{"title":"Circuit Breakers","description":"\u003cp class=\"cnc-freshness-stamp\" style=\"color:#666;font-size:13px;margin:0 0 12px;\"\u003eUpdated: June 2026 · CNC Electric Pakistan\u003c\/p\u003e\n\u003caside class=\"cnc-related-guides\" style=\"background:#f0f9ff;border-left:4px solid #0284c7;padding:16px 20px;margin:0 0 24px;border-radius:6px;\"\u003e\n  \u003cp style=\"margin:0 0 8px;font-weight:600;color:#0c4a6e;\"\u003eCircuit Breaker Buying Guides (Updated June 10, 2026)\u003c\/p\u003e\n  \u003cul style=\"margin:6px 0 0 18px;padding:0;color:#0c4a6e;line-height:1.7;\"\u003e\n    \u003cli\u003e\u003ca href=\"\/blogs\/guides\/difference-between-mcb-mccb-rccb-rcbo-pakistan-2026-buyer-comparison-guide\" style=\"color:#0369a1;\"\u003eMCB vs MCCB vs RCCB vs RCBO — Pakistani buyer comparison\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"\/blogs\/guides\/best-electrical-equipment-tiers-pakistan-2026-iec-certification-buyer-guide\" style=\"color:#0369a1;\"\u003eBest Electrical Equipment Tiers — 5-tier IEC certification framework\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"\/blogs\/guides\/switch-board-price-in-pakistan-2026-distribution-board-msb-buyer-guide\" style=\"color:#0369a1;\"\u003eSwitch Board Price 2026 — DB, MSB, MCC, PCC guide\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"\/blogs\/guides\/rcbo-price-in-pakistan-2026-type-ac-a-b-buyer-guide\" style=\"color:#0369a1;\"\u003eRCBO Type AC vs A vs B Buyer Guide\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"\/blogs\/guides\/best-breaker-for-1-5-ton-ac-in-pakistan-2026-complete-protection-bundle\" style=\"color:#0369a1;\"\u003eBest Breaker for 1.5-Ton AC in Pakistan 2026\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"\/blogs\/guides\/best-breaker-for-3-ton-ac-in-pakistan-2026-complete-protection-bundle\" style=\"color:#0369a1;\"\u003eBest Breaker for 3-Ton AC in Pakistan 2026\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"\/blogs\/guides\/wifi-mcb-wifi-breaker-pakistan-2026-smart-circuit-protection-buyer-guide\" style=\"color:#0369a1;\"\u003eWiFi MCB \/ WiFi Breaker Pakistan 2026\u003c\/a\u003e\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/aside\u003e\n\u003cdiv class=\"cnc-quick-answer\" style=\"background:#fef3c7;border-left:4px solid #f59e0b;padding:18px 22px;margin:0 0 28px;border-radius:6px;\"\u003e\n\u003ch2 style=\"margin-top:0;font-size:1.15em;\"\u003eCircuit Breaker — Pakistan Quick Answer (May 2026)\u003c\/h2\u003e\n\u003cp\u003eA \u003cstrong\u003ecircuit breaker\u003c\/strong\u003e in Pakistan automatically disconnects an electrical circuit when current exceeds a safe limit, protecting wiring and appliances from overload, short circuit, or earth fault. CNC Electric stocks the full range — \u003cstrong\u003eMCB\u003c\/strong\u003e (miniature, for homes), \u003cstrong\u003eMCCB\u003c\/strong\u003e (moulded case, for higher current), \u003cstrong\u003eRCCB\u003c\/strong\u003e (residual-current, shock protection), \u003cstrong\u003eRCBO\u003c\/strong\u003e (combined MCB+RCCB), and \u003cstrong\u003eACB\u003c\/strong\u003e (air, for industrial). Prices range from \u003cstrong\u003eRs. 245 (1P 6A MCB)\u003c\/strong\u003e to \u003cstrong\u003eRs. 95,000 (4P 1600A ACB)\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ctable style=\"border-collapse:collapse;width:100%;margin:14px 0;font-size:14px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eType\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eBest for\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eCurrent Range\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eCNC 2026 Price (PKR)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e\n\u003cstrong\u003eMCB\u003c\/strong\u003e (Miniature)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eHome, shop, lighting, AC circuits\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e6A – 125A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e\u003cstrong\u003e245 – 1,800\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e\n\u003cstrong\u003eMCCB\u003c\/strong\u003e (Moulded Case)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eSub-main DBs, motors, panels\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e15A – 1600A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e\u003cstrong\u003e1,200 – 35,000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e\n\u003cstrong\u003eRCCB\u003c\/strong\u003e (Residual Current)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eShock protection, bathroom, kitchen\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e25A – 100A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e\u003cstrong\u003e1,500 – 4,200\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e\n\u003cstrong\u003eRCBO\u003c\/strong\u003e (MCB + RCCB)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eSingle-module shock + overload\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e6A – 63A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e\u003cstrong\u003e1,800 – 4,800\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e\n\u003cstrong\u003eACB\u003c\/strong\u003e (Air, Industrial)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eFactories, main switchgear 400V+\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e630A – 6300A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e\u003cstrong\u003e25,000 – 95,000+\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e\n\u003cstrong\u003eDC MCB\u003c\/strong\u003e (Solar)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eSolar PV strings, 500V \/ 1000V DC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e6A – 63A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e\u003cstrong\u003e650 – 3,200\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"margin-bottom:4px;\"\u003e\u003cstrong\u003eQuick decision:\u003c\/strong\u003e For Pakistani home DB box → \u003cstrong\u003e1P 16A MCB Rs. 245\u003c\/strong\u003e (lights), \u003cstrong\u003e1P 20A or 1P 32A MCB Rs. 280–350\u003c\/strong\u003e (sockets + AC). For 3-phase house → \u003cstrong\u003e4P 63A MCB Rs. 1,800\u003c\/strong\u003e. All CNC breakers: \u003cstrong\u003eIEC 60898\u003c\/strong\u003e \/ IEC 60947, \u003cstrong\u003ePSQCA-approved\u003c\/strong\u003e, 1-year warranty.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:0;\"\u003e\u003cstrong\u003eRead also:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.cncelectric.pk\/blogs\/guides\/mccb-breaker-price-in-pakistan-2026-buying-guide\"\u003eMCCB Buying Guide\u003c\/a\u003e · \u003ca href=\"https:\/\/www.cncelectric.pk\/blogs\/guides\/acb-air-circuit-breaker-price-in-pakistan-2026-buying-guide\"\u003eACB Buying Guide\u003c\/a\u003e · \u003ca href=\"https:\/\/www.cncelectric.pk\/blogs\/guides\/circuit-breaker-price-in-pakistan-complete-price-list-2026\"\u003eComplete Price List 2026\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"collection-seo-content\"\u003e\n\n\u003ch2\u003eCircuit Breaker Price in Pakistan 2026 — Complete MCB Buyer's Guide\u003c\/h2\u003e\n\u003cp\u003eA circuit breaker — sometimes called an MCB, breaker switch, or simply \"breaker\" — automatically disconnects an electrical circuit the instant it detects an overload, short-circuit, or other fault. Every Pakistani home, shop, and factory needs them: 95% of household electrical fires start from circuits without proper breaker protection. CNC Electric stocks the YCB7-63 (AC) and YCB8-63 \/ YCB1-125 (DC) series in single-pole, 2-pole, 3-pole, and 4-pole configurations from Rs. 450 to Rs. 3,400.\u003c\/p\u003e\n\u003cp\u003eEvery CNC breaker carries IEC 60898-1 (AC) or IEC 60898-2 (DC) compliance, 6 kA short-circuit rating, B-curve (residential) or C-curve (motor \/ inductive) trip characteristics, and a 5-year warranty. Stocked locally in Lahore with same-day dispatch nationwide.\u003c\/p\u003e\n\n\u003ch2\u003eCNC Circuit Breaker (MCB) Price Table — Pakistan 2026\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;margin:14px 0;font-size:14px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eType\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003ePoles\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eAmperage Range\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eUse Case\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003ePrice (PKR)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eYCB7-63 1P (2A-63A)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eAC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e1 Pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e2-63 A (9 variants)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eSub-circuit, lights, sockets\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eRs. 450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eYCB7-63 1P+N (10A-40A)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eAC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e1P + Neutral\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e10-40 A (4 variants)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eCompact bathroom \/ kitchen\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eRs. 850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eYCB7-63 2P (10A-63A)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eAC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e2 Pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e10-63 A (7 variants)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eHome \/ shop sub-main, AC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eRs. 900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eYCB7-63 3P (20A-63A)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eAC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e3 Pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e20-63 A (5 variants)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e3-phase motor, factory\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eRs. 1,350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eYCB7-63 4P (20A-63A)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eAC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e4 Pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e20-63 A (4 variants)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e3-phase + neutral switching\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eRs. 1,900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eYCB7H 1P 100A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eAC High-Current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e1 Pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e100 A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eSub-main on larger homes\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eRs. 1,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eYCB8s-63PV 2P 500V\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eDC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e2 Pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e10-63 A (4 variants)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eSolar PV string protection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eRs. 1,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eYCB8s-63PV 4P 1000V\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eDC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e4 Pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e10-63 A (3 variants)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eHigher-voltage solar arrays\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eRs. 3,400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eYCB1-125 1P 500V 125A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eDC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e1 Pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e125 A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eSolar combiner \/ inverter input\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eRs. 1,150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eYCB1-125 2P 500V 125A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eDC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e2 Pole\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e125 A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eBattery bank disconnect\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eRs. 2,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFree delivery across Pakistan. 5-year warranty. Bulk \u0026amp; dealer pricing — \u003ca href=\"https:\/\/wa.me\/923261111376\"\u003eWhatsApp +92 326 1111376\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eMCB Full Form \u0026amp; What an MCB Actually Does\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMCB stands for Miniature Circuit Breaker.\u003c\/strong\u003e It is the standard small DIN-rail-mount breaker found in every modern distribution board (DB box) in Pakistan. The \"miniature\" refers to physical size — 18 mm wide per pole — distinguishing it from the larger Moulded-Case Circuit Breaker (MCCB) used for higher currents and the Air Circuit Breaker (ACB) used for main panel duty.\u003c\/p\u003e\n\u003cp\u003eAn MCB performs two protection functions in one device:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload protection (thermal):\u003c\/strong\u003e A bimetallic strip heats up as current rises. After a defined time delay (seconds to minutes depending on overload), the strip bends and trips the breaker. Calibrated to allow short inrush currents (motor starting) but trip on sustained overload.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit protection (magnetic):\u003c\/strong\u003e A solenoid coil instantly trips the breaker when current spikes above 5-10× rated value. Response time is sub-millisecond — fast enough to interrupt before cable insulation fails.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhat an MCB does \u003cstrong\u003enot\u003c\/strong\u003e protect against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEarth leakage \/ electric shock — that needs an \u003ca href=\"\/collections\/rccb\"\u003eRCCB or RCBO\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eLightning surges — that needs an \u003ca href=\"\/collections\/spd\"\u003eSPD\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eUnder-voltage \/ over-voltage — that needs a \u003ca href=\"\/collections\/voltage-protectors\"\u003evoltage protector\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower outages or load shifting — that needs a \u003ca href=\"\/collections\/changeovers\"\u003echangeover switch\u003c\/a\u003e or \u003ca href=\"\/collections\/ats\"\u003eATS\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA complete distribution board uses 4-6 different protection devices, each addressing one threat. MCBs handle the most common (overload + short-circuit) and are always present.\u003c\/p\u003e\n\n\u003ch2\u003eMCB vs MCCB vs RCCB vs ACB — Complete Comparison\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;margin:14px 0;font-size:14px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eDevice\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eFull Form\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eAmperage Range\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eShort-Circuit Rating\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eAdjustable Trip?\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eUsed For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e\u003cstrong\u003eMCB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eMiniature Circuit Breaker\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e0.5-125 A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e3-10 kA\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eNo (fixed curve)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eHome \/ shop sub-circuits, lighting, sockets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eMCCB\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eMoulded Case Circuit Breaker\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e16-2500 A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e25-70 kA\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eYes (adjustable thermal + magnetic)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eFactory main, large industrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eRCCB \/ RCBO\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eResidual Current Circuit Breaker (with Overload)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e10-100 A @ 30 mA\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e3-10 kA\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eSensitivity selectable\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eEarth-leakage protection (bathrooms, kitchens)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eACB\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eAir Circuit Breaker\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e630-6300 A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e50-150 kA\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eYes (electronic trip unit)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eSubstation main, large factories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eMost Pakistani homes need \u003cstrong\u003eMCBs\u003c\/strong\u003e for sub-circuits + one \u003cstrong\u003eRCBO\u003c\/strong\u003e for earth-leakage protection. Shops typically add an \u003cstrong\u003eMCCB\u003c\/strong\u003e at the main DB. Factories use an \u003cstrong\u003eACB\u003c\/strong\u003e at the substation. See our deep-dive: \u003ca href=\"\/blogs\/guides\/mccb-breaker-price-in-pakistan-2026-buying-guide\"\u003eMCCB Breaker Price in Pakistan 2026 — MCB vs MCCB vs RCCB Buyer's Guide\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eHow an MCB Works — The Mechanism Inside\u003c\/h2\u003e\n\u003cp\u003eLift the cover of any CNC MCB and you see four key components on a DIN-rail-compatible body:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBimetallic strip\u003c\/strong\u003e — bends when heated by overload current. Calibrated to the breaker's rated amperage. Slow response (seconds to minutes).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolenoid coil\u003c\/strong\u003e — pulls a plunger when current spikes above 5-10× rated. Instant response (sub-millisecond).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc-extinguishing chamber\u003c\/strong\u003e — a series of metal plates that split the arc into many small arcs that self-extinguish at zero-crossing. The 6 kA short-circuit rating is determined by this chamber.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip-free mechanism\u003c\/strong\u003e — even if you hold the toggle in the ON position, the breaker will still trip on fault. This is a code requirement to prevent override-induced fires.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe bimetallic + solenoid combination gives \"inverse-time-overcurrent\" tripping — the heavier the overload, the faster the trip. A 10× overload trips in milliseconds; a 1.5× overload may take 10 minutes. This is by design — it allows motor inrush currents (which last 100-200 ms at 5-7× nominal) to pass without nuisance tripping.\u003c\/p\u003e\n\n\u003ch2\u003eB-Curve vs C-Curve vs D-Curve — Which One Do You Need?\u003c\/h2\u003e\n\u003cp\u003eMCB trip curves describe the magnetic-trip threshold (instant short-circuit response):\u003c\/p\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;margin:14px 0;font-size:14px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eCurve\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eMagnetic Trip Range\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e\u003cstrong\u003eB-Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e3-5× rated current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eResidential — lights, sockets, resistive loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e\u003cstrong\u003eC-Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e5-10× rated current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eCommercial \/ mixed — small motors, fluorescent lighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e\u003cstrong\u003eD-Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e10-20× rated current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eIndustrial \/ motor — high inrush transformers, large motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eK-Curve\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e8-12× rated current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eHeavy motor loads (sometimes used instead of D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor Pakistani home use, \u003cstrong\u003eC-curve is the practical default\u003c\/strong\u003e — it tolerates AC compressor inrush while still tripping fast on real faults. CNC YCB7-63 series ships as C-curve by default. Specify B-curve only for pure resistive circuits (lighting-only sub-circuits in offices).\u003c\/p\u003e\n\n\u003ch2\u003eChoosing the Right Amperage — Sizing Matrix\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;margin:14px 0;font-size:14px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eCircuit\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eTypical Load\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eRecommended MCB\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eCable Size\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eLighting sub-circuit (LED)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e0.5-2 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e6 A or 10 A (B-curve)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e1.5 mm² copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eBedroom sockets\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e1-3 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e16 A (C-curve)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e2.5 mm² copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eKitchen sockets\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e3-6 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e20 A (C-curve)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e2.5 mm² copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eAir conditioner (1-1.5 ton)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e1.5-2.5 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e20-25 A (C-curve)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e2.5 mm² copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eAir conditioner (2-3 ton)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e3-5 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e32-40 A (C-curve)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e4 mm² copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eGeyser \/ water heater\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e3-9 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e20-40 A (C-curve)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e2.5-4 mm² copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eSingle-phase home main\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e8-14 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e63 A (C-curve)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e10-16 mm² copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e3-phase home \/ shop main\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e15-25 kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e63 A 4P (C-curve)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e10-16 mm² copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eFactory feeder\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e30+ kW\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eMCCB 100A+\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e25 mm²+ copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eRule of thumb: MCB rating ≥ (load kW × 1000) \/ 220 \/ 0.8. The 0.8 power factor margin keeps the breaker below its thermal trip threshold under sustained load.\u003c\/p\u003e\n\n\u003ch2\u003eAC vs DC Circuit Breakers — Are They Interchangeable?\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eNo — never substitute one for the other.\u003c\/strong\u003e AC and DC breakers use the same toggle mechanism but very different arc-extinguishing designs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC breakers\u003c\/strong\u003e rely on the 100-time-per-second zero-crossing of the AC waveform to extinguish the arc. The breaker just needs to interrupt at the right moment — physics does the rest.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC breakers\u003c\/strong\u003e have no zero-crossing — the current is constant. They need a much stronger magnetic blow-out coil and larger arc-extinguishing chamber to forcibly extend and cool the arc until it self-extinguishes. Putting AC breakers on DC circuits will not interrupt a short-circuit fault — the arc will continue burning until the wire melts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways specify DC-rated breakers for solar PV strings, battery banks, electric-vehicle charging, and any DC industrial supply. CNC offers the YCB8s-63PV (DC PV) and YCB1-125 (DC battery) series — see \u003ca href=\"\/collections\/dc-breaker\"\u003eCNC DC Circuit Breakers\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eBrowse CNC Circuit Breakers by Type\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/ac-mccb-breakers\"\u003eAC MCCB Breakers\u003c\/a\u003e — moulded-case for high-current main panels\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/dc-breaker\"\u003eDC Breakers\u003c\/a\u003e — for solar PV strings and battery systems\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/wifi-smart-circuit-breakers\"\u003eWiFi Smart Circuit Breakers\u003c\/a\u003e — Tuya app + remote control\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/acb-breakers\"\u003eACB (Air Circuit Breakers)\u003c\/a\u003e — substation main, large industrial\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/rccb\"\u003eRCCB \/ RCBO\u003c\/a\u003e — earth-leakage \/ shock protection\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/changeovers\"\u003eChangeover Breakers\u003c\/a\u003e — mains \/ generator transfer\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/ats\"\u003eATS — Automatic Transfer Switches\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTop Picks by Use Case\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBest Value Sub-Circuit MCB: YCB7-63 1P 16A or 32A.\u003c\/strong\u003e Rs. 450 — covers lighting, bedroom sockets, kitchen sockets. 9 amperage variants from 2 A to 63 A. \u003ca href=\"\/products\/cnc-1-pole-mcb-ac-breaker-ycb7-63a\"\u003eView product →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest for AC Circuit: YCB7-63 2P 32A.\u003c\/strong\u003e Rs. 900 — switches live + neutral, ideal for AC, fridge, geyser. 7 amperage variants. \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\"\u003eView product →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest for Main Incomer (single-phase): YCB7H 1P 100A.\u003c\/strong\u003e Rs. 1,200 — handles full home load up to 22 kW. \u003ca href=\"\/products\/cnc-ac-1-pole-mcb-100a-circuit-breaker\"\u003eView product →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest for 3-Phase Commercial: YCB7-63 4P 63A.\u003c\/strong\u003e Rs. 1,900 — full 4-pole switching for 3-phase + neutral installations. \u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\"\u003eView product →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest for Solar PV (500V): YCB8s-63PV 2P 500V.\u003c\/strong\u003e Rs. 1,600 — DC-rated for solar strings up to 500 V open-circuit. \u003ca href=\"\/products\/cnc-2-pole-mcb-dc-circuit-breakers-500v-ycb8-63pv\"\u003eView product →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest for Solar PV (1000V): YCB8s 4P 1000V.\u003c\/strong\u003e Rs. 3,400 — 1000 V DC rated for higher-voltage solar arrays. \u003ca href=\"\/products\/cnc-4-pole-mcb-dc-circuit-breakers-1000v-ycb8-63pv\"\u003eView product →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest for Battery \/ EV \/ High DC: YCB1-125 2P 500V 125A.\u003c\/strong\u003e Rs. 2,500 — heavy-duty DC for battery banks, EV chargers, large solar combiners. \u003ca href=\"\/products\/cnc-dc-2p-circuit-battery-breakers-500v-125a-ycb1-125-high-voltage\"\u003eView product →\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eCNC vs Schneider vs Chint vs Clopal — MCB Brand Comparison\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;margin:14px 0;font-size:14px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eBrand\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eOrigin\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eWarranty\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eShort-Circuit Rating\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003eDC Variant\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:10px;text-align:left;background:#f5f5f5\"\u003ePrice for 32 A 1P\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e\u003cstrong\u003eCNC YCB7-63\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eImported, Lahore-stocked\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e5 years\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e6 kA\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eYes (YCB8\/YCB1)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eRs. 450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eSchneider Acti9\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eEuropean premium\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e3 years\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e10 kA\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eRs. 2,400 – 3,800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eChint NXB-63\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eImported (China)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e2 years\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e6 kA\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eRs. 700 – 1,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eABB SH200\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eEuropean premium\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e2 years\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e10 kA\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eLimited\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eRs. 2,800 – 4,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eClopal\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eLocal brand\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e1 year\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003e4.5 kA\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px\"\u003eRs. 350 – 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eAqua\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eLocal brand\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e1 year\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003e4.5 kA\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:10px;background:#fafafa\"\u003eRs. 300 – 450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eCNC offers the longest warranty (5 years) in the imported-quality tier with full IEC 60898-1 compliance. Local brands (Clopal, Aqua) are cheaper at Rs. 300-500 but ship with 4.5 kA short-circuit rating and 1-year warranty — adequate for residential lighting but undersized for AC and 3-phase loads.\u003c\/p\u003e\n\n\u003ch2\u003eWhere to Install Your MCB\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDistribution board (DB box):\u003c\/strong\u003e Standard placement. Each sub-circuit gets its own MCB on the DIN rail downstream of the main breaker. Group lighting MCBs (B-curve) separately from socket \/ motor MCBs (C-curve) for easier troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSub-DB for additions:\u003c\/strong\u003e When adding a kitchen extension, garage, or outbuilding, install a sub-DB with its own incoming MCB (typically 32 A or 63 A) plus individual MCBs for new circuits. This keeps the main DB box uncluttered and isolates faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar inverter \/ PV system:\u003c\/strong\u003e Use DC-rated MCBs on the PV string side (between solar panels and inverter), and AC-rated MCBs on the AC output side (between inverter and home distribution). Never mix AC and DC breakers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEV charging:\u003c\/strong\u003e Dedicated 32 A or 40 A MCB (C-curve) on the charger's incoming circuit. Pair with an RCBO for fault-current protection during charging.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Testing\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eSwitch OFF the upstream breaker (main MCB or service disconnect) before any installation work.\u003c\/li\u003e\n\u003cli\u003eClip the new MCB onto the DIN rail — push down and snap forward until it clicks.\u003c\/li\u003e\n\u003cli\u003eConnect the live wire to the top terminal (input). Connect the load-side live wire to the bottom terminal (output). Tighten terminal screws to 2.5 Nm — undertorque causes overheating, overtorque cracks the housing.\u003c\/li\u003e\n\u003cli\u003eRoute the neutral wire to the neutral bar in the DB (not through the MCB unless it is a 1P+N or 2P type).\u003c\/li\u003e\n\u003cli\u003eRestore upstream power. Verify the new circuit works under load.\u003c\/li\u003e\n\u003cli\u003eTest the breaker monthly by switching it OFF manually and confirming the downstream circuit is dead.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor new installations, all MCBs should be load-tested by a qualified electrician to verify trip times match the manufacturer's data sheet. CNC MCBs ship with calibration test reports for orders of 50+ units.\u003c\/p\u003e\n\n\u003ch2\u003eBulk \u0026amp; Dealer Pricing\u003c\/h2\u003e\n\u003cp\u003eCNC YCB-series MCBs are stocked in volume in Lahore with same-day dispatch nationwide. Bulk pricing for panel manufacturers, electrical contractors, and solar installers. Solar installer bundles (DC MCB + SPD + voltage protector + RCBO) priced together for full-system protection. WhatsApp \u003ca href=\"https:\/\/wa.me\/923261111376\"\u003e+92 326 1111376\u003c\/a\u003e with your project requirement.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003ch2 id=\"faq\"\u003eFrequently Asked Questions — Circuit Breaker \/ MCB Pakistan\u003c\/h2\u003e\n\u003cdiv class=\"collection-faq\"\u003e\n\n\u003ch3\u003eWhat is the full form of MCB?\u003c\/h3\u003e\n\u003cp\u003eMCB stands for \u003cstrong\u003eMiniature Circuit Breaker\u003c\/strong\u003e. It is the standard small DIN-rail-mount breaker found in every modern distribution board in Pakistan. \"Miniature\" refers to its physical size (18 mm wide per pole), distinguishing it from larger MCCBs and ACBs used for higher currents.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the price of an MCB breaker in Pakistan?\u003c\/h3\u003e\n\u003cp\u003eCNC MCBs start at Rs. 450 for a single-pole AC breaker (YCB7-63 1P, 2-63 A range) and go up to Rs. 3,400 for a 4-pole 1000 V DC solar breaker (YCB8s-63PV 4P). Most home use cases fall in the Rs. 450-900 range. Local brands (Clopal, Aqua) start from Rs. 300; imported premium (Schneider, ABB) goes Rs. 2,400+ for the same rating.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the difference between MCB and MCCB?\u003c\/h3\u003e\n\u003cp\u003eAn MCB (Miniature Circuit Breaker) is for low-current circuits — 0.5 to 125 A, with 3-10 kA short-circuit rating. An MCCB (Moulded Case Circuit Breaker) handles higher currents — 16 to 2500 A, with 25-70 kA short-circuit rating. MCCBs also have adjustable trip settings (thermal and magnetic), while MCBs have fixed factory-set trip curves. Use MCBs for home \/ shop sub-circuits; use MCCBs for main panels and factory feeders.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the difference between an AC and a DC circuit breaker?\u003c\/h3\u003e\n\u003cp\u003eAC breakers rely on the natural zero-crossing of the AC waveform (100 times per second) to extinguish the internal arc. DC has no zero-crossing — current is constant — so DC breakers need a much stronger magnetic blow-out coil and larger arc-extinguishing chamber to force the arc to cool and self-extinguish. \u003cstrong\u003eNever substitute one for the other.\u003c\/strong\u003e AC breakers on DC circuits will not interrupt short-circuit faults safely.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the difference between B, C, and D curve MCBs?\u003c\/h3\u003e\n\u003cp\u003eMCB trip curves describe the magnetic-trip (instant short-circuit) threshold. B-curve trips at 3-5× rated current (residential lighting). C-curve trips at 5-10× rated current (commercial, small motors — the default for Pakistani home use). D-curve trips at 10-20× rated current (heavy industrial, large motor inrush). C-curve is the practical default for almost all Pakistani residential and shop applications.\u003c\/p\u003e\n\n\u003ch3\u003eHow do I choose the right amperage for an MCB?\u003c\/h3\u003e\n\u003cp\u003eMatch the MCB rating to the connected load divided by 220 V × 0.8 power factor. For lighting use 6-10 A; bedroom sockets 16 A; kitchen sockets 20 A; 1.5-ton AC 20-25 A; 2-3 ton AC 32-40 A; geyser 20-40 A; home main (8-14 kW) 63 A. Always pair with the correct cable size (1.5 mm² for 6-10 A, 2.5 mm² for 16-25 A, 4 mm² for 32-40 A, 10-16 mm² for 63 A main).\u003c\/p\u003e\n\n\u003ch3\u003eCan I use an MCB for solar?\u003c\/h3\u003e\n\u003cp\u003eOnly the DC-rated MCB variants. CNC offers the YCB8s-63PV (500 V or 1000 V DC, for solar PV strings) and the YCB1-125 (heavy DC, for battery banks). Standard AC MCBs will not interrupt DC short-circuit faults — they must never be used on the DC side of a solar installation.\u003c\/p\u003e\n\n\u003ch3\u003eDo MCBs require maintenance?\u003c\/h3\u003e\n\u003cp\u003eMCBs are mostly maintenance-free. Recommended: monthly visual inspection for discoloration or scorching around terminals (signs of loose connections heating up); annual torque-check of terminal screws to 2.5 Nm; functional test by toggling OFF\/ON every 12 months to keep the mechanism free. Industrial breakers in dusty environments may need vacuum-cleaning of the enclosure every 6 months.\u003c\/p\u003e\n\n\u003ch3\u003eWhy does my MCB keep tripping?\u003c\/h3\u003e\n\u003cp\u003eCommon causes: (1) genuine overload — too many appliances on one circuit, fix by splitting circuits or upgrading the breaker (if cabling allows); (2) short-circuit in a damaged appliance or wire — disconnect one device at a time to identify; (3) faulty MCB itself — replace if it trips with no load; (4) wrong trip curve — B-curve on a circuit with motor loads will nuisance-trip on inrush, swap to C-curve.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the lifespan of an MCB?\u003c\/h3\u003e\n\u003cp\u003eMechanical life: 10,000-20,000 operations (each ON\/OFF cycle). Electrical life: 4,000-10,000 trip events under fault conditions. For typical home use (occasional manual switching, rare trips), CNC MCBs last 15-25 years. CNC ships with a 5-year warranty covering manufacturing defects.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- CNC-PILLAR-FOOTER --\u003e\n\u003ch2\u003eMore CNC Electric Buyer's Guides\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/mccb-breaker-price-in-pakistan-2026-buying-guide\"\u003eMCCB Breaker Price in Pakistan 2026 — MCB vs MCCB vs RCCB Buyer's Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/voltage-protector-vs-stabilizer-which-one-does-your-home-actually-need\"\u003eVoltage Protector vs Stabilizer 2026 — Which One Does Your Home Actually Need\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/spd-full-form-what-is-surge-protection-device-why-pakistan-needs-it\"\u003eSPD Price in Pakistan 2026 — Surge Protection Device Buyer's Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/electricity-meter-price-in-pakistan-2026-digital-smart-3-phase-meter-buyers-guide-cnc-electric\"\u003eElectricity Meter Price in Pakistan 2026 — Digital, Smart \u0026amp; 3-Phase Buyer's Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/contactor-price-in-pakistan-2026-magnetic-contactor-buyers-guide-12a-265a-cjx2s-cnc-electric\"\u003eMagnetic Contactor Price in Pakistan 2026 — 12A-265A CJX2s Buyer's Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/fire-extinguisher-price-in-pakistan-2026-types-sizes-buyers-guide-abc-co2-aerosol-cnc-electric\"\u003eFire Extinguisher Price in Pakistan 2026 — ABC, CO2, Aerosol Buyer's Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/net-metering-pakistan-2026-nepra-regulations-guide\"\u003eNet Metering Pakistan 2026 — Cost, NEPRA Rules \u0026amp; Solar Protection\u003c\/a\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/dc-breaker-price-in-pakistan-2026-solar-battery-buyers-guide\"\u003eDC Breaker Price in Pakistan 2026 — Solar \u0026amp; Battery Buyer's Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/solar-dc-cable-price-in-pakistan-2026-4mm-6mm-buyers-guide\"\u003eSolar DC Cable Price in Pakistan 2026 — 4mm \u0026amp; 6mm Buyer's Guide\u003c\/a\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/how-to-choose-voltage-protector-va-protector-pakistan-2026-selection-guide\"\u003eHow to Choose a Voltage Protector \/ VA Protector — Selection Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/how-to-wire-spd-with-fuse-mcb-rccb-fire-safe-surge-protection-pakistan\"\u003eHow to Wire SPD with Fuse + MCB + RCCB — Fire-Safe Surge Protection\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/1500v-industrial-solar-installation-pakistan-dc-breaker-spd-fuse-mccb-sizing\"\u003e1500V Industrial Solar Installation — DC Breaker, SPD, MCCB Sizing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/mccb-acb-industrial-pakistan-factory-switchgear-buyers-guide-2026\"\u003eMCCB \u0026amp; ACB for Industrial Pakistan — Factory Switchgear\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/mcb-wiring-installation-guide-pakistan-db-box-layout-torque-coordination\"\u003eMCB Wiring \u0026amp; Installation Guide — DB Box Layout, Torque\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/ac-breaker-for-air-conditioner-pakistan-size-cable-tripping-fixes-1-1-5-2-3-ton\"\u003eAC Breaker for Air Conditioner — 1, 1.5, 2, 3 Ton Sizing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/solar-combiner-box-wiring-pakistan-dc-breaker-fuse-spd-step-by-step-installation\"\u003eSolar Combiner Box Wiring — DC Breaker, Fuse, SPD Step-by-Step\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/ev-charger-pakistan-2026-home-commercial-buyers-guide-protection-chain-cable-sizing\"\u003eEV Charger Pakistan 2026 — Home \u0026amp; Commercial Buyer's Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/cnc-industrial-range-pakistan-factory-switchgear-mccb-contactor-ats-acb-roadmap-2026\"\u003eCNC Industrial Range — Complete Factory Switchgear Roadmap\u003c\/a\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/battery-bank-pakistan-lfp-vs-lead-acid-solar-battery-buyers-guide-2026\"\u003eBattery Bank Pakistan — LFP vs Lead-Acid Solar Battery Buyer's Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/solar-inverter-pakistan-hybrid-grid-tie-off-grid-selection-guide-2026\"\u003eSolar Inverter Pakistan — Hybrid, Grid-Tie, Off-Grid Selection\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/mc4-connectors-pakistan-branded-vs-generic-crimping-failure-modes-2026\"\u003eMC4 Connectors Pakistan — Branded vs Generic, Crimping Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/pv-string-sizing-pakistan-voc-temperature-derating-inverter-compatibility-2026\"\u003ePV String Sizing — Voc, Temperature Derating, Inverter Compatibility\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/dc-fuse-vs-dc-breaker-pakistan-solar-strings-batteries-spd-protection-2026\"\u003eDC Fuse vs DC Breaker — Solar Strings, Batteries \u0026amp; SPD\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/off-grid-solar-system-design-pakistan-complete-sizing-protection-guide-2026\"\u003eOff-Grid Solar System Design Pakistan — Complete Sizing Guide\u003c\/a\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/why-ac-breaker-cannot-be-used-on-solar-system-physics-risks-replacement-pakistan-2026\"\u003eWhy AC Breaker CANNOT Be Used on Solar — Physics \u0026amp; Risks\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/cnc-1500v-dc-solar-protection-bom-100kw-500kw-1mw-5mw-pakistan-2026\"\u003eCNC 1500V DC Solar Protection BOM — 100kW to 5MW\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/5-spd-fire-case-studies-pakistan-root-cause-analysis-prevention-2026\"\u003e5 SPD Fire Case Studies Pakistan — Root Cause Analysis\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\"@type\":\"Question\",\"name\":\"What is the full form of MCB?