakistan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product gives you a true weekly schedule, not just a single delay. That is the biggest difference. A \u003ca href=\"\/products\/cnc-ah2-n-timer-relay-precise-ic-timer-control\" style=\"color:#d42027\"\u003etimer relay AH2-N\u003c\/a\u003e is useful when you need seconds or minutes of delay after a trigger. The TP8A16 is different: it lets you decide on which day and at what time the load should turn ON or OFF. That is why it works well for repeated weekly jobs such as market sign boards, school bells, office lights, mosque lighting, pump routines, and geyser scheduling.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIn practical Pakistan use, the most common waste comes from loads that stay ON longer than needed. Street lights stay ON in daylight, pumps keep running, sign boards are left ON after closing time, and geysers or AC circuits continue consuming power because someone forgot to switch them. A \u003cstrong\u003eprogrammable timer\u003c\/strong\u003e solves that problem by turning habit-based control into schedule-based control.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt also helps separate different product roles. A thermostat responds to heat. A relay responds to an electrical signal. A weekly timer responds to time and day. So if your problem is “this load should run every evening from 6 PM to 10 PM” or “this pump should operate on a repeating schedule,” then a \u003cstrong\u003eweekly digital timer\u003c\/strong\u003e is often the correct device.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhere a Weekly Timer Fits Best\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe keyword \u003cstrong\u003edigital timer price in pakistan\u003c\/strong\u003e is small but valuable because buyers searching for it usually have an actual scheduling problem to solve. Typical users include shop owners managing display lights, schools automating bells, warehouses controlling ventilation windows, households scheduling geysers, and panel builders creating low-cost automation without a PLC.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt is especially useful when paired with \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027\"\u003emagnetic contactors\u003c\/a\u003e or \u003ca href=\"\/products\/cnc-ac-miniature-relay-220v-compact-reliable-control-1\" style=\"color:#d42027\"\u003eminiature relays\u003c\/a\u003e for safer switching. The timer provides the schedule; the relay or contactor can carry the switching duty. Inside a neat \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027\"\u003eDB box\u003c\/a\u003e or control panel, this creates a much cleaner system than manual switching.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSchedule Selection Guide\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eAppliance \/ Load \/ Use Case\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eRecommended Setup\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eStreet lights \/ facade lights\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eWeekly timer + contactor where needed\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eTurns lights ON\/OFF automatically every evening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eShop sign board\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eWeekly timer only or timer + relay\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eAvoids all-night power waste after closing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWater pump routine\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eWeekly timer + contactor if motor load is larger\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eUseful for repeat irrigation or filling schedules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eGeyser timing\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eWeekly timer on dedicated safe control line\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eAllows fixed daily morning\/evening schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eAC routine in office\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eWeekly timer controlling allowed hours\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eStops after-hours energy waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSmall industrial sequence\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eWeekly timer with relay logic\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eUseful where routine weekly switching matters more than sensor control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWeekly Timer vs Delay Timer vs Thermostat\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eWeekly Digital Timer TP8A16\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eAH2-N Delay Timer\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eThermostat Controller\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMain trigger\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDay and time\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eDelay after signal\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eTemperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eBest use\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eRoutine schedules\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eStart \/ stop delay\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eHeat-based control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eGood for geyser schedule\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eGood for motor delay\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eGood for panel cooling fan by temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eBest buyer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eShops, offices, homes, sign boards\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003ePanel builders, sequencing jobs\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eHeating \/ cooling applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Install\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA licensed electrician should install the timer, especially if it is controlling pumps, contactors, or fixed building loads.\u003c\/p\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eMount the timer securely in the panel or on DIN rail as required by the installation arrangement.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eConnect supply and output terminals according to the wiring diagram.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eSet the correct time, day, and weekly program before energizing the load.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eIf the controlled load is large, use the timer to trigger a relay or contactor instead of carrying the full load directly.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eTest all ON and OFF events before handing the system over to the customer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis timer is not a protection device. It does not replace \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003eMCBs\u003c\/a\u003e for overload and short circuit, does not replace \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027\"\u003eRCCB \/ RCBO\u003c\/a\u003e for shock protection, does not replace \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003eSPDs\u003c\/a\u003e for lightning and surge protection, and does not replace \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protectors\u003c\/a\u003e for over voltage protection. It is only for programmed switching by day and time.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCNC vs Schneider and Local Brands\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eCNC\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSchneider\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eLocal Brands\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003ePrice in Pakistan\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eRs.2,850\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eUsually higher for similar programmable timer functions\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eCan be cheaper but often inconsistent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eProgramming value\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eStrong weekly scheduling at practical cost\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003ePremium range, higher total cost\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften basic or unclear manuals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003ePanel ecosystem\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eEasy to pair with CNC relays, contactors, DB boxes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eGood but premium-priced\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften mixed brands in one panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eUsually shorter or distributor dependent\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften unclear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eValue for Pakistani buyers\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eStrong balance of function and price\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003ePremium budget option\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLower cost but variable support and documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCross-Category Recommendations\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIf you are buying this \u003cstrong\u003eweekly timer\u003c\/strong\u003e, also consider \u003ca href=\"\/products\/cnc-ah2-n-timer-relay-precise-ic-timer-control\" style=\"color:#d42027\"\u003eTimer Relay AH2-N\u003c\/a\u003e Rs.2,300, \u003ca href=\"\/products\/cnc-thermostat-temperature-controller-precise-temperature-regulation\" style=\"color:#d42027\"\u003eThermostat Temperature Controller\u003c\/a\u003e Rs.950, \u003ca href=\"\/products\/cnc-ac-miniature-relay-220v-compact-reliable-control-1\" style=\"color:#d42027\"\u003eMiniature Relay 220V\u003c\/a\u003e Rs.800, and \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027\"\u003emagnetic contactors\u003c\/a\u003e for heavier switching. For complete panel work, browse \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003eAC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027\"\u003eDC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027\"\u003eAC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027\"\u003eDC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027\"\u003eMCCBs\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003eAC SPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027\"\u003eDC SPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-regulator\" style=\"color:#d42027\"\u003evoltage regulators \/ stabilizers\u003c\/a\u003e, \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027\"\u003eRCCB \/ RCBO\u003c\/a\u003e, \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027\"\u003emanual changeover switches\u003c\/a\u003e, \u003ca href=\"\/collections\/ats\" style=\"color:#d42027\"\u003eautomatic transfer switches\u003c\/a\u003e, \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027\"\u003eDB boxes\u003c\/a\u003e. For learning and related buying paths, explore \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003etypes of circuit breakers\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/mcb-size-chart-for-pakistan-pick-the-right-breaker-for-every-appliance\" style=\"color:#d42027\"\u003eMCB size chart for Pakistan\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/circuit-breaker-trip-curves-explained-b-c-and-d-curve-mcbs\" style=\"color:#d42027\"\u003etrip curves explained\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/spd-full-form-what-is-surge-protection-device-why-pakistan-needs-it\" style=\"color:#d42027\"\u003eSPD full form guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/voltage-protector-vs-stabilizer-which-one-does-your-home-actually-need\" style=\"color:#d42027\"\u003evoltage protector vs stabilizer\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/solar-db-box-guide-everything-pakistan-installers-need-to-know\" style=\"color:#d42027\"\u003esolar DB box guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/news\/changeover-breaker-complete-guide-in-pakistan\" style=\"color:#d42027\"\u003echangeover guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/mcb-full-form-what-is-mcb-miniature-circuit-breaker-working-principle-types\" style=\"color:#d42027\"\u003eMCB vs MCCB guide\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products from CNC Electric\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-ah2-n-timer-relay-precise-ic-timer-control\" style=\"color:#d42027\"\u003eTimer Relay AH2-N\u003c\/a\u003e — Rs.2,300\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-thermostat-temperature-controller-precise-temperature-regulation\" style=\"color:#d42027\"\u003eThermostat Temperature Controller\u003c\/a\u003e — Rs.950\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-ac-miniature-relay-220v-compact-reliable-control-1\" style=\"color:#d42027\"\u003eAC Miniature Relay 220V\u003c\/a\u003e — Rs.800\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027\"\u003eMagnetic Contactors\u003c\/a\u003e — See collection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027\"\u003eDB Boxes\u003c\/a\u003e — See collection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the digital timer price in Pakistan for TP8A16?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe digital timer price in Pakistan for this TP8A16 model starts from Rs.2,850. It is a weekly scheduler, not just a simple delay timer.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the difference between a weekly timer and a delay timer?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA weekly timer follows day-by-day clock schedules. A delay timer waits seconds or minutes after a trigger. They solve different problems.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I use this digital timer for a geyser?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, many buyers use a weekly timer for geyser scheduling so the heater only runs during fixed morning and evening windows. A qualified electrician should verify the switching arrangement.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this useful for shop sign boards and street lights?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. That is one of the most common use cases. It helps turn signs and lights ON at the right time and OFF after business hours.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan it control a water pump?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, but where the pump load is significant, the timer should usually control a relay or contactor rather than switching a large motor load directly.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this the same as a thermostat controller?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. A thermostat responds to temperature. This weekly timer responds to time and day schedules.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this timer provide overload or surge protection?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. It is only a switching and scheduling device. Use MCBs, RCBOs, SPDs, and voltage protectors separately.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs it available across Pakistan with free delivery?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. CNC Electric Pakistan offers free delivery across Pakistan, including Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhy buy a CNC weekly timer instead of a local generic timer switch?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBecause you get a 5-year warranty, a cleaner matched panel ecosystem, and easier access to related products like relays, contactors, and DB boxes from one supplier.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eCNC Electric Pakistan offers free delivery across Pakistan, a 5-year warranty, and coordinated products for panel building, automation, and scheduled switching. WhatsApp us at 0326-1111376.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:8px\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/timer-switch-guide-pakistan-digital-timer-relay-types-wiring\" style=\"color:#d42027\"\u003eTimer Switch Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n---","brand":"CNC Electric Pakistan","offers":[{"title":"220V \/ 30A","offer_id":42324143636546,"sku":"TP8A16","price":2800.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Weekly_Digital_Timer_TP8A16.webp?v=1755861173"},{"product_id":"cnc-din-rail-3-phase-multi-color-indication-light-ycd9-3","title":"3 Phase Din Rail Indicator Lights | Green, Yellow, Red Signaling","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eDIN rail indicator light is one of the simplest but most useful parts inside a control panel. This 3 phase DIN rail indicator light is listed in Pakistan at Rs.400 and uses red, yellow, and green visual indication for three-phase status monitoring. If you build DBs, generator panels, machine-control boards, or small industrial enclosures, this product gives a quick visual check without opening the whole system or connecting a test meter every time.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe live CNC Electric Pakistan listing presents it as a 220V DIN-rail panel indicator for control panels, electrical distribution boards, and automation systems. The same page highlights three color LED indication, DIN rail mounting, low power consumption, and a flame-retardant housing for routine panel use. That makes this a practical status-indication device rather than a measuring instrument. Its job is to show condition quickly and clearly.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eThree-color visual indication in one DIN rail module: red, yellow, and green.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eLocal sale page shows 220V input for standard panel indication duty.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eDesigned for control panels, DBs, automation boards, and industrial signaling use.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eDIN rail mounting keeps installation neat inside modular enclosures.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eLED-based indication gives low power draw and easy visibility.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eFlame-retardant housing is useful in compact electrical assemblies.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eGood companion device for \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB boxes\u003c\/a\u003e, \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ecircuit breakers\u003c\/a\u003e, and \u003ca href=\"\/collections\/phase-sequence-relay\" style=\"color:#d42027;\"\u003ephase sequence relays\u003c\/a\u003e.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProduct type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3 phase DIN rail indicator light\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLocal listing voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e220V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDisplay colors\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRed, yellow, green\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMounting\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDIN rail, 35mm family reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated current family reference\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e0.5A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated frequency family reference\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e50\/60Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eConnection capacity family reference\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRigid conductor 1.5mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStandard context\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIEC 60947-5-1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHousing\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFlame-retardant housing stated on local sale page\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDimensions and exact module width\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNot clearly published on the live local page and have not been guessed\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis description uses only data published on the live local sale page plus limited official YCD9 family data where it clearly helps explain the product class. Exact dimensions, internal wiring layout, and lamp life in hours are not currently listed on the local page and have not been guessed.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range and Price\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eProduct\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePhase format\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eColor arrangement\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eVoltage\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrice\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYCD9-3 local sale listing\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3 phase\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGreen, yellow, red\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e220V local listing\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYCD9-1 nearby local listing\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSingle phase\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSingle-phase indication colors\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e220V local listing\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.300\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe key difference is simple. The single-phase light is for one line status. This three-phase DIN rail indicator light is for panels where you want separate visual confirmation of all three phases. If the panel builder or electrician needs faster fault spotting, the three-light format is the better buy.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications — Where to Use This Indicator Light\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product is most useful where people need immediate visual status without using a multimeter every time. In Lahore, panel builders often fit this kind of DIN rail indicator light in generator and commercial DB assemblies so staff can see phase presence quickly. In Karachi, it suits utility rooms, machine-control panels, and small industrial boards where the electrician wants simple visual confirmation of incoming or outgoing phase condition. In Faisalabad textile and workshop panels, a three-color phase display helps maintenance staff spot missing-phase problems faster before blaming the wrong device.\u003c\/p\u003e\n\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eApplication\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRecommended use\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy this product fits\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThree-phase distribution board\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse for visual phase presence indication\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eShows line status immediately without extra test gear\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGenerator backup panel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse to show phase availability before load transfer\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHelps staff see if all incoming phases are present\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAutomation or machine-control panel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as visible power-status indication\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSimple LED display is easier for operators and maintenance teams\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCommercial building services panel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse to show mains condition visually\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUseful where technical staff want a fast visual check\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSmall industrial DB or feeder board\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as line-status indicator near incoming supply\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLow-cost visual indication reduces confusion during troubleshooting\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Choose the Right Indicator Light\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eYour requirement\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eChoose this model?\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed visual status for all three phases\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThis product is made for that exact panel job\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed only one line or one circuit light\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMaybe not\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA single-phase indicator can be cheaper and simpler\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed actual voltage values\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNo\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse an \u003ca href=\"\/collections\/energy-meters\" style=\"color:#d42027;\"\u003eenergy meter\u003c\/a\u003e or panel meter instead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed automatic phase fault logic\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNo\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse a \u003ca href=\"\/collections\/phase-sequence-relay\" style=\"color:#d42027;\"\u003ephase sequence relay\u003c\/a\u003e for protection logic\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eIndicator Light vs Alternatives — Why CNC?\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePoint\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCNC 3 phase DIN rail indicator\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eLoose panel pilot lamps\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eDigital panel meter\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMain advantage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSimple DIN rail visual indication in one modular product\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMay be cheaper in some cases, but panel layout is less tidy\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eShows values, but costs more and does a different job\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFast phase-status visibility\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCustom panel work where the builder wants separate lamp hardware\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMeasurement and display rather than simple indication\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSelection logic\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eChoose when you want clean visual phase indication at low cost\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eChoose only if your panel format is already built around separate pilot lamps\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eChoose when you need numerical display, not just a lamp signal\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product does not protect the panel from overvoltage, undervoltage, short circuit, surge damage, earth leakage, or overload. It is an indication device only. It also does not measure energy consumption or replace a digital voltmeter. If you need fault protection, use the correct \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ecircuit breaker\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protector\u003c\/a\u003e, or \u003ca href=\"\/collections\/phase-sequence-relay\" style=\"color:#d42027;\"\u003ephase sequence relay\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n  \u003col style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount the indicator on a standard 35mm DIN rail inside the panel.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eConfirm the panel supply matches the local 220V indication version before wiring.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eUse clean phase identification so each lamp corresponds to the intended line.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eTighten conductors properly and keep wiring neat so status diagnosis remains simple.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eAfter energizing, verify each phase lamp operation before closing the board fully.