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"MCB stands for Miniature Circuit Breaker. It is the standard small DIN-rail-mount breaker in every modern distribution board. The 'miniature' refers to physical size — 18 mm wide per pole — distinguishing it from larger MCCBs and ACBs used for higher currents.\"}},\n    {\"@type\":\"Question\",\"name\":\"What is the price of an MCB breaker in Pakistan?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"CNC MCBs start at Rs. 450 for a single-pole AC breaker (2-63 A range) and go up to Rs. 3,400 for a 4-pole 1000 V DC solar breaker. Most home use cases fall in Rs. 450-900. Local brands start Rs. 300; imported premium Schneider\/ABB Rs. 2,400+ for same rating.\"}},\n    {\"@type\":\"Question\",\"name\":\"What is the difference between MCB and MCCB?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"An MCB is for low-current circuits — 0.5 to 125 A, with 3-10 kA short-circuit rating. An MCCB handles higher currents — 16 to 2500 A, with 25-70 kA short-circuit rating and adjustable trip settings. Use MCBs for home\/shop sub-circuits; use MCCBs for main panels and factory feeders.\"}},\n    {\"@type\":\"Question\",\"name\":\"What is the difference between an AC and DC circuit breaker?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"AC breakers rely on the natural zero-crossing of the AC waveform to extinguish the internal arc. DC has no zero-crossing, so DC breakers need a much stronger magnetic blow-out coil and larger arc-extinguishing chamber. Never substitute one for the other — AC breakers on DC circuits will not interrupt short-circuit faults safely.\"}},\n    {\"@type\":\"Question\",\"name\":\"What is the difference between B, C, and D curve MCBs?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"B-curve trips at 3-5× rated current (residential lighting). C-curve trips at 5-10× rated current (commercial, small motors — the default for Pakistani home use). D-curve trips at 10-20× rated current (heavy industrial). C-curve is the practical default for almost all residential and shop applications.\"}},\n    {\"@type\":\"Question\",\"name\":\"How do I choose the right amperage for an MCB?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Match the MCB rating to load (kW × 1000) \/ 220V \/ 0.8 power factor. For lighting use 6-10 A; bedroom sockets 16 A; kitchen sockets 20 A; 1.5-ton AC 20-25 A; 2-3 ton AC 32-40 A; geyser 20-40 A; home main 63 A. Always pair with the correct cable size.\"}},\n    {\"@type\":\"Question\",\"name\":\"Can I use an MCB for solar?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Only DC-rated variants. CNC offers YCB8s-63PV (500 V or 1000 V DC for solar PV strings) and YCB1-125 (heavy DC for battery banks). Standard AC MCBs will not interrupt DC short-circuit faults and must never be used on the DC side of a solar installation.\"}},\n    {\"@type\":\"Question\",\"name\":\"Do MCBs require maintenance?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"MCBs are mostly maintenance-free. Recommended: monthly visual inspection for discoloration around terminals; annual torque-check of terminal screws to 2.5 Nm; functional test by toggling OFF\/ON every 12 months. Industrial breakers in dusty environments need vacuum-cleaning every 6 months.\"}},\n    {\"@type\":\"Question\",\"name\":\"Why does my MCB keep tripping?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Common causes: genuine overload (too many appliances), short-circuit in a damaged appliance, faulty MCB itself (replace if trips with no load), or wrong trip curve (B-curve on motor loads nuisance-trips on inrush — swap to C-curve). Disconnect devices one at a time to identify the source.\"}},\n    {\"@type\":\"Question\",\"name\":\"What is the lifespan of an MCB?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Mechanical life: 10,000-20,000 operations. Electrical life: 4,000-10,000 fault-trip events. For typical home use (occasional switching, rare trips), CNC MCBs last 15-25 years. CNC ships with 5-year warranty covering manufacturing defects.\"}}\n  ]\n}\n\u003c\/script\u003e\n\u003c!-- Round 5 ranking-gap fix 2026-05-29: keyword-rich body to compete with alladin.pk --\u003e\n\u003cdiv style=\"max-width:900px;margin:24px auto;padding:22px 20px;font-family:system-ui,sans-serif;font-size:15px;line-height:1.65;color:#333;\"\u003e\n\n\u003ch2 style=\"font-size:22px;color:#d42027;border-bottom:2px solid #d42027;padding-bottom:8px;\"\u003eAC \u0026amp; DC Circuit Breaker Price in Pakistan 2026 — Complete Range\u003c\/h2\u003e\n\n\u003cp style=\"font-size:16px;\"\u003eCNC Electric is Pakistan's authorised stockist of CNC Electric switchgear. We carry the complete range of \u003cstrong\u003eAC circuit breakers\u003c\/strong\u003e (MCB, MCCB, RCCB, ACB) and \u003cstrong\u003eDC circuit breakers\u003c\/strong\u003e (solar PV breakers, battery breakers, EV charger breakers) — all certified to IEC 60898 \/ IEC 60947-2 and backed by 5-year warranty from local Lahore stock.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:18px;color:#222;margin-top:24px;\"\u003eAC Breakers — Standard Residential \u0026amp; Commercial\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:14px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003ePrice (PKR)\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eUse\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eAC MCB 1P\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e2A-63A 230V 6kA\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRs. 450-680\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eLighting, single-phase home circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eAC MCB 2P\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10A-63A 230V 6kA\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRs. 900-1,400\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eGeyser, AC, sub-DB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eAC MCB 3P\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e20A-63A 400V 6kA\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRs. 1,350-2,100\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e3-phase motor, factory main\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eAC MCB 4P\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e20A-63A 400V 6kA\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRs. 1,900-2,600\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e3-phase + neutral, building main\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eAC MCCB 3P\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e63A-630A 35-65kA\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRs. 4,400-62,000\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eIndustrial mains, generator output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRCCB 2P\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e25A-63A 30mA\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRs. 2,200-3,400\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eBathroom, kitchen earth-leak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRCBO 1P+N\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e16A-63A 30mA\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRs. 1,800-2,800\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eCombined RCCB+MCB single module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eWiFi smart breaker\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e32A-100A 1P\/2P\/4P\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRs. 5,400-12,500\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eTuya app, scheduling, monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"font-size:18px;color:#222;margin-top:24px;\"\u003eDC Breakers — Solar PV, Battery, EV\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:14px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eVoltage\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003ePrice (PKR)\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eUse\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eDC MCB 1P 500V\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e125A YCB1\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRs. 1,150-1,400\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e12-48V battery feeder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eDC MCB 2P 500V Solar PV\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e20A-63A YCB8\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRs. 1,600-1,950\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSingle 6-12 panel solar string\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eDC MCB 2P 500V Battery\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e125A YCB1\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRs. 2,500-2,800\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eInverter battery bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eDC MCB 4P 1000V Solar\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e20A-63A\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRs. 3,400-3,700\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eStandard 600-800V residential PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eDC MCB 4P 1500V Solar\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e32A YCB8s\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eRs. 3,800-4,220\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eCommercial 1100-1300V PV plant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"font-size:18px;color:#222;margin-top:24px;\"\u003eWhy CNC Beats Imported \u0026amp; Mixed-Brand Stores\u003c\/h3\u003e\n\u003cul style=\"padding-left:24px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle trusted brand\u003c\/strong\u003e: every breaker is genuine CNC Electric, manufactured to IEC 60898 \/ IEC 60947-2 at the same factory that supplies industrial OEMs across Asia. No counterfeit risk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5-year warranty from local stock\u003c\/strong\u003e: faulty breakers replaced within 72 hours from Lahore, not 6-week RMA from China.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngineer-level technical support\u003c\/strong\u003e: WhatsApp +92-300-XXX-XXXX with sizing questions; our team has 20+ years of Pakistani electrical experience.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBulk pricing for installers\u003c\/strong\u003e: 50+ unit orders get 8-12% discount automatically.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar bundle pricing\u003c\/strong\u003e: pre-packaged DC breaker + SPD + isolator + DB box bundles save 15-20% vs buying separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"font-size:18px;color:#222;margin-top:24px;\"\u003eCompare With Other Pakistani Suppliers\u003c\/h3\u003e\n\u003cp\u003eWhen you compare CNC Electric vs alladin.pk, vs powerhouseexpress.com.pk, vs c-power.pk, vs industryparts.pk: CNC offers \u003cstrong\u003esingle-source brand certainty\u003c\/strong\u003e, the \u003cstrong\u003elongest factory warranty\u003c\/strong\u003e (5 years vs typical 1-2 years for mixed-brand resellers), and the \u003cstrong\u003edeepest technical literature\u003c\/strong\u003e (full IEC test reports + buying guides for every product family).\u003c\/p\u003e\n\n\u003cp style=\"margin-top:18px;font-size:16px;\"\u003e\u003cstrong\u003eIn-depth buying guides:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"padding-left:24px;\"\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/mcb-breaker-price-in-pakistan-2026-buying-guide\" style=\"color:#d42027;text-decoration:underline;\"\u003eMCB Breaker Price in Pakistan 2026\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/mccb-breaker-price-in-pakistan-2026-buying-guide\" style=\"color:#d42027;text-decoration:underline;\"\u003eMCCB Breaker Price in Pakistan 2026\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/dc-breaker-price-in-pakistan-2026-solar-battery-buyers-guide\" style=\"color:#d42027;text-decoration:underline;\"\u003eDC Breaker Price Pakistan 2026 — Solar \u0026amp; Battery\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/rccb-breaker-pakistan-2026-30ma-100ma-300ma-selection-wiring-guide\" style=\"color:#d42027;text-decoration:underline;\"\u003eRCCB 30mA \/ 100mA \/ 300mA Selection Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/breaker-switch-pakistan-complete-sizing-selection-guide-2026\" style=\"color:#d42027;text-decoration:underline;\"\u003eBreaker Switch Pakistan — 7 Types Compared\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Round 8.2 HowTo schema on cited collection (Brand Radar) 2026-05-30 --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"HowTo\",\n  \"name\": \"How to Choose the Right Circuit Breaker for Pakistani Electrical Installations\",\n  \"description\": \"Selection methodology to choose between MCB, MCCB, ACB, RCCB, and RCBO for different Pakistani electrical applications.\",\n  \"totalTime\": \"PT10M\",\n  \"author\": {\n    \"@type\": \"Person\",\n    \"name\": \"CNC Electric Pakistan Engineering Team\",\n    \"jobTitle\": \"Electrical Engineers\",\n    \"url\": \"https:\/\/cncelectric.pk\/pages\/our-engineers\"\n  },\n  \"publisher\": {\n    \"@type\": \"Organization\",\n    \"name\": \"CNC Electric Pakistan\",\n    \"logo\": {\n      \"@type\": \"ImageObject\",\n      \"url\": \"https:\/\/cncelectric.pk\/cdn\/shop\/files\/CNC-Electric-Pakistan-Logo-PNG-IN-WHITE-300X142.png\"\n    }\n  },\n  \"step\": [\n    {\n      \"@type\": \"HowToStep\",\n      \"position\": 1,\n      \"name\": \"Determine current range\",\n      \"text\": \"MCB for up to 125A circuits (residential and small commercial). MCCB for 16-1600A (commercial and industrial). ACB for 800-6300A (main switchgear, transformer secondaries, generator outputs).\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"position\": 2,\n      \"name\": \"Identify protection type needed\",\n      \"text\": \"Overcurrent only → MCB or MCCB. Overcurrent + earth leakage → RCBO (single device) or MCB + RCCB combination. Selective ground fault for switchgear → ACB with LSIG trip unit.\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"position\": 3,\n      \"name\": \"Check breaking capacity\",\n      \"text\": \"Residential PK supply: 6 kA MCB sufficient. Commercial\/industrial: 10-25 kA MCCB. Switchgear: 50-100 kA ACB. Calculate prospective short-circuit current at installation point using transformer impedance.\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"position\": 4,\n      \"name\": \"Select trip curve\",\n      \"text\": \"Curve B: resistive loads (lighting, heaters). Curve C: general purpose, mixed loads (default). Curve D: motor and inrush loads. Adjustable thermal\/magnetic for MCCB and ACB.\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"position\": 5,\n      \"name\": \"Match enclosure \u0026 mounting\",\n      \"text\": \"DIN-rail mount for MCB, smaller MCCB, and RCCB. Plug-in or fixed mounting for medium MCCB. Withdrawable cassette for ACB to allow maintenance without de-energizing busbar.\"\n    },\n    {\n      \"@type\": \"HowToStep\",\n      \"position\": 6,\n      \"name\": \"Verify standards \u0026 certification\",\n      \"text\": \"MCB: IEC 60898-1. MCCB and ACB: IEC 60947-2. RCCB: IEC 61008-1. Pakistani imports must comply with Pakistan Electrical Code and PBC 2016. Confirm 5-year warranty and Pakistan service network before purchase.\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\n\u003cp\u003e\u003c!-- orphan-link-injection-2026-06-04 --\u003e \u003cstrong\u003eSafety \u0026amp; resources:\u003c\/strong\u003e \u003ca href=\"\/pages\/electrical-panel-fire-safety-pakistan\"\u003eElectrical panel fire-safety guide (Pakistan)\u003c\/a\u003e · \u003ca href=\"\/collections\/ev-chargers\"\u003eEV chargers for Pakistani solar homes\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- faqpage-schema-2026-06-04 --\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"faq-block\"\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat is the price of a circuit breaker in Pakistan in 2026?\u003c\/h3\u003e\n\u003cp\u003eCNC MCB 1-pole starts at PKR 450, 2-pole at PKR 900, 4-pole MCB at PKR 1,900. MCCB from PKR 4,400, RCCB from PKR 2,200. DC solar 500V breakers from PKR 1,600.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhat is the difference between MCB, MCCB and RCCB?\u003c\/h3\u003e\n\u003cp\u003eMCB protects against overload and short-circuit up to 63A. MCCB handles 63A–630A with adjustable settings. RCCB protects against earth-leakage faults (30 mA) — does not protect against overload by itself.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eAre CNC circuit breakers IEC certified?\u003c\/h3\u003e\n\u003cp\u003eYes — CNC AC breakers are tested to IEC 60898-1 (MCB) and IEC 60947-2 (MCCB, DC). CNC DC solar breakers also carry PV-system polarity ratings.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eWhich breaker is best for a 1.5-ton AC unit in Pakistan?\u003c\/h3\u003e\n\u003cp\u003eA 1.5-ton AC draws ~6.5A continuous. Use a 16A or 20A C-curve MCB on a dedicated circuit, paired with an RCCB 30 mA on the consumer-unit feed for safety.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n\u003ch3\u003eDo CNC breakers come with warranty?\u003c\/h3\u003e\n\u003cp\u003eAll CNC AC and DC breakers ship with a 5-year warranty from cncelectric.pk. Free delivery on orders over PKR 5,000 anywhere in Pakistan.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"name\":\"Circuit Breakers Pakistan — FAQ\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the price of a circuit breaker in Pakistan in 2026?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"CNC MCB 1-pole starts at PKR 450, 2-pole at PKR 900, 4-pole MCB at PKR 1,900. MCCB from PKR 4,400, RCCB from PKR 2,200. DC solar 500V breakers from PKR 1,600.\"}},{\"@type\":\"Question\",\"name\":\"What is the difference between MCB, MCCB and RCCB?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"MCB protects against overload and short-circuit up to 63A. MCCB handles 63A–630A with adjustable settings. RCCB protects against earth-leakage faults (30 mA) — does not protect against overload by itself.\"}},{\"@type\":\"Question\",\"name\":\"Are CNC circuit breakers IEC certified?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — CNC AC breakers are tested to IEC 60898-1 (MCB) and IEC 60947-2 (MCCB, DC). CNC DC solar breakers also carry PV-system polarity ratings.\"}},{\"@type\":\"Question\",\"name\":\"Which breaker is best for a 1.5-ton AC unit in Pakistan?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A 1.5-ton AC draws ~6.5A continuous. Use a 16A or 20A C-curve MCB on a dedicated circuit, paired with an RCCB 30 mA on the consumer-unit feed for safety.\"}},{\"@type\":\"Question\",\"name\":\"Do CNC breakers come with warranty?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"All CNC AC and DC breakers ship with a 5-year warranty from cncelectric.pk. Free delivery on orders over PKR 5,000 anywhere in Pakistan.\"}}]}\u003c\/script\u003e","products":[{"product_id":"cnc-smart-wifi-breaker-single-pole-40a-ycsi","title":"WiFi Breaker 1 Pole 40A | Tuya Smart App | CNC YCSI","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eWiFi smart breaker 40A is the practical choice when you want to switch a single-phase circuit from your phone instead of walking to the DB every time. On the live CNC Electric Pakistan page, this single pole model is listed at Rs.5,400. It is built for remote ON\/OFF control, timing, real-time status feedback, metering, and leakage protection in a compact DIN-rail format. For homes, small offices, shops, water-pump lines, signboards, and controlled appliance circuits in Pakistan, that makes it a useful upgrade over an ordinary breaker.\u003c\/p\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe important thing is to buy it for the right job. This is not just a plain \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003ecircuit breaker\u003c\/a\u003e and it is not the same thing as a full \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;font-weight:700\"\u003evoltage protector\u003c\/a\u003e or a complete \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003esurge protection device\u003c\/a\u003e. It is a smart single-pole breaker for users who want remote switching, scheduling, status checking, and line monitoring in one modular device. If you are building a smarter board in Lahore, managing a pump line in Karachi, or controlling a shop circuit in Islamabad, that is the real use case.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eSingle-pole WiFi smart breaker with 40A local sale variant.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eRemote ON\/OFF control from phone or computer according to the live product description.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eReal-time product opening and closing feedback.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eTiming and delayed opening \/ closing functions.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eResidual current protection with stated fast disconnection behavior.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMetering function for voltage, current, power, and electricity according to the local page.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eDIN rail modular mounting for a proper board installation instead of loose smart modules.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eSuited to homes, offices, villas, shopping areas, schools, and similar single-phase control points.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProduct type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWiFi smart circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePole format\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSingle pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLocal sale variant\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated operating voltage family context\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAC 50Hz \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eModular DIN rail installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRemote control\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes, phone or computer remote opening \/ closing according to the local page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFeedback\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eReal-time ON\/OFF status feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTiming function\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTiming and delayed opening \/ closing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProtection functions stated on local page\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOverload, short circuit, leakage protection, metering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMeasured values stated on local page\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eVoltage, current, power, electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBreaking capacity, dimensions, exact app platform, threshold chart\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNot clearly published on the live local page and have not been guessed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis description uses only data published on the live local sale page plus limited official CNC smart-breaker family context where it clearly helps explain the product class. Exact short-circuit capacity, dimensions, detailed app screenshots, threshold menus, and terminal-size tables are not currently listed on the local page and have not been guessed.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range and Local Smart Breaker Context\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eProduct\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePoles\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eLocal visible variant\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCurrent local price\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYCSI smart breaker\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1P\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e40A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.5,400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e2-pole smart breaker\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e2P\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e63A on local site\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSee \u003ca href=\"\/collections\/wifi-smart-circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003eWiFi smart breakers\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e4-pole smart breaker\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e4P\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e100A class shown on local site\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSee \u003ca href=\"\/collections\/wifi-smart-circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003eWiFi smart breakers\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis single-pole model is the compact entry point into the smart-breaker range. Buy it when you want remote control of one phase line on a normal single-phase circuit. If you need phase and neutral isolation together, move up to a \u003ca href=\"\/collections\/wifi-smart-circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003e2-pole smart breaker\u003c\/a\u003e. If you are dealing with three-phase loads, step up to the 4-pole class instead of forcing a 1P device into the wrong job.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications in Pakistan\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis type of smart breaker is useful when the circuit is simple, single phase, and benefits from remote control. In Lahore apartments, that can mean a geyser circuit or rooftop water-pump line that the user wants to control on schedule. In Karachi shops and offices, it can be useful for sign lighting, selected socket lines, or controlled equipment that should not stay on after working hours. In Islamabad homes and offices, it suits users who want line monitoring and remote OFF capability on a specific branch without redesigning the whole board.\u003c\/p\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eApplication\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy it fits\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhat to watch\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGeyser control\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRemote ON\/OFF and timing reduce wasted run hours\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCheck actual load current and wiring condition first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSmall water pump line\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUseful when the user wants remote control and status feedback\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMotor starting behavior and wiring quality still matter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSignboard or selected lighting circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTiming and remote OFF are practical for shops and offices\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNot a substitute for proper surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eControlled appliance branch\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLets the user isolate and monitor a selected line\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eChoose 2P if you need phase and neutral cut together\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRental property \/ remote shutdown point\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGood where the owner wants remote visibility on one circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eInternet and control logic should be planned properly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Choose the Right Smart Breaker\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eYour requirement\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBest fit\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eReason\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSingle-phase branch, remote switching, 40A class\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThis 1P 40A model\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRight when you only need one line switched and monitored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed phase + neutral isolation\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e2-pole smart breaker\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBetter when full single-phase isolation is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThree-phase load or board\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e4-pole smart breaker\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA 1P unit is the wrong class for that job\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed protection against severe surge events\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAdd \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003eSPD\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSmart breaker metering is not the same as surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed over \/ under-voltage correction logic for supply instability\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAdd \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;font-weight:700\"\u003evoltage protector\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThat is a different product function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWiFi Smart Breaker vs Alternatives\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eOption\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhat it does well\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhere it falls short\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCNC WiFi smart breaker 1P 40A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRemote control, timing, feedback, leakage protection, metering, DIN rail form\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStill needs correct supporting protection around it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePlain MCB\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSimple and cheap branch protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNo remote control, no feedback, no scheduling, no metering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGeneric smart relay module\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLow entry cost for basic switching\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually weaker panel integration and less breaker-style functionality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e2-pole smart breaker\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBetter when phase and neutral both need switching\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBigger and not needed for every single-pole branch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product does not replace every other protection device in the board. It is not the same thing as a dedicated \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;font-weight:700\"\u003evoltage protector\u003c\/a\u003e, it does not replace a correctly selected \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003eSPD\u003c\/a\u003e for surge events, and it is not a substitute for a full \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;font-weight:700\"\u003eRCBO or RCCB solution\u003c\/a\u003e strategy where the board needs coordinated earth-leakage protection.\u003c\/p\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt also does not turn a badly designed circuit into a safe circuit. Loose terminations, undersized wiring, overloaded appliances, poor neutral management, and no surge protection will still create problems even if the breaker is smart. Buy it for remote switching and monitoring. Do not buy it expecting it to replace good board design.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n\u003col style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eConfirm that the branch circuit is a true single-phase application where a 1P smart breaker is the correct format.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount the unit properly on the DIN rail inside a suitable \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;font-weight:700\"\u003eDB box\u003c\/a\u003e or enclosure.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eTerminate the conductors cleanly and check the wiring condition before energizing the circuit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eConfigure remote control, timing, and user sharing only after basic local switching works correctly.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eIf the circuit is exposed to unstable mains or surge-prone conditions, add the proper \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;font-weight:700\"\u003evoltage protector\u003c\/a\u003e and \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003eSPD\u003c\/a\u003e rather than relying on the smart breaker alone.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n\u003cdiv style=\"margin-top:25px;padding:15px;background:#f9f9f9;border:1px solid #e0e0e0;border-radius:5px;\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin-bottom:10px;\"\u003eComplete Your Electrical Setup\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSurge Protection Devices (SPD)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🔌 \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003eVoltage Protectors\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📦 \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB Boxes\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🧠 \u003ca href=\"\/collections\/wifi-smart-circuit-breakers\" style=\"color:#d42027;\"\u003eWiFi Smart Breakers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚠️ \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO \u0026amp; RCCB\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📊 \u003ca href=\"\/collections\/energy-meters\" style=\"color:#d42027;\"\u003eEnergy Meters\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🔀 \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003eChangeover Breakers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🧰 \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027;\"\u003eAC Breakers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🧯 \u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;\"\u003eFire Extinguishers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📖 \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eGuide: Types of Circuit Breakers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📖 \u003ca href=\"\/blogs\/guides\/rccb-breaker-guide-pakistan-earth-leakage-protection\" style=\"color:#d42027;\"\u003eGuide: Safety Breaker\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:0;\"\u003e🧭 \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;\"\u003eVoltage Protector Finder Tool\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px\"\u003e⚡ \u003ca href=\"\/blogs\/news\/wifi-smart-breaker-vs-normal-breaker-pakistan-comparison\" style=\"color:#d42027\"\u003eWiFi Breaker vs Normal Breaker\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the price of this WiFi smart breaker in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eAt the time checked, the live CNC Electric Pakistan page listed the single-pole 40A WiFi smart breaker at Rs.5,400.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I control this breaker from my phone?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. The local page states that the breaker supports remote opening and closing by mobile phone app or computer, plus real-time status feedback.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this WiFi smart breaker show power usage?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe live product page says it has a metering function and can display voltage, current, power, and electricity values.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this better than a plain MCB?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt is better only if you actually need remote control, timing, feedback, and monitoring. If you only need a basic protective device, a plain breaker can still be the simpler answer.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I use this for my whole house?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eUsually no. This single-pole 40A model is better treated as a branch or selected-circuit smart breaker. Whole-house control needs a more careful board-level design and often a different pole format.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the difference between 1 pole and 2 pole smart breakers?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA 1P smart breaker is for a single line path. A 2P smart breaker is the better choice when phase and neutral both need switching or isolation together.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this replace a voltage protector or SPD?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. A smart breaker does not replace a proper voltage protector for unstable mains or an SPD for surge protection. Those are separate devices with different jobs.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan this be installed in a normal Pakistani DB box?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, the product class is built for modular DIN rail installation. It should still be installed in a suitable enclosure with proper wiring practice and the right surrounding protection devices.\u003c\/p\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis WiFi smart breaker 40A is a practical upgrade for users who want remote switching, scheduling, feedback, and circuit monitoring on a single-phase branch. It makes the most sense when the job is a selected line, not the whole installation. For stock checks, technical guidance, and product matching, contact CNC Electric Pakistan on WhatsApp 0326-1111376. Orders above Rs.10,000 qualify for free delivery across Pakistan.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"Single Pole \/ 40A","offer_id":42320934797378,"sku":"YCSI","price":6000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Wi-Fi_1_Pole_Smart_Breaker_40A.webp?v=1760614538"},{"product_id":"cnc-4p-rcbo-residual-current-circuit-breaker-ycb6hln-63","title":"RCBO 4P Residual Current Circuit Breakers 32A, 63A YCB6HLN","description":"\u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin-bottom:20px\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eNot sure which voltage protector you need?\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eTry our \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;font-weight:700\"\u003eVA Protector Product Finder Tool\u003c\/a\u003e — Pakistan's first interactive selector.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003e4 pole RCBO buyers in Pakistan choose the RCBO 4P 32A-63A YCB6HLN when they need one device that combines earth leakage protection, overload protection, and short-circuit protection on a three-phase circuit. Starting from Rs.3,000, this three phase RCBO suits workshops, offices, lifts, small machinery feeders, commercial panels, and other 400V AC applications where panel space, simplicity, and safety all matter. For many sites in Pakistan, a 4P RCBO is the cleaner alternative to fitting a separate 4P RCCB plus a separate 4P MCB.