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n  \u003cdiv style=\"margin-top:25px;padding:15px;background:#f9f9f9;border:1px solid #e0e0e0;border-radius:5px;\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin-bottom:10px\"\u003eComplete Your Electrical Setup\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSurge Protection Devices (SPD)\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🔌 \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003eVoltage Protectors\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📦 \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB Boxes\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🧰 \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003eCircuit Breakers\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🔄 \u003ca href=\"\/collections\/phase-sequence-relay\" style=\"color:#d42027;\"\u003ePhase Sequence Relays\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📟 \u003ca href=\"\/collections\/energy-meters\" style=\"color:#d42027;\"\u003eEnergy Meters\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🔴 \u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;\"\u003ePush Buttons\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🎛️ \u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;\"\u003eSelector Switches\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🚨 \u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;\"\u003eFire Extinguishers\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:0;\"\u003e📖 \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eGuide: Types of Circuit Breakers\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA DIN rail indicator light is usually part of a bigger panel story. It works best when paired with proper \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO \u0026amp; RCCB\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027;\"\u003eAC breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/timer-ah2n\" style=\"color:#d42027;\"\u003etimer switches\u003c\/a\u003e, \u003ca href=\"\/collections\/indicator-lights\" style=\"color:#d42027;\"\u003eindicator lights\u003c\/a\u003e, and \u003ca href=\"\/collections\/industrial-plug-socket\" style=\"color:#d42027;\"\u003eindustrial plugs \u0026amp; sockets\u003c\/a\u003e where relevant.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is a 3 phase DIN rail indicator light used for?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt is used to show visual status of three-phase supply lines inside a DB, generator panel, automation board, or machine-control enclosure.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the price of this indicator light in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eAt the time checked, the current local sale listing shows this product at Rs.400 in Pakistan.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this DIN rail indicator light measure voltage?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. It is a visual indication device, not a digital measuring meter. If you need voltage values, use a panel meter or \u003ca href=\"\/collections\/energy-meters\" style=\"color:#d42027;\"\u003eenergy meter\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this better than separate pilot lamps?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor many panel builders, yes. A DIN rail indicator light keeps the layout tidier and easier to install inside modular boards.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I use this in a generator changeover panel?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, that is one of the practical applications. It helps operators and technicians see incoming phase condition quickly before load transfer.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this product replace a phase sequence relay?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. It only indicates visually. A \u003ca href=\"\/collections\/phase-sequence-relay\" style=\"color:#d42027;\"\u003ephase sequence relay\u003c\/a\u003e is for monitoring and protection logic.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs the product mounted on a standard DIN rail?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. The official YCD9 family reference places it on a symmetrical 35mm DIN rail, which suits standard modular panel work.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat voltage does this local sale version use?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe current local sale page shows the version being sold as 220V input.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis DIN rail indicator light is a low-cost but useful panel accessory when you want quick three-phase visual status in Pakistan without moving to a meter or a more complex relay device. It suits DBs, generator panels, control boards, and workshop enclosures where electricians and maintenance staff want clear line indication at a glance. For price confirmation, stock status, or bulk panel requirements, contact CNC Electric Pakistan on WhatsApp 0326-1111376. Orders above Rs.10,000 qualify for free delivery.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"220V","offer_id":42404116332610,"sku":"YCD9-3","price":425.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Din_Rail_Single_Phase_Indication_Light.webp?v=1756119822"},{"product_id":"cnc-din-rail-single-phase-indication-light-ycd9-1","title":"Single Phase Din Rail Indicator Lights | Red, Yellow, Blue, Green","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eDin rail indicator light buyers in Pakistan choose the Single Phase Din Rail Indicator Lights YCD9-1 when they need panel pilot light performance for real installations rather than improvised solutions. Starting from Rs.300, this product suits everyday use cases such as AC lines, geysers, water pumps, fridges, washing machines, solar inverter setups, UPS-backed circuits, DB boxes, and backup power panels depending on the application.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eQuick Specs\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYCD9-1 Indicator Light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e220V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eSingle phase DIN rail LED indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eColors\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eRed, Green, Blue, Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eFunction\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eShows live power presence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDB boxes, control panels, changeover panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eIndicator only, no fault protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis DIN rail indicator light is a simple but important panel accessory that shows whether a circuit or phase is live. In Pakistan, many DB boxes and small panels are built without clear visual indication, which leads to confusion during troubleshooting, generator switching, maintenance, and daily operation. A pilot light solves that cheaply and neatly.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBecause it mounts on DIN rail, it looks professional inside a DB or changeover panel. Installers often use green for utility presence, red for generator, blue for inverter or control, and yellow for warning or alternate status. The actual color scheme depends on the panel builder, but the benefit is the same: faster understanding at a glance.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt is especially useful in homes with backup supply, shops with manual changeovers, and commercial panels where staff need to see the live state without touching wiring.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt is one of those low-cost items that make a panel look finished, readable, and much easier to use.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhere It Fits Best in Pakistan\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product is relevant for buyers across Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar because electrical conditions, backup power usage, and solar adoption make practical protection choices important. Whether the load is a 1 ton AC, 1.5 ton AC, 2 ton AC, geyser, water pump, fridge, washing machine, solar inverter, or UPS-backed line, the main question is not just price in Pakistan but whether the product is doing the right job in the system.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThat is why CNC Electric Pakistan positions this model as part of a full product family rather than a one-off item. You can combine it with matching \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027\"\u003eDB boxes\u003c\/a\u003e, \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003ebreakers\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003esurge protectors\u003c\/a\u003e, and \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027\"\u003echangeover switches\u003c\/a\u003e depending on the site.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSelection Guide\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eAppliance \/ Load \/ Use Case\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eRecommended Rating \/ Variant\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eHome DB incoming indication\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eRecommended\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eShows at a glance when incoming supply is live\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eChangeover panel source status\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eRecommended\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eUseful to show utility and generator presence with different colors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eShop \/ office small panel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eRecommended\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eImproves professional appearance and troubleshooting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eNeed fault protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNot enough by itself\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eUse MCB, RCBO, SPD, or VA devices as needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eNeed multi-phase indication\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eUse multiple units\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOne unit shows one status point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Install\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eInstallation should always be done by a licensed electrician or qualified solar installer. Clean wiring, correct torque, proper cable size, and testing matter as much as the product itself.\u003c\/p\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eTurn OFF supply before panel work.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eMount the indicator light on DIN rail.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eWire the indicator to the intended monitored point according to the panel design.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eUse the selected color scheme consistently for clear meaning.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eTest the light after energizing and label the panel if needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product does not protect against overload, short circuit, surge, earth leakage, or voltage fluctuation. It is only an indicator. You still need the proper protection devices such as \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003eMCBs\u003c\/a\u003e, \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027\"\u003eRCBO\/RCCB\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003eSPD\u003c\/a\u003e, and \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003eVA protectors\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eIndicator Light vs Meter vs Protector\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eOption 1\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eOption 2\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eOption 3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eShows power presence\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eSometimes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMeasures electrical values\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eSome models do\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eProvides protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eCost\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLow\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eHigher\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eHigher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eBest use\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eVisual status indication\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eMonitoring\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eProtection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCNC vs Schneider and Local Brands\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eCNC\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSchneider\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eLocal Brands\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eTypical price in Pakistan\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eRs.300\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eUsually much higher\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eVaries but often inconsistent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eStandards \/ documented product line\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDefined branded family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003ePremium branded family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften unclear in low-end market stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eChannel dependent\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften limited or unclear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eValue for Pakistani buyers\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eStrong price-to-performance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003ePremium but expensive\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eCheaper-looking but riskier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eAvailability of matching accessories\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes across multiple collections\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDepends on range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften mixed products from many sellers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCross-Category Recommendations\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIf you are buying this product, also consider \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027\"\u003eDB Boxes\u003c\/a\u003e Collection, \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027\"\u003e2P MCB\u003c\/a\u003e Rs.850, \u003ca href=\"\/products\/cnc-2p-voltage-protection-device-1-80a-yc7va\" style=\"color:#d42027\"\u003eVA Protector\u003c\/a\u003e Rs.1,700, \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027\"\u003eChangeover Switches\u003c\/a\u003e Collection.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBrowse \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003eAC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027\"\u003eDC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027\"\u003eAC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027\"\u003eDC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027\"\u003eMCCBs\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003eAC SPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027\"\u003eDC SPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-regulator\" style=\"color:#d42027\"\u003evoltage regulators \/ stabilizers\u003c\/a\u003e, \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027\"\u003eRCCB \/ RCBO\u003c\/a\u003e, \u003ca href=\"\/blogs\/news\/changeover-breaker-complete-guide-in-pakistan\" style=\"color:#d42027\"\u003echangeover guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003etypes of circuit breakers\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/mcb-size-chart-for-pakistan-pick-the-right-breaker-for-every-appliance\" style=\"color:#d42027\"\u003eMCB size chart for Pakistan\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/circuit-breaker-trip-curves-explained-b-c-and-d-curve-mcbs\" style=\"color:#d42027\"\u003etrip curves explained\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/spd-full-form-what-is-surge-protection-device-why-pakistan-needs-it\" style=\"color:#d42027\"\u003eSPD full form guide\u003c\/a\u003e for a complete project-level view before final selection.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products from CNC Electric\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027\"\u003eDB Boxes\u003c\/a\u003e — Collection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027\"\u003e2P MCB\u003c\/a\u003e — Rs.850\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-2p-voltage-protection-device-1-80a-yc7va\" style=\"color:#d42027\"\u003eVA Protector\u003c\/a\u003e — Rs.1,700\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027\"\u003eChangeover Switches\u003c\/a\u003e — Collection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the din rail indicator light price in Pakistan for this product?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product starts from Rs.300. Final selection depends on the chosen variant or system requirement. CNC Electric Pakistan also offers free delivery and a 5-year warranty.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWho should buy the Single Phase Din Rail Indicator Lights YCD9-1?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis model suits buyers in Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar who need a proper panel-mounted solution rather than a market workaround.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan a normal electrician install this?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA licensed electrician or qualified solar installer should install it, because correct wiring, sizing, and testing matter more than the product alone.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eHow do I choose the right rating or variant?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose the variant according to actual load current, system voltage, cable size, and application. The selection guide above gives a starting point, but final sizing should be verified on site.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this better than cheap local market alternatives?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor serious installations, buyers usually prefer a defined product line, clearer specifications, and a 5-year warranty instead of inconsistent no-name market stock.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this replace every other protection device in the panel?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. Each product has a specific role. A complete system may also need MCBs, RCBOs, SPDs, voltage protectors, changeovers, ATS units, fuses, or DB boxes depending on the job.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this available across Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, CNC Electric Pakistan sells across Pakistan with common demand from Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhy buy from CNC Electric Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBecause buyers want practical price in Pakistan, coordinated related products, free delivery, and after-sales support instead of mixing random parts from different sources.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I compare this with other CNC products before ordering?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. Use the related products and collection links in this description to compare alternative ratings, premium upgrades, and matching protection accessories before placing the order.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor full system planning, compare the linked collections and guides above. CNC Electric Pakistan offers free delivery, coordinated product ranges, and a 5-year warranty. WhatsApp us at 0326-1111376.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"Red","offer_id":42324147830850,"sku":"YCD9-1","price":325.0,"currency_code":"PKR","in_stock":true},{"title":"Green","offer_id":42324147863618,"sku":"YCD9-1","price":325.0,"currency_code":"PKR","in_stock":true},{"title":"Blue","offer_id":42324147896386,"sku":"YCD9-1","price":325.0,"currency_code":"PKR","in_stock":true},{"title":"Yellow","offer_id":42324147929154,"sku":"YCD9-1","price":325.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Din_Rail_Single_Phase_Indication_Light-2.webp?v=1756119882"},{"product_id":"panel-indicator-meters-ad16-22va-volt-and-ampre","title":"Panel Indicator Meter AD16-22VA | Volt \u0026 Ampere","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003ePanel volt amp meter price in Pakistan starts here at \u003cstrong\u003eRs.750\u003c\/strong\u003e. This CNC panel indicator meter is built for electricians, panel builders, and maintenance teams who want quick front-panel voltage and current visibility without fitting two separate meters. It suits control panels, generator boards, changeover panels, pump panels, and distribution boxes where a compact 22mm display makes more sense than a large door-mounted analog meter.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px;font-size:15px;line-height:1.6\"\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eDual display format for voltage and current indication.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e22mm panel-mount style for switchgear doors and control panels.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eAvailable in multiple front colors including red, yellow, blue, green, and white.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eVoltage range used in CNC catalog: AC 50V to 500V.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eCurrent display range used in CNC catalog: 0 to 100A.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eGood fit for generator panels, DBs, ATS panels, and motor-control boards.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eCompact front indication saves panel space compared with separate analog meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePanel indicator volt and amp meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e22mm panel cutout style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eVoltage display range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAC 50V to 500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCurrent display range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e0 to 100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDisplay colors\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWhite, green, red, yellow, blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTypical use\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePanel voltage and current indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWiring \/ CT details\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eContact us: 0326-1111376\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range and Prices\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eVariant\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eFront Color\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrice\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBest Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAD16-22VA\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRed \/ Yellow \/ Blue \/ Green \/ White\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.750\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGeneral control panel monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications in Pakistan\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis meter makes sense where the operator needs a quick glance at line condition. It works well in ATS panels, generator changeover boards, pump control panels, and commercial DBs. In Faisalabad textile support panels, a compact front-panel volt\/amp display is useful where maintenance staff want quick visual confirmation without adding separate analog meters. It also suits workshop boards, solar AC output panels, and machine-control enclosures where door space is limited.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eUse Case\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRecommended Setup\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eATS or changeover panel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDoor-mounted 22mm indicator meter\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eQuick source-side monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGenerator panel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eVolts + amps on the front fascia\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFast load confirmation during backup operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePump starter panel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePanel indicator with breaker and contactor\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSimple front-panel health check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCommercial DB or services panel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDoor indicator position\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eEasy live monitoring without a large meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Choose the Right Meter\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eYour Need\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eThis Product?\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBetter Alternative\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed compact panel volt + amp display\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed full kWh energy metering\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse an \u003ca href=\"\/collections\/energy-meters\" style=\"color:#d42027;\"\u003eenergy meter\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed only phase presence light\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMaybe not\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse \u003ca href=\"\/collections\/indicator-lights\" style=\"color:#d42027;\"\u003eindicator lights\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003ePanel Volt Amp Meter vs Alternatives\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePoint\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCNC AD16-22VA\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eAnalog Meter Pair\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eFull Digital Energy Meter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePrice\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.750\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually higher as two devices\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHigher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePanel space\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCompact 22mm style\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMore space needed\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLarger device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest job\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eQuick front-panel indication\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLegacy panels\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBilling and energy tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis meter does not protect the circuit. It does not trip on overload, short circuit, earth leakage, voltage surge, or over\/under voltage. It only shows values. Protection still comes from the right \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ebreaker\u003c\/a\u003e, \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO\/RCCB\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e, or \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protector\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n\u003col style=\"margin:10px 0;padding-left:20px;font-size:15px;line-height:1.6\"\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003ePrepare a 22mm panel hole in the door or fascia.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eWire the voltage sense input and the current side exactly as required for the panel design.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eCheck polarity and CT arrangement before energizing.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eTest the display under no-load and load conditions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003ePair this panel volt amp meter with \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB Boxes\u003c\/a\u003e, \u003ca href=\"\/collections\/indicator-lights\" style=\"color:#d42027;\"\u003eIndicator Lights\u003c\/a\u003e, \u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;\"\u003eSelector Switches\u003c\/a\u003e, \u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;\"\u003ePush Buttons\u003c\/a\u003e, \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003eCircuit Breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSurge Protection Devices\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003eVoltage Protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/ats\" style=\"color:#d42027;\"\u003eAutomatic Transfer Switches\u003c\/a\u003e, \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003eChangeover Breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003eMagnetic Contactors\u003c\/a\u003e, \u003ca href=\"\/collections\/energy-meters\" style=\"color:#d42027;\"\u003eEnergy Meters\u003c\/a\u003e, and \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of Circuit Breakers Guide\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the price of this panel volt amp meter in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eRs.750.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat does this meter show?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003ePanel voltage and current.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs it an energy meter?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. It is an indicator meter, not a kWh billing meter.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I use it in a generator panel?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes it trip the circuit?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. It only displays values.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this good for ATS and changeover panels?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, for front-panel indication.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat colors are available?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eRed, yellow, blue, green, and white.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eNeed full wiring detail?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eWhatsApp 0326-1111376.\u003c\/p\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eOrder this panel volt amp meter from CNC Electric Pakistan for compact front-panel monitoring in generator boards, ATS panels, DBs, and machine-control enclosures. WhatsApp \u003ca href=\"https:\/\/wa.me\/923261111376\" style=\"color:#d42027;\"\u003e0326-1111376\u003c\/a\u003e for wiring help, bulk pricing, and dispatch support.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"Red","offer_id":42445523451970,"sku":null,"price":900.0,"currency_code":"PKR","in_stock":true},{"title":"Yellow","offer_id":42445523484738,"sku":null,"price":900.0,"currency_code":"PKR","in_stock":true},{"title":"Blue","offer_id":42445523517506,"sku":null,"price":900.0,"currency_code":"PKR","in_stock":true},{"title":"Green","offer_id":42445523550274,"sku":null,"price":900.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Panel_Indicator_Meters_AD16-22VA_Voltand_Ampre-2.webp?v=1756118660"},{"product_id":"buy-cnc-voltmeter-selector-switch-precise-voltage-monitoring-online","title":"Voltmeter Selector Switch 20A | Monitoring","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eVoltmeter selector switch is the practical panel device used when one voltmeter has to read more than one voltage point inside the same board. On CNC Electric Pakistan, the live selector-switch range currently shows the voltmeter selector switch at \u003cstrong\u003eRs.1,300\u003c\/strong\u003e in a \u003cstrong\u003e20A\u003c\/strong\u003e version. That makes it a useful control-panel component for electricians, panel builders, generator-board fabricators, and industrial maintenance teams who want cleaner voltage monitoring without adding multiple separate panel meters.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis is not a breaker, and it is not a voltage protector. Its job is measurement selection. In a three-phase panel, you may want one meter to read different phase combinations or selected monitoring points. A proper selector switch gives that control in a tidy, repeatable way. For Pakistan work, that matters in factory panels, generator boards, workshop starter panels, school and hospital distribution rooms, and commercial building services boards where voltage needs to be checked quickly and correctly.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eFeature\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhat the buyer should know\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCurrent local variant\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e20A selector-switch version is visible on the local sale page.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCurrent local price\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.1,300 at the time checked.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDevice type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eManual rotary selector for choosing voltage measurement points in a panel.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFamily class\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLW28 universal changeover \/ selector-switch family.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTypical use\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eVoltmeter selection in control panels, DB boards, generator panels, and measurement circuits.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRelevant standard context\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIEC 60947-3 family context for main-circuit switching and direct control; IEC 60947-5 family context for master-control usage in the official LW28 notes.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eOne useful distinction: this product is for \u003cstrong\u003evoltage monitoring selection\u003c\/strong\u003e, while the nearby \u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;\"\u003eampere selector switch range\u003c\/a\u003e is for current measurement selection. If the panel meter is a voltmeter, you choose this style. If the panel meter is an ammeter, you choose the ampere selector. That sounds basic, but many mixed supplier listings blur these devices together and create confusion at ordering stage.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLocal sale product\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eVoltmeter Selector Switch 20A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLocal current rating shown\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e20A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFamily rated frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAC 50\/60Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFamily rated operational voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUp to 380V AC and up to 220V DC in the official LW28 universal family.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFunction marker in official selection notes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e“V” denotes voltmeter application; “A” denotes ammeter application.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTypical panel role\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMeasurement-point selection for a voltmeter in a control or distribution panel.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMounting \/ dimensions \/ station count for this exact local variant\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNot clearly published on the live local sale page and have not been guessed.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis description uses only data published on the live local sale page plus limited official LW28 family information where it clearly helps identify the switch class. Exact station count, internal contact arrangement, terminal numbering, panel cut-out dimensions, and drawing details for this exact local variant are not currently listed and have not been guessed.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range and Price Position\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eProduct in local range\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eUse case\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eVisible local price\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eVoltmeter Selector Switch 20A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eVoltage measurement-point selection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.1,300\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAmpere Selector Switch 20A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCurrent measurement-point selection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.1,300 on the same local range page\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003ePrice-wise, this is not a big-ticket item. Selection accuracy matters more than the amount on the invoice. Ordering the wrong meter selector wastes time because the panel cut-out may already be done, the labeling may already be printed, and the commissioning team may be waiting for the right part.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications in Pakistan\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eVoltmeter selector switches are common in panels where one analog or digital voltmeter is used to observe different incoming or outgoing voltage points. In Lahore commercial buildings, that often means generator and utility monitoring inside changeover or ATS-related boards. In Faisalabad factories, it can mean quick phase-voltage checking in production and utility rooms. In Karachi workshops, it is often used in starter panels, compressor boards, and distribution panels where a voltmeter needs to display selected phase combinations without fitting multiple separate meters.\u003c\/p\u003e\n\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eApplication\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy this switch fits\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhat it helps the technician do\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGenerator and mains monitoring panel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOne voltmeter can be routed to different reading points through a selector.\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCheck the selected voltage source quickly without installing multiple meters.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThree-phase distribution panel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUseful where one panel voltmeter must observe different voltage relationships.\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSimplify voltage monitoring inside a compact board.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMotor-control or utility starter panel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA selector avoids clutter when the panel needs only one voltmeter face.\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eObserve supply presence and selected voltage conditions during maintenance.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eEnergy-management panel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUseful when analog or basic voltage monitoring is still preferred.\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSelect the measurement point without replacing the whole metering setup.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eEducational or maintenance demo board\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA selector switch makes demonstration and testing simpler.\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eShow different readings on one instrument clearly and safely.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Choose the Right Selector Switch\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eQuestion\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eChoose this product if…\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eChoose something else if…\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAre you selecting voltage readings?\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes — this is the voltmeter selector switch.\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIf you are selecting current readings, choose the \u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;\"\u003eampere selector switch\u003c\/a\u003e version instead.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDo you need source transfer?\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNo — this part is for monitoring selection only.\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIf you need source transfer, use an \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003eAC changeover breaker\u003c\/a\u003e, \u003ca href=\"\/collections\/changeovers-switch-ep\" style=\"color:#d42027;\"\u003eEP changeover switch\u003c\/a\u003e, or \u003ca href=\"\/collections\/ats\" style=\"color:#d42027;\"\u003eATS\u003c\/a\u003e.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDo you need direct protection against voltage fluctuation?\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNo — this is not a protector.\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protector\u003c\/a\u003e or the \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;\"\u003evoltage protector finder\u003c\/a\u003e.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIs this for a meter point inside a control panel?\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes — that is exactly the normal job.\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIf you only need a fixed reading, a direct-wired voltmeter may be enough.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eVoltmeter Selector Switch vs Alternatives\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eOption\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBest when\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eMain limitation\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCNC voltmeter selector switch\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOne meter needs to read multiple voltage points inside a panel.\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIt monitors; it does not protect or transfer load.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAmpere selector switch\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOne ammeter needs to read different current circuits.\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWrong device for voltage selection.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDirect-wired dedicated voltmeter\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOnly one fixed voltage point needs to be shown.\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLess flexible when multiple readings are required.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCheap generic rotary cam switch\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLowest-budget panel work.\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSelection logic, build consistency, and labeling discipline are often weaker.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis selector switch does \u003cstrong\u003enot\u003c\/strong\u003e protect against overload, short circuit, under-voltage, over-voltage, surge, earth leakage, or backfeed. It is not a breaker, not a fuse, not a voltage protector, and not a transfer switch. Its purpose is to route a measurement circuit so the operator can choose what the voltmeter is reading.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIf the panel also needs real protection, add the correct \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ecircuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003esurge protection devices\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO\/RCCB protection\u003c\/a\u003e, or the right \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB breakers\u003c\/a\u003e depending on the board.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n  \u003col style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eConfirm first that the panel needs a \u003cstrong\u003evoltmeter selector\u003c\/strong\u003e, not an ammeter selector and not a changeover switch.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eFollow the panel designer’s measurement diagram so the selected positions match the required voltage points.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eLabel the front positions clearly. A selector switch without correct labeling confuses technicians and defeats the purpose.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount it rigidly in the panel front or meter section so switching feels positive and repeatable.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eBefore energizing, verify the meter reads the intended point in each position and that no wrong cross-reading occurs.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;\"\u003eSelector switches\u003c\/a\u003e for the full CNC selector range, including ammeter selection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/indicator-lights\" style=\"color:#d42027;\"\u003eIndicator lights\u003c\/a\u003e to show supply presence and selected phase status.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/energy-meters\" style=\"color:#d42027;\"\u003eEnergy meters\u003c\/a\u003e if the panel needs kWh or multifunction monitoring in addition to selector-based readings.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB boxes\u003c\/a\u003e for the enclosure side of the panel build.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003eChangeover breakers\u003c\/a\u003e if the board also needs manual source transfer.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/changeovers-switch-ep\" style=\"color:#d42027;\"\u003eEP changeover switches\u003c\/a\u003e when panel-source switching, not meter selection, is the real requirement.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/ats\" style=\"color:#d42027;\"\u003eAutomatic transfer switches\u003c\/a\u003e where changeover must happen automatically.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSurge protection devices\u003c\/a\u003e because measurement circuits inside panels still benefit from surge control.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003eVoltage protectors\u003c\/a\u003e if the panel is guarding appliances or sensitive loads against WAPDA fluctuations.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;\"\u003eVoltage protector finder tool\u003c\/a\u003e if you are also selecting protection hardware for the same job.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/news\/changeover-breaker-complete-guide-in-pakistan\" style=\"color:#d42027;\"\u003eChangeover breaker guide\u003c\/a\u003e if the customer is mixing up meter selection with source transfer.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of circuit breakers guide\u003c\/a\u003e for the protection side of the panel.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003eCircuit breakers\u003c\/a\u003e for upstream protection around the metering section.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003eMagnetic contactors\u003c\/a\u003e if the panel also controls motors or larger loads.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;\"\u003eFire extinguisher products\u003c\/a\u003e as the final panel-safety add-on.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is a voltmeter selector switch used for?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt is used to let one panel voltmeter read more than one voltage point. Instead of installing multiple separate voltmeters, the operator changes the selector position and checks the required reading.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the current price of this voltmeter selector switch in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eAt the time checked, CNC Electric Pakistan was showing this voltmeter selector switch at \u003cstrong\u003eRs.1,300\u003c\/strong\u003e.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this the same as an ammeter selector switch?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. The voltmeter selector switch is for voltage measurement selection. The ammeter selector switch is for current measurement selection. They belong to the same selector family but serve different meter circuits.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan this switch replace a changeover switch?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. A changeover switch transfers a load between sources. This selector switch only routes a measurement circuit for a voltmeter.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I use this in a generator panel?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, provided the panel design specifically needs a voltmeter selector for monitoring the required voltage points. It is common in generator, mains, and utility monitoring sections.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this selector switch protect against over-voltage?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. It does not provide voltage protection. If protection is needed, add a proper \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protector\u003c\/a\u003e or other suitable protection device.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this a DIN-rail device?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe live local sale page does not clearly publish the exact mounting format for this specific variant, so that should be confirmed at order stage if the panel cut-out or mounting method matters.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhy should I buy CNC instead of a generic rotary selector?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBecause a selector switch is a panel-logic component, not just a cheap knob. Wrong selection, weak labeling, poor feel, or bad application matching can create confusion during commissioning and maintenance. CNC’s selector-switch family is a known panel-control line rather than random generic stock.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis voltmeter selector switch is the right buy when a panel needs clean, simple voltage measurement selection instead of multiple separate meters. It suits control panels, generator boards, utility rooms, commercial distribution boards, and industrial maintenance panels across Pakistan where technicians need clear voltage monitoring without unnecessary clutter. For current stock, technical clarification, and order support, contact CNC Electric Pakistan on WhatsApp 0326-1111376. Orders above Rs.10,000 qualify for free delivery.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"Volt Selector Switch \/ 20A","offer_id":42324169785410,"sku":"v-a-selector-switch-lw28-20","price":1350.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Voltmeter_Selector_Switch_Precise_Voltage_Monitoring.webp?v=1755864597"},{"product_id":"3-phase-digital-voltage-meter-ycmv3-stable-efficient-monitoring","title":"3 Phase Digital Voltage Meter YCMV3 | Stable \u0026 Efficient Monitoring","description":"\u003cp\u003eLooking for a \u003cstrong\u003e3 phase digital voltmeter price in Pakistan\u003c\/strong\u003e for a distribution board, generator panel, solar AC side, or industrial control cabinet? This CNC Electric \u003cstrong\u003eYCMV3\u003c\/strong\u003e modular voltage meter is listed at \u003cstrong\u003eRs.2,100\u003c\/strong\u003e and is a practical panel instrument for electricians, builders, and maintenance teams who want a clear live voltage display instead of guessing line conditions.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase digital voltage meter for AC voltage measurement and display in electrical panels\u003c\/li\u003e\n\u003cli\u003eThree-phase 3 LED digital display (red and green)\u003c\/li\u003e\n\u003cli\u003eApplicable to circuits at 50\/60Hz — suitable for Pakistani power-system conditions\u003c\/li\u003e\n\u003cli\u003eWide AC 80V–500V measurement range for residential, commercial, and industrial panel use\u003c\/li\u003e\n\u003cli\u003eLow working current (≤20mA) — fits easily into DB metering sections\u003c\/li\u003e\n\u003cli\u003eAccuracy class 1\u003c\/li\u003e\n\u003cli\u003eFast measuring rate \u0026gt; 200ms\/update\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eYCMV3 three-phase digital voltage meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eThree-phase 3 LED digital display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigit colour\u003c\/td\u003e\n\u003ctd\u003eRed, Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003eAC 80V–500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking current\u003c\/td\u003e\n\u003ctd\u003e≤20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eClass 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring rate\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 200ms\/update\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard reference\u003c\/td\u003e\n\u003ctd\u003eIEC 60051-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrice\u003c\/td\u003e\n\u003ctd\u003eRs.2,100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eExact panel cutout, housing dimensions, IP rating, and wiring diagram were not clearly listed on the live page and have not been guessed.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eVariant \u0026amp; Price (Live on Shopify)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003ePhase type\u003c\/th\u003e\n\u003cth\u003eVoltage range\u003c\/th\u003e\n\u003cth\u003eTypical use\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYCMV3 Digital Voltage Meter\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003ctd\u003eAC 80V–500V\u003c\/td\u003e\n\u003ctd\u003ePanel voltage monitoring in DBs, machinery panels, generators, and commercial distribution boards\u003c\/td\u003e\n\u003ctd\u003eRs.2,100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eSingle variant — a dedicated voltage-display meter, not a multifunction energy meter.\u003c\/p\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase distribution boards where live line-voltage visibility helps spot imbalance\u003c\/li\u003e\n\u003cli\u003eGenerator and ATS panels in Lahore, Karachi, or Faisalabad where operators want to see actual phase voltage\u003c\/li\u003e\n\u003cli\u003eIndustrial control cabinets and machine panels where abnormal phase voltage creates equipment problems\u003c\/li\u003e\n\u003cli\u003eCommercial plazas and service panels needing clean front-panel voltage indication\u003c\/li\u003e\n\u003cli\u003eSolar AC side and building incoming panels where visible voltage helps maintenance and coordination\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Choose\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eNeed\u003c\/th\u003e\n\u003cth\u003ePick\u003c\/th\u003e\n\u003cth\u003eReason\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDedicated 3-phase voltage display\u003c\/td\u003e\n\u003ctd\u003eThis YCMV3 (Rs.2,100)\u003c\/td\u003e\n\u003ctd\u003eClean modular format for live voltage visibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent, power, PF, or kWh as well\u003c\/td\u003e\n\u003ctd\u003eMultifunction energy meter\u003c\/td\u003e\n\u003ctd\u003eVoltmeter alone won't give full metering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic disconnection on unsafe voltage\u003c\/td\u003e\n\u003ctd\u003eVoltage protector\u003c\/td\u003e\n\u003ctd\u003eA voltmeter only displays — doesn't protect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase-sequence or failure logic\u003c\/td\u003e\n\u003ctd\u003ePhase sequence relay\u003c\/td\u003e\n\u003ctd\u003eVoltmeter doesn't do sequence protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp\u003eIt is not a Voltage Protector and does not disconnect the load during unsafe voltage. It is not a Phase Sequence Relay. It is not a Surge Protection Device. It only displays voltage — it does not automatically correct poor supply quality.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the panel is a three-phase AC system within the meter's 80V–500V range.\u003c\/li\u003e\n\u003cli\u003eWire according to the local panel layout and the product's 3-phase terminal arrangement.\u003c\/li\u003e\n\u003cli\u003eMount in a clean, visible panel position so the operator can read voltage safely.\u003c\/li\u003e\n\u003cli\u003eAfter energising, confirm the display reacts properly across all phases under normal load.\u003c\/li\u003e\n\u003cli\u003eUse it as part of a wider panel system with phase protection, voltage protection, and breaker coordination.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/energy-meters\"\u003eEnergy Meters\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/phase-sequence-relay\"\u003ePhase Sequence Relays\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/voltage-protectors\"\u003eVoltage Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/indicator-lights\"\u003eIndicator Lights\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/circuit-breakers\"\u003eCircuit Breakers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/db-boxes\"\u003eDB Boxes\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePrice in Pakistan?\u003c\/strong\u003e\u003cbr\u003eRs.2,100 for the YCMV3 three-phase digital voltage meter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is it for?\u003c\/strong\u003e\u003cbr\u003eDisplaying the voltage of a three-phase AC system digitally so operators can monitor line conditions from the panel front.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage range?\u003c\/strong\u003e\u003cbr\u003eAC 80V–500V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e50Hz and 60Hz?\u003c\/strong\u003e\u003cbr\u003eYes, both.