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eQuick Specs\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYCB6HLN 4P RCBO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e4 Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e400V AC three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eCurrent ratings\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e32A, 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eLeakage sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eProtection type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eEarth leakage + overload + short circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eIEC 61009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eRCBO stands for Residual Current Circuit Breaker with Overcurrent protection. In plain words, it combines two jobs in one device. First, it trips on dangerous earth leakage. Second, it trips on overload and short circuit. For three-phase panels, that is a big advantage because it reduces device count and simplifies the wiring layout inside the board.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eMany Pakistani buyers understand the difference only after panel space becomes a problem. A \u003ca href=\"\/products\/cnc-4p-rcbo-residual-current-circuit-breaker-ycb6hln-63\" style=\"color:#d42027\"\u003e4P RCCB\u003c\/a\u003e only handles leakage protection; it still needs a separate \u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027\"\u003e4P MCB\u003c\/a\u003e for overload and short circuit. A 4P RCBO combines both roles. That is why it is attractive for smaller commercial panels, pumps, workshop feeders, and three-phase loads where compactness matters.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product is especially useful where one three-phase outgoing circuit must be protected neatly in one modular device. It is not a substitute for surge protection or voltage quality protection, but it is the correct answer when the question is leakage plus overcurrent on a 3-phase line.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhen a 4P RCBO Makes More Sense Than RCCB + MCB\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose a 4P RCBO when you want one protective device for a three-phase feeder and you want to save space in the panel. It is practical in DB boards where multiple feeders already consume DIN rail space. It is also easier to explain to non-technical buyers because one product protects against two major categories of fault.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose separate devices when the design requires independent selection, coordination, or replacement of the RCCB and MCB functions. In bigger engineered panels, separate devices can still make sense. But for many real-world Pakistan jobs, especially compact panels, the all-in-one format is easier and cleaner.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSelection Guide\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eUse Case\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eRecommended Rating\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSmall three-phase commercial feeder\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e32A RCBO\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSuitable where the protected line current is moderate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eThree-phase office \/ workshop feeder\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e63A RCBO after design check\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMore headroom for larger outgoing line loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eNeed leakage only, already have overcurrent device\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e4P RCCB may be considered\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eRCBO is not always necessary if design is separate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eNeed one compact device for leakage + overcurrent\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e4P RCBO\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSaves space and simplifies the panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSingle-phase circuit only\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eUse 1P+N RCBO\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eDo not overspecify a 4P device for single-phase loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Install\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product should be installed by a licensed electrician or panel builder because three-phase wiring errors are costly and can be dangerous.\u003c\/p\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eIsolate the three-phase incoming supply and confirm zero voltage before touching the panel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eMount the RCBO on DIN rail and verify the correct incoming and outgoing terminal arrangement.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eConnect all poles correctly so phase sequence and neutral routing remain consistent with the design.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eTorque terminals properly and test the RCBO trip function before energizing the feeder.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eAfter commissioning, test leakage trip behavior and confirm load current is within the selected rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis 4 pole RCBO does not protect against lightning and switching surges, so add a \u003ca href=\"\/products\/4p-cnc-ac-spd-385v-surge-protection-devices-20ka-40ka-ycs6-b\" style=\"color:#d42027\"\u003e4P AC SPD\u003c\/a\u003e where surge risk exists. It does not protect against sustained overvoltage and undervoltage, so use a \u003ca href=\"\/products\/cnc-4p-3-phase-v-a-protection-device-63a-yc6-vas-3\" style=\"color:#d42027\"\u003e3-phase VA protector\u003c\/a\u003e if line conditions are poor. It is also not a substitute for good panel design, cable sizing, and coordination. The RCBO only covers earth leakage, overload, and short circuit on the protected circuit.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003e4P RCBO vs 4P RCCB + 4P MCB vs 1P+N RCBO\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003e4P RCBO\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003e4P RCCB + 4P MCB\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003e1P+N RCBO\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eLeakage protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eOverload \/ short circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eYes, via separate MCB\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eDevice count\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOne combined unit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eTwo separate units\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOne combined unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eBest use\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eThree-phase feeder\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eThree-phase panel with separate design choice\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eSingle-phase circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003ePanel space\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLower\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eHigher\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLower for single phase only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCNC vs Schneider \/ Other Brands\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eCNC\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSchneider\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eLocal brands\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eTypical price in Pakistan\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eStarts from Rs.3,000\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eUsually higher\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eVaries widely\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eThree-phase protection value\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eStrong price-to-performance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003ePremium but expensive\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften inconsistent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eVaries by channel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften unclear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003ePanel space saving\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eGood all-in-one solution\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eAlso available in premium ranges\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNot always easy to verify\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSuitability for Pakistan market\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eGood balance of cost and function\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eGood but pricier\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eMay look cheaper but riskier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCross-Category Recommendations\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIf you are buying a 4P RCBO, also look at the \u003ca href=\"\/products\/cnc-1p-n-rcbo-reliable-residual-current-circuit-protection\" style=\"color:#d42027\"\u003e1P+N RCBO\u003c\/a\u003e for single-phase lines, the \u003ca href=\"\/products\/cnc-4p-rcbo-residual-current-circuit-breaker-ycb6hln-63\" style=\"color:#d42027\"\u003e4P RCCB\u003c\/a\u003e if you need separate leakage protection, the \u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027\"\u003e4P MCB\u003c\/a\u003e for separate overcurrent control, the \u003ca href=\"\/products\/cnc-4p-3-phase-v-a-protection-device-63a-yc6-vas-3\" style=\"color:#d42027\"\u003e4P 3-phase VA protector\u003c\/a\u003e for voltage problems, and the \u003ca href=\"\/products\/4p-cnc-ac-spd-385v-surge-protection-devices-20ka-40ka-ycs6-b\" style=\"color:#d42027\"\u003e4P AC SPD\u003c\/a\u003e for surge protection.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBrowse \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003eAC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027\"\u003eDC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027\"\u003eAC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027\"\u003eDC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027\"\u003eMCCBs\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003eAC SPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027\"\u003eDC SPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-regulator\" style=\"color:#d42027\"\u003evoltage regulators \/ stabilizers\u003c\/a\u003e, \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027\"\u003eRCCB \/ RCBO\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003etypes of circuit breakers\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/solar-db-box-guide-everything-pakistan-installers-need-to-know\" style=\"color:#d42027\"\u003esolar DB guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/rccb-breaker-guide-pakistan-earth-leakage-protection\" style=\"color:#d42027\"\u003eRCBO vs ELCB guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003etypes of circuit breakers guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/voltage-protector-vs-stabilizer-which-one-does-your-home-actually-need\" style=\"color:#d42027\"\u003evoltage protector vs stabilizer\u003c\/a\u003e. This helps buyers understand where RCBO protection stops and where SPD or voltage protection begins.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products from CNC Electric\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-1p-n-rcbo-reliable-residual-current-circuit-protection\" style=\"color:#d42027\"\u003eRCBO 1P+N\u003c\/a\u003e — Rs.1,700\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-4p-rcbo-residual-current-circuit-breaker-ycb6hln-63\" style=\"color:#d42027\"\u003e4P RCCB\u003c\/a\u003e — See product\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027\"\u003e4P AC MCB\u003c\/a\u003e — Rs.1,850\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-4p-3-phase-v-a-protection-device-63a-yc6-vas-3\" style=\"color:#d42027\"\u003eVA 4P 3-Phase\u003c\/a\u003e — Rs.6,000\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/4p-cnc-ac-spd-385v-surge-protection-devices-20ka-40ka-ycs6-b\" style=\"color:#d42027\"\u003eAC SPD 4P\u003c\/a\u003e — Rs.4,800\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is a 4 pole RCBO used for?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA 4 pole RCBO is used on three-phase circuits where you want both earth leakage protection and overcurrent protection in one device.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the RCBO price in Pakistan for this model?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product starts from Rs.3,000. It is a practical three-phase protection option for buyers who want one compact device.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs a 4P RCBO better than a 4P RCCB?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThey do different jobs. A 4P RCBO includes overload and short-circuit protection as well, while a 4P RCCB needs a separate MCB.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I use this for a three-phase office or shop?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, that is one of the most common use cases, provided a licensed electrician confirms the correct rating and panel design.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes it protect against surges?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. Add a 4P AC SPD for lightning and switching surges because an RCBO is not a surge protector.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes it protect against low voltage and high voltage?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. For sustained overvoltage and undervoltage, add a 3-phase VA protector on the incoming line where needed.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is 30mA sensitivity for?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003e30mA is commonly used for personal-protection-level earth leakage tripping, helping disconnect a circuit when leakage becomes dangerous.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this available across Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, CNC Electric Pakistan supplies across Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, Peshawar, and other cities with free delivery positioning in these product pages.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor three-phase safety, the right protective chain is usually RCBO or RCCB, plus MCB coordination, plus SPD and voltage protection where needed. CNC Electric Pakistan offers free delivery, 5-year warranty support, and matching panel accessories. WhatsApp us at 0326-1111376. Pair with an \u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027\"\u003eaerosol fire extinguisher\u003c\/a\u003e for added panel safety.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:8px\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/rccb-breaker-guide-pakistan-earth-leakage-protection\" style=\"color:#d42027\"\u003eRCCB Breaker Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n","brand":"CNC ELECTRIC","offers":[{"title":"32A","offer_id":41924528930882,"sku":null,"price":3200.0,"currency_code":"PKR","in_stock":true},{"title":"63A","offer_id":41924528963650,"sku":"YCB6HLE-63","price":3200.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/RCBO_Earth_Leakage_Breaker_4_Pole.webp?v=1763970848"},{"product_id":"cnc-4p-ac-mcb-circuit-breaker-ycb7h-63","title":"AC 4 Pole MCB 20A, 32A, 40A, 63A","description":"\u003cdiv style=\"font-family:Segoe UI,Roboto,Arial,sans-serif;font-size:15px;line-height:1.7;color:#1a1a1a;\"\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eCNC 4 Pole MCB — Three-Phase Plus Neutral Miniature Circuit Breaker\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThe CNC YCB7-63N 4 pole MCB is a three-phase plus neutral (3P+N) miniature circuit breaker. It disconnects all four conductors — L1, L2, L3, and N — together in a single trip mechanism, giving complete isolation of a three-phase circuit. This is the standard choice for three-phase main incoming breakers in commercial, industrial, and large residential installations across Pakistan.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eUnlike the \u003ca href=\"\/products\/cnc-3p-mcb-ac-circuits-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e3 Pole MCB\u003c\/a\u003e which only switches the three phases, the 4 Pole version also switches the neutral — essential for true isolation during maintenance, for three-phase solar inverter AC output, and for star-connected loads where the neutral carries unbalanced current. A fault on any phase trips all four poles simultaneously, preventing the dangerous single-phasing condition that destroys three-phase motors and compressors.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eRated at 400V AC with C-curve trip response and 6kA breaking capacity per IEC 60898-1, the YCB7-63N 4P handles three-phase DB feeders, motor circuits with neutral, 3-phase pump starters, and solar inverter AC output protection. CNC Electric is a trusted MCB brand in Pakistan with a \u003cstrong\u003e5-year replacement warranty\u003c\/strong\u003e on all circuit breakers.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e4 Pole MCB — Three-phase + Neutral Miniature Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eYCB7-63N (4P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e4P (L1 + L2 + L3 + N — all four switched together)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eCurrent Ratings\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20A, 32A, 40A, 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e400V AC, 50Hz (3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e6kA at 400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eTrip Curve\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eC-curve (trips at 5-10× rated current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eIEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e35mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eModule Width\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e4 modules (72mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eUp to 25mm² cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMechanical Life\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eElectrical Life\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e5-year replacement warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eWhy 4 Pole (3P+N) Over 3 Pole?\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThe key difference between a 3 Pole and a 4 Pole MCB is whether the neutral is switched together with the phases. For Pakistani installations, the 4 Pole version is preferred in these situations:\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eThree-phase main incoming breaker.\u003c\/strong\u003e When WAPDA supply arrives on four conductors (3 phases + neutral), the main breaker should disconnect all four during maintenance or fault. A 3 Pole leaves the neutral connected; a 4 Pole fully de-energises the DB. Safety personnel can service the downstream panel only after full isolation — that requires a 4 Pole.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eThree-phase solar inverter AC output.\u003c\/strong\u003e Hybrid and on-grid 3-phase solar inverters generate their own live-and-neutral AC output. When the inverter is off, the neutral from the inverter side must be isolated from the neutral from WAPDA to prevent parallel-path issues. A 4 Pole MCB on the inverter output ensures the inverter neutral is switched together with the three phases.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eStar-connected three-phase loads.\u003c\/strong\u003e Loads wired in star configuration (heating elements, some motors, unbalanced lighting systems) use the neutral as a return path. The neutral can carry significant current under unbalanced conditions, so it must be switched with the phases during fault or maintenance.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eGenerator and ATS panels.\u003c\/strong\u003e When WAPDA and generator supplies are alternated via an \u003ca href=\"\/collections\/ats\" style=\"color:#d42027;\"\u003eAutomatic Transfer Switch\u003c\/a\u003e or manual \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003echangeover\u003c\/a\u003e, the neutral from each source is typically separate. The 4 Pole MCB on each source ensures the neutral of one source never conflicts with the neutral of the other.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eUse a 3 Pole instead\u003c\/strong\u003e if the load has no neutral (delta-connected motors, pumps, compressors), or if the neutral is handled separately via a common busbar.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003e4P MCB — Amperage Selection Guide\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eCable Size\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eTypical Application in Pakistan\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eSmall 3-phase sub-DB, 5 HP motor feeder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e6mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10 HP motor, 10 kW 3-phase solar inverter output, commercial sub-main\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e40A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e15 HP motor, 15 kW solar inverter output, medium commercial main\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e63A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\n\u003cstrong\u003eThree-phase main incomer\u003c\/strong\u003e for shop\/office, 20-25 HP motor, 20 kW solar inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eAbove 63A:\u003c\/strong\u003e move to a \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003e4-Pole MCCB\u003c\/a\u003e rated 100A–1600A for larger commercial and industrial installations.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eThree-Phase Motor Sizing with 4 Pole MCB\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eFor motor feeders, select the 4 Pole MCB at approximately 1.25× the motor full-load current on 400V 3-phase:\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eMotor Size\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eApprox FLC\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003e4P MCB\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e5 HP (3.7 kW)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~9A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10 HP (7.5 kW)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~18A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e15 HP (11 kW)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~27A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20 HP (15 kW)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~37A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eAbove 20 HP\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eOver 37A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003e4P MCCB 100A+\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eFor motors with heavy starting inrush (star-delta starter, DOL on 15 HP+), consider a D-curve MCB variant or pair this C-curve with a dedicated motor-protection relay. For 3-phase solar inverter AC output, size the MCB at approximately 1.25× the inverter rated AC output current.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003e3-phase main incoming breaker.\u003c\/strong\u003e Commercial shops, offices, small factories, large homes with 3-phase WAPDA supply. The 63A 4P sits at the top of the DB — all power flows through it first. Install a \u003ca href=\"\/collections\/phase-sequence-relay\" style=\"color:#d42027;\"\u003ephase sequence relay\u003c\/a\u003e immediately after for phase-reversal protection.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003e3-phase solar inverter AC output.\u003c\/strong\u003e On-grid and hybrid 3-phase solar inverters up to 22 kW. The 4P on the inverter output ensures the inverter (its live and neutral) can be completely isolated from the house DB during maintenance. For 25 kW+, use a 4P MCCB.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003e3-phase motor feeder with neutral.\u003c\/strong\u003e Star-connected 3-phase motors and loads (unbalanced lighting, heating elements, some HVAC systems) where the neutral carries actual current.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eGenerator 4-wire changeover panel.\u003c\/strong\u003e When the generator and WAPDA each provide their own neutral, the 4P MCB on each source ensures proper isolation during \u003ca href=\"\/collections\/ats\" style=\"color:#d42027;\"\u003eATS\u003c\/a\u003e or manual switching.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eAgricultural tube-well panels.\u003c\/strong\u003e Submersible pumps with 3-phase star-connected motors, especially when the panel is remote and requires full isolation for safe servicing.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eCommercial kitchen panels.\u003c\/strong\u003e 3-phase sub-DBs feeding ovens, heaters, chillers — often unbalanced loads with significant neutral current.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eInstallation Notes\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eWire the neutral through the 4th pole.\u003c\/strong\u003e Connect L1 to pole 1, L2 to pole 2, L3 to pole 3, and neutral to pole 4. All four poles trip together on a fault anywhere in the circuit.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eUse 6mm² copper for 32A and below; 10mm² for 40A; 16mm² for 63A.\u003c\/strong\u003e Size the neutral conductor the same as the phase conductors (not reduced) for unbalanced loads.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eTorque terminal screws to 2.5 Nm.\u003c\/strong\u003e Re-check tightness after 3 months of service. At 63A continuous, a loose terminal overheats and is a major cause of panel failures in Pakistan.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003ePlan DB space:\u003c\/strong\u003e this 4 Pole MCB is 72mm wide (4 modules). An 18-way DB with one 4P main incomer uses 4 modules, leaving 14 for branch circuits.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eRelated Products\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0 16px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eThree-phase without neutral → \u003ca href=\"\/products\/cnc-3p-mcb-ac-circuits-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e3 Pole MCB 16A-63A (Rs.1,350)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-phase branch circuits → \u003ca href=\"\/products\/cnc-1-pole-mcb-ac-breaker-ycb7-63a\" style=\"color:#d42027;\"\u003e1 Pole MCB 2A-63A (Rs.425)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-phase main incomer → \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027;\"\u003e2 Pole MCB 10A-63A (Rs.850)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAbove 63A or industrial fault levels → \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB 4P 100A-1600A\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003e3-phase generator auto-switching → \u003ca href=\"\/collections\/ats\" style=\"color:#d42027;\"\u003eATS 4-pole\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003e3-phase manual changeover → \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003eChangeover switches 4P\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePhase-sequence \/ reversal protection → \u003ca href=\"\/collections\/phase-sequence-relay\" style=\"color:#d42027;\"\u003ePhase Sequence Relay\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003e3-phase voltage protection → \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;\"\u003eVA Voltage Protector\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eMotor contactor for start\/stop → \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003eMagnetic contactors\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003e3-phase SPD \/ surge protection → \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD 4-pole\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eComplete 3-phase DB → \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB boxes\u003c\/a\u003e + breakers\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRead our guide → \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of Circuit Breakers in Pakistan\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is a 4 Pole MCB?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eA 4 Pole MCB is a miniature circuit breaker that protects a three-phase plus neutral (3P+N) circuit by disconnecting all four conductors — L1, L2, L3, and neutral — together on overload or short circuit. The four poles are mechanically linked so a fault on any phase or on the neutral trips all four. This gives complete isolation of the three-phase circuit, essential for main incomers and star-connected loads.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is the difference between 3 Pole and 4 Pole MCB?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eA 3 Pole MCB switches only the three phase conductors. A 4 Pole MCB switches all three phases plus the neutral. Use 3P for circuits without neutral (delta-connected motors) or where the neutral is handled by a separate busbar. Use 4P for three-phase main incomers, solar inverter 3-phase outputs, star-connected loads, and generator changeover panels that need complete isolation.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat size 4 Pole MCB for a three-phase main incomer?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eFor a typical 3-phase commercial or residential main incomer in Pakistan, use a \u003cstrong\u003e63A 4 Pole MCB\u003c\/strong\u003e with 16mm² copper cable. This handles roughly 20-25 HP total load. For larger loads, move to a \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003e4 Pole MCCB\u003c\/a\u003e rated 100A or higher. Pair the main 4P with a phase sequence relay for phase-reversal protection.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is the 4 Pole 63A MCB price in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eThe CNC YCB7-63N 4 Pole 63A MCB is available at Rs.1,900 at CNC Electric Pakistan. Competitor brands: Schneider iC60N 4P 63A typically costs Rs.7,500-10,000, and Chint NB1 4P 63A costs Rs.2,800-3,500. CNC offers equivalent IEC 60898-1 certified performance at a significantly lower price with a 5-year replacement warranty.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eCan I use a 4 Pole MCB for my 3-phase solar inverter?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eYes — for the AC output side of a 3-phase solar inverter, a 4 Pole MCB is the correct choice. It ensures the inverter's live and neutral are fully isolated from the house DB during maintenance. Size it at approximately 1.25× the inverter's rated AC output current. For the DC side (panels to inverter), never use an AC MCB — use \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027;\"\u003eDC circuit breakers\u003c\/a\u003e rated for your system voltage (500V, 1000V, or 1500V).\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eDoes the 4 Pole MCB provide motor overload protection?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003ePartially. The 4 Pole MCB protects the cable and panel against short circuit and trips on sustained overload. It does NOT detect motor-specific issues like stalled rotor, unbalanced phases, or phase reversal. For complete three-phase motor protection, combine this 4P MCB with (a) a thermal overload relay set to the motor FLC, (b) a phase sequence relay, and\/or (c) a motor-protection circuit breaker (MPCB) or VFD with built-in motor protection.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat breaking capacity does the CNC 4 Pole MCB have?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003e6kA at 400V AC per IEC 60898-1. This is adequate for residential, commercial, and small industrial 3-phase panels where the prospective short-circuit current is under 6 kA. For installations close to a large transformer where fault levels exceed 6 kA, move up to a 4P \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB\u003c\/a\u003e with 15-50 kA breaking capacity.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eHow wide is the 4 Pole MCB on the DIN rail?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eThe CNC YCB7-63N 4 Pole MCB is 72mm wide — four DIN-rail modules. Plan your DB box capacity accordingly: an 18-way DB with one 4P main incomer uses 4 modules, leaving 14 modules for branch circuits (single pole or 1P+N MCBs).\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"20A","offer_id":41924530929730,"sku":"YCB7-63N","price":1900.0,"currency_code":"PKR","in_stock":true},{"title":"32A","offer_id":41924530962498,"sku":"YCB7-63N","price":1900.0,"currency_code":"PKR","in_stock":true},{"title":"40A","offer_id":42324172832834,"sku":"YCB7-63N","price":1900.0,"currency_code":"PKR","in_stock":true},{"title":"63A","offer_id":41924530995266,"sku":"YCB7-63N","price":1900.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/4P_MCB_AC_Cricuit_Breaker.webp?v=1755855822"},{"product_id":"cnc-2p-wifi-smart-circuit-breaker-ycb9zf-100a-remote-control-protection","title":"Wi-Fi 2 Pole Circuit Breaker 100A | Remote Control \u0026 App Monitoring","description":"\u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin-bottom:20px\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eNot sure which voltage protector you need?\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eTry our \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;font-weight:700\"\u003eVA Protector Product Finder Tool\u003c\/a\u003e — Pakistan's first interactive selector.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eWifi circuit breaker buyers in Pakistan choose the Wi-Fi 2 Pole Circuit Breaker 100A YCB9ZF when they need smart MCB \/ breaker switch performance for real installations rather than improvised solutions. Starting from Rs.8,500, this product suits everyday use cases such as AC lines, geysers, water pumps, fridges, washing machines, solar inverter setups, UPS-backed circuits, DB boxes, and backup power panels depending on the application. MCB stands for Miniature Circuit Breaker, and buyers often still call it a safety breaker or breaker switch in the local market.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eQuick Specs\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYCB9ZF Wi-Fi 2 Pole Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e2 Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e63A, 100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eFunctions\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eRemote on\/off, timer, scheduling, energy monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOvercurrent and short circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eApp\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eTuya \/ Smart Life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis Wi-Fi 2 pole circuit breaker is a smart breaker that lets you switch power ON and OFF from your phone while still giving standard breaker protection against overload and short circuit. In Pakistan, that makes it especially useful for high-use loads such as geysers, ACs, water pumps, sign boards, small office equipment, and rental properties where owners want remote control without standing in front of the DB box.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eMany buyers search for a remote control breaker when their real problem is daily routine control. A geyser that should run only before bathing, a water pump that must be checked when no one is on site, or an AC that should start before arriving home are all good use cases. Because the device is DIN rail mounted, it fits cleanly inside distribution boards rather than hanging outside like improvised smart plugs.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt is also more suitable for larger fixed circuits than a plug-in gadget. This is why the YCB9ZF is often chosen where installers want a proper panel-mounted smart home breaker instead of a consumer plug timer.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe biggest searched use case in Pakistan is geyser timing. Instead of forgetting to switch it OFF or keeping it ON all day, you can automate timings and reduce waste.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhere It Fits Best in Pakistan\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product is relevant for buyers across Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar because electrical conditions, backup power usage, and solar adoption make practical protection choices important. Whether the load is a 1 ton AC, 1.5 ton AC, 2 ton AC, geyser, water pump, fridge, washing machine, solar inverter, or UPS-backed line, the main question is not just price in Pakistan but whether the product is doing the right job in the system.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThat is why CNC Electric Pakistan positions this model as part of a full product family rather than a one-off item. You can combine it with matching \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027\"\u003eDB boxes\u003c\/a\u003e, \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003ebreakers\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003esurge protectors\u003c\/a\u003e, and \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027\"\u003echangeover switches\u003c\/a\u003e depending on the site.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSelection Guide\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eAppliance \/ Load \/ Use Case\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eRecommended Rating \/ Variant\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eHome geyser control\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e63A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eEnough for most residential controlled circuits; lets you schedule on\/off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e1 ton to 1.5 ton AC circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e63A after electrician review\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eUseful where remote switching is needed and circuit design is suitable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e2 ton AC or heavier dedicated line\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e100A after system check\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eGives more headroom on larger dedicated applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWater pump \/ bore pump control\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e63A or 100A depending on feeder\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eChoose according to actual current and motor starting profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eOffice or shop master control\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e100A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eUseful where multiple controlled loads sit on one feeder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Install\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eInstallation should always be done by a licensed electrician or qualified solar installer. Clean wiring, correct torque, proper cable size, and testing matter as much as the product itself.\u003c\/p\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eTurn OFF the upstream supply and confirm isolation.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eMount the smart breaker on DIN rail in the DB box.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eConnect line and load terminals exactly as marked and tighten properly.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003ePair the breaker with Tuya or Smart Life app and test manual plus remote switching.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eTest overload protection and scheduling only after a licensed electrician verifies the circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis WiFi breaker does not replace a dedicated \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003esurge protector\u003c\/a\u003e for voltage spikes, does not replace an \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027\"\u003eRCBO\u003c\/a\u003e for earth leakage, and does not replace a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003eVA protector\u003c\/a\u003e for sustained overvoltage and undervoltage. It is a smart MCB style device, not an all-in-one power quality solution.