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it protect the panel from low or high voltage?\u003c\/strong\u003e\u003cbr\u003eNo — it is a measuring and display device only. Use a voltage protector for automatic disconnection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBetter than a multifunction energy meter?\u003c\/strong\u003e\u003cbr\u003eBetter only when you mainly need voltage visibility. For current, power, PF, or kWh, choose a multifunction meter.\u003c\/p\u003e\n\n\u003cp\u003eFor stock confirmation, panel matching, or pairing with phase-sequence relays and voltage protectors, WhatsApp \u003cstrong\u003e0326-1111376\u003c\/strong\u003e. Free delivery over Rs.10,000.\u003c\/p\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"Modular Voltage Meter Red Display","offer_id":42483810205762,"sku":null,"price":2100.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Digital_Voltage_Meter.webp?v=1759303338"},{"product_id":"cooling-fan","title":"AC Cooling Fan (Oil Type) | Reliable, Durable \u0026 Long-Lasting Cooling Solution","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eLooking for a panel cooling fan price in Pakistan for a DB box, automation cabinet, control panel, or machine enclosure? This CNC Electric AC cooling fan is built for installers and panel builders who need proper airflow inside electrical enclosures where heat buildup can shorten equipment life. In Pakistan, where panels often run in dusty workshops, hot utility rooms, and high-temperature industrial spaces, a good cooling fan helps keep breakers, relays, VFD drives, and control devices working more reliably. It is a practical add-on for anyone building or upgrading a professional panel instead of leaving heat management to chance.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eAC oil-type cooling fan designed for panel ventilation and industrial heat dissipation.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eOil lubrication system for smooth rotation, reduced friction, and longer running life.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eSquare-frame design supports practical mounting in compact electrical and mechanical cabinets.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eHigh airflow and pressure for thermal management in heated enclosures.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eLow-noise operation for control rooms, machine panels, and indoor service areas.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eDurable construction for vibration, wear, and industrial working conditions.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eUseful for \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB boxes\u003c\/a\u003e, automation cabinets, control panels, VFD drives, CNC machines, and industrial power systems.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eBetter than leaving a sealed panel to overheat without forced airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003ePublished Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eAC Cooling Fan (Oil Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eFrame\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eSquare frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eLubrication\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOil-lubricated bearing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eStandard industrial holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eNoise\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eLow-noise design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eVariant 1\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYC11025 (110×110×25 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eVariant 2\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYC15050-2 (150×150×51 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eVariant 3\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYC20060 (200×200×60 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePrice\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs. 1,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eUnpublished\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eCFM, current draw, RPM, IP rating, dB not listed and not guessed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range \/ Variant Table\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eSize\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYC11025\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e110×110×25 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eCompact DB boxes, smaller panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYC15050-2\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e150×150×51 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eLarger control panels, VFD panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYC20060\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e200×200×60 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eHeavy-duty industrial cabinets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eDB boxes and distribution panels where trapped heat affects breaker performance.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eAutomation cabinets and PLC panels in Lahore, Faisalabad, or Karachi.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eVFD drives and motor-control panels where heat increases nuisance shutdown risk.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eCNC machines and industrial power systems needing continuous airflow.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eControl panels with \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003econtactors\u003c\/a\u003e, relays, and timers that should not sit in stagnant hot air.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003ePakistan's hot and dusty conditions where passive ventilation alone is not enough.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSizing \/ Selection Guide\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong\u003eYC11025\u003c\/strong\u003e for compact panels and smaller DB boxes.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong\u003eYC15050-2\u003c\/strong\u003e for medium control cabinets and VFD panel builds.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong\u003eYC20060\u003c\/strong\u003e for larger industrial enclosures with higher heat load.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong\u003eCheck mounting layout\u003c\/strong\u003e so the fan has clean intake and exhaust path.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong\u003ePair with panel protection\u003c\/strong\u003e from \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027;\"\u003ebreakers\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e, and good enclosure planning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCooling Fan vs Alternatives — Why CNC?\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eFactor\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eCNC Electric\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eSchneider\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eABB\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eChint\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eClopal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBest fit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eDB boxes, VFD panels, machine enclosures\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePremium industrial packages\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eHigher-end project environments\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eMainstream alternative\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBudget-sensitive local jobs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eCooling\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOil-type long-life, multiple sizes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBrand-led selection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eProject-grade confidence\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBroad market relevance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eLower upfront cost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eNot a substitute for \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ebreakers\u003c\/a\u003e, \u003ca href=\"\/collections\/fuses\" style=\"color:#d42027;\"\u003efuses\u003c\/a\u003e, earthing, and proper panel design.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eNot an \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e for surge or transient protection.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eNot a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protector\u003c\/a\u003e for unstable mains.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eWill not fix a badly designed enclosure with no exhaust path.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eDoes not make a dusty or wet enclosure safe by itself. Filters and maintenance still matter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n\u003col style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eChoose fan size from real enclosure dimensions and internal heat load.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eMount using standard industrial points with correct airflow direction.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eKeep clear air path inside — don't blow into blocked corners.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eUse proper supply wiring through the correct \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027;\"\u003ebreaker\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eTest panel temperature under real running load.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003ePair with \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e, enclosure planning, and the \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027;\"\u003eFire Extinguisher Guide\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCross-Category Links\u003c\/h2\u003e\n\u003cdiv style=\"margin-top:25px;padding:15px;background:#f9f9f9;border:1px solid #e0e0e0;border-radius:5px;\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin-bottom:10px;\"\u003eComplete Your Panel Build\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB Boxes\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003eCircuit Breakers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSurge Protection Devices\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003eVoltage Protectors\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003eMagnetic Contactors\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/timer-ah2n\" style=\"color:#d42027;\"\u003eTimer Switches\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📖 \u003ca href=\"\/blogs\/guides\/solar-db-box-guide-everything-pakistan-installers-need-to-know\" style=\"color:#d42027;\"\u003eSolar DB Box Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:0;\"\u003e📖 \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027;\"\u003eFire Extinguisher Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px\"\u003e⚡ \u003ca href=\"\/collections\/cooling-fan\" style=\"color:#d42027\"\u003eCooling Fans\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is a panel cooling fan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA ventilation fan used inside electrical enclosures to move air and reduce heat buildup around breakers, drives, relays, and control electronics.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhere can this AC cooling fan be used?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eDB boxes, automation cabinets, control panels, VFD drives, CNC machines, and industrial power systems.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat does oil-type cooling fan mean?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eOil-lubricated bearing for smoother operation, lower friction, and longer working life.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat sizes are available?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYC11025 (110mm), YC15050-2 (150mm), and YC20060 (200mm).\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the panel cooling fan price in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eRs. 1,200 on the current collection listing.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhy not leave the panel unventilated?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eTrapped heat shortens component life, increases nuisance tripping, and stresses electronics.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this better than a generic local fan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes — panel-focused with industrial mounting, oil-type bearing, and professional fit.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan this cool a VFD panel or CNC machine cabinet?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, those are published use cases where consistent panel airflow is needed.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eHow do I choose the right size?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFrom enclosure size, number of heat-producing devices, and available air path inside the cabinet.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eShould I add other protection?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003eBreaker protection\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e, earthing, and safe enclosure practice are still needed.\u003c\/p\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor panel work where heat is a real concern, this CNC Electric AC cooling fan is a strong practical option for DB boxes, automation cabinets, VFD panels, and machine enclosures in Pakistan. For stock confirmation, size guidance, or help pairing with breakers and SPD, contact CNC Electric Pakistan on WhatsApp before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"YC11025 ( 110×110×25mm )  6 Inch","offer_id":42483816988738,"sku":null,"price":1800.0,"currency_code":"PKR","in_stock":true},{"title":"YC15050-2 ( 150×150×51mm )  8 Inch","offer_id":42483817021506,"sku":null,"price":3500.0,"currency_code":"PKR","in_stock":true},{"title":"YC20060 ( 200×200×60mm )  10 Inch","offer_id":42483817054274,"sku":null,"price":6500.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Cooling_Fan_Oil_Type.webp?v=1759303665"},{"product_id":"low-voltage-shunt-bsmj0-44-15-3-bsmj0-44-25-3-bsmj0-44-50-3-power-capacitor-reliable-reactive-power-compensation","title":"BSMJ 440V Low Voltage Shunt Power Capacitor 15 \/ 25 \/ 50 kvar | 3-Phase Self-Healing PFC","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\n\u003cdiv style=\"background:#fef3c7;border-left:4px solid #d97706;padding:14px 18px;margin:0 0 18px;border-radius:6px;\"\u003e\n\u003cp style=\"margin:0 0 6px;font-weight:600;color:#78350f;\"\u003eSpec correction (June 2026)\u003c\/p\u003e\n\u003cp style=\"margin:0;color:#78350f;font-size:14px;\"\u003eEarlier product listings showed this BSMJ as \"220V\" — that was a transcription error. The BSMJ0.44 model code corresponds to a \u003cstrong\u003e440V line-to-line\u003c\/strong\u003e 3-phase shunt capacitor. The unit IS suitable for the Pakistani LT industrial 400V system. Pakistani buyers should size cabling and switching for the 440V \/ 3-phase current — see calculation below.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:18px;font-weight:700;margin:14px 0 8px;color:#111\"\u003eBSMJ Low Voltage Shunt Capacitor — Pakistani Power Factor Correction\u003c\/h2\u003e\n\u003cp\u003eThe BSMJ family is a self-healing metallized polypropylene film capacitor designed for low-voltage power-factor correction (PFC) in 3-phase industrial panels. Pakistani factory and commercial installations use BSMJ inside a capacitor bank, switched by a JKW power-factor controller via dedicated capacitor-duty contactors (CJ19 family) — adding kVAr in steps to lift the power factor from ~0.7 (uncorrected) to 0.95+ (target for K-Electric \/ IESCO penalty avoidance).\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:18px;font-weight:700;margin:14px 0 8px;color:#111\"\u003eThree sizes available on cncelectric.pk\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;margin:8px 0\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f3f4f6\"\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d1d5db\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d1d5db\"\u003eVoltage\u003c\/th\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d1d5db\"\u003eCapacity\u003c\/th\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d1d5db\"\u003ePhase\u003c\/th\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d1d5db\"\u003eLine current\u003c\/th\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d1d5db\"\u003ePKR\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e\u003cstrong\u003eBSMJ0.44-15-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e440 V\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e15 kvar\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e3-phase\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e19.7 A\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e6,700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e\u003cstrong\u003eBSMJ0.44-25-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e440 V\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e25 kvar\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e3-phase\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e32.8 A\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e9,900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e\u003cstrong\u003eBSMJ0.44-50-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e440 V\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e50 kvar\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e3-phase\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e65.6 A\u003c\/td\u003e\n\u003ctd style=\"padding:7px;border:1px solid #e5e7eb\"\u003e18,900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size:13px;color:#6b7280\"\u003eLine current at 400V LL = Q \/ (√3 × V) — installers sizing cabling at 400V Pakistani LT use these current values.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:18px;font-weight:700;margin:14px 0 8px;color:#111\"\u003eStandards\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60831-1 \/ -2\u003c\/strong\u003e — Self-healing power capacitors, low-voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60931-1 \/ -2\u003c\/strong\u003e — Non-self-healing power capacitors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGB\/T 12747-2017\u003c\/strong\u003e — Chinese national standard for self-healing shunt capacitors (manufacturer compliance)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:18px;font-weight:700;margin:14px 0 8px;color:#111\"\u003eWhere to use this BSMJ in Pakistan\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory main panel\u003c\/strong\u003e — fixed bank of 15\/25\/50 kvar capacitors switched by JKW5C controller; lifts PF from 0.75 to 0.95+ avoiding NEPRA capacity penalties\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial tower main DB\u003c\/strong\u003e — 5-7 step bank with mixed-size capacitors (e.g. 1×50 + 2×25 + 3×15) for fine PF control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTube-well motor panel\u003c\/strong\u003e — fixed 15 kvar bank in parallel with the motor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar prosumer site\u003c\/strong\u003e — small fixed bank to correct inductive load PF before metering point\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:18px;font-weight:700;margin:14px 0 8px;color:#111\"\u003eRecommended companions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\"\u003e\u003cstrong\u003eCJ19 \/ CJX2 capacitor-duty contactor\u003c\/strong\u003e\u003c\/a\u003e sized 1.5× line current\u003c\/li\u003e\n\u003cli\u003eInrush limiting reactor (de-tuned 7% or 14% if harmonics present)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/ac-fuse\"\u003e\u003cstrong\u003eHRC AC fuse\u003c\/strong\u003e\u003c\/a\u003e sized at 1.6-1.8× line current per IEC 60269\u003c\/li\u003e\n\u003cli\u003eJKW5C automatic power-factor controller (8\/12 step)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/ac-spd\"\u003e\u003cstrong\u003eType 2 AC SPD\u003c\/strong\u003e\u003c\/a\u003e upstream — capacitor banks are common surge entry points\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:18px;font-weight:700;margin:14px 0 8px;color:#111\"\u003eLearn more\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/guides\/power-factor-correction-capacitor-pakistan-2026-bsmj-buyer-guide\"\u003eRead the complete BSMJ \/ Power Factor Correction buyer guide for Pakistan 2026\u003c\/a\u003e — sizing math, harmonic considerations, NEPRA penalty thresholds, and panel design examples.\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"440V 15 kvar","offer_id":42487686234178,"sku":null,"price":6700.0,"currency_code":"PKR","in_stock":true},{"title":"440V 25 kvar","offer_id":42487686266946,"sku":null,"price":9900.0,"currency_code":"PKR","in_stock":true},{"title":"440V 50 kvar","offer_id":42487686299714,"sku":null,"price":18900.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Low_Voltage_Shunt_BSMJ0.44-15-3.webp?v=1770883647"},{"product_id":"cnc-electric-push-button-switch-red-green-lay5-ea45","title":"Push Button Switch Red \u0026 Green | Industrial","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003ePush button switch red and green set from CNC Electric Pakistan is the simple control part used in thousands of panels every day. Price starts at Rs.230 per button. This 22mm panel-mount push button is built for start and stop duty in motor panels, machine controls, pump boards, conveyor stations, and workshop automation where the operator needs a clear manual command point.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e22mm panel-mount push button for standard control panel cutouts.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eAvailable in green and red, both priced at Rs.230.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eUsed for start-stop control, machine commands, and panel signaling.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eFast spring-return push action for routine operator use.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eFits electrical panels, automation stations, motor starters, and machine boxes.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eGood match with \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003emagnetic contactors\u003c\/a\u003e, \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003ethermal relays\u003c\/a\u003e, and \u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;\"\u003eselector switches\u003c\/a\u003e.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProduct type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIndustrial push button switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLAY5 family\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMounting size\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e22mm panel mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eColours available\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGreen, Red\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAction\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMomentary push button operation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTypical use\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStart \/ stop commands, machine control, panel operation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRelevant standard class\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIEC 60947-5-1 control-circuit device context\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePanel cutout, contact block and wiring detail\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eContact us: 0326-1111376\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range and Prices\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eVariant\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eColour\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eUse\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrice\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGreen\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGreen\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStart, run, enable command\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.230\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRed\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRed\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStop, trip reset, OFF command\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.230\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis push button switch is used anywhere an operator needs a simple manual control point. Typical jobs include motor starter panels, small pump boards, conveyor stations, machine control boxes, door and gate control panels, and workshop automation. In Faisalabad textile panels, these start-stop buttons are common on loom auxiliaries and small control stations where operators need a clear green start and red stop layout.\u003c\/p\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eUse case\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRecommended button\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMotor start station\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGreen + Red pair\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eClear start and stop layout for operators\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePump control panel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGreen start\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSimple run command from panel face\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMachine stop function\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRed stop button\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFast manual stop point on the control door\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eConveyor or utility panel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGreen + Red pair\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSimple operator control without a PLC screen\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Choose\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eYour need\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eChoose\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBetter alternative\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRoutine start command\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGreen push button\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSelector switch for maintained position control\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRoutine stop command\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRed push button\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eEmergency mushroom stop for safety shutdown\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eEmergency stop duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNo\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e\u003ca href=\"\/products\/cnc-electric-emergency-push-button-switch-red-lay5-es545-r\" style=\"color:#d42027;\"\u003eEmergency stop push button\u003c\/a\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003ePush Button Switch vs Alternatives\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePoint\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCNC LAY5 Red\/Green\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eEmergency mushroom stop\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eSelector switch\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLocal price\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.230\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.320\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.1,300\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRoutine start \/ stop command\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eEmergency shutdown\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMaintained mode selection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAction style\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMomentary push\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLocking or emergency stop\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRotary maintained position\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis push button switch does not protect against overload, short circuit, surge damage, or earth leakage. It is an operator command device, not a protection device. For motor protection, you still need the correct \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003econtactor\u003c\/a\u003e, \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003ethermal relay\u003c\/a\u003e, \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ebreaker\u003c\/a\u003e, and where needed, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n  \u003col style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eCut a standard 22mm panel hole.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount the button firmly on the panel door or box.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eWire the contact block to the control circuit.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eTest start \/ stop logic before energizing the load.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n  \u003cdiv style=\"margin-top:25px;padding:15px;background:#f9f9f9;border:1px solid #e0e0e0;border-radius:5px;\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin-bottom:10px;\"\u003eComplete Your Electrical Setup\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;\"\u003ePush Buttons\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🔄 \u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;\"\u003eSelector Switches\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🧲 \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003eMagnetic Contactors\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🌡️ \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003eThermal Relays\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003eCircuit Breakers\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🛡️ \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSurge Protection Devices (SPD)\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📦 \u003ca href=\"\/collections\/industrial-products\" style=\"color:#d42027;\"\u003eIndustrial Products\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📖 \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of Circuit Breakers Guide\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📖 \u003ca href=\"\/blogs\/guides\/rccb-breaker-guide-pakistan-earth-leakage-protection\" style=\"color:#d42027;\"\u003eRCBO vs RCCB Guide\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:0;\"\u003e🔥 \u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;\"\u003eFire Extinguishers\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis push button switch works best with the right control hardware around it. Pair it with \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003econtactors\u003c\/a\u003e, \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003ethermal overload relays\u003c\/a\u003e, \u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;\"\u003eselector switches\u003c\/a\u003e, \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ecircuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB boxes\u003c\/a\u003e, and \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protectors\u003c\/a\u003e. For automation or workshop panels, see our \u003ca href=\"\/collections\/industrial-products\" style=\"color:#d42027;\"\u003eindustrial products\u003c\/a\u003e range and the \u003ca href=\"\/blogs\/guides\/rccb-breaker-guide-pakistan-earth-leakage-protection\" style=\"color:#d42027;\"\u003eSafety Breaker Guide\u003c\/a\u003e for protection planning.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the price of this push button switch in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eRs.230 per button.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs it available in red and green?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. Both colours are available.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this an emergency stop button?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. Use the mushroom emergency stop button instead.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I use it for motor start and stop?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, in a proper control circuit.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs it panel mount?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, 22mm panel mount.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan it replace a selector switch?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. Selector switches hold position; push buttons do not.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes it come with full wiring details?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eContact us on WhatsApp for wiring help.\u003c\/p\u003e\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhere can I buy it in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eOrder from CNC Electric Pakistan.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBuy this push button switch from CNC Electric Pakistan for Rs.230 and get fast support on WhatsApp \u003ca href=\"https:\/\/wa.me\/923261111376\" style=\"color:#d42027;\"\u003e0326-1111376\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"Green","offer_id":42896141418562,"sku":null,"price":275.0,"currency_code":"PKR","in_stock":false},{"title":"Red","offer_id":42896141451330,"sku":null,"price":275.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/CNC_Electric_Push_Button_Switch_Red_Green_LAY5-EA45.webp?v=1768553757"},{"product_id":"cnc-electric-emergency-push-button-switch-red-lay5-es545-r","title":"Emergency Stop Push Button | Red Mushroom","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.7;color:#222;max-width:820px\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:22px 0 8px;color:#1a1a1a\"\u003eLAY5-ES545 Emergency Stop Push Button -- Red Mushroom Head\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;font-size:15px;line-height:1.7\"\u003eA standard 22mm emergency stop push button with a red mushroom-head actuator and twist-to-release mechanism. This is the same style of E-stop used in factories, CNC machines, and industrial control panels worldwide. One NC (normally closed) contact block is included.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 12px;font-size:15px;line-height:1.7\"\u003eWhen pressed, the mushroom head locks down and opens the NC contact, cutting power to the machine or process. To reset, twist the red head clockwise until it pops back up. Simple, reliable, and compliant with IEC 60947-5-5.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:22px 0 8px;color:#1a1a1a\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 18px;font-size:14px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003eLAY5-ES545\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003eEmergency Stop, Twist Release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eHead\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003e40mm Red Mushroom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eMounting Hole\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003e22mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eContacts\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003e1 NC (normally closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eRated Voltage\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003eAC\/DC up to 440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eRated Current\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eStandard\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003eIEC 60947-5-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eColor\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003eRed head, yellow base (standard safety colors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:22px 0 8px;color:#1a1a1a\"\u003eTypical Uses\u003c\/h2\u003e\n\u003cul style=\"margin:8px 0 14px 18px;padding:0\"\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eMachine tool emergency stop (lathes, presses, CNC routers)\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eConveyor belt kill switch\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eElevator and lift control panels\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eGenerator control panels and ATS enclosures\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eAny control panel requiring a safety shutdown button\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:22px 0 8px;color:#1a1a1a\"\u003eWiring\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;font-size:15px;line-height:1.7\"\u003eWire the NC contact in series with the machine contactor coil or safety relay input. When the button is pressed, the NC contact opens, de-energizing the contactor and stopping the machine. This fail-safe design means a broken wire also stops the machine -- the correct behavior for emergency circuits.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"Default Title","offer_id":42896728784962,"sku":null,"price":350.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Emergency_Push_Button_Switch_Red_LAY5-ES545-R.webp?v=1768555685"},{"product_id":"roller-plunger-limit-switch-d4mc-5020-mechanical-position-detection-switch","title":"Limit Switch Roller Plunger | Industrial","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eD4MC-5020 roller plunger limit switch is the right choice when the moving part comes straight into the switch and you want a clear direct-hit signal instead of a wide lever sweep. The live Pakistan listing shows this model at Rs.600 and 10A. That makes it a very practical control-duty switch for CNC homing, linear slides, stopper plates, carriage end-travel points and straight-line machine motion where repeatable contact matters more than side approach tolerance.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis is not the same job as a roller lever. A lever model is better when the machine part approaches from the side, swings in an arc or needs some mechanical forgiveness. D4MC-5020 is for the opposite situation. It suits direct-line motion. If a plate, carriage or actuator comes in straight and you want the switch to prove that exact point cleanly, a roller plunger usually makes more sense than a broader lever head.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features and Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eFeature\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eDetails\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eD4MC-5020\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eActuator type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRoller plunger\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLive listing current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e10A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest fit\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStraight-line actuation, direct-hit travel point, CNC homing, linear slides, stopper-plate contact\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTypical control role\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eEnd-travel signal, proof-of-position, home reference, interlock point\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRelevant standard context\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIEC 60947-5-1 control-circuit device class\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe value in this model is not only its low price. It is motion geometry. If the striker or moving plate hits one specific point and repeats the same approach every cycle, a plunger style often gives a cleaner mechanical signal than a lever. That is why this model makes sense on machine carriages, jigs, small CNC axes, sliding stops and guided mechanisms where the approach is deliberate and straight.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProduct type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIndustrial micro limit switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHead style\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRoller plunger head for direct mechanical contact\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLoad data seen on official D4MC reference snippet\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAC 250V 10A, AC 380V 10A, DC 125V 5A, DC 250V 5A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMechanical life seen on official D4MC reference snippet\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e15 million operations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eElectrical life seen on official D4MC reference snippet\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e500,000 operations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLocal sales facts\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePakistan listing shows 10A and Rs.600 for this model\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFull body dimensions, pre-travel and operating force\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNot clearly published on the live local page and have not been guessed\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis description uses only data published on the live product page plus a limited amount of official D4MC family data that helps explain the switch class. Full drawing dimensions, exact plunger travel figures, terminal numbering and operating-force values are not currently listed on the local product page and have not been guessed.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range and Models\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eModel\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eActuator\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eListed current\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrimary job\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrice\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eD4MC-5020\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRoller plunger\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e10A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDirect-hit position sensing for straight-line motion\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.600\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eIf your machine motion is...\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eChoose this model?\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eReason\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStraight-line carriage or slide travel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThis is exactly where a plunger head is strongest\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCam comes from the side or sweeps through an arc\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually no\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA roller lever generally handles that motion better\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed one exact stop point\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDirect contact helps repeatable straight-point confirmation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRough high-impact conveyor or mill site\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse caution\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA heavier industrial switch body may survive better there\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications in Pakistan\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eD4MC-5020 fits machines where the motion is guided and comes in straight. In Sialkot, that can mean light engineering fixtures, stopper plates and small carriage travel checks. In Lahore, it suits machine-building work where a direct home point is needed on a slide, pusher or linear bracket. In Karachi, compact workshop machines and panel-integrated control systems often use this kind of plunger switch where a moving part hits one point directly and the signal needs to repeat every cycle.\u003c\/p\u003e\n\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eApplication\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRecommended use\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy this model fits\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCNC homing point\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as a home or reference-stop confirmation switch\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStraight approach and defined contact point suit a plunger head\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLinear slide or carriage end travel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse for end-of-stroke signal\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThe moving part comes in straight, not at an angle\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStopper plate or guided tab contact\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as proof-of-stop signal\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDirect point contact is cleaner than a side lever here\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBench machine or compact fixture\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as repeat-position signal\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGood for simple guided motion with a repeatable hit point\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePanel-linked mechanical interlock point\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as direct contact feedback\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBetter when the trigger path is straight and controlled\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCNC vs Competitors\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePoint\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCNC D4MC-5020\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCheap market copy\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRoller lever style\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMain advantage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDirect straight-line position sensing\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLower price sometimes, but consistency is uncertain\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBetter only when the motion comes from the side\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHoming, slides, stopper plates, guided direct-hit motion\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGeneral replacement where design logic is often ignored\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePackaging arms, gate links and broad mechanical sweep\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSelection risk\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLow if your motion is straight and repeatable\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHigher because build consistency can vary\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWrong choice if the machine hits one exact point straight on\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis limit switch does not replace a breaker, overload relay, surge protector or safety-rated interlock. It does not stop voltage spikes, motor overheating or short circuits. It also does not correct poor alignment. If the machine part hits the plunger at the wrong angle, with too much force or from an uncontrolled path, the switch cannot compensate for bad mechanical design.\u003c\/p\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIf the panel also needs proper switching and protection, pair this control device with the right \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003ecircuit breaker\u003c\/a\u003e, a suitable \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003esurge protection device\u003c\/a\u003e, the correct \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003emagnetic contactor\u003c\/a\u003e, and where motors are involved, a matching \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003ethermal relay\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n  \u003col style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount the switch on a rigid bracket so the plunger meets the striker in a straight controlled path.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eUse a stopper plate, tab or guided contact point that hits the plunger squarely instead of from the side.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eAvoid excessive impact and over-travel. The job is to confirm a point, not absorb a hard mechanical blow.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eWire it only into the intended control circuit after confirming the required contact logic for the machine or controller.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eRun dry mechanical cycles first and check that the switching point repeats cleanly before operating the machine under power.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;font-weight:700\"\u003ePush buttons\u003c\/a\u003e for operator control on the same machine panel.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;font-weight:700\"\u003eSelector switches\u003c\/a\u003e for manual mode or position selection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eMagnetic contactors\u003c\/a\u003e when the limit signal needs to drive a motor-control circuit.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eThermal relays\u003c\/a\u003e to protect motors used in the same machine.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003eCircuit breakers\u003c\/a\u003e for feeder and control-panel protection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/industrial-products\" style=\"color:#d42027;font-weight:700\"\u003eIndustrial products\u003c\/a\u003e for the rest of the machine hardware.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003eSPD\u003c\/a\u003e if the machine panel sits near motors, drives or a DB where surge stress can damage control components.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;font-weight:700\"\u003eFire extinguisher products\u003c\/a\u003e as the final panel-safety add-on.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003eTypes of circuit breakers\u003c\/a\u003e if you are planning the full panel.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/rccb-breaker-guide-pakistan-earth-leakage-protection\" style=\"color:#d42027\"\u003eSafety breaker guide\u003c\/a\u003e for wider protection planning.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e1. When should I choose a roller plunger instead of a roller lever?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose a roller plunger when the moving part approaches in a straight line and hits one specific point directly. Use a lever when the motion comes from the side or in an arc.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e2. Is D4MC-5020 good for CNC homing?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, that is one of the strongest use cases for this style, provided the approach is guided and repeatable.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e3. Can I use this switch directly in the power line of a motor?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. This is a control-duty switching device, not the main power switch for a motor load.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e4. What is the listed price of D4MC-5020 in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eAt the time checked, the live Pakistan page listed this model at Rs.600.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e5. Why is alignment more important on a plunger model?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBecause the moving part should hit the plunger squarely. A bad angle can side-load the head and make the switching point less reliable.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e6. Is this model suitable for stopper-plate contact on a slide?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. That is a very natural job for a direct-contact plunger switch.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e7. Can this switch be used as PLC position feedback?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. It is commonly suited to PLC, relay-logic and contactor-control position feedback when wired correctly.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e8. What usually causes early failure in a plunger-style limit switch?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003ePoor alignment, too much impact, side loading, loose mounting and choosing a light-duty body for a rough site are common reasons.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eD4MC-5020 is the right low-cost choice when the machine needs a direct push-type travel signal rather than a broader lever sweep. It suits homing points, linear slides, stopper plates and guided machine travel where the contact path is straight and controlled. For stock status, price confirmation and selection help, contact CNC Electric Pakistan on WhatsApp 0326-1111376. Orders above Rs.10,000 qualify for free delivery, and matching control hardware can be selected from the same store.\u003c\/p\u003e\n\u003c\/div\u003e\n---","brand":"CNC Electric Pakistan","offers":[{"title":"10A","offer_id":43009677721666,"sku":null,"price":600.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Roller_Plunger_Limit_Switch_D4MC-5020.webp?v=1771488485"},{"product_id":"limit-switch-d4mc-2000-roller-lever-industrial-micro-limit-switch-for-automation-control-panels","title":"Limit Switch D4MC-2000 Roller Lever | IP65 Industrial","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eLimit switch roller lever D4MC-2000 is the right low-cost choice when a moving part approaches from the side and you need a little mechanical reach instead of a straight push. On the live product page this model is listed at 10A and Rs.600. For small packaging machines, light conveyors, gate mechanisms and simple automation panels, that makes it a practical control-circuit sensor rather than an expensive specialty switch.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features and Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eFeature\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eDetails\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eD4MC-2000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eActuator style\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRoller lever\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCurrent shown on listing\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e10A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMain job\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMechanical position detection and control-signal switching\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest fit\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSide approach, cam approach, arm sweep, light end-travel sensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRelevant standard\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIEC 60947-5-1 control-circuit device context\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe real selection point is not just price. It is motion geometry. A roller lever is useful when the moving part does not come perfectly straight into the switch. If a bracket, trolley, cam plate or gate arm arrives from the side or at a slight angle, the lever gives you more forgiveness than a plunger style. That is why this model belongs in light automation and motion-control duty, not in every machine by default.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProduct type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIndustrial micro limit switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eActuator\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRoller lever head\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eListing current rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e10A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMounting style\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMachine body or bracket mounting\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse circuit\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eControl circuit, interlock, end-travel, position feedback\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOutdoor sealing claim\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThe live Pakistan page uses IP65 wording for this listing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBody material and full dimensions\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNot currently listed on the live product page and have not been guessed\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eElectrical life \/ mechanical life\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNot currently listed on the live product page and have not been guessed\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis description uses only data published on the live product page. Full dimension drawings, terminal configuration details, precise operating force and differential-travel values are not currently listed and have not been guessed.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range and Models\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eModel\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eActuator\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eListing current\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrice\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eD4MC-2000\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRoller lever\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e10A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSide approach sensing, moving arms, cams, light machine travel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.600\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis page is for one specific lever style. If your machine requires straight-on contact, a roller plunger works better. If space is very tight, a miniature model may fit better. If the site is dirty, rough and heavy-duty, you step up to a stronger industrial body instead of forcing this light-duty switch into a harsh job.