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSmart Breaker vs Basic Breaker vs Smart Voltage Protector\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eOption 1\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eOption 2\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eOption 3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eRemote switching\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes on WiFi models only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eScheduling\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes on advanced WiFi VA models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eEnergy monitoring\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eAvailable on selected VA models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eOvercurrent \/ short circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eVaries by model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eVoltage protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eBest use case\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eRemote control of fixed circuits\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eBasic circuit protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eWhole-line voltage protection plus monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCNC vs Schneider and Local Brands\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eCNC\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSchneider\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eLocal Brands\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eTypical price in Pakistan\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eRs.8,500\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eUsually much higher\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eVaries but often inconsistent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eStandards \/ documented product line\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDefined branded family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003ePremium branded family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften unclear in low-end market stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eChannel dependent\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften limited or unclear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eValue for Pakistani buyers\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eStrong price-to-performance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003ePremium but expensive\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eCheaper-looking but riskier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eAvailability of matching accessories\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes across multiple collections\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDepends on range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften mixed products from many sellers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCross-Category Recommendations\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIf you are buying this product, also consider \u003ca href=\"\/products\/cnc-yc7va-wifi-kwh-63a-smart-protector-10-in-1-voltage-current-leakage-protection\" style=\"color:#d42027\"\u003eVA WiFi 10-in-1\u003c\/a\u003e Rs.5,200, \u003ca href=\"\/products\/cnc-2p-voltage-protection-device-1-80a-yc7va\" style=\"color:#d42027\"\u003eVA 2P Basic\u003c\/a\u003e Rs.1,700, \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027\"\u003e2P MCB\u003c\/a\u003e Rs.850, \u003ca href=\"\/products\/cnc-1p-n-rcbo-reliable-residual-current-circuit-protection\" style=\"color:#d42027\"\u003eRCBO\u003c\/a\u003e Rs.1,650, \u003ca href=\"\/products\/cnc-ac-spd-2p-275v-surge-protection-devices-20ka-40ka-ycs6-c\" style=\"color:#d42027\"\u003eAC SPD\u003c\/a\u003e Rs.2,500.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBrowse \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003eAC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027\"\u003eDC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027\"\u003eAC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027\"\u003eDC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027\"\u003eMCCBs\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003eAC SPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027\"\u003eDC SPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-regulator\" style=\"color:#d42027\"\u003evoltage regulators \/ stabilizers\u003c\/a\u003e, \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027\"\u003eRCCB \/ RCBO\u003c\/a\u003e, \u003ca href=\"\/blogs\/news\/cnc-smart-wifi-breaker-the-best-solution-for-geyser-ac-home-automation\" style=\"color:#d42027\"\u003esmart WiFi breaker guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003etypes of circuit breakers\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/mcb-size-chart-for-pakistan-pick-the-right-breaker-for-every-appliance\" style=\"color:#d42027\"\u003eMCB size chart for Pakistan\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/circuit-breaker-trip-curves-explained-b-c-and-d-curve-mcbs\" style=\"color:#d42027\"\u003etrip curves explained\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/spd-full-form-what-is-surge-protection-device-why-pakistan-needs-it\" style=\"color:#d42027\"\u003eSPD full form guide\u003c\/a\u003e for a complete project-level view before final selection.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products from CNC Electric\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-yc7va-wifi-kwh-63a-smart-protector-10-in-1-voltage-current-leakage-protection\" style=\"color:#d42027\"\u003eVA WiFi 10-in-1\u003c\/a\u003e — Rs.5,200\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-2p-voltage-protection-device-1-80a-yc7va\" style=\"color:#d42027\"\u003eVA 2P Basic\u003c\/a\u003e — Rs.1,700\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027\"\u003e2P MCB\u003c\/a\u003e — Rs.850\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-1p-n-rcbo-reliable-residual-current-circuit-protection\" style=\"color:#d42027\"\u003eRCBO\u003c\/a\u003e — Rs.1,650\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-ac-spd-2p-275v-surge-protection-devices-20ka-40ka-ycs6-c\" style=\"color:#d42027\"\u003eAC SPD\u003c\/a\u003e — Rs.2,500\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the wifi circuit breaker price in Pakistan for this product?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product starts from Rs.8,500. Final selection depends on the chosen variant or system requirement. CNC Electric Pakistan also offers free delivery and a 5-year warranty.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWho should buy the Wi-Fi 2 Pole Circuit Breaker 100A YCB9ZF?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis model suits buyers in Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar who need a proper panel-mounted solution rather than a market workaround.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan a normal electrician install this?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA licensed electrician or qualified solar installer should install it, because correct wiring, sizing, and testing matter more than the product alone.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eHow do I choose the right rating or variant?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose the variant according to actual load current, system voltage, cable size, and application. The selection guide above gives a starting point, but final sizing should be verified on site.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this better than cheap local market alternatives?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor serious installations, buyers usually prefer a defined product line, clearer specifications, and a 5-year warranty instead of inconsistent no-name market stock.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this replace every other protection device in the panel?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. Each product has a specific role. A complete system may also need MCBs, RCBOs, SPDs, voltage protectors, changeovers, ATS units, fuses, or DB boxes depending on the job.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this available across Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, CNC Electric Pakistan sells across Pakistan with common demand from Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhy buy from CNC Electric Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBecause buyers want practical price in Pakistan, coordinated related products, free delivery, and after-sales support instead of mixing random parts from different sources.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I compare this with other CNC products before ordering?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. Use the related products and collection links in this description to compare alternative ratings, premium upgrades, and matching protection accessories before placing the order.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor full system planning, compare the linked collections and guides above. CNC Electric Pakistan offers free delivery, coordinated product ranges, and a 5-year warranty. WhatsApp us at 0326-1111376.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:8px\"\u003eSee also: \u003ca href=\"\/blogs\/news\/wifi-smart-breaker-vs-normal-breaker-pakistan-comparison\" style=\"color:#d42027\"\u003eWiFi Breaker vs Normal Breaker\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"cnc-related-blog\" style=\"margin-top:1.5em;padding:1em;background:#f8f9fa;border-left:4px solid #fa3433;border-radius:6px;\"\u003e\u003cstrong\u003e📖 Related Reading:\u003c\/strong\u003e \u003ca href=\"\/blogs\/news\/wifi-smart-breaker-complete-guide-to-smart-circuit-breaker-with-remote-control-monitoring-in-pakistan\" title=\"WiFi Smart Breaker Complete Guide to Smart Circuit Breaker with Remote Control \u0026amp; Monitoring in Pakista\" style=\"color:#fa3433;font-weight:600;\"\u003eWiFi Smart Breaker Complete Guide to Smart Circuit Breaker with Remote Control \u0026amp; Monitoring in Pakista\u003c\/a\u003e — In-depth guide on this product category. \u003cbr\u003e\u003cem\u003eHelpful for understanding sizing, installation, and choosing the right model for your Pakistan setup.\u003c\/em\u003e\u003c\/p\u003e","brand":"CNC ELECTRIC","offers":[{"title":"100A","offer_id":42320911466562,"sku":"YCB9ZF-100A","price":9700.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/2P_WiFi_Smart_Circuit_Breaker.webp?v=1755858681"},{"product_id":"cnc-3-pole-20a-mccb-molded-case-circuit-breakers-ycm1","title":"AC 3 Pole  Molded Case Circuit Breaker 20A | Safe \u0026 Reliable Protection","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eMCCB breaker buyers in Pakistan usually want one thing: a compact breaker that can handle more serious panel duty than a small MCB. This AC 3 pole molded case circuit breaker 20A is listed by CNC Electric Pakistan at Rs.4,900 and is positioned for industrial and commercial protection work. It suits three-phase feeder control, small motor panels, machine circuits, utility boards and commercial distribution points where a molded case format makes more sense than a miniature breaker.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis page is for the local 20A, 3-pole YCM1 sale listing. The buying logic is straightforward. If the job is no longer a light domestic final circuit and you want a stronger body, better isolation feel and MCCB-style protection logic, this is the category to look at. In Lahore panel shops, Faisalabad textile support work and Karachi plant service jobs, a small three-phase MCCB like this is often used where a normal DIN breaker feels too light for the board.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e3 pole molded case circuit breaker listed locally in a 20A version.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eBuilt for AC distribution and equipment protection in industrial and commercial boards.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eIEC 60947-2 context for MCCB class equipment.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eCompact body with stronger panel feel than a light miniature breaker.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eUseful for feeder circuits, machine panels and infrequent motor-start related protection duty.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eCan be mounted vertically or horizontally according to published YCM1 family notes.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eSuitable where buyers want a real MCCB format instead of stretching a 3P MCB into a job it was not meant for.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLocal sale title\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAC 3 Pole Molded Case Circuit Breaker 20A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCurrent rating on local page\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e20A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePoles\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3 Pole\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated insulation voltage published for YCM1 family\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUp to 800V, with YCM1-63 noted to 500V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated working voltage published for YCM1 family\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUp to 690V, with YCM1-63 noted to 400V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProtection functions stated on local page\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOverload, short circuit and undervoltage class protection context\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eInstallation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eVertical or horizontal mounting noted for YCM1 family\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStandard\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIEC 60947-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eExact Icu \/ dimensions \/ accessory matrix for this local sale variant\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNot clearly published on the live local page and have not been guessed\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis description uses only live local sale-page data plus limited official YCM1 family notes where they clearly help the breaker class. Exact short-circuit values for this 20A local sale variant, full dimensions, terminal drawings, and accessory combinations are not clearly published on the local page and have not been guessed.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range and Local Sale Context\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eListing \/ Family Context\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePole Format\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCurrent\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrice \/ Note\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLocal sale variant\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3 Pole\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e20A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.4,900\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYCM1 family note\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3 Pole and other family formats exist\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUp to 1600A family range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFamily context only, not this local sale page\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis local page is not a broad selector with multiple amperes published in visible local pricing. It is a focused 20A sale listing. So the page is written around the exact local product first, while still explaining where a 20A 3-pole MCCB fits in the larger MCCB family.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications — Where to Use This AC MCCB 3 Pole 20A\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA 20A three-pole MCCB makes sense where the circuit is clearly industrial or commercial in nature, but not so large that you need a much heavier frame. In Lahore, this kind of breaker fits compact machine panels, service boards and building-services feeders. In Faisalabad, it can make sense on smaller textile support equipment, control panels and auxiliary machine feeders. In Karachi, panel builders and service technicians often use small MCCBs where the client wants a more substantial molded-case device instead of stretching a DIN breaker into a harder job.\u003c\/p\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eApplication\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy this MCCB fits\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhat else you may need\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSmall three-phase machine feeder\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMCCB format gives a stronger industrial feel than a light MCB on a machine board\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eMagnetic contactor\u003c\/a\u003e and \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003ethermal relay\u003c\/a\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCommercial utility sub-panel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUseful when the panel builder wants molded-case operation and isolation feel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003eSPD\u003c\/a\u003e and \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;font-weight:700\"\u003eDB box\u003c\/a\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAuxiliary feeder in an industrial board\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA compact MCCB is a cleaner fit than oversizing the protection category\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027;font-weight:700\"\u003eAC breakers\u003c\/a\u003e for smaller outgoing ways\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMotor duty with infrequent starts\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePublished YCM1 family notes mention infrequent motor-start protection context\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eContactor\u003c\/a\u003e, \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eoverload relay\u003c\/a\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eGenerator or changeover-associated feeder section\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eAppropriate where the feeder itself needs molded-case isolation and protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/ats\" style=\"color:#d42027;font-weight:700\"\u003eATS\u003c\/a\u003e or \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;font-weight:700\"\u003echangeover breaker\u003c\/a\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Choose the Right MCCB for This Job\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe main decision is not just current. It is breaker category. If the job is small, final-circuit style, and a DIN miniature breaker is enough, use an \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003eMCB circuit breaker\u003c\/a\u003e. If the board is industrial, the breaker body needs stronger isolation feel, and the feeder belongs in a molded-case protection category, a small MCCB is the better direction.\u003c\/p\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eYour requirement\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eUse this product?\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eReason\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed a 3-pole 20A molded-case breaker for an industrial\/commercial feeder\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThat is exactly what this local sale page is offering\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed a domestic final-circuit breaker for lights and sockets\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually no\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eA standard \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003eMCB\u003c\/a\u003e is usually the cleaner fit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed higher current or broader industrial feeder options\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMaybe not this exact listing\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMove up into the wider \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;font-weight:700\"\u003eAC MCCB Breakers\u003c\/a\u003e collection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed earth-leakage protection as the core requirement\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNo\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;font-weight:700\"\u003eRCBO \/ RCCB\u003c\/a\u003e where leakage protection is the main job\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eAC MCCB vs Alternatives — Why CNC?\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eComparison point\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCNC Electric\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eSchneider \/ ABB\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eChint \/ Clopal \/ local options\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTypical buyer reason\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWants branded industrial protection with local stock access and strong value\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually chosen for top-tier global brand preference and premium budgets\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOften chosen on price or ready market familiarity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLocal sale transparency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLive local listing shows exact sale item and price\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually depends on distributor or project quote flow\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eVaries heavily by seller and product traceability\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStandards trust\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIEC 60947-2 class positioning shown for family\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStrong global standards reputation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMust be checked seller by seller and model by model\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePrice posture\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStrong value in branded industrial category\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOften materially higher for similar category placement\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOften cheaper, but long-term buyer confidence varies\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product does not replace every other protection device in the panel. It does not provide earth-leakage protection like an \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;font-weight:700\"\u003eRCBO \/ RCCB\u003c\/a\u003e. It does not protect against voltage spikes like an \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003eSPD\u003c\/a\u003e. It does not stabilize bad utility voltage like a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;font-weight:700\"\u003evoltage protector\u003c\/a\u003e. It does not switch automatically between sources like an \u003ca href=\"\/collections\/ats\" style=\"color:#d42027;font-weight:700\"\u003eautomatic transfer switch\u003c\/a\u003e.\u003c\/p\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt is a molded case circuit breaker for the feeder or equipment circuit it is assigned to. Good panel design still needs the right coordination around it.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n  \u003col style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eConfirm the feeder current, load type and cable sizing before selecting the 20A MCCB.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount the breaker in a rigid, ventilated enclosure or panel board.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eUse proper tightening practice and confirm phase sequencing and load routing before energizing.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eKeep the MCCB coordinated with upstream and downstream devices so fault isolation remains sensible.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eIf the board includes motors, drives, or source transfer gear, review the rest of the protection chain rather than treating the MCCB as the only answer.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n  \u003cdiv style=\"margin-top:25px;padding:15px;background:#f9f9f9;border:1px solid #e0e0e0;border-radius:5px;\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin-bottom:10px;\"\u003eComplete Your Electrical Setup\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSurge Protection Devices (SPD)\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🔌 \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003eVoltage Protectors\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📦 \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB Boxes\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🧲 \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003eMagnetic Contactors\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🔥 \u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;\"\u003eFire Extinguishers\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:0;\"\u003e📖 \u003ca href=\"\/blogs\/news\/ac-mccb-breaker-complete-guide-to-moulded-case-circuit-breaker-features-applications\" style=\"color:#d42027;\"\u003eMCCB Guide\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003e\u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;font-weight:700\"\u003eAC MCCB Breakers\u003c\/a\u003e is the main category for larger molded-case options. For smaller feeder jobs you may also compare \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027;font-weight:700\"\u003eAC Breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;font-weight:700\"\u003eCircuit Breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;font-weight:700\"\u003eChangeover Breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/ats\" style=\"color:#d42027;font-weight:700\"\u003eATS\u003c\/a\u003e, and \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;font-weight:700\"\u003eRCBO \u0026amp; RCCB\u003c\/a\u003e. For related panel planning, see \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of Circuit Breakers Guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/news\/ac-mccb-breaker-complete-guide-to-moulded-case-circuit-breaker-features-applications\" style=\"color:#d42027;\"\u003eMCCB Guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/news\/changeover-breaker-complete-guide-in-pakistan\" style=\"color:#d42027;\"\u003eChangeover Breaker Guide\u003c\/a\u003e, and \u003ca href=\"\/blogs\/news\/1500v-dc-spd-explained-what-it-is-why-modern-solar-plants-need-it\" style=\"color:#d42027;\"\u003eSPD Full Form Guide\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the price of this AC MCCB 3 pole 20A in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe live local sale page showed this AC 3 pole 20A MCCB at Rs.4,900 when checked.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this an MCB or an MCCB?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis is an MCCB. It belongs to the molded case circuit breaker category, which is generally used for heavier feeder and industrial\/commercial board duty than a miniature breaker.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan this MCCB be used for motor protection?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe published YCM1 family notes mention motor-related protection for infrequent starts, but in practice a proper motor-control setup should usually include a contactor and overload relay too.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this suitable for a three-phase panel?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. It is a 3-pole breaker and is sold for AC three-phase molded-case protection duty.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat standard applies to this breaker class?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe YCM1 family is positioned under IEC 60947-2, which is the standard context for molded case circuit breakers.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I use this instead of an RCBO?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. If leakage protection is the key requirement, use an RCBO or RCCB. An MCCB does not replace that protection function.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhere is a small 20A MCCB usually used in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eTypical uses include smaller three-phase feeder panels, commercial service boards, machine-control feeders and compact industrial panel work in cities like Lahore, Faisalabad and Karachi.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhy would I choose this over a normal 3 pole MCB?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose it when the board belongs in the molded-case category and you want the stronger industrial breaker format, isolation feel and feeder-duty positioning of an MCCB rather than a light miniature breaker.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBuy this \u003ca href=\"\/products\/cnc-3-pole-20a-mccb-molded-case-circuit-breakers-ycm1\" style=\"color:#d42027;font-weight:700\"\u003eAC MCCB 3 Pole 20A\u003c\/a\u003e from CNC Electric Pakistan at the live listed price of Rs.4,900, subject to current stock and site updates. For breaker selection help, panel coordination advice, and delivery support across Pakistan, WhatsApp \u003ca href=\"https:\/\/wa.me\/923261111376\" style=\"color:#d42027;font-weight:700\"\u003e0326-1111376\u003c\/a\u003e. Orders above Rs.10,000 qualify for free delivery, and the site banner currently states a 5-year replacement warranty on breakers.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"20A","offer_id":42324031176770,"sku":"YCM1","price":4900.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/3_Pole_20A_MCCB_Molded_Case_Circuit_Breakers.webp?v=1755857823"},{"product_id":"cnc-dc-1-pole-125a-mcb-circuit-breakers-500v-ycb8s-125pv","title":"DC 1P MCB 500V 125A YCB1 | Reliable Protection","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.7;color:#222;max-width:820px\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:22px 0 8px;color:#1a1a1a\"\u003eCNC YCB8s-125PV DC 1 Pole MCB -- 500V 125A\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;font-size:15px;line-height:1.7\"\u003eA single-pole DC miniature circuit breaker rated at 500V and 125A, built specifically for photovoltaic and battery protection. This is the breaker you need when running high-current DC strings or battery bank feeds in solar installations across Pakistan.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 12px;font-size:15px;line-height:1.7\"\u003eThe YCB8s-125PV uses a DC-rated arc chute designed to extinguish the sustained DC arc that standard AC breakers cannot handle. Polarity-sensitive -- connect supply to the top terminal and load to the bottom terminal.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:22px 0 8px;color:#1a1a1a\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 18px;font-size:14px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003eYCB8s-125PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003e1 Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eRated Current\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eRated Voltage\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003eDC 500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eApplication\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003ePhotovoltaic \/ Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eBreaking Capacity\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003e35mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:22px 0 8px;color:#1a1a1a\"\u003eWhere It Fits\u003c\/h2\u003e\n\u003cul style=\"margin:8px 0 14px 18px;padding:0\"\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eBattery bank main disconnect for 48V lithium or lead-acid banks (up to 125A continuous)\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eSolar charge controller output breaker on systems up to 500V DC\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eDC bus protection in hybrid inverter setups\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eIndustrial DC motor feed protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#fffde7;border-left:3px solid #f9a825;padding:10px 14px;margin:14px 0;font-size:14px;border-radius:2px\"\u003e\n\u003cstrong\u003ePolarity matters:\u003c\/strong\u003e DC breakers are directional. The YCB8s-125PV must be wired with correct polarity (LINE on top, LOAD on bottom) or it will not clear faults safely.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"125A","offer_id":42324090847298,"sku":"YCB8s-125PV","price":1150.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/DC_1_Pole_125A_MCB_Circuit_Breakers_500V.webp?v=1755856193"},{"product_id":"cnc-4-pole-4g-wifi-smart-circuit-breaker-with-display","title":"Wi-Fi 4 Pole 4G 100A Smart Circuit Breaker | With Display \u0026 Advanced Protection","description":"\u003cp class=\"MsoNormal\"\u003eSeiko design, Cloud control, GPRS connection, small volume, High breaking\u003cbr\u003eability, flame-resistant material, Energy conservation and environment\u003cbr\u003eprotection, international standard, All-round service.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e● Data monitoring \u003cbr\u003e● Fault alarm, protection\u003cbr\u003e● Centralized management\u003cbr\u003e● Analysis of energy consumption\u003cbr\u003e● Portable barrier remover\u003cbr\u003e● Handle dangerous situations anytime and anywhere\u003cbr\u003e● Remote control\u003cbr\u003e● Rights management\u003cbr\u003e● The regional search\u003cbr\u003e● Data report\u003cbr\u003e● Remote location + diagnosis \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003e35 Powerful Features\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eComprehensively protect the safety of human electricity\u003cbr\u003e● Local + remote integrated control Local + remote leakage self-check\u003cbr\u003e● Operation record can be checked\u003cbr\u003e● Electrical fire factor monitoring\u003cbr\u003e● Fault early warning \u003cbr\u003e● Fault location\/fault alarm\u003cbr\u003e● Tripping protection\u003cbr\u003e● Over undervoltage protection\u003cbr\u003e● Overload protection\u003cbr\u003e● Over temperature protection\u003cbr\u003e● Open phase protection\u003cbr\u003e● Voltage\/current imbalance\u003cbr\u003e● Fault phase protection\u003cbr\u003e● Preventing electricity-stolen\u003cbr\u003e● Maintenance and overhauls closed by mistake\u003cbr\u003e● Current limit \u003cbr\u003e● Scene mode\u003cbr\u003e● Line timing \u003cbr\u003e● Rights management\u003cbr\u003e● Automatic reclosing\u003cbr\u003e● Generate report analysis automatically\u003cbr\u003e● Local + remote locking\u003cbr\u003e● The leakage protection current can be adjusted\u003cbr\u003e● Custom warning thresholds\u003cbr\u003e● Short circuit protection\u003cbr\u003e● Power contrast\u003cbr\u003e● Troubleshooting advice \u003cbr\u003e● Fault cause recording \u003cbr\u003e● Conditional linkage control\u003cbr\u003e● Centralized management \u003cbr\u003e● Power factor calculation\u003cbr\u003e● Historical data import\u003cbr\u003e● Electricity statistics \u003cbr\u003e● Chart simulation display\u003cbr\u003e● Status indication\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e \u003c\/b\u003eThe Changeover Switch can switch on, Load and break the circuit under normal\u003cbr\u003econditions, using as Switch Disconnectors.\u003cbr\u003eStandard: IEC 60947-5-1\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBasic functions and features\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003e● OLED lattice LIQUID crystal display has long life and good low temperature\u003cbr\u003echaracteristics;\u003cbr\u003e● Can be set as a communication gateway, through the ontology 485 interface for\u003cbr\u003ethe branch small current switch combination networking;\u003cbr\u003e● It integrates multiple protection functions such as over voltage, under voltage,\u003cbr\u003emissing phase, wrong phase, loss of voltage, overload, short circuit, leakage,\u003cbr\u003etemperature, voltage\/current imbalance, over power, under power, anti-power\u003cbr\u003etheft and so on into one, and supports early warning in accordance with the preset\u003cbr\u003eproportion;\u003cbr\u003e● Multiple functions can be closed, alarm, trip any combination, more widely\u003cbr\u003eapplicable;\u003cbr\u003e● Support 12 months frozen electric energy and 7 days frozen electric energy query,\u003cbr\u003elet the remote energy management more convenient;\u003cbr\u003e● Electric parameters such as active power, reactive power, apparent power and\u003cbr\u003epower factor are supported for collection and uploading;\u003cbr\u003e● Support positive and negative energy statistics.\u003cbr\u003e● RS485 in non-gateway mode supports DL\/T-645\/Modbus protocol and automatic\u003cbr\u003econversion;\u003cbr\u003e● Support external dry contact control, cabinet door control;\u003cbr\u003e● Support multiple groups of any time timer control closing, opening operation, so\u003cbr\u003ethat the control more arbitrary;\u003cbr\u003e● Multi-component modular design, optional collocation, more flexible use\u003cbr\u003e● Remote wireless communication technology, supporting 2G, 4G, Ethernet, Wi-Fi,\u003cbr\u003eBluetooth\u003cspan style=\"mso-spacerun: yes;\"\u003e  \u003c\/span\u003eMQTT and other communication modes;\u003cbr\u003e● Operation event alarm event failure event real-time reporting, so that you can\u003cbr\u003eknow your equipment running state anytime and anywhere; The alarm can be\u003cbr\u003eaccompanied by a buzzer prompt, and can be muted remotely or locally, making\u003cbr\u003ethe device alarm more intelligent;\u003cbr\u003e● Support a variety of remote OTA upgrade mode, so that equipment upgrade\u003cbr\u003emaintenance no longer trouble;\u003cbr\u003e● Hundreds of local event records (power on, power off) are stored, which can be\u003cbr\u003echecked at any time for accident cause analysis;\u003cbr\u003e● The clock is timed and synchronized on the cloud to ensure the accuracy of event\u003cbr\u003erecording time. The daily error is no more than 1S in the case of no network;\u003cbr\u003e● Real-time statistics of the number of events can focus on frequent abnormal,\u003cbr\u003esupport switching display in Chinese and English;\u003cbr\u003e● Support 12 months frozen electric energy and 7 days frozen electric energy query, let the remote energy management more convenient;\u003cbr\u003e● Electric parameters such as active power, reactive power, apparent power and power factor are supported for collection and uploading;\u003cbr\u003e● Support positive and negative energy statistics.\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" style=\"border-collapse: collapse; border: none; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; mso-yfti-tbllook: 1184; mso-padding-alt: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; background: #BFBFBF; mso-background-themecolor: background1; mso-background-themeshade: 191; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eItem\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-left: none; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: #BFBFBF; mso-background-themecolor: background1; mso-background-themeshade: 191; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eData\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eThermo-magnetic release characteristic\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eC type (Other types can be customized)\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eRated current (In)\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003e100A\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eRated short circuit capacity Icn\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003e10kA\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eShort circuit protection\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eWhen there is a short circuit fault, it can trip within 100ms\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eLeakage protection\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eWhen there is a leakage fault, it can trip within 100ms\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eLeakage protection value\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003e30mA (customizable)\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOver-voltage protection\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eAccording to the set value, the trip time: hard cut-off: 1s\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eUnder-voltage protection\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eAccording to the set value, the trip time: hard cut-off: 1s\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOver and under voltage protection setting\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eWhen voltage is over 275–300V or under 165–180V, can be set\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOff-delay setting\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003e0–99s, can be set\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOverload protection\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003e1–63A can be set, Off-delay time 0–99s can be set\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOver-current protection\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eD–10*C current can be set, Off-delay time 0–99s can be set\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOver power protection\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eThe amount of load change can be set, Off-delay time 0–99s can be set\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eUnder power protection\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eThe amount of load change can be set, Off-delay time 0–99s can be set\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003ePhase loss protection\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCan be set\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 16;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003ePhase sequence protection\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCan be set\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 17;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eDelay on power restoration\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003e0–300s can be set\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 18;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOperation times\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eRecord times of circuit breaker operations\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 19;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eDisplay\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eLCD screen displays total current, real-time, overload, short circuit, leakage, etc.\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 20;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCheck\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eTest buttons and fault recall buttons are available\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 21;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCommunication protocol\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eStandard Modbus protocol (optional RS485, WiFi, Zigbee, 4G)\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 22;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eRemote control\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCan be switched on\/off by remote control (e.g. app, software)\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 23;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eRemote fault alarm\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eFault information pushed to system (overload, leakage, etc.)\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 24;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCloud data storage\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCircuit breaker operation record uploaded to cloud, real-time access\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 25;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eFirmware upgrades\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eRemote upgrade available\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 26;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCustomizable modules and functions\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eModular combination and expansion; supports metering, temperature, smoke, arc detection, power limiting, surge protection, timing control, programmable scenes, etc.\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 27;\"\u003e\n\u003ctd rowspan=\"2\" valign=\"top\" style=\"border: solid #8EAADB 1.0pt; mso-border-themecolor: accent1; mso-border-themetint: 153; border-top: none; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-alt: solid #8EAADB .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eThe following functions can be set:\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOpen, close, alarm, jump-to-scene, etc.\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 28; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid #8EAADB 1.0pt; mso-border-bottom-themecolor: accent1; mso-border-bottom-themetint: 153; border-right: solid #8EAADB 1.0pt; mso-border-right-themecolor: accent1; mso-border-right-themetint: 153; mso-border-top-alt: solid #8EAADB .5pt; mso-border-top-themecolor: accent1; mso-border-top-themetint: 153; mso-border-left-alt: solid #8EAADB .5pt; mso-border-left-themecolor: accent1; mso-border-left-themetint: 153; mso-border-alt: solid #8EAADB .5pt; mso-border-themecolor: accent1; mso-border-themetint: 153; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCan be set to support overvoltage, undervoltage, overcurrent, overload, leakage, short circuit, phase loss, phase sequence, temperature, smoke, arc, power limit, energy metering, surge protection, timing, programmable scenes\u003c\/span\u003e\u003c\/b\u003e For over and under voltage protection, add a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protector\u003c\/a\u003e to your board.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cdiv style=\"margin-top:15px;font-size:14px\"\u003e\n\u003cstrong\u003e📖 Related Guides:\u003c\/strong\u003e\u003cul style=\"padding-left:18px;margin-top:5px\"\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/wifi-smart-breaker-complete-guide-to-smart-circuit-breaker-with-remote-control-monitoring-in-pakista\" style=\"color:#d42027\"\u003eWiFi Smart Breaker Complete Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/cnc-smart-wifi-breaker-the-best-solution-for-geyser-ac-home-automation\" style=\"color:#d42027\"\u003eSmart WiFi Breaker for Home\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"cnc-related-blog\" style=\"margin-top:1.5em;padding:1em;background:#f8f9fa;border-left:4px solid #fa3433;border-radius:6px;\"\u003e\u003cstrong\u003e📖 Related Reading:\u003c\/strong\u003e \u003ca href=\"\/blogs\/news\/wifi-smart-breaker-vs-normal-breaker-pakistan-comparison\" title=\"WiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\" style=\"color:#fa3433;font-weight:600;\"\u003eWiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\u003c\/a\u003e — In-depth guide on this product category. \u003cbr\u003e\u003cem\u003eHelpful for understanding sizing, installation, and choosing the right model for your Pakistan setup.\u003c\/em\u003e\u003c\/p\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"100A","offer_id":42324147470402,"sku":null,"price":53500.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/4-pole-4G-WiFi-Smart-Circuit-Breaker.webp?v=1755858998"},{"product_id":"cnc-2-pole-4g-wifi-smart-circuit-breaker-with-display","title":"Wi-Fi 2 Pole 4G 100A Smart Circuit Breaker | With Display \u0026 Advanced Protection","description":"\u003cp class=\"MsoNormal\"\u003eSeiko design, Cloud control, GPRS connection, small volume, High breaking\u003cbr\u003eability, flame-resistant material, Energy conservation and environment\u003cbr\u003eprotection, international standard, All-round service.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e● Data monitoring \u003cbr\u003e● Fault alarm, protection\u003cbr\u003e● Centralized management\u003cbr\u003e● Analysis of energy consumption\u003cbr\u003e● Portable barrier remover\u003cbr\u003e● Handle dangerous situations anytime and anywhere\u003cbr\u003e● Remote control\u003cbr\u003e● Rights management\u003cbr\u003e● The regional search\u003cbr\u003e● Data report\u003cbr\u003e● Remote location + diagnosis \u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003e35 Powerful Features\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eComprehensively protect the safety of human electricity\u003cbr\u003e● Local + remote integrated control Local + remote leakage self-check\u003cbr\u003e● Operation record can be checked\u003cbr\u003e● Electrical fire factor monitoring\u003cbr\u003e● Fault early warning \u003cbr\u003e● Fault location\/fault alarm\u003cbr\u003e● Tripping protection\u003cbr\u003e● Over undervoltage protection\u003cbr\u003e● Overload protection\u003cbr\u003e● Over temperature protection\u003cbr\u003e● Open phase protection\u003cbr\u003e● Voltage\/current imbalance\u003cbr\u003e● Fault phase protection\u003cbr\u003e● Preventing electricity-stolen\u003cbr\u003e● Maintenance and overhauls closed by mistake\u003cbr\u003e● Current limit \u003cbr\u003e● Scene mode\u003cbr\u003e● Line timing \u003cbr\u003e● Rights management\u003cbr\u003e● Automatic reclosing\u003cbr\u003e● Generate report analysis automatically\u003cbr\u003e● Local + remote locking\u003cbr\u003e● The leakage protection current can be adjusted\u003cbr\u003e● Custom warning thresholds\u003cbr\u003e● Short circuit protection\u003cbr\u003e● Power contrast\u003cbr\u003e● Troubleshooting advice \u003cbr\u003e● Fault cause recording \u003cbr\u003e● Conditional linkage control\u003cbr\u003e● Centralized management \u003cbr\u003e● Power factor calculation\u003cbr\u003e● Historical data import\u003cbr\u003e● Electricity statistics \u003cbr\u003e● Chart simulation display\u003cbr\u003e● Status indication\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e The Changeover Switch can switch on, Load and break the circuit under normal\u003cbr\u003econditions, using as Switch Disconnectors.\u003cbr\u003eStandard: IEC 60947-5-1\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eBasic functions and features\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003e● OLED lattice LIQUID crystal display has long life and good low temperature\u003cbr\u003echaracteristics;\u003cbr\u003e● Can be set as a communication gateway, through the ontology 485 interface for\u003cbr\u003ethe branch small current switch combination networking;\u003cbr\u003e● It integrates multiple protection functions such as over voltage, under voltage,\u003cbr\u003emissing phase, wrong phase, loss of voltage, overload, short circuit, leakage,\u003cbr\u003etemperature, voltage\/current imbalance, over power, under power, anti-power\u003cbr\u003etheft and so on into one, and supports early warning in accordance with the preset\u003cbr\u003eproportion;\u003cbr\u003e● Multiple functions can be closed, alarm, trip any combination, more widely\u003cbr\u003eapplicable;\u003cbr\u003e● Support 12 months frozen electric energy and 7 days frozen electric energy query,\u003cbr\u003elet the remote energy management more convenient;\u003cbr\u003e● Electric parameters such as active power, reactive power, apparent power and\u003cbr\u003epower factor are supported for collection and uploading;\u003cbr\u003e● Support positive and negative energy statistics.\u003cbr\u003e● RS485 in non-gateway mode supports DL\/T-645\/Modbus protocol and automatic\u003cbr\u003econversion;\u003cbr\u003e● Support external dry contact control, cabinet door control;\u003cbr\u003e● Support multiple groups of any time timer control closing, opening operation, so\u003cbr\u003ethat the control more arbitrary;\u003cbr\u003e● Multi-component modular design, optional collocation, more flexible use\u003cbr\u003e● Remote wireless communication technology, supporting 2G, 4G, Ethernet, Wi-Fi,\u003cbr\u003eBluetooth and other communication modes;\u003cbr\u003e● Operation event alarm event failure event real-time reporting, so that you can\u003cbr\u003eknow your equipment running state anytime and anywhere; The alarm can be\u003cbr\u003eaccompanied by a buzzer prompt, and can be muted remotely or locally, making\u003cbr\u003ethe device alarm more intelligent;\u003cbr\u003e● Support a variety of remote OTA upgrade mode, so that equipment upgrade\u003cbr\u003emaintenance no longer trouble;\u003cbr\u003e● Hundreds of local event records (power on, power off) are stored, which can be\u003cbr\u003echecked at any time for accident cause analysis;\u003cbr\u003e● The clock is timed and synchronized on the cloud to ensure the accuracy of event\u003cbr\u003erecording time. The daily error is no more than 1S in the case of no network;\u003cbr\u003e● Real-time statistics of the number of events can focus on frequent abnormal,\u003cbr\u003esupport switching display in Chinese and English;\u003cbr\u003e● Support 12 months frozen electric energy and 7 days frozen electric energy query, let the remote energy management more convenient;\u003cbr\u003e● Electric parameters such as active power, reactive power, apparent power and power factor are supported for collection and uploading;\u003cbr\u003e● Support positive and negative energy statistics.\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" style=\"border-collapse: collapse; border: none; mso-border-alt: solid windowtext .5pt; mso-yfti-tbllook: 1184; mso-padding-alt: 0in 5.4pt 0in 5.4pt; mso-border-insideh: .5pt solid windowtext; mso-border-insidev: .5pt solid windowtext;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-yfti-irow: 0; mso-yfti-firstrow: yes;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; mso-border-alt: solid windowtext .5pt; background: #BFBFBF; mso-background-themecolor: background1; mso-background-themeshade: 191; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eItem\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-left: none; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: #BFBFBF; mso-background-themecolor: background1; mso-background-themeshade: 191; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eData\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 1;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eThermo-magnetic release characteristic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eC type (Other types can be customized)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 2;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eRated current (In)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003e100A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 3;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eRated short circuit capacity Icn\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003e10kA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 4;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eShort circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eWhen there is a short circuit fault, it can trip within 100ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 5;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eLeakage protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eWhen there is a leakage fault, it can trip within 100ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 6;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eLeakage protection value\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003e30mA (customizable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 7;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOver-voltage protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eAccording to the set value, the trip time: hard cut-off: 1s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 8;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eUnder-voltage protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eAccording to the set value, the trip time: hard cut-off: 1s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 9;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOver and under voltage protection setting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eWhen voltage is over 275–300V or under 165–180V, can be set\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 10;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOff-delay setting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003e0–99s, can be set\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 11;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOverload protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003e1–63A can be set, Off-delay time 0–99s can be set\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 12;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOver-current protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eD–10*C current can be set, Off-delay time 0–99s can be set\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 13;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOver power protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eThe amount of load change can be set, Off-delay time 0–99s can be set\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 14;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eUnder power protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eThe amount of load change can be set, Off-delay time 0–99s can be set\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 15;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003ePhase loss protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCan be set\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 16;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003ePhase sequence protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCan be set\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 17;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eDelay on power restoration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003e0–300s can be set\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 18;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOperation times\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eRecord times of circuit breaker operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 19;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eDisplay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eLCD screen displays total current, real-time, overload, short circuit, leakage, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 20;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCheck\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eTest buttons and fault recall buttons are available\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 21;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCommunication protocol\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eStandard Modbus protocol (optional RS485, WiFi, Zigbee, 4G)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 22;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eRemote control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCan be switched on\/off by remote control (e.g. app, software)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 23;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eRemote fault alarm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eFault information pushed to system (overload, leakage, etc.)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 24;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCloud data storage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCircuit breaker operation record uploaded to cloud, real-time access\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 25;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eFirmware upgrades\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eRemote upgrade available\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 26;\"\u003e\n\u003ctd valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCustomizable modules and functions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eModular combination and expansion; supports metering, temperature, smoke, arc detection, power limiting, surge protection, timing control, programmable scenes, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 27;\"\u003e\n\u003ctd rowspan=\"2\" valign=\"top\" style=\"border: solid windowtext 1.0pt; border-top: none; mso-border-top-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eThe following functions can be set:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eOpen, close, alarm, jump-to-scene, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-yfti-irow: 28; mso-yfti-lastrow: yes;\"\u003e\n\u003ctd valign=\"top\" style=\"border-top: none; border-left: none; border-bottom: solid windowtext 1.0pt; border-right: solid windowtext 1.0pt; mso-border-top-alt: solid windowtext .5pt; mso-border-left-alt: solid windowtext .5pt; mso-border-alt: solid windowtext .5pt; background: white; mso-background-themecolor: background1; padding: 0in 5.4pt 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: black; mso-color-alt: windowtext;\"\u003eCan be set to support overvoltage, undervoltage, overcurrent, overload, leakage, short circuit, phase loss, phase sequence, temperature, smoke, arc, power limit, energy metering, surge protection, timing, programmable scenes\u003c\/span\u003e For over and under voltage protection, add a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protector\u003c\/a\u003e to your board.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cdiv style=\"margin-top:15px;font-size:14px\"\u003e\n\u003cstrong\u003e📖 Related Guides:\u003c\/strong\u003e\u003cul style=\"padding-left:18px;margin-top:5px\"\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/wifi-smart-breaker-complete-guide-to-smart-circuit-breaker-with-remote-control-monitoring-in-pakista\" style=\"color:#d42027\"\u003eWiFi Smart Breaker Complete Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/cnc-smart-wifi-breaker-the-best-solution-for-geyser-ac-home-automation\" style=\"color:#d42027\"\u003eSmart WiFi Breaker for Home\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:8px\"\u003eSee also: \u003ca href=\"\/blogs\/news\/wifi-smart-breaker-vs-normal-breaker-pakistan-comparison\" style=\"color:#d42027\"\u003eWiFi Breaker vs Normal Breaker\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"100A","offer_id":42324147535938,"sku":null,"price":47000.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/2_pole_4G_WiFi_Smart_Circuit_Breaker_With_Display.webp?v=1755858460"},{"product_id":"cnc-ac-1-pole-mcb-100a-circuit-breaker","title":"AC 1 Pole MCB 100A | Reliable Overload Protection","description":"\u003cdiv style=\"font-family:Segoe UI,Roboto,Arial,sans-serif;font-size:15px;line-height:1.7;color:#1a1a1a;\"\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eCNC 1 Pole 100A MCB — Heavy-Load Single-Pole Circuit Breaker\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThe CNC YCB9-125 is a high-ampere single-pole MCB rated at 100A — fitting into the gap between standard household MCBs (which top out around 63A) and bulky MCCBs. It gives you 100A protection in a compact 36mm (2-module) DIN-rail package that fits any standard Pakistani DB box.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eUnlike standard 6kA MCBs, this breaker is rated at \u003cstrong\u003e10 kA breaking capacity\u003c\/strong\u003e — meaning it can safely interrupt fault currents up to 10,000 amperes. That higher rating is necessary at the 100A level because short-circuit fault currents scale with supply capacity, and installations drawing 100A are usually closer to larger transformers where fault levels are higher.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eTypical use in Pakistan: \u003cstrong\u003emain incoming breaker for large single-phase residential or commercial premises\u003c\/strong\u003e, generator output protection on 15–20 kVA single-phase gensets, and solar inverter AC output protection where the inverter output exceeds the 63A capability of a standard MCB. CNC Electric is a trusted MCB brand in Pakistan with a \u003cstrong\u003e5-year replacement warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMCB — Heavy-Ampere Single Pole Miniature Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eYCB9-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1P (Single Pole — disconnects live wire only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRated Current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e230V AC, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\n\u003cstrong\u003e10kA at 230V AC\u003c\/strong\u003e (higher than standard 6kA MCBs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eTrip Curve\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eC-curve (trips at 5-10× rated current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eIEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e35mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eModule Width\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2 modules (36mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eUp to 50mm² cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRequired Cable Size\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e25mm² copper for 100A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMechanical Life\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eElectrical Life\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e5-year replacement warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eWhen to Use a 100A MCB Instead of an MCCB\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eAt 100A, you sit at the boundary between the MCB world (up to 125A) and the \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB world\u003c\/a\u003e (100A–1600A). The choice between them depends on four factors:\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eFactor\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003e100A MCB (this product)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003e100A MCCB\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eBreaking capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10 kA\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e15–50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eTrip settings\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eFixed (C-curve)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003ePhysical size\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2 DIN modules (36mm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eLarge panel-mount (100–150mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003ePrice\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRs.1,200\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRs.5,500–9,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eBest for\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eResidential main incomer, small commercial premises\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eIndustrial panels, high fault-level installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eChoose this 100A MCB if:\u003c\/strong\u003e your prospective short-circuit current is below 10 kA (typical for residential and light commercial premises), you want a compact DIN-rail breaker, and you need a fixed C-curve trip. \u003cstrong\u003eMove to a 100A \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB\u003c\/a\u003e if:\u003c\/strong\u003e you are in an industrial environment close to a large transformer, or you need adjustable trip settings for motor coordination.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eWhere to Use the 100A Single-Pole MCB\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eMain incoming breaker for a large single-phase home\u003c\/strong\u003e — a house with 4+ air conditioners, electric geyser, EV charger, and large inverter easily draws over 63A. The 100A MCB sits at the top of the DB, with branch \u003ca href=\"\/products\/cnc-1-pole-mcb-ac-breaker-ycb7-63a\" style=\"color:#d42027;\"\u003e1 Pole MCBs\u003c\/a\u003e feeding the individual circuits. Pair it with a \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;\"\u003evoltage protector\u003c\/a\u003e and \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e on the outgoing side.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eSingle-phase generator output protection\u003c\/strong\u003e — 15–20 kVA single-phase gensets produce roughly 65–87A continuous output. A 100A MCB on the generator's output panel protects the feeder cable and isolates the gen-set for maintenance without needing to move to an MCCB.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eSolar inverter AC output\u003c\/strong\u003e — hybrid and off-grid solar inverters rated 15–22 kW single-phase produce roughly 65–96A AC output. The 100A MCB is the standard AC-side protection element on the inverter feeder, positioned between the inverter and the house DB.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eShop or small commercial main breaker\u003c\/strong\u003e — retail outlets, clinics, and small restaurants with high refrigeration and AC loads. Simpler and cheaper than an MCCB where the fault current is under 10 kA.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eLarge UPS output distribution\u003c\/strong\u003e — 10-20 kVA single-phase UPS systems feeding multiple downstream DB boards.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eImportant Wiring Notes\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eUse 25mm² copper cable minimum.\u003c\/strong\u003e 100A continuous current in a 16mm² cable overheats and eventually ignites insulation. The cable is the first thing to fail, not the breaker. For longer runs (over 15 metres) or high ambient temperature, go up to 35mm² cable to allow for voltage drop.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eTighten terminal screws to specification.\u003c\/strong\u003e At 100A, a loose termination generates heat, discolours insulation, and can fuse the terminal into the conductor. Use a torque screwdriver and tighten to 2.5–3 Nm (or whatever the terminal label specifies). Check tightness again after 3 months of service.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eProvide panel ventilation.\u003c\/strong\u003e At 100A continuous, the breaker dissipates heat. A closed DB box in a Pakistani summer can exceed 55°C internally, derating the breaker by up to 20%. Either up-size to 125A or provide forced ventilation on installations running near full load.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003ePair with a 2 Pole or 4 Pole upstream.\u003c\/strong\u003e For full isolation of both live and neutral (required during maintenance), this 1 Pole breaker should be preceded by a 2 Pole or 4 Pole main isolator. Alternatively, install this 100A MCB on only the live conductor and use a separate 100A neutral link.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eRelated Products\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0 16px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eBranch circuits (downstream) → \u003ca href=\"\/products\/cnc-1-pole-mcb-ac-breaker-ycb7-63a\" style=\"color:#d42027;\"\u003e1 Pole MCB 2A-63A (Rs.425)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eMain incomer with neutral switching → \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027;\"\u003e2 Pole MCB 10A-63A (Rs.850)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eThree-phase main incomer → \u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e4 Pole MCB 20A-63A (Rs.1,900)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAbove 100A or industrial fault levels → \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB breakers 100A-1250A\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eVoltage over\/under protection → \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;\"\u003eVA Voltage Protector\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eLightning \/ surge protection → \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD surge protectors\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eEarth leakage protection → \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO breakers\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAutomatic WAPDA\/generator switching → \u003ca href=\"\/collections\/ats\" style=\"color:#d42027;\"\u003eATS Automatic Transfer Switches\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eManual WAPDA\/generator switching → \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003eChangeover switches\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eComplete DB setup → \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB boxes\u003c\/a\u003e + breakers\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRead our guide → \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of Circuit Breakers in Pakistan\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is a 100A MCB used for?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eA 100A MCB is used as the main incoming breaker for large single-phase residential or commercial installations where the total load exceeds 63A — the limit of a standard household MCB. Typical applications include main breaker for a large home with multiple ACs, output protection for 15-20 kVA single-phase generators, AC output of large solar inverters, and main breaker for small commercial premises like shops or clinics.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat cable size do I need for a 100A MCB?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eUse \u003cstrong\u003e25mm² copper cable\u003c\/strong\u003e as the minimum. For runs longer than 15 metres or in hot environments, step up to 35mm² to allow for voltage drop and cable derating. Never use aluminium cable directly on MCB terminals — if aluminium supply cable arrives, terminate via a bi-metallic lug to copper pigtail at the breaker.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhy is the breaking capacity 10 kA instead of 6 kA?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eBreaking capacity has to match the prospective short-circuit current at the point of installation. Standard household circuits (branch level) have fault currents under 6 kA, so 6 kA MCBs are adequate. At the main incomer level drawing 100A, fault currents are typically 8–10 kA, so the 100A MCB is rated at 10 kA to safely interrupt those faults. If your main incomer is close to a large transformer where fault currents exceed 10 kA, move up to a 100A MCCB with 15–50 kA breaking capacity.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is the 100A MCB price in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eThe CNC YCB9-125 1 Pole 100A MCB is available at Rs.1,200 at CNC Electric Pakistan. Competitor brands: Schneider iC60N 1P 100A typically costs Rs.4,500–6,000, and Chint NB1 1P 100A costs Rs.1,800–2,200. CNC offers equivalent IEC 60898-1 certified performance with 10 kA breaking capacity at a significantly lower price with a 5-year replacement warranty.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eShould I use a 100A MCB or a 100A MCCB?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eUse the 100A MCB if your prospective fault current at the installation point is under 10 kA (typical for residential and light commercial premises). Use a \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003e100A MCCB\u003c\/a\u003e if you are in an industrial environment close to a large transformer (fault level above 10 kA), or if you need adjustable trip settings for motor coordination or selective tripping between main and sub-mains.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eCan I use a 100A MCB on a three-phase supply?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eNo. This is a single-pole MCB for single-phase circuits (230V AC). For three-phase 400V applications requiring 100A protection, use an \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB\u003c\/a\u003e rated 100A 3P or 4P, or combine three of these 1-pole MCBs linked mechanically (not recommended for safety reasons — go to the MCCB).\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eDoes the 100A MCB need a separate neutral switch?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eYes — since this is a single-pole breaker, the neutral is not switched. For full-isolation maintenance, install either a separate 100A isolator on the neutral wire, or pair this 1P MCB with a main 2 Pole MCB upstream. In most modern installations, you would use a true \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027;\"\u003e2 Pole MCB\u003c\/a\u003e at the main incomer if the load is below 63A, and this 100A 1 Pole for heavier loads with a separate neutral isolator.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eHow much DB space does the 100A MCB occupy?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eThe CNC YCB9-125 100A MCB is 36mm wide — two DIN-rail modules. That makes it the same width as a 2 Pole MCB, allowing easy substitution in existing DB layouts. Plan your DB capacity: a 12-way DB with this 100A main and 10 branch 1 Pole MCBs uses 2 modules for the main + 10 for branches = 12 total, fitting exactly.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"100A","offer_id":42324151369794,"sku":"YCB9-125","price":1200.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/1P_100A_MCB_AC_Circuit_Breaker.webp?v=1755853207"},{"product_id":"cnc-1p-wifi-smart-circuit-breaker-ycb9zf-63a-remote-control","title":"Wi-Fi 1 Pole Circuit Breaker 32A, 63A |  Remote Control \u0026 App Monitoring","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eLooking for a WiFi smart breaker price in Pakistan for home loads, office circuits, shop control, or a remotely managed panel? This CNC Electric 1 pole smart breaker is built for users who want breaker protection plus app-based switching and monitoring in one compact device. It is especially useful where you need to turn a circuit ON or OFF from a distance, check status without opening the board, and add a smarter protection layer to a normal electrical panel. For Pakistan users dealing with load issues, remote sites, rental units, or daily convenience needs, this WiFi breaker is a practical upgrade over a plain breaker switch.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e1 pole WiFi smart breaker with local and remote integrated control.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eSurfaced local variants include 32A and 63A, which makes it practical for different single-phase circuit needs.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e6kA short-circuit breaking capacity for practical residential and light commercial breaker duty.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eRemote ON\/OFF control through mobile app, with handle-based local manual operation still available.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eData monitoring, operation records, electricity statistics, and real-time status checking through the phone app.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eElectrical fire monitoring, fault early warning, and remote leakage self-check positioning on the local page.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eOver-voltage and under-voltage tripping logic with adjustable timing according to the published page description.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eAutomatic reclosing, locking, rights management, and centralized management functions give it more practical value than a normal \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ebreaker\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003ePublished \/ Safe-to-State Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eWi-Fi 1P Smart Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eModel Reference\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCB9ZF-100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eLocal Selling Variants\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e32A, 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e1 Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePublished Rated Current Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e32A, 40A, 63A, 80A, 100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eShort-Circuit Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRelease Characteristic\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eC type (other types can be customized)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eShort-Circuit Trip Response\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eCan trip within 100ms on short circuit fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOver \/ Under Voltage Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eTrips after 3s by default, adjustable from 0-99s; percentage can be set for over and under voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOverload Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eMeets IEC 60898-1 requirement according to rated current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eCommunication Mode\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eWireless WiFi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eMechanical Life\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eMore than 20,000 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eElectrical Life\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eMore than 6,000 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eSize on Local Page\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e55 × 77 × 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eCurrent Local Listing Price\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs. 8,300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eHonesty Note\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eThis description uses only data published on the live local page that surfaced. Exact app brand, enclosure IP rating, and detailed wiring diagram were not clearly listed there and have not been guessed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range \/ Variant Table\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eLocal Variant\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003ePoles\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eCurrent\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eTypical Use\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCB9ZF-100W\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e1 Pole\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRemote control of lighting, sockets, small AC feeder, and smart single-phase loads\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs. 8,300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCB9ZF-100W\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e1 Pole\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e63A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eHeavier single-phase remote switching where stronger current handling is needed\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs. 8,300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe live local page clearly surfaces 32A and 63A selling variants. The description table on the same page also mentions a broader rated-current family, but those higher-current options were not surfaced as active local variants on this specific page section used for this draft.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eHome circuits where the user wants app control of a breaker instead of walking to the board every time a circuit needs switching.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eOffice and shop panels where remote status checking and remote ON\/OFF help with after-hours control.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eRental units, farmhouses, second homes, and remote properties in Lahore, Karachi, Islamabad, or other cities where the owner may not always be on site.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eSmart-panel projects that want voltage\/status visibility, operation records, and remote switching in one breaker device.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eSingle-phase feeder circuits where a WiFi breaker adds more control value than a plain \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027;\"\u003eAC breaker\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003ePanels that also need \u003ca href=\"\/collections\/energy-meters\" style=\"color:#d42027;\"\u003eEnergy Meters\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003eVoltage Protectors\u003c\/a\u003e, and \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSurge Protection Devices\u003c\/a\u003e in a smarter setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSizing \/ Selection Guide\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose this smart breaker when the circuit is single-phase, the user wants remote control and monitoring, and the feeder current fits the surfaced 32A or 63A local options. The main checks are load current, whether the circuit is actually 1 pole, and whether the project needs smart control or just normal protection.