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications in Pakistan\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eD4MC-2000 makes sense where the moving part sweeps into the switch instead of hitting it dead centre. That is common on small packaging rigs, sliding mechanisms, auto-gate linkages, light conveyors and machine guards. In Sialkot workshops, a lever type like this suits low-cost fixture movement and small production machines where a direct plunger is too unforgiving. In Lahore gate and panel work, installers often need a switch that can tolerate a little approach variation without losing the signal point completely.\u003c\/p\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eApplication\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRecommended use\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy this model fits\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePackaging machine pusher arm\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as end-travel or product-count position signal\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLever can be touched by a moving arm or cam with some approach tolerance\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSliding gate linkage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as open or close position interlock\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSide-approach motion is better matched to a lever than a plunger\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLight conveyor or tray stop\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse for travel indication or item presence at stop point\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMoving bracket or tray can sweep into the roller without perfect centring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMachine guard door or flap\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse for simple control interlock signal\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA small moving tab can operate the lever without needing a deep straight push\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSmall automation fixture in Karachi or Sialkot\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as cycle-complete or home-return signal\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBetter when the mechanical part swings past the switch instead of stabbing straight into it\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSizing and Selection Guide\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eYour motion condition\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eChoose this style?\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eReason\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMoving part comes from the side or in an arc\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThis is exactly where a lever head helps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMoving part hits straight into one point\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually no\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA roller plunger gives a cleaner direct-hit response\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eVery tight mounting space\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMaybe not\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA miniature body can fit better than a standard lever type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDirty, shock-heavy, abusive site\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse caution\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA heavier industrial body is safer for cement, steel and rough conveyor areas\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCNC vs Competitors\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePoint\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCNC D4MC-2000\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCheap open-market copy\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eOversized heavy-duty switch\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse case fit\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGood for light machine and automation signaling\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMay work, but consistency is often poor\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eToo much switch for a small low-cost mechanism\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCost\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.600 listed price\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSometimes cheaper, often inconsistent\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHigher cost than needed for light-duty jobs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMechanical geometry\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRoller lever suits side and sweep approach\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGeometry may look similar but act poorly in service\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOften chosen only when the site is actually rough and abusive\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis limit switch does not replace overload protection, short-circuit protection or motor protection. It does not stop a power surge. It does not replace a safety-rated interlock system where machine safety legislation requires a dedicated safety device. It also does not fix bad mechanical design. If the moving bracket comes in at the wrong angle, bends the lever too hard or hits with too much force, even a good switch will give nuisance problems or fail early.\u003c\/p\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor full panel protection, pair control devices like this with the right \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003ecircuit breaker\u003c\/a\u003e, a proper \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003esurge protection device\u003c\/a\u003e, suitable \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003emagnetic contactors\u003c\/a\u003e, and if a motor is involved, a matching \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003ethermal relay\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n  \u003col style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount the switch on a rigid bracket or machine frame so it cannot shift during vibration.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eSet the striker, cam or moving tab so it touches the roller lever smoothly from the correct direction.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eAvoid over-travel that bends or hammers the lever harder than needed.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eWire it into the control circuit only after confirming the required contact logic for your panel or controller.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eRun several dry mechanical cycles before energising the full machine so the switching point is repeatable.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;font-weight:700\"\u003ePush buttons\u003c\/a\u003e for start, stop and reset functions in the same control panel.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;font-weight:700\"\u003eSelector switches\u003c\/a\u003e when the operator also needs manual mode selection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eMagnetic contactors\u003c\/a\u003e to switch motors, pumps or solenoids from the control signal.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eThermal relays\u003c\/a\u003e if the limit switch is part of a motor starter sequence.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003eCircuit breakers\u003c\/a\u003e for upstream panel protection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/industrial-products\" style=\"color:#d42027;font-weight:700\"\u003eIndustrial products\u003c\/a\u003e for other panel and automation hardware used on the same machine.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003eSPD\u003c\/a\u003e if the machine panel sits near motors, drives or a DB where surge events can damage control gear.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;font-weight:700\"\u003eFire extinguisher products\u003c\/a\u003e as the final add-on for panel-level fire response.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003eTypes of circuit breakers\u003c\/a\u003e if you are building the full panel from scratch.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/rccb-breaker-guide-pakistan-earth-leakage-protection\" style=\"color:#d42027\"\u003eSafety breaker guide\u003c\/a\u003e for broader panel protection planning.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e1. Where should I choose a roller lever instead of a roller plunger?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose a roller lever when the moving part approaches from the side, swings in an arc, or needs a little mechanical reach. A plunger works better for straight-on travel.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e2. Is D4MC-2000 good for auto gate systems?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt can suit light gate position signaling if the bracket and travel path are well aligned. For rough outdoor gate duty, make sure the mechanical mounting is solid and the motion does not hammer the lever.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e3. Can I use this switch directly on a motor power line?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. This is a control device. It should be used in a control circuit, not as the main power switching device for a motor load.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e4. Is this limit switch suitable for packaging machines?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, this is one of the better low-cost fits for packaging movement where cams, arms or product guides pass the switch from the side.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e5. Why does lever style help in low-cost automation?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBecause not every mechanism arrives perfectly straight. The lever gives more tolerance to side approach and slight angular variation.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e6. What is the listed price of D4MC-2000 in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eAt the time checked, the live product page listed D4MC-2000 at Rs.600.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e7. Can this switch be used in a PLC panel?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. That is a normal use case. It can provide a position or interlock signal to a PLC, relay logic or contactor circuit when wired correctly.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e8. What usually ruins a limit switch like this?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBad mechanical approach, hard impact, side-loading, loose mounting and using the wrong actuator style for the motion path ruin more limit switches than the brand name does.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eD4MC-2000 is the sensible low-cost pick when your machine needs lever-style travel sensing instead of a straight push point. It fits packaging, gate linkage, light machine travel and simple automation panels without pretending to be a heavy-duty mill switch. For price confirmation, stock status and selection help, contact CNC Electric Pakistan on WhatsApp 0326-1111376. Orders above Rs.10,000 qualify for free delivery, and the right control hardware can be matched with contactors, thermal relays, breakers and surge protection from the same store.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:8px\"\u003eSee also: \u003ca href=\"\/collections\/limit-switches\" style=\"color:#d42027\"\u003eLimit Switches\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n---","brand":"CNC Electric Pakistan","offers":[{"title":"10A","offer_id":43009681031234,"sku":null,"price":600.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Limit_Switch_D4MC-2000_Roller_Lever.webp?v=1771489174"},{"product_id":"limit-switch-mea-9108-heavy-duty-roller-lever-industrial-position-switch","title":"Heavy Duty Limit Switch | Industrial Roller","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eMEA-9108 heavy duty limit switch is the right choice when a light machine switch is not going to survive the site. The live Pakistan product page lists this model at Rs.1,400 with a 10A variant. That puts it in a different class from compact and light-duty limit switches. This is the model for conveyors, elevators, rough packaging lines, dusty workshops, plant travel points and hard industrial service where stronger mechanical duty matters more than a miniature body or the lowest initial price.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe real buying logic is simple. If the machine area is dirty, repetitive and mechanically rough, a small low-cost switch often becomes a false economy. The part may be cheap, but the downtime is not. A limit switch on a conveyor or travel point is not judged on day one. It is judged after dust, vibration, repeated impact and ordinary maintenance habits have tested it for months. That is where a heavy-duty switch starts to justify its price.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features and Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eFeature\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eDetails\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMEA-9108\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eActuator type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHeavy-duty adjustable roller lever\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLive listing current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e10A variant listed on the local page\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProtection style\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIP65 industrial enclosure style for dust and splash resistance in normal plant use\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest fit\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eConveyors, elevators, rugged machine travel, dusty production zones, heavy workshop duty\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWhy buyers choose it\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStronger-duty position switch for rougher environments than light or miniature switch bodies\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRelevant standard context\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIEC 60947-5-1 control-circuit device class\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis page should not read like the XCK-M M115 page or the D4MC-2000 page because the search intent is not the same. A buyer searching for a heavy duty limit switch, conveyor limit switch or industrial roller position switch is usually dealing with a harsher site, stronger motion, more vibration, more dust or a more physical mechanical environment. That changes the selection logic.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMEA-9108\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eActuator\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAdjustable roller lever\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProtection degree from official MEA family page\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIP65\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWorking range from official MEA family page\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e6A at 125V or 250VAC family reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMechanical operating frequency from official MEA family page\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e120 times per minute\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eElectrical operating frequency from official MEA family page\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e30 times per minute\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMechanical life from official MEA family page\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAbove 10,000,000 operations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eElectrical life from official MEA family page\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAbove 500,000 operations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAmbient operating temperature from official MEA family page\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e-25°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLive local price\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.1,400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBody dimensions, terminal numbering and exact contact arrangement for this local variant\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNot clearly listed on the local product page and have not been guessed\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis description uses live local sale data plus limited official MEA family data where it helps explain the switch class. Exact local drawing dimensions, terminal-number detail and variant-specific contact arrangement are not clearly published on the Pakistan product page and have not been guessed.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eHeavy duty does not mean careless installation is acceptable. It means the switch is better matched to a harder environment. A strong switch can still fail if a weak bracket flexes, the moving striker hits from the wrong angle, cable entry is left poor, or the switch is used where a different actuator geometry was required from the beginning.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range and Models\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eModel\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eConfiguration\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRating\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrice\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMEA-9108\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHeavy-duty roller-lever limit switch\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e10A local listing\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eConveyors, elevators, rugged machine travel, dusty production areas\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.1,400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eXCK-T118\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSealed industrial roller lever\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e10A local listing\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDusty or damp general industrial duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSee product page\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eD4MC-2000 \/ D4MC-5020\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLighter geometry-specific models\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e10A local listings\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCleaner machine use or motion-specific selection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSee product page\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eMEA-9108 earns its place when the environment and mechanical abuse are higher. If the machine is small and clean, you usually do not need this model. If the site is dusty, repetitive and physically rough, you probably do.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications in Pakistan\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis is the kind of switch buyers look for when they are tired of replacing lighter switches in rough service. On textile floors in Faisalabad, lint and repeated machine travel are everyday conditions. In Lahore workshops and fabrication environments, dust, vibration and harder mechanical use are common. In Karachi plant rooms, conveyors, utility systems and harsher workshop zones often need a switch body that is more confident under repeated industrial use than a light compact switch.\u003c\/p\u003e\n\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eApplication\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRecommended setup\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy this model fits\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eConveyor end-of-travel detection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMEA-9108 on rigid conveyor frame\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHeavy-duty body suits repeated travel contact and dusty sites\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eElevator or hoist position signalling\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHeavy-duty roller lever on solid mounting\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUseful where dependable mechanical travel confirmation is needed\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRough packaging line duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFrame-mounted travel or interlock switch\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBetter for frequent operation and tougher movement than lighter bodies\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSteel or fabrication workshop machine\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHeavy-duty limit switch with protected cable entry\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHandles harsher industrial life better than compact switch bodies\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDirty production or utility area\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSealed heavy-duty mechanical position switch\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStronger fit where dust, grime and repeated contact are normal\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSizing and Selection Guide\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eYour situation\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eChoose MEA-9108?\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eReason\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThe site is dirty, repetitive and mechanically rough\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThis is the core buying reason for this model\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed the smallest compact switch for a tight fixture\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually no\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA miniature model is usually better for compact layouts\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed a low-cost clean-indoor geometry-specific switch\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMaybe not\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA lighter D4MC-type switch can be enough there\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed stronger body confidence on a conveyor or heavy machine\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThis is where MEA-9108 makes commercial sense\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCNC vs Competitors\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePoint\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCNC MEA-9108\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCheap open-market copy\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eLight-duty or compact switch\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMain advantage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHeavy-duty body and better fit for rough service\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSometimes cheaper, but consistency is often poor\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFine for cleaner, lighter or tighter jobs, weaker fit for harsh service\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eConveyors, elevators, dusty production zones, rough machine travel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBudget replacement where environment is often ignored\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCleaner machine service or layout-limited applications\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSelection logic\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePick this when environment and mechanical abuse are the real issue\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePrice-first selection often leads to repeat replacement\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWrong choice when the site is physically rough and repetitive\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis limit switch does not replace a breaker, overload relay, surge protector or safety-rated interlock system. It does not solve short circuits, voltage spikes or motor overheating. It also does not compensate for poor mounting or bad striker design. If the moving equipment hits at the wrong angle, the bracket flexes or the cable entry is left poor, even a heavy-duty switch will not save the installation.\u003c\/p\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor proper machine-panel protection, pair this control device with the right \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003ecircuit breaker\u003c\/a\u003e, a suitable \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003esurge protection device\u003c\/a\u003e, the correct \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003emagnetic contactor\u003c\/a\u003e, and where motors are involved, a matching \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003ethermal relay\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n  \u003col style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount the switch on a rigid frame or bracket that does not flex during repeated machine movement.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eSet the striker, cam or moving tab so it approaches the roller lever cleanly without side abuse or violent impact.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eUse proper cable entry and sealing practice. A strong switch body still needs a proper wiring path.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eWire it only into the intended control circuit after confirming the required contact logic in the panel or controller.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eRun dry mechanical cycles first and confirm the travel point is repeatable under actual machine movement.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;font-weight:700\"\u003ePush buttons\u003c\/a\u003e for operator control on the same machine panel.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;font-weight:700\"\u003eSelector switches\u003c\/a\u003e for local\/manual mode selection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eMagnetic contactors\u003c\/a\u003e when the switch signal has to control a motor or actuator circuit.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eThermal relays\u003c\/a\u003e to protect motors used in the same machine.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003eCircuit breakers\u003c\/a\u003e for feeder and control-panel protection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/industrial-products\" style=\"color:#d42027;font-weight:700\"\u003eIndustrial products\u003c\/a\u003e for related plant-control hardware.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003eSPD\u003c\/a\u003e if the machine panel sits near drives, motors or a DB where surge stress can affect control components.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;font-weight:700\"\u003eFire extinguisher products\u003c\/a\u003e as the final panel-safety add-on.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003eTypes of circuit breakers\u003c\/a\u003e if you are planning the full panel.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/rccb-breaker-guide-pakistan-earth-leakage-protection\" style=\"color:#d42027\"\u003eSafety breaker guide\u003c\/a\u003e for wider machine-panel protection planning.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e1. Why choose MEA-9108 over a lighter limit switch?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose it when the site is rougher, dirtier and mechanically harder on the switch. That is the main commercial reason for this model.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e2. Is MEA-9108 good for conveyors in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, conveyor end-of-travel and repetitive industrial motion are among the strongest use cases for this type of heavy-duty switch.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e3. Can this model be used on elevator or hoist travel points?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, it can suit mechanical position signalling on equipment where a stronger-bodied limit switch is preferred.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e4. What price is listed for MEA-9108 in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eAt the time checked, the live Pakistan page listed MEA-9108 at Rs.1,400.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e5. Does IP65 mean the installation can be careless?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. A sealed switch body still needs proper cable entry, good bracket rigidity and correct striker geometry.