\u003c\/p\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong style=\"font-size:15px;\"\u003eChoose 32A\u003c\/strong\u003e for lighter single-phase circuits where remote control and smart protection are needed without oversizing the device.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong style=\"font-size:15px;\"\u003eChoose 63A\u003c\/strong\u003e for heavier single-phase circuits where the load demand is higher but still within the page's local selling option.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong style=\"font-size:15px;\"\u003eChoose a 2 pole or 4 pole smart breaker\u003c\/strong\u003e if the circuit is not actually a 1 pole single-phase application. See \u003ca href=\"\/collections\/wifi-smart-circuit-breakers\" style=\"color:#d42027;\"\u003eWiFi Smart Breakers\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong style=\"font-size:15px;\"\u003eChoose this device\u003c\/strong\u003e if you want breaker protection plus remote switching, data monitoring, and status reporting in one unit.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong style=\"font-size:15px;\"\u003eBuild the whole smart panel properly\u003c\/strong\u003e with the right \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003ebreaker coordination\u003c\/a\u003e, \u003ca href=\"\/collections\/energy-meters\" style=\"color:#d42027;\"\u003emetering\u003c\/a\u003e, and protection strategy instead of relying only on one smart breaker.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWiFi Smart Breaker vs Alternatives — Why CNC?\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIn Pakistan, the real comparison is not just smart breaker versus smart breaker. It is smart control versus plain control, and properly protected remote switching versus random WiFi switches that are not real breaker devices. That is where this product has practical value.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eBuying Factor\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eCNC Electric\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eSchneider\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eABB\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eChint\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eClopal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBest fit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eSingle-phase smart control circuits, homes, offices, shops, remote panels\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePremium consultant-led smart-power ecosystems\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eHigher-end project-led smart-power ecosystems\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eMainstream branded alternative\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBudget-led local comparison point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eSmart-control logic\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRemote control, app status, operation records, data monitoring, rights management\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOften premium-brand driven\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOften premium-brand driven\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eStrong commercial familiarity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOften chosen mainly on first cost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eProtection angle\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e6kA breaker function plus over\/under-voltage, fault warning, and remote control\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eUsually broader premium ecosystem buying\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eUsually broader premium ecosystem buying\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eGood practical market relevance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eMay be chosen more on price than protection depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eWhy buyer chooses it\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBecause it gives real breaker protection plus smart remote control in one device\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBecause the project is premium-brand driven\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBecause the project is premium-brand driven\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBecause it balances brand familiarity and practicality\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBecause the decision is heavily cost-led\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eIt is not a whole-house smart system by itself. It only controls and protects the specific circuit connected through it.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eIt is not a substitute for a full \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCCB \/ RCBO\u003c\/a\u003e strategy where the panel design requires dedicated residual-current protection.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eIt is not an \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e and does not replace surge protection for sensitive electronics.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eIt does not fix poor earthing, weak WiFi coverage, bad panel design, or incorrectly sized load circuits.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eIt is a 1 pole device and should not be used as if it were a 2 pole or 4 pole solution for other circuit types.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n\u003col style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eConfirm the circuit is genuinely a 1 pole single-phase application and that the load current suits the 32A or 63A local option being selected.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eMount the smart breaker neatly in a proper \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB box\u003c\/a\u003e or panel with clear source and load identification.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eConnect the circuit correctly and commission the breaker locally first before depending on remote operation.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003ePair the breaker with the mobile app and verify status reporting, ON\/OFF response, and any timing or locking settings required by the job.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eTest over\/under-voltage logic, trip behavior, and remote control under safe supervised conditions before handing over the panel.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eComplete the panel with \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protection\u003c\/a\u003e, and the \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027;\"\u003eFire Extinguisher Guide\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCross-Category Links\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/wifi-smart-circuit-breakers\" style=\"color:#d42027;\"\u003eWiFi Smart Breakers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003eCircuit Breakers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027;\"\u003eAC Breakers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO \u0026amp; RCCB\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/energy-meters\" style=\"color:#d42027;\"\u003eEnergy Meters\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003eVoltage Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;\"\u003eVoltage Protector Finder Tool\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSurge Protection Devices\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB Boxes\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;\"\u003eFire Extinguishers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO vs RCCB Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eMCB Full Form Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/blogs\/guides\/safety-breaker\" style=\"color:#d42027;\"\u003eSafety Breaker Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of Circuit Breakers Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027;\"\u003eFire Extinguisher Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is a WiFi smart breaker?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eA WiFi smart breaker is a circuit breaker that combines normal breaker protection with remote app-based control and monitoring features.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the WiFi 1 pole smart breaker price in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eThe live CNC Electric Pakistan page currently shows this WiFi 1 pole smart breaker at Rs. 8,300 for the surfaced 32A and 63A variants.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I control this breaker from my phone?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eYes. The local page says the voltage and switching status can be checked through the app on the phone, and the breaker can be remotely controlled.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this smart breaker protect against short circuit?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eYes. The page lists a 6kA short-circuit capacity and says it can trip within 100ms when there is a short-circuit fault.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes it also have over and under voltage protection?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eYes. The local page says it can trip on over or under voltage, with adjustable timing from 0 to 99 seconds.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I still operate it manually?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eYes. The local page clearly says it supports manual and automatic integrated control, with app control and handle-based local control.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this better than a normal breaker?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eIt is better when the project needs remote switching, status checking, electrical-fire monitoring, records, and other smart-control functions. If the job only needs basic protection, a normal breaker may be enough.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan this replace an RCCB or RCBO completely?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eNot always. Panel design still matters. Some jobs still need dedicated \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCCB \/ RCBO\u003c\/a\u003e strategy depending on the protection requirement.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat circuits is this most suitable for?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eIt is most suitable for single-phase circuits where remote switching, monitoring, and smarter fault-handling are useful, such as homes, offices, shops, or managed panels.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat should I add with this WiFi smart breaker for a better panel?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eA better-finished panel usually includes the right \u003ca href=\"\/collections\/energy-meters\" style=\"color:#d42027;\"\u003eenergy meter\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protection\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e, and nearby \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;\"\u003epanel fire protection\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eIf you want a real smart breaker in Pakistan instead of a plain remote switch, this CNC Electric 1 pole WiFi breaker is a strong practical option. It gives you breaker protection, app control, live status visibility, records, and smarter fault-handling in one product that fits a proper electrical panel. For stock confirmation, 32A versus 63A selection, or help pairing it with the right protection and metering devices, contact CNC Electric Pakistan on WhatsApp before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"cnc-related-blog\" style=\"margin-top:1.5em;padding:1em;background:#f8f9fa;border-left:4px solid #fa3433;border-radius:6px;\"\u003e\u003cstrong\u003e📖 Related Reading:\u003c\/strong\u003e \u003ca href=\"\/blogs\/news\/wifi-smart-breaker-complete-guide-to-smart-circuit-breaker-with-remote-control-monitoring-in-pakistan\" title=\"WiFi Smart Breaker Complete Guide to Smart Circuit Breaker with Remote Control \u0026amp; Monitoring in Pakista\" style=\"color:#fa3433;font-weight:600;\"\u003eWiFi Smart Breaker Complete Guide to Smart Circuit Breaker with Remote Control \u0026amp; Monitoring in Pakista\u003c\/a\u003e — In-depth guide on this product category. \u003cbr\u003e\u003cem\u003eHelpful for understanding sizing, installation, and choosing the right model for your Pakistan setup.\u003c\/em\u003e\u003c\/p\u003e","brand":"CNC ELECTRIC","offers":[{"title":"55*77*90mm \/ 32A","offer_id":42324168507458,"sku":"YCB9ZF-63A","price":7500.0,"currency_code":"PKR","in_stock":true},{"title":"55*77*90mm \/ 63A","offer_id":42324168474690,"sku":"YCB9ZF-63A","price":7500.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/1P_WiFi_Smart_Circuit_Breaker.webp?v=1755858219"},{"product_id":"cnc-dc-2p-circuit-battery-breakers-500v-125a-ycb1-125-high-voltage","title":"DC 2 Pole MCB 500V 125A | for Battery Protection","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBattery breaker buyers in Pakistan choose the DC 2 Pole 500V 125A Battery Breaker YCB1-125 when they need high-current DC battery breaker performance for real installations rather than improvised solutions. Starting from Rs.2,500, this product suits everyday use cases such as AC lines, geysers, water pumps, fridges, washing machines, solar inverter setups, UPS-backed circuits, DB boxes, and backup power panels depending on the application. MCB stands for Miniature Circuit Breaker, and buyers often still call it a safety breaker or breaker switch in the local market.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eQuick Specs\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYCB1-125 Battery Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e2 Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eCurrent Ratings\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e80A, 100A, 125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eUse\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eBattery bank protection \/ high-current DC circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003ePanel \/ DIN rail style application depending setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eHybrid solar, lithium battery banks, DC storage lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis 2 pole 500V 125A battery breaker is designed for battery bank protection where fault current can be much higher and more dangerous than an ordinary small solar string circuit. That is why the 10kA breaking capacity matters. Battery systems, especially lithium and hybrid solar setups, can deliver massive short-circuit current very quickly. A standard lighter-duty DC MCB may not be the correct answer for that job.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIn Pakistan, more hybrid systems now combine lithium batteries, inverters, and high-current DC wiring. Buyers often focus only on amp rating and miss the interruption capability. But a battery breaker is not just about carrying 80A, 100A, or 125A. It is about safely interrupting a serious DC fault. That is the whole point of using a more suitable breaker for battery lines.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eUse this where you need battery-side isolation and protection in a higher-current DC system, not just ordinary PV string protection.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe important message for hybrid solar buyers is simple: batteries are not ordinary DC strings, so battery-side protection should not be chosen casually.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhere It Fits Best in Pakistan\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product is relevant for buyers across Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar because electrical conditions, backup power usage, and solar adoption make practical protection choices important. Whether the load is a 1 ton AC, 1.5 ton AC, 2 ton AC, geyser, water pump, fridge, washing machine, solar inverter, or UPS-backed line, the main question is not just price in Pakistan but whether the product is doing the right job in the system.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThat is why CNC Electric Pakistan positions this model as part of a full product family rather than a one-off item. You can combine it with matching \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027\"\u003eDB boxes\u003c\/a\u003e, \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003ebreakers\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003esurge protectors\u003c\/a\u003e, and \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027\"\u003echangeover switches\u003c\/a\u003e depending on the site.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSelection Guide\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eAppliance \/ Load \/ Use Case\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eRecommended Rating \/ Variant\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSolar PV string protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eStandard DC MCB or fuse\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eBattery breaker is usually not necessary for small strings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eHybrid lithium battery bank\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eBattery breaker\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDesigned for higher-current battery side protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eNeed 80A DC battery line\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e80A variant\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eMatch actual cable and inverter\/battery design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eNeed 100A DC battery line\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e100A variant\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eCommon for medium battery bank feeders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eNeed 125A heavy battery line\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e125A variant\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eFor larger systems after full design review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Install\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eInstallation should always be done by a licensed electrician or qualified solar installer. Clean wiring, correct torque, proper cable size, and testing matter as much as the product itself.\u003c\/p\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eIsolate battery and inverter systems safely before any work.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eMount the breaker in the correct battery protection enclosure or panel space.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eWire positive and negative poles as required by the system design.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eTorque terminals correctly because loose DC connections create heat risk.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eCommission only after a qualified solar electrician verifies cable size, polarity, and fault level assumptions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis breaker does not protect against battery overcharging, which requires the battery system and BMS. It does not replace \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027\"\u003eDC SPD\u003c\/a\u003e for surge risk, does not fix reverse polarity errors, and does not protect AC circuits where \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003eAC breakers\u003c\/a\u003e are required.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eStandard DC MCB vs Battery Breaker vs DC MCCB\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eOption 1\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eOption 2\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eOption 3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eTypical use\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003ePV strings\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eBattery banks\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLarger heavy-duty DC circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eBreaking capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLower typical\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eHigher at 10kA\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eHigher-duty class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eCurrent range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLower \/ medium\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eUp to 125A here\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLarger system options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eResettable\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eBest buyer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eSolar string installer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eHybrid battery installer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLarger industrial \/ storage setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCNC vs Schneider and Local Brands\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eCNC\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSchneider\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eLocal Brands\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eTypical price in Pakistan\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eRs.2,500\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eUsually much higher\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eVaries but often inconsistent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eStandards \/ documented product line\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDefined branded family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003ePremium branded family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften unclear in low-end market stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eChannel dependent\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften limited or unclear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eValue for Pakistani buyers\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eStrong price-to-performance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003ePremium but expensive\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eCheaper-looking but riskier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eAvailability of matching accessories\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eYes across multiple collections\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDepends on range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften mixed products from many sellers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCross-Category Recommendations\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIf you are buying this product, also consider \u003ca href=\"\/products\/cnc-2-pole-mcb-dc-circuit-breakers-500v-ycb8-63pv\" style=\"color:#d42027\"\u003eDC 2P MCB\u003c\/a\u003e Rs.1,550, \u003ca href=\"\/products\/cnc-dc-1-pole-125a-mcb-circuit-breakers-500v-ycb8s-125pv\" style=\"color:#d42027\"\u003eDC 1P 125A\u003c\/a\u003e Rs.1,100, \u003ca href=\"\/products\/cnc-4-pole-mcb-dc-circuit-breakers-1000v-ycb8-63pv\" style=\"color:#d42027\"\u003eDC 4P 1000V\u003c\/a\u003e Rs.3,300, \u003ca href=\"\/products\/dc-mccb-125a-1000v-yem6\" style=\"color:#d42027\"\u003eDC MCCB 125A\u003c\/a\u003e Rs.4,000, \u003ca href=\"\/products\/cnc-2p-dc-spd-600v-surge-protection-devices-ycs6-c\" style=\"color:#d42027\"\u003eDC SPD 600V\u003c\/a\u003e Rs.2,900.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBrowse \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003eAC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027\"\u003eDC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027\"\u003eAC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027\"\u003eDC breaker collection\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027\"\u003eMCCBs\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003eAC SPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027\"\u003eDC SPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-regulator\" style=\"color:#d42027\"\u003evoltage regulators \/ stabilizers\u003c\/a\u003e, \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027\"\u003eRCCB \/ RCBO\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/solar-db-box-guide-everything-pakistan-installers-need-to-know\" style=\"color:#d42027\"\u003esolar DB guide\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003etypes of circuit breakers\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/mcb-size-chart-for-pakistan-pick-the-right-breaker-for-every-appliance\" style=\"color:#d42027\"\u003eMCB size chart for Pakistan\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/circuit-breaker-trip-curves-explained-b-c-and-d-curve-mcbs\" style=\"color:#d42027\"\u003etrip curves explained\u003c\/a\u003e, \u003ca href=\"\/blogs\/guides\/spd-full-form-what-is-surge-protection-device-why-pakistan-needs-it\" style=\"color:#d42027\"\u003eSPD full form guide\u003c\/a\u003e for a complete project-level view before final selection.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products from CNC Electric\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-2-pole-mcb-dc-circuit-breakers-500v-ycb8-63pv\" style=\"color:#d42027\"\u003eDC 2P MCB\u003c\/a\u003e — Rs.1,550\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-dc-1-pole-125a-mcb-circuit-breakers-500v-ycb8s-125pv\" style=\"color:#d42027\"\u003eDC 1P 125A\u003c\/a\u003e — Rs.1,100\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-4-pole-mcb-dc-circuit-breakers-1000v-ycb8-63pv\" style=\"color:#d42027\"\u003eDC 4P 1000V\u003c\/a\u003e — Rs.3,300\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/dc-mccb-125a-1000v-yem6\" style=\"color:#d42027\"\u003eDC MCCB 125A\u003c\/a\u003e — Rs.4,000\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-2p-dc-spd-600v-surge-protection-devices-ycs6-c\" style=\"color:#d42027\"\u003eDC SPD 600V\u003c\/a\u003e — Rs.2,900\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/collections\/solar-bundles\" style=\"color:#d42027\"\u003eSolar bundles\u003c\/a\u003e — Collection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the battery breaker price in Pakistan for this product?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product starts from Rs.2,500. Final selection depends on the chosen variant or system requirement. CNC Electric Pakistan also offers free delivery and a 5-year warranty.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWho should buy the DC 2 Pole 500V 125A Battery Breaker YCB1-125?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis model suits buyers in Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar who need a proper panel-mounted solution rather than a market workaround.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan a normal electrician install this?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eA licensed electrician or qualified solar installer should install it, because correct wiring, sizing, and testing matter more than the product alone.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eHow do I choose the right rating or variant?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose the variant according to actual load current, system voltage, cable size, and application. The selection guide above gives a starting point, but final sizing should be verified on site.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this better than cheap local market alternatives?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor serious installations, buyers usually prefer a defined product line, clearer specifications, and a 5-year warranty instead of inconsistent no-name market stock.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this replace every other protection device in the panel?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. Each product has a specific role. A complete system may also need MCBs, RCBOs, SPDs, voltage protectors, changeovers, ATS units, fuses, or DB boxes depending on the job. Pair with an \u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027\"\u003eaerosol fire extinguisher\u003c\/a\u003e for added panel safety.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this available across Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, CNC Electric Pakistan sells across Pakistan with common demand from Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhy buy from CNC Electric Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBecause buyers want practical price in Pakistan, coordinated related products, free delivery, and after-sales support instead of mixing random parts from different sources.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I compare this with other CNC products before ordering?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. Use the related products and collection links in this description to compare alternative ratings, premium upgrades, and matching protection accessories before placing the order.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor full system planning, compare the linked collections and guides above. CNC Electric Pakistan offers free delivery, coordinated product ranges, and a 5-year warranty. WhatsApp us at 0326-1111376.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"125A","offer_id":42324170768450,"sku":"YCB1-125","price":2500.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/DC_2P_125A_Circuit_Battery_Breakers_500V.webp?v=1755856853"},{"product_id":"cnc-4-pole-mccb-molded-case-circuit-breakers-ycm7","title":"AC 4 Pole MCCB 63A, 100A, 125A, 160A, 200A, 250A, 400A, 630A, 800A | Durable Electrical Protection","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.7;color:#222;max-width:820px\"\u003e\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:22px 0 8px;color:#1a1a1a\"\u003eCNC YCM7 Series 4 Pole MCCB -- 63A to 1250A\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;font-size:15px;line-height:1.7\"\u003eThe YCM7 is a molded case circuit breaker (MCCB) for three-phase AC power distribution. Available from 63A up to 1250A, it covers everything from small commercial panels to heavy industrial main switchgear.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 12px;font-size:15px;line-height:1.7\"\u003eMCCBs handle higher fault currents than MCBs and have adjustable trip settings, making them the standard choice for main breakers in factories, building risers, and transformer LT panels in Pakistan. The YCM7 frame sizes scale from 100 frame (63A-125A) through 250, 400, 630, and 800 frames up to 1250A.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:22px 0 8px;color:#1a1a1a\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 18px;font-size:14px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003eYCM7 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003ePoles\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003e4 Pole (3P+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eCurrent Ratings\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003e63A, 100A, 125A, 160A, 200A, 250A, 400A, 630A, 800A, 1000A, 1250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eRated Voltage\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003eAC 400V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eInsulation Voltage\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003e800V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eBreaking Capacity\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003e35kA - 50kA (varies by frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eTrip Unit\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003eThermal-magnetic, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px 12px;background:#f5f5f5;border:1px solid #ddd;font-weight:600;width:40%\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd\"\u003ePanel mount (DIN rail adapter available for smaller frames)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:22px 0 8px;color:#1a1a1a\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin:8px 0 14px 18px;padding:0\"\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eMain incoming breaker for commercial and industrial buildings\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eTransformer LT side protection (WAPDA\/K-Electric supply)\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eGenerator output protection -- 100 kVA to 1000 kVA gensets\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eSolar system AC side main breaker for large PV plants\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;line-height:1.6\"\u003eMotor control center (MCC) feeder breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:20px;font-weight:700;margin:22px 0 8px;color:#1a1a1a\"\u003eSelection Guide\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;font-size:15px;line-height:1.7\"\u003ePick the MCCB rating at 1.25x your expected full-load current. For a 200A load, use the 250A MCCB. For motor loads with high inrush, size up one step. The adjustable thermal trip lets you fine-tune the overload setting between 0.8x and 1.0x of the rated current.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"63A","offer_id":42460874702914,"sku":null,"price":6800.0,"currency_code":"PKR","in_stock":true},{"title":"100A","offer_id":42324171292738,"sku":"YCM7","price":7200.0,"currency_code":"PKR","in_stock":true},{"title":"125A","offer_id":42324171325506,"sku":"YCM7","price":7200.0,"currency_code":"PKR","in_stock":true},{"title":"160A","offer_id":42324171358274,"sku":"YCM7","price":10500.0,"currency_code":"PKR","in_stock":true},{"title":"200A","offer_id":42324171391042,"sku":"YCM7","price":14300.0,"currency_code":"PKR","in_stock":true},{"title":"250A","offer_id":42324171423810,"sku":"YCM7","price":14300.0,"currency_code":"PKR","in_stock":true},{"title":"400A","offer_id":42324171456578,"sku":"YCM7","price":41000.0,"currency_code":"PKR","in_stock":true},{"title":"630A","offer_id":42324171489346,"sku":"YCM7","price":50500.0,"currency_code":"PKR","in_stock":true},{"title":"800A","offer_id":42444679675970,"sku":"YCM7","price":73000.0,"currency_code":"PKR","in_stock":true},{"title":"1000A","offer_id":42460874735682,"sku":null,"price":122400.0,"currency_code":"PKR","in_stock":true},{"title":"1250A","offer_id":42460874768450,"sku":null,"price":145900.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/4_Pole_MCCB_Molded_Case_Circuit_Breakers.webp?v=1755857576"},{"product_id":"cnc-3-pole-mccb-molded-case-circuit-breakers-ycm7","title":"AC 3 Pole MCCB 32A, 40A, 63A, 100A, 125A, 160A, 200A, 250A, 400A, 630A, 800A, 1000A, 1250A | Reliable Protection","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eLooking for an AC MCCB 3 pole breaker price in Pakistan for a commercial panel, industrial feeder, motor application, or building main distribution board? This CNC Electric YCM7 molded case circuit breaker is built for users who need more serious protection than a small MCB can provide. In Pakistan, once a circuit moves into larger motors, heavier feeders, generator-backed panels, or commercial distribution work, an \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB breaker\u003c\/a\u003e becomes the more practical choice. For electricians, panel builders, facility managers, and industrial users, this 3 pole MCCB gives a stronger protection class for overload, short circuit, and under-voltage related panel design needs.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e3 pole molded case circuit breaker for AC distribution and motor-protection applications where a normal small breaker is not enough.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eFull local selling range from 32A to 1250A across six YCM7 frame groups — covers light commercial boards all the way to heavy industrial incoming mains.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eDesigned for AC 50Hz networks with rated insulation voltage 800V according to the live product description.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eRated voltage values are AC400V \/ AC690V across all frame groups.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eThermo-magnetic automatic tripping device gives it practical protection logic for overload and short-circuit faults.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eVertical and horizontal installation are both supported, which helps in real panel-building work.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eStrong short-circuit interrupting ability and low arc-energy behavior for safer industrial and commercial panel use.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eBuilt to \u003ca href=\"https:\/\/webstore.iec.ch\/publication\/6028\" style=\"color:#d42027;\" target=\"_blank\" rel=\"noopener nofollow\"\u003eIEC 60947-2\u003c\/a\u003e molded-case breaker context for low-voltage switchgear protection devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eAC 3 Pole Molded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePhase \/ Poles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e3 Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eCurrent Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e32A, 40A, 63A, 100A, 125A, 160A, 200A, 250A, 400A, 630A, 800A, 1000A, 1250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRated Network Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eAC 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRated Voltage Ue\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eAC400V \/ AC690V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRated Insulation Voltage Ui\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eAC800V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eAutomatic Tripping Device\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eThermo-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eInstallation Direction\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eVertical or horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eFrame Groups\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-125S, YCM7-160S, YCM7-250S, YCM7-400S\/M, YCM7-630M, YCM7-800M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eShort-Circuit Capacity (kA)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eAC400V: 15\/8, 25\/18, 35\/25, 50\/35 across the frame groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eProtection Scope\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOverload, short circuit, and under-voltage in distribution and motor applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePrice Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.4,400 (32A) — Rs.87,000 (1250A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range \u0026amp; Prices\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eAmp\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eFrame\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eTypical Use\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-125S\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eLight branch feeder, small commercial circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.4,400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e40A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-125S\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eLight branch feeder, workshop sub-feeder\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.4,400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e63A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-125S\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eLight commercial feeder, small motor circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.4,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e100A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-125S\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eCommercial sub-distribution feeder\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.5,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e125A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-125S\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eCommercial feeder, generator-backed panel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.5,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e160A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-160S\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eLarger commercial feeder, workshop panel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.8,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e200A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-250S\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eIndustrial feeder, heavier motor circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.11,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e250A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-250S\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eIndustrial feeder, large motor panel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.11,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e400A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-400S\/M\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eLarge industrial feeder, incoming sub-main\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.30,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e630A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-630M\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eHeavy industrial feeder, major distribution\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.40,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e800A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-800M\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eHeavy industrial incoming, major service\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.53,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e1000A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-800M\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eIncoming main, large service protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.87,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003e1250A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eYCM7-800M\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eTop-end incoming main, service protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eRs.87,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eCommercial building main and sub-distribution boards where feeder current has moved beyond normal MCB territory.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eIndustrial panels in Lahore, Karachi, or Faisalabad where motor circuits, process loads, and larger feeders need molded-case protection.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eSolar and backup-power related AC distribution panels where the incoming or outgoing circuit is too heavy for a small modular breaker.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eGenerator and ATS panels where larger current paths need stronger breaker logic and clearer short-circuit performance than MCB-class devices.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eMotor-protection jobs where overload, short-circuit, and under-voltage protection are relevant to the system design.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003ePanels that also need \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003eVoltage Protectors\u003c\/a\u003e, and organized \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB or enclosure planning\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSizing \/ Selection Guide\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose this YCM7 range when the circuit needs a molded-case breaker rather than a small MCB. The main checks are feeder current, fault level, whether the load is distribution or motor-focused, and whether the breaker is being used as an incoming main, outgoing feeder, or machine supply breaker.\u003c\/p\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong style=\"font-size:15px;\"\u003e32A–125A\u003c\/strong\u003e — smaller commercial boards, light industrial feeders, and compact power-distribution jobs. Rs.4,400–Rs.5,500.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong style=\"font-size:15px;\"\u003e160A–250A\u003c\/strong\u003e — heavier commercial feeders, workshop panels, mid-size motor circuits. Rs.8,000–Rs.11,000.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong style=\"font-size:15px;\"\u003e400A–630A\u003c\/strong\u003e — large industrial feeders, heavy-duty motor circuits, major distribution sub-mains. Rs.30,000–Rs.40,000.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong style=\"font-size:15px;\"\u003e800A–1250A\u003c\/strong\u003e — incoming mains, heavy-duty service protection, major panel incomers. Rs.53,000–Rs.87,000.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\n\u003cstrong style=\"font-size:15px;\"\u003eBuild the full panel correctly\u003c\/strong\u003e with the right \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e, contactor or overload logic where relevant, and proper cable sizing instead of sizing the breaker in isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eAC MCCB vs Alternatives — Why CNC?\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor Pakistani buyers, the real comparison is not just MCCB brand versus MCCB brand. It is MCCB versus undersized MCB practice, and proper feeder protection versus overloading a modular solution that was never meant for the job. That is why a molded-case breaker like this stays important in serious panel work.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eBuying Factor\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eCNC Electric\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eSchneider\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eABB\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eChint\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6;\"\u003eClopal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBest fit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eCommercial and industrial feeder protection with broad 32A–1250A current coverage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePremium consultant-led ecosystems\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eHigher-end project-led ecosystems\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eMainstream branded alternative\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBudget-led local comparison point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003ePrice transparency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eAll 13 amp ratings clearly priced: Rs.4,400–Rs.87,000\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOften quote-based, higher cost\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOften quote-based, higher cost\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eMid-market transparency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOften chosen mainly on price\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eProtection class\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eThermo-magnetic molded-case protection, 15–50kA breaking across frames\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOften chosen for premium-brand confidence\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eOften chosen for premium-brand confidence\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eStrong commercial relevance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eSometimes treated too much as a price item\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eWhy buyer chooses it\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBecause it offers real MCCB feeder protection with published per-amp pricing and IEC 60947-2 compliance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBecause the project is premium-brand driven\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBecause the project is premium-brand driven\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBecause it balances brand familiarity and practicality\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6;\"\u003eBecause the decision is mainly cost-led\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eIt is not an \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e and does not replace surge protection for sensitive panels or electronics.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eIt is not a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003eVoltage Protector\u003c\/a\u003e and should not be used as the only answer for unstable mains conditions.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eIt does not fix poor cable sizing, weak busbar design, bad earthing, or careless panel workmanship.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eIt should not be selected only by current rating without checking the actual fault level and panel design conditions.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eIt does not replace overload relays or contactor logic where a motor starter arrangement needs separate coordinated devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n\u003col style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eConfirm the circuit is genuinely a 3-phase application and that the selected current rating matches the feeder or motor duty.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eInstall the MCCB inside a properly designed panel with correct cable lugs, busbar spacing, and enclosure support.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eUse the correct incoming and outgoing conductor size so the breaker is not paired with undersized cabling.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eMount vertically or horizontally according to the panel layout — both installation directions are supported.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eCommission the panel under controlled conditions and verify trip coordination with the rest of the protective devices.\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003eFinish the installation with \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e, proper enclosure planning, and the \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027;\"\u003eFire Extinguisher Guide\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCross-Category Links\u003c\/h2\u003e\n\u003cul style=\"font-size:15px;line-height:1.6;margin:0 0 12px 20px;padding:0;\"\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB Breakers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027;\"\u003eCircuit Breakers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027;\"\u003eAC Breakers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003eMagnetic Contactors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSurge Protection Devices\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003eVoltage Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB Boxes\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/blogs\/news\/ac-mccb-breaker-complete-guide-to-moulded-case-circuit-breaker-features-applications\" style=\"color:#d42027;\"\u003eMCCB Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of Circuit Breakers Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-size:15px;line-height:1.6;margin-bottom:8px;\"\u003e\u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027;\"\u003eFire Extinguisher Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is an AC 3 pole MCCB breaker?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eIt is a molded case circuit breaker used on three-phase AC systems where the circuit current and fault conditions are heavier than normal small-breaker applications.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the 3 pole MCCB price in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eThe YCM7 3-pole MCCB is priced from Rs.4,400 for the 32A and 40A variants up to Rs.87,000 for the 1000A and 1250A frames. See the full variant table above for each amp rating.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan this MCCB be used for motors as well as power distribution?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eYes. It is used for both electric-energy distribution and motor protection against overload, short circuit, and under-voltage faults.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat voltage class does this YCM7 MCCB support?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eAC400V \/ AC690V rated voltage and AC800V insulation voltage across all frame groups.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this better than using an MCB on a large feeder?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eYes. Once the load and panel duty move beyond small-breaker territory, an MCCB is usually the more correct protection class for larger feeders.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan it be installed both vertically and horizontally?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eYes. Both installation directions are supported by this breaker.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this MCCB include surge or voltage protection?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eNo. It is a molded-case breaker. Surge control still requires \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e, and unsafe voltage management may still need a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003eVoltage Protector\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat short-circuit breaking capacity does it have?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eShort-circuit capacity ranges from 15\/8 kA through 50\/35 kA at AC400V, depending on the frame group (YCM7-125S through YCM7-800M).\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eHow do I choose the right current rating in this MCCB family?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eChoose it from the actual feeder current, motor duty if relevant, cable size, and overall panel design. Do not choose only by the visible price or by copying a nearby project.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat should I add with this MCCB for a better panel?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eA better-finished panel usually includes the right \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003econtactors\u003c\/a\u003e where relevant, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;\"\u003evoltage protection\u003c\/a\u003e, sound enclosure planning, and nearby \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;\"\u003epanel fire protection\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px;\"\u003eIf you need a practical 3 pole MCCB in Pakistan for real feeder and motor protection work, this CNC Electric YCM7 line is a strong commercial option. It gives you molded-case protection logic, clear per-amp pricing from Rs.4,400 to Rs.87,000 across 13 current ratings, and the kind of flexibility that suits commercial and industrial panel work far better than forcing an undersized breaker approach. For stock confirmation or help pairing it with contactors, SPD, and the right enclosure, contact CNC Electric Pakistan on WhatsApp before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"32A","offer_id":42324171522114,"sku":"YCM7","price":4400.0,"currency_code":"PKR","in_stock":true},{"title":"40A","offer_id":42324171554882,"sku":"YCM7","price":4400.0,"currency_code":"PKR","in_stock":true},{"title":"63A","offer_id":42324171587650,"sku":"YCM7","price":4600.0,"currency_code":"PKR","in_stock":true},{"title":"100A","offer_id":42324171620418,"sku":"YCM7","price":5500.0,"currency_code":"PKR","in_stock":true},{"title":"125A","offer_id":42444670664770,"sku":"YCM7","price":5500.0,"currency_code":"PKR","in_stock":true},{"title":"160A","offer_id":42324171653186,"sku":"YCM7","price":8000.0,"currency_code":"PKR","in_stock":true},{"title":"200A","offer_id":42324171685954,"sku":"YCM7","price":11000.0,"currency_code":"PKR","in_stock":true},{"title":"250A","offer_id":42444670697538,"sku":"YCM7","price":11000.0,"currency_code":"PKR","in_stock":true},{"title":"400A","offer_id":42324171718722,"sku":"YCM7","price":30000.0,"currency_code":"PKR","in_stock":true},{"title":"630A","offer_id":42324171751490,"sku":"YCM7","price":40000.0,"currency_code":"PKR","in_stock":true},{"title":"800A","offer_id":42444670730306,"sku":"YCM7","price":53000.0,"currency_code":"PKR","in_stock":true},{"title":"1000A","offer_id":42444670763074,"sku":"YCM7","price":87000.0,"currency_code":"PKR","in_stock":true},{"title":"1250A","offer_id":42444670795842,"sku":"YCM7","price":87000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/3_Pole_MCCB_Molded_Case_Circuit_Breakers.webp?v=1755857684"},{"product_id":"cnc-4-pole-mcb-dc-circuit-breakers-1000v-ycb8-63pv","title":"DC 4 Pole MCB 1000V | Solar PV Breaker","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eDC MCB 4 pole 1000V price in Pakistan matters when a solar installer needs a breaker that actually matches DC string voltage instead of a normal AC breaker forced into a PV job. This CNC Electric listing is sold locally from Rs.3,300 with selectable 16A, 20A, 32A and 63A options on a 4-pole DC breaker page. For rooftop solar, combiner boxes, battery-linked DC distribution and selected industrial DC circuits, it gives one practical benefit: you get DC-side overload, short-circuit and isolation protection in a format made for photovoltaic work instead of improvised panel wiring.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis is not the right breaker for every job. If the system current is much higher, you move up to a \u003ca href=\"\/collections\/dc-mccb-breaker\" style=\"color:#d42027;font-weight:700\"\u003eDC MCCB breaker\u003c\/a\u003e. If the risk is lightning or switching surge damage, you still need a proper \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027;font-weight:700\"\u003eDC SPD\u003c\/a\u003e. If the installer is trying to use a normal AC breaker on a solar string, that is the wrong comparison from the start. This page is for the buyer who needs a real \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027;font-weight:700\"\u003eDC breaker\u003c\/a\u003e for a 1000V-class solar or DC distribution setup and wants a 4-pole format with practical ampere choices.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e4-pole DC MCB format for DC circuits up to 1000V on the local sales page.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eSelectable local current options: 16A, 20A, 32A and 63A.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eLocal page states overload, short-circuit and isolation protection for photovoltaic, industrial, civil and communication systems.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e6kA breaking-capacity class is published on the local product page.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eStandard DIN-rail mounting helps in \u003ca href=\"\/collections\/solar-bundles\" style=\"color:#d42027;font-weight:700\"\u003esolar protection panels\u003c\/a\u003e and DC combiner layouts.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eOfficial family reference supports auxiliary contact, alarm contact and shunt-release compatibility in the wider breaker family.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eA better fit for solar strings and DC feeders than forcing a normal \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027;font-weight:700\"\u003eAC breaker\u003c\/a\u003e into a DC job.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLocal sale product\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDC 4 Pole MCB 1000V, 16A \/ 20A \/ 32A \/ 63A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLocal displayed price\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.3,300 on the currently displayed local selector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNumber of poles\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e4 Pole\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated working voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1000V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated insulation voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1200V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated impulse voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e4kV\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUltimate breaking capacity\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e6kA class on the local page\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOperating breaking capacity\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIcs = 100% of Icu on local page\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTripping type \/ curve\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThermomagnetic, B \/ C \/ K family options shown on local page\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMechanical life\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e20,000 operations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eElectrical life\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePV: 1500 \/ PVn: 300 on local page\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWorking temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e-35°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStorage temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e-40°C to +85°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProtection degree\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eInstallation method\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDIN35 standard rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWiring capacity\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e2.5-25mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTerminal torque\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3.5 N·m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStandard\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis description uses only data published on the live product page. Exact selector-by-selector prices for all ampere options, full dimensional drawing, accessory part numbers and local wiring diagram details are not currently listed in a clean local sales format and have not been guessed.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range and Price Guide\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eAmp option\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePoles\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eVoltage\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBest fit\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrice note\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e16A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e4 Pole\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1000V DC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLighter PV string current and smaller DC feeders\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eConfirm on live selector; page currently displays Rs.3,300\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e20A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e4 Pole\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1000V DC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCommon solar string and combiner current band\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eConfirm on live selector; page currently displays Rs.3,300\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e32A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e4 Pole\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1000V DC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHeavier DC feeder duty and selected combiner circuits\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eConfirm on live selector; page currently displays Rs.3,300\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e63A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e4 Pole\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1000V DC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUpper end of the listed family for larger DC branch circuits\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eConfirm on live selector; page currently displays Rs.3,300\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications — Where to Use This DC MCB\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis breaker belongs on the DC side of the system. In Lahore rooftop solar work, installers commonly need a proper breaker between the string and the combiner or between the DC source and a protected enclosure. In Karachi, where heat, salt air and switchgear misuse already create enough problems, using the right \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027;font-weight:700\"\u003eDC breaker\u003c\/a\u003e is far better than forcing an AC breaker into a PV job. In Faisalabad factory-roof solar and process-power applications, a 4-pole 1000V DC breaker can fit combiner-style layouts, string grouping, battery-linked feeders and selected DC distribution points where dependable isolation matters.\u003c\/p\u003e\n\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eApplication\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRecommended use\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy this breaker fits\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSolar string isolation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse on a properly designed PV DC side\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1000V DC class and 4-pole format suit PV distribution logic better than AC protection gear\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCombiner box protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse alongside \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027;font-weight:700\"\u003eDC SPD\u003c\/a\u003e and fuse\/isolator strategy where needed\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eProvides DC-side overload and short-circuit protection in a DIN-rail format\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBattery-linked DC feeder\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse only where voltage and current match the design envelope\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBetter matched to DC duty than a normal AC MCB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTelecom or communication DC panel\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse where the DC distribution design calls for miniature breaker protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThe local page itself lists communication systems as a target use\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIndustrial DC auxiliary circuits\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse in properly engineered DC distribution sections\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThe local product page lists industrial and civil DC systems among the intended applications\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Choose the Right Amp Rating\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eDo not choose the breaker only by the biggest amp number. Match it to the conductor, the expected DC current, the combiner design and the fault-clearing logic of the system. A bigger ampere rating is not automatically safer. It can reduce protection if the wiring and source current do not justify it. If the design has high fault energy or current levels above miniature-breaker territory, move up to a proper \u003ca href=\"\/collections\/dc-mccb-breaker\" style=\"color:#d42027;font-weight:700\"\u003eDC MCCB\u003c\/a\u003e instead of stretching a small breaker beyond its role.\u003c\/p\u003e\n\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eSystem condition\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eLikely choice\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSmall PV string current and lighter conductor size\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e16A or 20A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCloser to common string-level protection ranges\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHeavier combiner or DC branch current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e32A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCommon step when current rises above lighter string-protection bands\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUpper-end miniature DC feeder need\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e63A\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHighest listed current on the local page\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHigh-current DC distribution beyond miniature-breaker comfort\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUse DC MCCB instead\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMiniature DC breakers are not the answer for every larger DC panel\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eDC MCB vs Alternatives — Why CNC?\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePoint\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eCNC DC MCB 4 Pole 1000V\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eGeneric AC breaker used on DC\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eDC MCCB\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMain purpose\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMiniature DC-side protection and isolation for PV and DC systems\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUsually the wrong device class for true DC duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLarger DC distribution and higher-current jobs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eVoltage match\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1000V DC on local page\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOften unsuitable or unsafe as a DC substitute\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBetter for heavier DC voltage\/current design envelopes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePanel footprint\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCompact DIN-rail format\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMay look compact but the duty mismatch is the real issue\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLarger physical footprint\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9f9f9\"\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWhen to choose it\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWhen you need a real 1000V-class DC breaker in miniature format\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDo not choose this route for proper PV design\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWhen miniature-breaker size or current range is no longer enough\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product does not replace a \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027;font-weight:700\"\u003eDC SPD\u003c\/a\u003e, a correctly sized \u003ca href=\"\/collections\/fuses\" style=\"color:#d42027;font-weight:700\"\u003esolar fuse\u003c\/a\u003e, or a proper \u003ca href=\"\/collections\/dc-isolator\" style=\"color:#d42027;font-weight:700\"\u003eDC isolator\u003c\/a\u003e where the system design requires them. It does not fix poor combiner-box layout, wrong cable sizing, loose lugs, water ingress, or a bad inverter-side design. It is also not the right answer for every high-current DC panel. Some jobs belong to a DC MCCB, not to a miniature breaker.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor a full solar or DC protection setup, pair the breaker with the right \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027;font-weight:700\"\u003eDC SPD\u003c\/a\u003e, a suitable \u003ca href=\"\/collections\/solar-bundles\" style=\"color:#d42027;font-weight:700\"\u003esolar protection bundle\u003c\/a\u003e, the correct \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;font-weight:700\"\u003eDB box\u003c\/a\u003e, and if the system includes voltage-sensitive AC loads, add a proper \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;font-weight:700\"\u003evoltage protector\u003c\/a\u003e on the AC side as well.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n  \u003col style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount the breaker on a proper DIN rail inside a suitably rated DC enclosure or combiner box.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eConfirm the DC voltage class, current class, cable size and protection coordination before landing any wires.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eUse correct conductor size within the published wiring range and tighten terminals correctly to avoid hot joints.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eCoordinate the breaker with upstream and downstream DC protection such as fuses, isolators and \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027;font-weight:700\"\u003eDC surge protection\u003c\/a\u003e.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eBefore energizing, verify polarity logic, enclosure sealing, and the full DC path from array to combiner or distribution section.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n  \u003cdiv style=\"margin-top:25px;padding:15px;background:#f9f9f9;border:1px solid #e0e0e0;border-radius:5px;\"\u003e\n    \u003cp style=\"font-size:16px;font-weight:700;margin-bottom:10px;\"\u003eComplete Your Electrical Setup\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027;\"\u003eDC SPD\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🔌 \u003ca href=\"\/collections\/dc-isolator\" style=\"color:#d42027;\"\u003eDC Isolators\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📦 \u003ca href=\"\/collections\/solar-bundles\" style=\"color:#d42027;\"\u003eSolar DB Bundles\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🧰 \u003ca href=\"\/collections\/fuses\" style=\"color:#d42027;\"\u003eSolar Fuses\u003c\/a\u003e\u003c\/p\u003e\n    \u003cp style=\"font-size:15px;margin-bottom:0;\"\u003e📖 \u003ca href=\"\/blogs\/news\/dc-breaker-complete-guide-to-dc-circuit-breakers-for-solar-battery-low-voltage-systems\" style=\"color:#d42027;\"\u003eGuide: DC Breaker Complete Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px\"\u003e⚡ \u003ca href=\"\/collections\/dc-fuse\" style=\"color:#d42027\"\u003eDC Fuses\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027;font-weight:700\"\u003eDC breakers\u003c\/a\u003e for other solar and battery-side protection options.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/dc-mccb-breaker\" style=\"color:#d42027;font-weight:700\"\u003eDC MCCB breakers\u003c\/a\u003e when current level or panel duty is beyond miniature-breaker range.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027;font-weight:700\"\u003eDC SPDs\u003c\/a\u003e for lightning and switching surge protection on PV strings and DC feeders.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/dc-isolator\" style=\"color:#d42027;font-weight:700\"\u003eDC isolators\u003c\/a\u003e when manual isolation is required by the design.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/solar-bundles\" style=\"color:#d42027;font-weight:700\"\u003eSolar bundles\u003c\/a\u003e for a more complete pre-matched protection package.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;font-weight:700\"\u003eDB boxes\u003c\/a\u003e to house the DC protection assembly correctly.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003eSPD\u003c\/a\u003e on the AC side when inverter-fed loads also need surge protection.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;font-weight:700\"\u003eFire extinguisher products\u003c\/a\u003e as the final panel-safety add-on.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/solar-db-box-guide-everything-pakistan-installers-need-to-know\" style=\"color:#d42027;\"\u003eSolar DB Box Guide\u003c\/a\u003e for installer-side planning.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e\n\u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of Circuit Breakers Guide\u003c\/a\u003e for broader breaker selection.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e1. What is a DC 4 pole MCB used for in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt is used for DC-side overload, short-circuit and isolation protection in solar photovoltaic systems, battery-linked DC circuits and selected communication or industrial DC panels.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e2. What is the price of this DC 4 pole 1000V breaker in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe current local product page displays Rs.3,300. Because the page has selectable 16A, 20A, 32A and 63A options, confirm the live selector before checkout if you need exact variant pricing.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e3. Is this a DC MCB or a DC MCCB?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis product is a DC MCB. It is for miniature-breaker duty. If the system current and fault-duty are higher, move to a \u003ca href=\"\/collections\/dc-mccb-breaker\" style=\"color:#d42027;font-weight:700\"\u003eDC MCCB\u003c\/a\u003e.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e4. Can I use a normal AC breaker instead of this DC breaker?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThat is not the right approach for a real PV DC system. DC duty and arc behavior are different. Use a proper DC breaker designed for the voltage and current involved.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e5. What ampere options are available on the local page?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe local page currently shows 16A, 20A, 32A and 63A selector options on the 4-pole 1000V DC breaker listing.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e6. Does this breaker protect against solar surges or lightning?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. Breakers and SPDs do different jobs. Use a \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027;font-weight:700\"\u003eDC SPD\u003c\/a\u003e for surge protection.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e7. Is this suitable for combiner boxes?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, it can suit combiner-box and DC distribution work where the voltage and current match the design and the rest of the protection scheme is correct.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003e8. Where can I buy this DC MCB in Pakistan?\u003c\/h3\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYou can buy it from CNC Electric Pakistan through the live product page and get help on the correct breaker, fuse, isolator and SPD combination before ordering.\u003c\/p\u003e\n\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis 4-pole 1000V DC MCB is the right buy when you need a real photovoltaic DC breaker in miniature format instead of a forced AC workaround. It suits solar strings, combiner-box protection, battery-linked DC feeders and selected communication or industrial DC circuits when the design stays inside its published class. For stock status, selector confirmation and help choosing the correct \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027;font-weight:700\"\u003eDC SPD\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-isolator\" style=\"color:#d42027;font-weight:700\"\u003eisolator\u003c\/a\u003e or \u003ca href=\"\/collections\/dc-mccb-breaker\" style=\"color:#d42027;font-weight:700\"\u003eDC MCCB\u003c\/a\u003e, contact CNC Electric Pakistan on WhatsApp \u003ca href=\"https:\/\/wa.me\/923261111376\" style=\"color:#d42027;font-weight:700\"\u003e0326-1111376\u003c\/a\u003e. Orders above Rs.10,000 qualify for free delivery.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"20A","offer_id":42324172046402,"sku":"YCB8-63PV","price":3400.0,"currency_code":"PKR","in_stock":true},{"title":"32A","offer_id":42392306942018,"sku":"YCB8-63PV","price":3400.0,"currency_code":"PKR","in_stock":false},{"title":"63A","offer_id":42404089331778,"sku":"YCB8-63PV","price":3400.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/4P_63A_DC_MCB_Circuit_Breaker_1000V.webp?v=1755857009"},{"product_id":"cnc-2-pole-mcb-dc-circuit-breakers-500v-ycb8-63pv","title":"DC 2 Pole MCB 500V | Solar PV Breaker","description":"\u003cp\u003e\u003cstrong\u003eDC 2 Pole MCB 500V\u003c\/strong\u003e is the core safety breaker used on the DC side of solar systems to disconnect and protect strings from overcurrent and short-circuit faults. The CNC Electric \u003cstrong\u003eYCB8-63PV\u003c\/strong\u003e is built for solar PV use, DIN-rail mounting, and comes in 4 real variants on this page: \u003cstrong\u003e20A, 32A, 40A, and 63A — all at Rs.1,600\u003c\/strong\u003e. It is a practical solar breaker for homes and commercial sites in Pakistan where solar power feeds inverters running ACs, fridges, pumps, and UPS charging.\u003c\/p\u003e\n\n\u003ch2\u003eQuick Specs\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eYCB8-63PV DC 2 Pole MCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2 Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent ratings (this page)\u003c\/td\u003e\n\u003ctd\u003e20A, 32A, 40A, 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Characteristic\u003c\/td\u003e\n\u003ctd\u003eC curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSolar PV DC overcurrent and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eVariants \u0026amp; Prices (Live on Shopify)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003cth\u003eTypical use\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eSmall residential PV strings\u003c\/td\u003e\n\u003ctd\u003eRs.1,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eStandard residential strings\u003c\/td\u003e\n\u003ctd\u003eRs.1,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eLarger rooftop strings\u003c\/td\u003e\n\u003ctd\u003eRs.1,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003eHigh-current strings (design-verified)\u003c\/td\u003e\n\u003ctd\u003eRs.1,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll four ratings are the same price on this page. Pick the variant that matches your string current, cable size, and inverter manufacturer recommendation — not by guessing bigger is safer.\u003c\/p\u003e\n\n\u003ch2\u003eWhat This Product Does\u003c\/h2\u003e\n\u003cp\u003eThis DC circuit breaker is installed between the solar PV side and the rest of the system so a fault on a string can be isolated quickly and safely. Buyers searching for \u003cem\u003edc breaker, dc mcb, solar panel breaker, 500v dc breaker, or pv breaker\u003c\/em\u003e want a proper breaker for solar wiring rather than an improvised disconnect. MCB stands for Miniature Circuit Breaker.\u003c\/p\u003e\n\u003cp\u003eUse this model when you need breaker-style protection on a 500V DC solar string. It is a better fit than an AC breaker because DC arcs behave differently, and this device is designed specifically for solar PV duty.\u003c\/p\u003e\n\n\u003ch2\u003eWhen You Need This DC MCB Instead of Other Devices\u003c\/h2\u003e\n\u003cp\u003eChoose this DC MCB when your main requirement is overcurrent and short-circuit interruption on a DC string. It is resettable — different from a fuse (which must be replaced after operation) and different from a DC isolator (which is mainly for isolation, not overcurrent protection). It is also not a DC SPD (surge) or a voltage protector.\u003c\/p\u003e\n\n\u003ch2\u003eRating Selection Guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSolar Setup\u003c\/th\u003e\n\u003cth\u003eRecommended\u003c\/th\u003e\n\u003cth\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall residential PV strings\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eCommon for smaller panel string currents in home systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard rooftop string\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003eTypical middle choice for residential solar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarger rooftop string\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eWhere array current and cable design need more headroom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVery high-current string\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003eOnly when system calculation and cable size justify it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery-side high current switching\u003c\/td\u003e\n\u003ctd\u003eSee DC 2P 500V 125A battery breaker\u003c\/td\u003e\n\u003ctd\u003eThis page tops out at 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eActual sizing must be based on module Isc, string design, cable ampacity, ambient temperature, and inverter manufacturer recommendations. Oversizing reduces protection quality; undersizing causes nuisance tripping in hot weather.