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e6. Can MEA-9108 directly switch a motor power line?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. It is a control-circuit position switch, not the main power switching device for a motor circuit.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e7. What usually causes heavy-duty limit switches to fail early?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBad alignment, weak mounting, repeated hard impact, poor cable sealing and choosing the wrong actuator geometry are common reasons.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e8. When should I not choose MEA-9108?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eDo not choose it when the machine is clean, compact and lightly loaded, or when the real problem is a tight layout that needs a miniature switch instead.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eMEA-9108 is the sensible choice when a light-duty switch is simply not the right match for the site. It suits conveyors, elevators, rough packaging lines, dusty workshops and other harder industrial travel points where stronger mechanical confidence matters. For stock status, price confirmation and selection help, contact CNC Electric Pakistan on WhatsApp 0326-1111376. Orders above Rs.10,000 qualify for free delivery, and matching control hardware can be selected from the same store.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:8px\"\u003eSee also: \u003ca href=\"\/collections\/limit-switches\" style=\"color:#d42027\"\u003eLimit Switches\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n---","brand":"CNC Electric Pakistan","offers":[{"title":"10A","offer_id":43009734279234,"sku":null,"price":1400.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/CNCElectricWebsiteProductsSize_1.webp?v=1771493580"},{"product_id":"limit-switch-xck-t118-roller-lever-ip65-industrial-micro-position-switch","title":"Limit Switch XCK-T118 Roller Lever | IP65 Industrial","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eXCK-T118 IP65 limit switch is the better choice when the machine area is rougher than a clean compact fixture and you still want a roller-lever head. The live Pakistan listing shows this model at 10A and Rs.1,400. That puts it in a different buying class from the lighter limit switches in this group. This one is for textile floors, dusty workshops, semi-outdoor gate systems, hoists, utility rooms and general industrial machine duty where sealing and body style matter more than compact size.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA lot of buyers make the wrong comparison here. They compare only on price. The better comparison is environment. If the switch sits near lint, dust, splash, coolant mist, dampness or rough handling, the question is not “Can a small light switch do the job?” The question is “Will that switch keep doing the job after real site use?” That is where XCK-T118 becomes the sensible step up.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features and Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eFeature\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eDetails\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eXCK-T118\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eActuator type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRoller lever\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLive listing current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e10A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProtection style\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIP65 industrial positioning for dust and water resistance in normal site use\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMain buying reason\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBetter environmental suitability than lighter open or compact switch styles\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest fit\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDusty shops, textile machines, packaging lines, gate automation, hoists, damp plant rooms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRelevant standard context\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIEC 60947-5-1 control-circuit device class\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product should not be written like the D4MC-2000 page or the M115 page because the buying reason is different. D4MC-2000 is about general low-cost lever duty. M115 is about compact space. XCK-T118 is about surviving a rougher environment with a more industrial body style. That difference matters because most switch failures in Pakistan do not happen on the sales counter. They happen months later on the machine, after dust, splash, vibration and bad cable practice have done their work.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eXCK-T118\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eActuator\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRoller lever\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated current on live page\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e10A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProtection degree used on live page\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIP65 industrial enclosure style\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTypical use\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMechanical position sensing and end-of-travel signalling\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMounting style\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMachine body or rigid bracket mounting\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePreferred environment\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDusty, damp or harsher industrial locations compared with lighter switch styles\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eControl use\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePLC input, interlock logic, starter control circuits, machine stop chains\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBody dimensions, operating force and terminal numbering\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNot currently listed on the live product page and have not been guessed\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis description uses only data published on the live product page. Exact drawing dimensions, head-travel figures, contact arrangement detail, operating force and cable-entry hardware are not currently listed on the live product page and have not been guessed.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIP65 in practical Pakistani use means the switch body is better suited to dirty and splash-prone environments than open or lightly protected components. It does not mean you can pressure-wash it, leave the cable entry loose, ignore conduit sealing or mount it on a vibrating weak bracket. A sealed switch body with poor installation is still a poor installation.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range and Models\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eModel\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eConfiguration\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRating\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrice\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eXCK-T118\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIP65 roller-lever limit switch\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e10A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDusty and damp industrial duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.1,400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eD4MC-2000\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGeneral roller-lever switch\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e10A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCleaner indoor machinery and low-cost lever duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSee product page\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eXCK-M M115\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCompact miniature roller lever\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTight-space compact control duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSee product page\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eXCK-T118 is the sensible step when you want a roller lever but the site is rougher than a clean compact machine. It is the environment-first option in this group.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications in Pakistan\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis model fits the buyer who says the area is not gentle. On textile floors in Faisalabad, lint and everyday machine dust are normal. In fabrication and workshop settings in Lahore, fine dust, vibration and rough handling are part of normal work. In Karachi, semi-outdoor production spaces, plant rooms and gate systems often need a switch body that is more tolerant of dampness and grime than a lighter open design. That is the lane for XCK-T118.\u003c\/p\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eApplication\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRecommended setup\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy this model fits\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTextile machine travel detection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eXCK-T118 with sealed cable entry practice\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBetter suited to lint, dust and daily plant duty\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOutdoor or semi-outdoor gate automation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIP65 roller lever on rigid bracket\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHandles weather exposure better than lighter control switches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePackaging line position proof\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMounted on conveyor or pusher frame\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUseful in dusty production lines with frequent operation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWorkshop machine guard interlock\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSealed switch body with good conduit practice\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGives more confidence where coolant mist and grime exist\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHoist or travel-end signalling\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFixed machine frame mounting\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSuited to general industrial end-limit control\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePump house or plant room service doors\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIndustrial sealed limit switch\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUseful where dampness and dirt are normal\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSizing and Selection Guide\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eYour situation\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eChoose XCK-T118?\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYou need dust and splash resistance\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSealed industrial form is the main advantage here\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed a compact switch in a tiny machine space\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually no\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eM115 is usually better when space is the main problem\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed the cheapest indoor lever switch only\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMaybe not\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eD4MC-type lever can be enough in a cleaner lighter job\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThe site is dirty, damp and handled roughly\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThat is the core buying reason for this model\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCNC vs Competitors\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePoint\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCNC XCK-T118\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCheap open-market copy\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eLighter non-sealed lever switch\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMain advantage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIndustrial sealed body for rougher environments\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMay be cheaper, but consistency is often poor\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFine in cleaner indoor service, weaker fit for dirty damp areas\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDusty shops, textile floors, gate duty, plant rooms\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBudget replacement where environment is often ignored\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGeneral low-cost machinery in cleaner surroundings\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSelection logic\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePick this when the environment is the real problem\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePrice-first selection often leads to early nuisance issues\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWrong pick if the site is dirty, wet or semi-outdoor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis limit switch does not replace a breaker, overload relay, surge protector or safety-rated interlock system. It does not solve short circuits, motor overheating or voltage spikes. It also does not fix bad installation. If the cable entry is loose, the bracket flexes, water tracks into the wiring path or the moving part slams the lever harder than it should, even an IP65-style switch will give trouble.\u003c\/p\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor proper panel protection, pair control devices like this with the right \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003ecircuit breaker\u003c\/a\u003e, a suitable \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003esurge protection device\u003c\/a\u003e, the correct \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003emagnetic contactor\u003c\/a\u003e, and where motors are involved, a matching \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003ethermal relay\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n  \u003col style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount the switch on a rigid machine body or bracket so vibration does not alter the switching point.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eUse proper cable entry and sealing practice. The body rating is only useful if the installation is also sealed properly.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eSet the moving tab, cam or arm so it touches the roller lever smoothly instead of hammering it.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eWire it only into the intended control circuit after confirming the required contact logic in the panel.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eTest several dry mechanical cycles first and confirm that the switching point remains stable under actual movement.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;font-weight:700\"\u003ePush buttons\u003c\/a\u003e for start and stop control on the same industrial panel.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;font-weight:700\"\u003eSelector switches\u003c\/a\u003e for mode selection or local\/manual control.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eMagnetic contactors\u003c\/a\u003e when the switch signal has to control a motor or actuator circuit.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eThermal relays\u003c\/a\u003e to protect motors used in the same machine.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003eCircuit breakers\u003c\/a\u003e for feeder and control-panel fault protection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/industrial-products\" style=\"color:#d42027;font-weight:700\"\u003eIndustrial products\u003c\/a\u003e for the rest of the plant-control hardware.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003eSPD\u003c\/a\u003e if the machine or gate panel sits near a DB, drive or motor circuit where surge stress can affect control components.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;font-weight:700\"\u003eFire extinguisher products\u003c\/a\u003e as the final panel-safety add-on.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003eTypes of circuit breakers\u003c\/a\u003e if you are planning the complete panel.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/rccb-breaker-guide-pakistan-earth-leakage-protection\" style=\"color:#d42027\"\u003eSafety breaker guide\u003c\/a\u003e for wider panel protection planning.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e1. Why choose XCK-T118 over a lighter limit switch?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose it when the environment is dirtier, splash-prone or generally rougher. That is the main reason this model exists.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e2. Is XCK-T118 good for textile machines in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, especially where lint, dust and daily machine use are part of the environment and a lighter switch body would be a weaker fit.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e3. Can this model be used for gate automation?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, it can suit outdoor or semi-outdoor gate position signalling when installed on a rigid bracket with proper sealing practice.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e4. Does IP65 mean it is safe against any water condition?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. It is better suited to dust and practical splash exposure, but it is not a licence for careless mounting, open cable entry or direct abuse.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e5. What price is listed for XCK-T118 in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eAt the time checked, the live product page listed it at Rs.1,400.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e6. Can this switch directly power a motor load?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. It is a control device for signalling and interlock logic, not the main power switch for a motor circuit.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e7. What usually ruins even a sealed limit switch?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eLoose cable entry, weak mounting, bad alignment, heavy impact and poor conduit practice ruin more switches than the IP label alone can save.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e8. Is this a better choice than a compact miniature switch for tight enclosures?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNot usually. If compact space is the main issue, a miniature model is often better. XCK-T118 is bought mainly for environment and industrial body style.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eXCK-T118 is the right choice when you need a roller-lever limit switch but the area is rougher than a clean compact machine space. It suits textile lines, dusty workshops, gate systems, hoists, plant rooms and other harsher industrial jobs where a more sealed industrial form makes sense. For stock status, price confirmation and selection help, contact CNC Electric Pakistan on WhatsApp 0326-1111376. Orders above Rs.10,000 qualify for free delivery, and matching control hardware can be selected from the same store.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:8px\"\u003eSee also: \u003ca href=\"\/collections\/limit-switches\" style=\"color:#d42027\"\u003eLimit Switches\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n---","brand":"CNC Electric Pakistan","offers":[{"title":"10A","offer_id":43009750925378,"sku":null,"price":1400.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Limit_Switch_XCK-T118_Roller_Lever.webp?v=1771495976"},{"product_id":"limit-switch-xck-m-m115-roller-lever","title":"Limit Switch XCK-M M115 Mini Roller Lever | IP65 Compact","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eXCK-M M115 limit switch is the better choice when a normal-size industrial switch feels bulky for the job. The live product page lists this miniature roller-lever model at 3A and Rs.1,400. That puts it in a very different lane from a larger 10A lever switch. This one is for compact guards, small jigs, robotic fixtures, mini slides and neat PLC input duty where space matters as much as switching.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIf your machine is small, tidy and movement is light, a compact body often solves more problems than a heavier switch. In Sialkot fixture work, small presses and light assembly rigs often do not need a large industrial body hanging off the side. In Lahore machine-building and panel jobs, the challenge is often simple: fit the switch cleanly, keep the signal repeatable and avoid extra mechanical clutter inside a tight enclosure or moving mechanism.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features and Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eFeature\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eDetails\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eXCK-M M115\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eActuator type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMini roller lever\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated current on listing\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3A control-duty class\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated voltage shown in listing snippet\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e240V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eInsulation voltage shown in listing snippet\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUi 500V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest fit\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTight automation spaces, compact guards, mini slides, robotic fixtures, low-current control duty\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRelevant standard context\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIEC 60947-5-1 control-circuit device class\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe main reason to buy M115 is not just that it is smaller. It is that a compact mechanism often gives a cleaner layout in light automation. On a small jig, 3D-printer style motion assembly, feeder slide, printing fixture or guard interlock bracket, a full-size heavy switch can become the problem. It takes space, it interferes with motion, and it makes neat adjustment harder. This model is for buyers who want a compact mechanical signal, not a heavy plant switch.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProduct type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMini industrial limit switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHead style\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eM115 adjustable roller lever type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated voltage shown on product snippet\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e240V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated current shown on product snippet\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3A AC-15 style control duty\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eInsulation voltage shown on product snippet\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e500V Ui\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWiring method shown on product snippet\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eScrew terminal style control wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eControl use\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePosition feedback, interlock, home signal, stop signal, proof-of-position\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFull dimensions and operating-force values\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNot clearly published on the live Pakistan page and have not been used as fixed sales facts\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis description uses only data published on the live product page for the local sale listing. Exact travel figures, operating force, terminal numbering, full body drawing and switching differential are not currently listed on the live product page and have not been guessed.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range and Models\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eModel\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eHead type\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCurrent\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrice\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eXCK-M M115\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMini roller lever\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCompact automation, small guards, robotic fixtures, PLC input duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.1,400\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eIf your motion problem is...\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eThis model fits?\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTiny machine envelope and short lever travel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCompact body is the main advantage here\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed to switch bigger power directly\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNo\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThis is a control-duty signal device, not a power switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHarsh dusty mill or rough conveyor site\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually no\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA heavier industrial body is a safer choice there\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed a clean signal in a neat compact fixture\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThat is where M115 makes sense\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications in Pakistan\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eM115 is not the switch for every workshop. It is the switch for compact movement and clean low-current signaling. In Sialkot, that can mean small tool-room fixtures, compact jig work or light assembly rigs. In Lahore, it can suit packing heads, mini feeder movements, guard-position sensing or neat control-duty brackets where a larger switch body gets in the way. In Karachi, small automation panels and bench-type machines often benefit from a compact limit switch because cable routing and bracket space are already tight.\u003c\/p\u003e\n\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eApplication\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRecommended use\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy this model fits\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCompact fixture or jig\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as end-point or cycle-complete signal\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSmall body suits restricted mounting space\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3D-printer style or linear-slide motion\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as home or limit reference\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCompact lever works where motion is light and geometry is tight\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSmall guard door or flap\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as position or interlock feedback\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMini head helps where a full-size switch would obstruct movement\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRobotic fixture or bench automation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as proof-of-position signal\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGood for neat low-current control logic\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMini feeder or label applicator movement\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse as stop-point or repeat position signal\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCompact lever arrangement reduces bracket crowding\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSizing and Selection Guide\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eYour machine condition\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eChoose XCK-M M115?\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eReason\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSpace is tight and signal current is light\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThis is exactly the design reason for this model\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed broader mechanical reach from a larger moving arm\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMaybe not\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA larger roller-lever body may suit that motion better\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed a straight direct-hit travel point\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually no\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA plunger style is often cleaner for that job\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed survival in rough, dirty, high-impact environment\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNo\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePick a heavier industrial switch body\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCNC vs Competitors\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePoint\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCNC XCK-M M115\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eGeneric miniature switch\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eFull-size lever switch\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMain advantage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCompact body for tight layouts\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMay be cheap, but layout quality and consistency vary\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBetter when the site has room and motion is broader\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eControl duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3A compact control-duty class\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOften poorly documented\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually larger and sometimes unnecessary for compact jobs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTight automation spaces and neat fixtures\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBudget replacement where precision expectations are low\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGeneral machine travel where body size is not an issue\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis limit switch does not replace a safety-rated interlock, overload relay, breaker or surge protector. It is not a motor-protection device and it is not the right answer for rough shock-heavy plant duty. It also does not solve bad bracket design. If the moving part hits at the wrong angle or overtravels too hard, the switch will not compensate for poor mechanics.\u003c\/p\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIf your panel also needs protection and switching, add a proper \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003ecircuit breaker\u003c\/a\u003e, a suitable \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003esurge protection device\u003c\/a\u003e, the correct \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003emagnetic contactor\u003c\/a\u003e, and where motors are involved, a matching \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003ethermal relay\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n  \u003col style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eUse this model only where the machine layout truly benefits from a compact switch body.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount it on a rigid bracket so alignment does not drift during repeated motion.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eSet the moving tab or striker to touch the lever smoothly without slamming the head.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eWire it only into the intended control circuit after checking the required contact logic.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eCycle the machine by hand first and confirm repeatable switching before live operation.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;font-weight:700\"\u003ePush buttons\u003c\/a\u003e for start and stop control on the same compact machine.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;font-weight:700\"\u003eSelector switches\u003c\/a\u003e if the panel also needs mode selection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eMagnetic contactors\u003c\/a\u003e when the limit signal needs to switch a motor-control circuit.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eThermal relays\u003c\/a\u003e to protect motors used in the same machine.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003eCircuit breakers\u003c\/a\u003e for upstream fault protection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/industrial-products\" style=\"color:#d42027;font-weight:700\"\u003eIndustrial products\u003c\/a\u003e for the rest of the machine-control hardware.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003eSPD\u003c\/a\u003e if the compact machine sits near a DB, drive or motor panel where surge stress can affect control components.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;font-weight:700\"\u003eFire extinguisher products\u003c\/a\u003e as the final panel-safety add-on.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003eTypes of circuit breakers\u003c\/a\u003e if you are also building the feeder panel.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/rccb-breaker-guide-pakistan-earth-leakage-protection\" style=\"color:#d42027\"\u003eSafety breaker guide\u003c\/a\u003e for wider protection planning.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e1. Why choose XCK-M M115 over a normal-size lever switch?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose it when layout space is limited and the job is light control-duty sensing. That is the whole point of this model.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e2. Is this good for 3D printer style motion or small linear slides?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, that type of compact motion system is a much better fit for this switch than heavy plant machinery.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e3. Can I use XCK-M M115 as a PLC input signal switch?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. That is one of the normal applications for a compact control-duty limit switch like this.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e4. Is this model suitable for dirty heavy conveyor sites?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eUsually no. For rough heavy-duty sites, a stronger industrial switch body is the better choice.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e5. What price is listed for XCK-M M115 in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eAt the time checked, the live product page listed it at Rs.1,400.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e6. Can this switch directly power a motor or solenoid load?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. Use it as a control signal device, not as the main power switching device for a motor load.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e7. What usually causes trouble with miniature limit switches?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003ePoor bracket rigidity, bad alignment, overtravel, hard impact and using a compact switch where a heavy-duty one is actually needed.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e8. Is XCK-M M115 a good fit for compact guard sensing?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, especially when the guard mechanism is small and there is not enough room for a larger lever or plunger switch.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eXCK-M M115 is the smart choice when you need a neat compact limit switch and do not want a larger body complicating the machine layout. It is better suited to jigs, mini slides, compact guards, bench automation and PLC input duty than to rough heavy industrial punishment. For price confirmation, stock status and selection help, contact CNC Electric Pakistan on WhatsApp 0326-1111376. Orders above Rs.10,000 qualify for free delivery, and matching control hardware can be selected from the same store.\u003c\/p\u003e\n\u003c\/div\u003e\n---","brand":"CNC Electric Pakistan","offers":[{"title":"3A","offer_id":43009753940034,"sku":null,"price":1400.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Limit_Switch_XCK-M_M115_Roller_Lever.webp?v=1771496591"},{"product_id":"digital-time-relay-dh48s-2z-ac-dc-12v-380v","title":"Power ON Delay Timer | Industrial Relay","description":"\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eDH48S Digital Time Relay\u003c\/b\u003e is a high-precision multifunction timer relay designed for industrial automation, control panels, switchgear systems, and electrical machinery. Built with reliable electronic components and a clear digital display, this \u003cb\u003epower-on delay timer relay\u003c\/b\u003e ensures accurate timing control across a wide voltage range.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis model supports both \u003cb\u003eAC and DC supply voltage (DC 12V–48V \/ AC 24V–380V, 50Hz)\u003c\/b\u003e, making it ideal for industrial control circuits, motor control systems, distribution boards, and automation panels.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe DH48S series offers two operation modes:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e1Z\u003c\/b\u003e – Power ON Delay with Reset \u0026amp; Gate\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e2Z\u003c\/b\u003e – Power ON Delay\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eWith a compact 48×48mm panel size and strong electrical insulation, it is a perfect solution for panel builders, OEM manufacturers, and electrical contractors looking for a dependable \u003cb\u003eindustrial timer relay\u003c\/b\u003e.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eKey Features\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l4 level1 lfo5;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003eWide Voltage Range: DC 12V–48V \/ AC 24V–380V (50Hz)\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l4 level1 lfo5;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eMultifunction Time Relay (Power ON Delay)\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l4 level1 lfo5;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eHigh Accuracy Digital Display Timer\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l4 level1 lfo5;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eStrong 5A 220V AC Control Output\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l4 level1 lfo5;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eDurable Mechanical Life up to 10\u003cspan style=\"mso-ascii-font-family: Calibri; mso-hansi-font-family: Calibri; mso-bidi-font-family: Calibri;\"\u003e⁷\u003c\/span\u003e Operations\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l4 level1 lfo5;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eCompact 48\u003cspan style=\"mso-ascii-font-family: Calibri; mso-hansi-font-family: Calibri; mso-bidi-font-family: Calibri;\"\u003e×\u003c\/span\u003e48mm Panel Mount Design\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l4 level1 lfo5;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eSuitable for Automation Panels \u0026amp; Control Boards\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eTime Setting Range\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe CNC DH48S Timer Relay supports multiple adjustable time ranges:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e0.01 Seconds – 99.99 Seconds\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e1 Second – 99 Minutes 99 Seconds\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list .5in;\"\u003e1 Minute – 99 Hours 99 Minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThis flexible time adjustment makes it ideal for both short-delay automation tasks and long-duration control operations.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe DH48S Digital Timer Relay is widely used in:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eIndustrial Automation Systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eElectrical Control Panels\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eMotor Starters \u0026amp; Pump Control\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eConveyor Systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eGenerator Panels\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eDistribution Boards (DB)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eSwitchgear \u0026amp; Control Cabinets\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003ePackaging \u0026amp; Processing Machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eWhy Choose CNC Electric DH48S Time Relay?\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eCNC Electric is known globally for reliable low-voltage electrical components. The DH48S series combines:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo4; tab-stops: list .5in;\"\u003eStable timing accuracy\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo4; tab-stops: list .5in;\"\u003eIndustrial-grade durability\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo4; tab-stops: list .5in;\"\u003eWide voltage compatibility\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo4; tab-stops: list .5in;\"\u003eEasy panel installation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo4; tab-stops: list .5in;\"\u003eLong operational life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eIt is engineered for professional electricians, automation engineers, and panel manufacturers who demand reliability and performance. For over and under voltage protection, add a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color: #d42027;\"\u003evoltage protector\u003c\/a\u003e to your board.\u003c\/p\u003e\n\u003cdiv style=\"margin-top: 15px; font-size: 14px;\"\u003e\n\u003cstrong\u003e📖 Related Guides:\u003c\/strong\u003e\n\u003cul style=\"padding-left: 18px; margin-top: 5px;\"\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/contactor-vs-relay-difference-when-to-use-pakistan\" style=\"color: #d42027;\"\u003eContactor vs Relay Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/magnetic-contactor-wiring-guide-pakistan-connection-diagram\" style=\"color: #d42027;\"\u003eMagnetic Contactor Wiring Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.6; margin-bottom: 8px;\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/timer-switch-guide-pakistan-digital-timer-relay-types-wiring\" style=\"color: #d42027;\"\u003eTimer Switch Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"Default Title","offer_id":43011165618242,"sku":null,"price":2200.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Digital_Time_Relay_DH48S-2Z.webp?v=1771567345"},{"product_id":"digital-time-relay-dh48s-s-220v-ac-output","title":"Digital Time Relay | Multi-Voltage Timer","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eLooking for a \u003ca href=\"\/collections\/timer-ah2n\" style=\"color:#d42027;\"\u003edigital timer relay\u003c\/a\u003e price in Pakistan for a panel, machine, motor circuit, or automatic control setup? This CNC Electric duty-cycle timer relay is listed at Rs. 2,200 and is built for control jobs where the output must repeat ON and OFF timing in a controlled pattern instead of giving only a one-time delay. For Pakistani panel builders, electricians, OEM workshops, and factory maintenance teams, it is a practical industrial timer switch when you need repeat-cycle timing in control panels, PLC-linked cabinets, pump logic, and machinery panels without depending on manual switching.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eDigital time relay for industrial automation panels, distribution boards, control systems, and machinery timing.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong\u003eDuty-cycle operation\u003c\/strong\u003e timer for repeated ON\/OFF timing rather than only a simple power-on delay.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eWide voltage: DC 12V–48V and AC 24V–380V 50Hz for flexible industrial and commercial use.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eLow power consumption: DC 1.0W \/ AC 1.0VA.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e5A 220V AC output for relay logic, \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003econtactor\u003c\/a\u003e control, pump sequencing, and auxiliary switching.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eCompact 45×45 mm panel cut-out for clean installation inside \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB boxes\u003c\/a\u003e and control cabinets.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eHigh insulation resistance and dielectric strength for industrial confidence.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eBetter than a manual \u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;\"\u003eselector switch\u003c\/a\u003e when the circuit needs automatic cyclic timing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003ePublished Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eDH48S-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eAction Form\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eS (Duty-cycle operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eDC 12V–48V \/ AC 24V–380V 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eDC 1.0W \/ AC 1.0VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOutput\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e5A 220V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eInsulation\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e≥100MΩ (DC 500V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eDielectric\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e1500VAC \/ 1000VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eTemperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eMechanical Life\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e10\u0026amp;sup7; operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePanel Cut-Out\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e45 × 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePrice\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs. 2,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003ePump-control panels needing repeated ON\/OFF timing.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eConveyor systems and machinery lines with controlled timing patterns.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003ePLC-linked control systems requiring cyclic relay timing.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eMotor-control circuits using \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003econtactors\u003c\/a\u003e and \u003ca href=\"\/collections\/phase-sequence-relay\" style=\"color:#d42027;\"\u003ephase sequence relays\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eAutomation boards in Lahore, Faisalabad, or Karachi for repeatable control.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003ePanels with \u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;\"\u003epush buttons\u003c\/a\u003e, \u003ca href=\"\/collections\/indicator-lights\" style=\"color:#d42027;\"\u003eindicator lights\u003c\/a\u003e, and \u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;\"\u003eselector switches\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSizing \/ Selection Guide\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong\u003eChoose this model\u003c\/strong\u003e for repeated ON\/OFF timing in process control, pump logic, or machine cycling.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong\u003eChoose a simple on-delay timer\u003c\/strong\u003e if only one delayed action is needed.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong\u003eCheck supply voltage\u003c\/strong\u003e matches your actual control circuit.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong\u003eCheck output duty\u003c\/strong\u003e — heavier loads need a \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003econtactor\u003c\/a\u003e, not direct timer switching.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong\u003ePlan panel layout\u003c\/strong\u003e around 45×45 mm cut-out with \u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;\"\u003epush buttons\u003c\/a\u003e, \u003ca href=\"\/collections\/indicator-lights\" style=\"color:#d42027;\"\u003elights\u003c\/a\u003e, and \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ebreakers\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTimer Relay vs Alternatives — Why CNC?\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eFactor\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eCNC Electric\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eSchneider\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eABB\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eChint\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eClopal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBest fit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eAutomation cabinets, machinery, pump panels\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePremium control systems\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eHigher-spec industrial\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eMainstream industrial\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBudget local control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePairing\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eWith \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003econtactors\u003c\/a\u003e, \u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;\"\u003ebuttons\u003c\/a\u003e, \u003ca href=\"\/collections\/indicator-lights\" style=\"color:#d42027;\"\u003elights\u003c\/a\u003e, \u003ca href=\"\/collections\/fuses\" style=\"color:#d42027;\"\u003efuses\u003c\/a\u003e, \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ebreakers\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eLarger ecosystems\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePremium ecosystems\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eMixed-brand jobs\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eLow-budget builds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eNot a protection breaker — does not replace \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ebreakers\u003c\/a\u003e, \u003ca href=\"\/collections\/fuses\" style=\"color:#d42027;\"\u003efuses\u003c\/a\u003e, or \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCCB\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eNot a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protector\u003c\/a\u003e for unstable mains.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eNot an \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e for surge or lightning protection.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eNot for heavy direct motor loads — use a \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003econtactor\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eDoes not correct bad wiring, wrong logic, or poor earthing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n\u003col style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eConfirm control supply voltage matches the timer relay.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003ePrepare 45×45 mm panel opening and mount inside a control panel or \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eenclosure\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eWire into the cyclic control circuit for your application.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eUse a \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003econtactor\u003c\/a\u003e for loads larger than 5A output capacity.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eTest duty cycle before handover.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eCombine with \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ebreakers\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e, and the \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027;\"\u003eFire Extinguisher Guide\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCross-Category Links\u003c\/h2\u003e\n\u003cdiv style=\"margin-top:25px;padding:15px;background:#f9f9f9;border:1px solid #e0e0e0;border-radius:5px;\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin-bottom:10px;\"\u003eComplete Your Control Panel\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/timer-ah2n\" style=\"color:#d42027;\"\u003eTimer Switches\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003eMagnetic Contactors\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;\"\u003ePush Buttons\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/indicator-lights\" style=\"color:#d42027;\"\u003eIndicator Lights\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/selector-switch\" style=\"color:#d42027;\"\u003eSelector Switches\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/phase-sequence-relay\" style=\"color:#d42027;\"\u003ePhase Sequence Relays\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003eCircuit Breakers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSurge Protection Devices\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📖 \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of Circuit Breakers Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:0;\"\u003e📖 \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027;\"\u003eFire Extinguisher Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px\"\u003e⚡ \u003ca href=\"\/blogs\/guides\/timer-switch-guide-pakistan-digital-timer-relay-types-wiring\" style=\"color:#d42027\"\u003eTimer Switch Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is a digital timer relay?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA control device that switches output according to a programmed time pattern. This model provides repeating duty-cycle control.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat does duty-cycle operation mean?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eRepeated ON\/OFF timing behavior, useful for cyclic control in automation, machinery, and pump applications.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan this work in PLC and automation panels?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. The live page positions it for automation panels, control systems, and PLC systems.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I use it in pump panels or conveyors?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. Those are two of its clearest published applications.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the digital timer relay price in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eRs. 2,200 on the live CNC Electric Pakistan listing.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this better than a manual timer switch?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, when the application needs repeatable automatic timing instead of operator-dependent manual switching.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan this relay switch heavy motor current directly?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBetter used as a control-stage device. Heavy motor loads should go through a \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003emagnetic contactor\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eHow is it installed?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIn a 45×45 mm panel cut-out, wired into the control logic. Verify voltage, output load, and timing before energizing.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat should I pair with this timer relay?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003e\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003eContactors\u003c\/a\u003e, \u003ca href=\"\/collections\/push-button\" style=\"color:#d42027;\"\u003epush buttons\u003c\/a\u003e, \u003ca href=\"\/collections\/indicator-lights\" style=\"color:#d42027;\"\u003eindicator lights\u003c\/a\u003e, proper \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ebreaker protection\u003c\/a\u003e, and good fire safety practice.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhy choose CNC Electric over unbranded timers?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBranded timer relay with published specs, industrial insulation values, and local support vs. an unbranded timer that may fail under repeated duty cycling.\u003c\/p\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor a practical duty-cycle timer relay for automation, PLC panels, conveyors, pump controls, or cyclic machinery in Pakistan, this CNC Electric DH48S-S brings repeat-cycle timing, wide AC\/DC input, and a familiar industrial panel format. For stock confirmation, wiring help, or advice on pairing with contactors and protective devices, contact CNC Electric Pakistan on WhatsApp before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"Default Title","offer_id":43011168141378,"sku":null,"price":2200.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/COUNTERSRELAYDH48S-S.webp?v=1793457704"}],"url":"https:\/\/www.cncelectric.pk\/collections\/control-panel.oembed","provider":"CNC Electric Pakistan","version":"1.0","type":"link"}