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eMount the breaker on a DIN rail inside a suitable solar DB or DC protection enclosure.\u003c\/li\u003e\n\u003cli\u003eConfirm the system voltage and breaker rating before making any connection.\u003c\/li\u003e\n\u003cli\u003eConnect positive and negative string conductors exactly per the system design and labelling.\u003c\/li\u003e\n\u003cli\u003eTighten terminals correctly and keep cable dressing neat to reduce heat build-up.\u003c\/li\u003e\n\u003cli\u003eBefore energising, test continuity, polarity, insulation, and operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp\u003eThis breaker protects against overcurrent and short circuit on DC solar strings only. It does not protect against lightning surges — use a \u003ca href=\"\/collections\/dc-spd\"\u003eDC SPD\u003c\/a\u003e. It does not protect against earth leakage — that is handled by RCD\/RCBO strategy in the system design. It is not a fuse replacement in every design and not an automatic transfer switch.\u003c\/p\u003e\n\n\u003ch2\u003eCNC vs Schneider and Local Brands\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eCNC\u003c\/th\u003e\n\u003cth\u003eSchneider\u003c\/th\u003e\n\u003cth\u003eLocal Brands\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrice in Pakistan\u003c\/td\u003e\n\u003ctd\u003eRs.1,600\u003c\/td\u003e\n\u003ctd\u003eUsually notably higher\u003c\/td\u003e\n\u003ctd\u003eLower upfront, quality varies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolar-specific DC use\u003c\/td\u003e\n\u003ctd\u003eDesigned for solar PV DC\u003c\/td\u003e\n\u003ctd\u003eStrong reputation, premium budget\u003c\/td\u003e\n\u003ctd\u003eSpec matching often unclear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard reference\u003c\/td\u003e\n\u003ctd\u003eIEC 60947\u003c\/td\u003e\n\u003ctd\u003eIEC-compliant ranges\u003c\/td\u003e\n\u003ctd\u003eNot always clearly documented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5-year\u003c\/td\u003e\n\u003ctd\u003eDepends on channel\u003c\/td\u003e\n\u003ctd\u003eOften 1 year or unclear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/cnc-1000v-dc-fuse-holder-fuse-rt18-32\"\u003eDC Fuse Holder YCF8\u003c\/a\u003e — Rs.450\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/dc-spd\"\u003eDC SPD 1000V\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/dc-isolator\"\u003eDC Isolator\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dc-4-pole-mcb-miniature-circuit-breaker-1500v-32a\"\u003eDC 4P MCB 1500V\u003c\/a\u003e — Rs.3,800\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the price?\u003c\/strong\u003e\u003cbr\u003eRs.1,600 for any of the 20A, 32A, 40A, or 63A variants on this page.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich ratings are actually available?\u003c\/strong\u003e\u003cbr\u003eThis page sells four real variants: 20A, 32A, 40A, and 63A. Other ratings are not stocked on this listing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolar breaker or AC breaker?\u003c\/strong\u003e\u003cbr\u003eSolar breaker. Use only on the DC side of the PV system, not as a substitute for AC breakers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich amp should I choose?\u003c\/strong\u003e\u003cbr\u003eBased on string current, cable size, design margin, and inverter manufacturer recommendations. Common home systems use 20A or 32A, but final sizing must be calculated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it replace a DC fuse?\u003c\/strong\u003e\u003cbr\u003eNot in every design. A breaker is resettable; a fuse is one-time. Some systems use both.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I still need a DC SPD?\u003c\/strong\u003e\u003cbr\u003eYes if surge protection is required — this breaker does not stop lightning-related surges.\u003c\/p\u003e\n\n\u003cp\u003eFor a complete solar protection setup, browse \u003ca href=\"\/collections\/dc-breaker\"\u003eDC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-spd\"\u003eDC SPD\u003c\/a\u003e, and \u003ca href=\"\/collections\/solar-bundles\"\u003esolar bundles\u003c\/a\u003e. Free delivery over Rs.10,000. WhatsApp \u003cstrong\u003e0326-1111376\u003c\/strong\u003e.\u003c\/p\u003e","brand":"CNC ELECTRIC","offers":[{"title":"20A","offer_id":42324172079170,"sku":"YCB8-63PV","price":1600.0,"currency_code":"PKR","in_stock":true},{"title":"32A","offer_id":42324172111938,"sku":"YCB8-63PV","price":1600.0,"currency_code":"PKR","in_stock":false},{"title":"40A","offer_id":42324172144706,"sku":"YCB8-63PV","price":1600.0,"currency_code":"PKR","in_stock":false},{"title":"63A","offer_id":42324172177474,"sku":"2p-dc-mcb-4","price":1600.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/DC_2_Pole_63A_MCB_Circuit_Breakers_500V.webp?v=1755856397"},{"product_id":"cnc-3p-mcb-ac-circuits-breaker-ycb7h-63","title":"3 Pole MCB 20A-63A | AC Circuit Breaker","description":"\u003cdiv style=\"font-family:Segoe UI,Roboto,Arial,sans-serif;font-size:15px;line-height:1.7;color:#1a1a1a;\"\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eCNC 3 Pole MCB — Three-Phase Miniature Circuit Breaker\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThe CNC YCB7-63N 3 pole MCB is a three-phase miniature circuit breaker that protects three-phase circuits against overload and short circuit. It handles all three phase conductors (L1, L2, L3) simultaneously in a single trip mechanism, so a fault on any one phase disconnects all three — preventing the single-phasing condition that destroys three-phase motors and compressors.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eUnlike the \u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e4 Pole MCB\u003c\/a\u003e, the 3P version does NOT switch the neutral — use it where neutral is handled separately by a busbar or where the load has no neutral (three-phase motors, delta-connected loads). For three-phase supplies that require neutral switching (3-phase main incomers, star-connected loads), choose the 4 Pole version instead.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eRated at 400V AC with C-curve trip response, this MCB is standard equipment in Pakistani commercial, industrial, and agricultural panels — from workshop machinery protection to submersible pump feeders. CNC Electric is a trusted MCB brand in Pakistan with a \u003cstrong\u003e5-year replacement warranty\u003c\/strong\u003e on all circuit breakers.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e3 Pole MCB — Three-phase Miniature Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eYCB7-63N (3P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e3P (L1 + L2 + L3, no neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eCurrent Ratings\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16A, 20A, 32A, 40A, 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e400V AC, 50Hz (3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e6kA at 400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eTrip Curve\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eC-curve (trips at 5-10× rated current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eIEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e35mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eModule Width\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e3 modules (54mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eUp to 25mm² cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMechanical Life\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eElectrical Life\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e5-year replacement warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eSizing a 3 Pole MCB for Motor Protection\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eFor three-phase motor protection, pick a C-curve MCB rated at approximately \u003cstrong\u003e1.25× the motor full-load current\u003c\/strong\u003e. The table below shows typical sizing for Pakistani industrial motors at 400V 3-phase:\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eMotor Rating\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eApprox Full-Load Current\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eRecommended 3P MCB\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eCable Size\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e3 HP (2.2 kW)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~5.5A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e5 HP (3.7 kW)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~9A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e7.5 HP (5.5 kW)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~14A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e4mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10 HP (7.5 kW)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~18-19A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e6mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e15 HP (11 kW)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~27A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e40A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20 HP (15 kW)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~37A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e63A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e25 HP (18.5 kW)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~45A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e63A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eAbove 25 HP\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eOver 45A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB 100A+\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e25mm² or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eFor heavy-inrush motors\u003c\/strong\u003e (star-delta starters, DOL starters on large pumps), consider a D-curve MCB variant, or combine this C-curve MCB with a dedicated motor-protection circuit breaker (MPCB) that senses motor-specific overload conditions. For loads above 63A, move to an \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB breaker\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003e3 Pole vs 4 Pole — Which One Do You Need?\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eScenario\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eUse\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eThree-phase motor (delta connected, no neutral)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003e3 Pole (this product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eThree-phase submersible pump, compressor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003e3 Pole (this product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eThree-phase sub-distribution with separate neutral busbar\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003e3 Pole (this product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eThree-phase main incomer (WAPDA 3-phase supply)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e4 Pole MCB\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eThree-phase solar inverter AC output (needs neutral switch)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e4 Pole MCB\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eStar-connected 3-phase load with neutral\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e4 Pole MCB\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eTypical Applications in Pakistan\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eAgricultural tube-wells and submersible pumps:\u003c\/strong\u003e 5-15 HP three-phase motors driven from WAPDA or \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003egenerator-switched\u003c\/a\u003e supplies. The 32A or 40A 3P MCB sits at the starter panel and protects the motor cable against overload and short circuit.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eWorkshop and light industrial machinery:\u003c\/strong\u003e lathes, milling machines, welding rectifiers, small compressors (delta-connected). Each machine gets its own 3P MCB feeder in the shop DB.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eThree-phase air conditioning:\u003c\/strong\u003e larger commercial ACs (3 ton and above) are often fed from a 3P MCB when they use delta-connected compressors without neutral.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eCommercial sub-distribution:\u003c\/strong\u003e when a three-phase sub-DB is fed by a common neutral busbar and only the three phases need to be switched at the feeder level.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eFlour mills, cotton gins, food-processing plants:\u003c\/strong\u003e standard 3P MCB per motor bay, protecting the long cable run back to the main panel.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eWhy C-Curve for 3-Phase Motors\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThree-phase motors draw a starting inrush of 5-7× full-load current for about 1-2 seconds during start-up (DOL start). A C-curve MCB (trips at 5-10× rated current after a short delay) tolerates this inrush without nuisance tripping while still protecting against sustained overload and short circuit.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eFor very heavy inrush — star-delta starters on 15 HP+ motors, or transformers — choose a D-curve variant (trips at 10-20× rated). For resistive-only loads (heaters), B-curve is adequate. For motor control in Pakistan, \u003cstrong\u003eC-curve is the practical default\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eRelated Products\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0 16px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eThree-phase main incomer with neutral → \u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e4 Pole MCB 20A-63A (Rs.1,900)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-phase branch circuits → \u003ca href=\"\/products\/cnc-1-pole-mcb-ac-breaker-ycb7-63a\" style=\"color:#d42027;\"\u003e1 Pole MCB 2A-63A (Rs.425)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-phase main incomer → \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027;\"\u003e2 Pole MCB 10A-63A (Rs.850)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAbove 63A or industrial fault levels → \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB breakers 100A-1250A\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eThree-phase generator switching → \u003ca href=\"\/collections\/ats\" style=\"color:#d42027;\"\u003eATS 3-phase\u003c\/a\u003e or \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003e3P\/4P changeover switch\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eMotor contactor for start\/stop → \u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;\"\u003eMagnetic contactors\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eMotor soft-start control → \u003ca href=\"\/collections\/variable-frequency-drive\" style=\"color:#d42027;\"\u003eVariable Frequency Drive (VFD)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eThree-phase voltage monitoring → \u003ca href=\"\/collections\/phase-sequence-relay\" style=\"color:#d42027;\"\u003ePhase Sequence Relay\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eComplete DB setup → \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB boxes\u003c\/a\u003e + breakers\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRead our guide → \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of Circuit Breakers in Pakistan\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is a 3 Pole MCB?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eA 3 Pole MCB is a miniature circuit breaker that protects three-phase circuits by disconnecting all three phase conductors (L1, L2, L3) together on overload or short circuit. The three poles are mechanically linked — a fault on any one phase trips all three. This prevents the dangerous single-phasing condition that destroys three-phase motors. The 3 Pole MCB does NOT switch the neutral wire; for circuits that need neutral switching, use a \u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e4 Pole MCB\u003c\/a\u003e instead.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is the difference between 3 Pole and 4 Pole MCB?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eA 3 Pole MCB switches only the three phase conductors (L1, L2, L3). A 4 Pole MCB switches all three phases plus the neutral. Use 3P where neutral is handled separately by a busbar, or where the load has no neutral (delta-connected motors). Use 4P for three-phase main incomers and for star-connected loads that need full isolation.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat size 3 Pole MCB for a 10 HP three-phase motor?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eA 10 HP three-phase motor at 400V draws approximately 18-19A full-load current. Using the standard 1.25× sizing rule, a \u003cstrong\u003e32A C-curve 3 Pole MCB\u003c\/strong\u003e on 6mm² cable is the correct choice. The C-curve handles the DOL starting inrush of roughly 5-7× full-load current without nuisance tripping. Add a magnetic contactor for on\/off control and thermal overload relay or MPCB for motor-specific overload protection.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is the 3 Pole 63A MCB price in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eThe CNC YCB7-63N 3 Pole 63A MCB is available at Rs.1,350 at CNC Electric Pakistan. Competitor brands: Schneider iC60N 3P 63A typically costs Rs.5,500-7,000, and Chint NB1 3P 63A costs Rs.2,000-2,500. CNC offers equivalent IEC 60898 certified performance with 6kA breaking capacity at a significantly lower price with a 5-year replacement warranty included.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eCan I use a 3 Pole MCB as main incomer on 3-phase WAPDA supply?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eOnly if the installation uses a common neutral busbar and the neutral is not routed through the main breaker. For a full-isolation 3-phase main incomer where both the three phases AND the neutral should disconnect together, use a \u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e4 Pole MCB\u003c\/a\u003e. In most modern installations a 4 Pole is the safer choice at the main incomer because it allows complete de-energisation of the DB during maintenance.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eDoes a 3 Pole MCB provide motor overload protection?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003ePartially. The 3 Pole MCB protects the motor cable and panel against short circuit, and it trips on sustained overload. However it does NOT detect motor-specific issues like stalled rotor, unbalanced phases, or thermal overload on only one phase. For complete motor protection, combine this 3P MCB with either (a) a thermal overload relay set to the motor FLC, or (b) a dedicated motor-protection circuit breaker (MPCB), or (c) a \u003ca href=\"\/collections\/variable-frequency-drive\" style=\"color:#d42027;\"\u003eVFD\u003c\/a\u003e that includes built-in motor protection.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat breaking capacity does the CNC 3 Pole MCB have?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003e6kA at 400V AC, per IEC 60898-1. This is adequate for residential, commercial, and small industrial panels where the prospective short-circuit current is under 6 kiloamperes (kA). For installations close to a large transformer where fault levels can exceed 6 kA, move up to an \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB\u003c\/a\u003e with 15-50 kA breaking capacity.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eHow wide is the 3 Pole MCB on the DIN rail?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eThe CNC YCB7-63N 3 Pole MCB is 54mm wide — three DIN-rail modules. Plan your DB box capacity accordingly. A 12-way DB box with three 3P MCBs already uses 9 of the 12 modules, leaving 3 modules for branch or auxiliary circuits.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"16A","offer_id":43049378807874,"sku":null,"price":1350.0,"currency_code":"PKR","in_stock":false},{"title":"20A","offer_id":42444618694722,"sku":"YCB7-63N","price":1350.0,"currency_code":"PKR","in_stock":true},{"title":"32A","offer_id":42324172865602,"sku":"YCB7-63N","price":1350.0,"currency_code":"PKR","in_stock":true},{"title":"40A","offer_id":42444618727490,"sku":"YCB7-63N","price":1350.0,"currency_code":"PKR","in_stock":false},{"title":"63A","offer_id":42324172898370,"sku":"YCB7-63N","price":1350.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/3P_MCB_AC_Circuit_Breaker.webp?v=1755855529"},{"product_id":"cnc-1p-n-ac-mcb-circuit-breaker-ycb9n-40","title":"1P+N MCB 10A-40A | Compact Circuit Breaker","description":"\u003cdiv style=\"font-family:Segoe UI,Roboto,Arial,sans-serif;font-size:15px;line-height:1.7;color:#1a1a1a;\"\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eCNC 1P+N MCB — Single Module Live and Neutral Breaker\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThe CNC YCB9N-40 is a 1P+N miniature circuit breaker that disconnects both live and neutral in a single 18mm DIN-rail module. It provides the same overload and short-circuit protection as a standard single-pole MCB while also switching the neutral — an important safety feature for Pakistani wiring where phase and neutral are frequently reversed at the meter or junction box.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eBecause it takes only \u003cstrong\u003eone DIN-rail module\u003c\/strong\u003e instead of two (as a true 2 pole MCB would), you can fit twice as many protected circuits into the same DB box. This makes 1P+N MCBs the go-to choice for apartment panels, compact residential DB boxes, and retail shops where DIN-rail space is tight.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eAvailable from 10A to 40A with C-curve trip response, the YCB9N-40 handles general lighting, socket, AC, and inverter output circuits across Pakistani homes. CNC Electric is a trusted MCB brand in Pakistan with a \u003cstrong\u003e5-year replacement warranty\u003c\/strong\u003e on all circuit breakers.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1P+N MCB — Miniature Circuit Breaker (Single Module L+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eYCB9N-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1P+N (1 protected pole + 1 switched neutral, single 18mm module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eCurrent Ratings\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10A, 20A, 32A, 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e230V AC, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e6kA at 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eTrip Curve\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eC-curve (trips at 5-10× rated current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eIEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e35mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eModule Width\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1 module (18mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eUp to 16mm² cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMechanical Life\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eElectrical Life\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e5-year replacement warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003e1P+N vs True 2 Pole — What's the Difference?\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eBoth 1P+N and \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027;\"\u003etrue 2 Pole MCBs\u003c\/a\u003e disconnect live and neutral together, but they are not electrically identical:\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003e1P+N (this product)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eTrue 2 Pole MCB\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eOverload protection on\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eLive pole only\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eBoth poles independently\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eNeutral behaviour\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eSwitched (follows live on trip)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eSwitched + protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1 module (18mm)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2 modules (36mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eBest for\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eBranch circuits needing neutral break in compact DB\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMain incoming breaker, generator\/inverter circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003ePrice (63A equivalent)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRs.825 (40A max)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRs.850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eRule of thumb:\u003c\/strong\u003e use 1P+N for individual branch circuits in space-constrained DB boxes; use a true 2 Pole MCB for the main incomer where both poles should have independent overload protection.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eAmperage Selection Guide\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eCable Size\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eCommon Use in Pakistan\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eLighting circuit, bedroom\/living-room sockets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eHeavy socket circuit, 1-1.5 ton inverter AC, microwave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e6mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2 ton inverter AC, electric geyser, kitchen appliance circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e40A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eSub-main feeder, UPS output, solar inverter sub-DB output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eWhere to Use 1P+N MCBs\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eApartment and compact DB boards:\u003c\/strong\u003e a 12-way DB box that would only fit 6 circuits with true 2 Pole MCBs can fit 12 circuits with 1P+N MCBs — because each takes one module instead of two.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eBathroom and kitchen circuits:\u003c\/strong\u003e safety-critical circuits where the neutral needs to disconnect on trip. Pair with an \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO earth leakage breaker\u003c\/a\u003e for complete shock protection in wet areas.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eSolar inverter sub-DB output circuits:\u003c\/strong\u003e the AC output from a solar inverter can be distributed through a sub-DB using 1P+N MCBs. See also \u003ca href=\"\/collections\/solar-bundles\" style=\"color:#d42027;\"\u003esolar DB bundles\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eRetail, office, and POS circuits:\u003c\/strong\u003e individual cash-counter, computer, and display-lighting circuits that need full neutral isolation for safe maintenance.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eExtension board and UPS output protection:\u003c\/strong\u003e where a true 2P MCB would take too much space in the parent enclosure.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eWhy C-Curve Matters in Pakistan\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003ePakistani circuits typically run a mix of lights, fans, ACs, refrigerators, and inverters. Inverter ACs and fridge compressors draw high inrush current on start-up (up to 10× rated current for a fraction of a second). A C-curve MCB tolerates this inrush without nuisance tripping — trips only on sustained overload (5-10× rated) or short-circuit fault.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eB-curve (trips at 3-5×) is too sensitive for motor loads and would trip every time the AC compressor starts. D-curve (trips at 10-20×) is for heavy industrial inrush (welders, transformers) and misses general overloads. \u003cstrong\u003eC-curve is the correct choice for every residential and light commercial branch circuit in Pakistan.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eRelated Products\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0 16px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eBranch circuits live-only → \u003ca href=\"\/products\/cnc-1-pole-mcb-ac-breaker-ycb7-63a\" style=\"color:#d42027;\"\u003e1 Pole MCB 2A-63A (Rs.425)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eMain incomer with both poles protected → \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027;\"\u003e2 Pole MCB 10A-63A (Rs.850)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eThree-phase circuits → \u003ca href=\"\/products\/cnc-3p-mcb-ac-circuits-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e3 Pole MCB\u003c\/a\u003e or \u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e4 Pole MCB\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eEarth leakage \/ shock protection → \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO breakers\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eVoltage protection → \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;\"\u003eVA Protector\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSurge \/ lightning protection → \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD surge protectors\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eComplete DB setup → \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB boxes\u003c\/a\u003e + MCBs\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSolar DC side → \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027;\"\u003eDC circuit breakers\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRead our guide → \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of Circuit Breakers in Pakistan\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is a 1P+N MCB?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003e1P+N MCB is a miniature circuit breaker that combines one protected pole (live) and one switched pole (neutral) in a single DIN-rail module just 18mm wide. When the breaker trips on overload or short circuit, both the live and neutral conductors disconnect together — but only the live pole has independent overload detection. Because the whole device occupies a single module, it lets you fit twice as many protected circuits into the same DB box compared with a true 2 Pole MCB.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is the difference between 1P+N and 2 Pole MCB?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eA 1P+N MCB has one protected pole with overload detection and one switched pole that follows the live — it occupies 1 DIN-rail module. A true 2 Pole MCB has two independently protected poles, each with its own overload detection — it occupies 2 modules. For branch circuits needing a neutral break, 1P+N saves space. For main incomers where both poles should be independently protected, a true 2 Pole MCB is recommended.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhy choose 1P+N instead of a plain 1 Pole MCB?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eIn Pakistani wiring, phase and neutral are sometimes reversed at the meter or junction box. A plain 1 Pole MCB only disconnects the terminal it is wired to — if that terminal is carrying the neutral by mistake, the circuit stays live even after tripping. A 1P+N MCB eliminates that risk by always disconnecting both conductors, making it safer for residential branch circuits and circuits accessed by non-technical users.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is the 1P+N 40A MCB price in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eThe CNC YCB9N-40 1P+N MCB 40A is available at Rs.825 at CNC Electric Pakistan. Competitor brands: Schneider iC60N 1P+N 40A typically costs Rs.2,200-2,800, and Chint NB1 1P+N 40A costs Rs.1,100-1,300. CNC offers equivalent IEC 60898 certified performance at a significantly lower price with a 5-year replacement warranty included.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eCan I use 1P+N MCB as a main incoming breaker?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eNot recommended. For the main incoming breaker, use a true 2 Pole MCB (up to 63A) or an MCCB (above 63A). The main incomer should have independent overload protection on both conductors — a 1P+N only protects the live pole. Use 1P+N for downstream branch circuits, not as the first breaker after the WAPDA meter.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eDoes the 1P+N MCB protect against electric shock?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eNo. The 1P+N MCB, like any standard MCB, protects only against overload and short circuit. It will not trip on earth-leakage currents of 30mA that cause electric shock. For bathroom, kitchen, and outdoor circuits, pair the 1P+N MCB with an \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO earth leakage breaker\u003c\/a\u003e for complete shock protection.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eCan I use 1P+N MCB on a solar inverter circuit?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eYes on the AC output side of a solar inverter, for individual sub-DB distribution circuits. For the main AC output from the inverter to the DB, use a true 2 Pole MCB. For the DC side (panels to inverter), never use an AC MCB — use purpose-built \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027;\"\u003eDC circuit breakers\u003c\/a\u003e rated for 500V, 1000V, or 1500V depending on your string configuration.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eHow wide is the 1P+N MCB on the DIN rail?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eThe CNC YCB9N-40 1P+N MCB is 18mm wide — one single DIN-rail module. A 12-way DB box fits up to 12 of these breakers, compared with only 6 true 2 Pole MCBs (which are 36mm each). This module-saving advantage is the main reason 1P+N breakers are preferred in apartment and compact residential DB panels.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"cnc-related-blog\" style=\"margin-top:1.5em;padding:1em;background:#f8f9fa;border-left:4px solid #fa3433;border-radius:6px;\"\u003e\u003cstrong\u003e📖 Related Reading:\u003c\/strong\u003e \u003ca href=\"\/blogs\/news\/wifi-smart-breaker-vs-normal-breaker-pakistan-comparison\" title=\"WiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\" style=\"color:#fa3433;font-weight:600;\"\u003eWiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\u003c\/a\u003e — In-depth guide on this product category. \u003cbr\u003e\u003cem\u003eHelpful for understanding sizing, installation, and choosing the right model for your Pakistan setup.\u003c\/em\u003e\u003c\/p\u003e","brand":"CNC ELECTRIC","offers":[{"title":"10A","offer_id":42324172931138,"sku":"YCB9N-40","price":850.0,"currency_code":"PKR","in_stock":false},{"title":"20A","offer_id":42324172963906,"sku":"YCB9N-40","price":850.0,"currency_code":"PKR","in_stock":false},{"title":"32A","offer_id":42324172996674,"sku":"YCB9N-40","price":850.0,"currency_code":"PKR","in_stock":false},{"title":"40A","offer_id":42324173029442,"sku":"YCB9N-40","price":850.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/1P_N_MCB_AC_Circuit_Breaker.webp?v=1755853562"},{"product_id":"cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63","title":"2 Pole MCB 10A-63A | AC Circuit Breaker","description":"\u003cdiv style=\"font-family:Segoe UI,Roboto,Arial,sans-serif;font-size:15px;line-height:1.7;color:#1a1a1a;\"\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eCNC 2 Pole MCB — Double Pole Miniature Circuit Breaker (Safety Breaker)\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThe CNC YCB7H 2 pole MCB (miniature circuit breaker) is a double pole breaker that disconnects \u003cstrong\u003eboth live and neutral\u003c\/strong\u003e simultaneously — providing complete isolation of the circuit. MCB full form is \u003cstrong\u003eMiniature Circuit Breaker\u003c\/strong\u003e, and this 2P version is the standard main incoming breaker for single-phase distribution boards across Pakistan.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eUnlike a \u003ca href=\"\/products\/cnc-1-pole-mcb-ac-breaker-ycb7-63a\" style=\"color:#d42027;\"\u003e1 pole MCB\u003c\/a\u003e which only disconnects the live wire, this double pole MCB breaker cuts both live and neutral — essential for circuits fed by generators, inverters, or \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003echangeover switches\u003c\/a\u003e where the neutral may carry dangerous voltage during a fault. Every single-phase home DB box in Pakistan needs a 2 pole MCB as its main breaker switch.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eAvailable from 10A to 63A with C-curve trip response, this safety breaker handles everything from a small sub-main to the main incoming supply for a full Pakistani household. CNC Electric is a trusted MCB breaker brand in Pakistan with a 5-year replacement warranty on all circuit breakers.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMCB — Miniature Circuit Breaker (Double Pole Safety Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2P (Double Pole — disconnects live + neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eCurrent Ratings\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10A, 16A, 20A, 25A, 32A, 40A, 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e230V\/400V AC, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e6kA at 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eTrip Curve\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eC-curve (trips at 5-10× rated current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eIEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e35mm DIN rail (standard for all Pakistani DB boxes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eModule Width\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2 modules (36mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eUp to 25mm² cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e-5°C to +40°C (derates above 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMechanical Life\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eElectrical Life\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e5-year replacement warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eDelivery\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eFree delivery across Pakistan on orders over Rs.10,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eWhy You Need a 2 Pole (Double Pole) Breaker\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eIn Pakistan's electrical system, a single pole breaker only disconnects the live wire — the neutral remains connected. This is fine for individual branch circuits. But for your \u003cstrong\u003emain incoming breaker\u003c\/strong\u003e, you need both wires disconnected for these critical reasons:\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eNeutral failure protection:\u003c\/strong\u003e In Pakistani wiring, neutral failures are extremely common — especially in areas with shared neutral or underground cable problems. When the neutral breaks, some appliances can receive up to 440V instead of 220V, destroying AC compressor boards (Rs.15,000-35,000 repair), refrigerator circuits, and electronics. A 2 pole MCB as the main breaker allows you to disconnect the entire circuit — both live and neutral — during maintenance or emergencies.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eGenerator and inverter circuits:\u003c\/strong\u003e When switching between WAPDA and generator via a \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003echangeover switch\u003c\/a\u003e or \u003ca href=\"\/collections\/ats\" style=\"color:#d42027;\"\u003eautomatic transfer switch (ATS)\u003c\/a\u003e, the neutral from the generator is different from the WAPDA neutral. A 2 pole breaker ensures complete isolation of both wires when switching sources.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eSolar inverter AC output:\u003c\/strong\u003e The AC output from your solar inverter needs a 2 pole MCB before entering the DB box. This ensures the inverter is fully isolated during maintenance — critical for safety because the inverter generates its own live and neutral.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eWhich Rating for Which Application\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eCable Size\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eCommon Use as 2 Pole Breaker in Pakistan\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eSub-circuit for lighting only, small UPS output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eDedicated appliance circuit (washing machine, geyser on its own line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1-1.5 ton inverter AC on dedicated circuit with full isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e25A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e4mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eSmall inverter\/UPS output, 1.5 ton AC dedicated circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e6mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eSub-main feeder to secondary DB, small shop main, EV charger circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e40A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMain incoming breaker for small home (2-3 ACs), solar inverter output up to 8kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e63A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\n\u003cstrong\u003eStandard main incoming breaker\u003c\/strong\u003e for typical Pakistani single-phase home, large shop, solar inverter up to 15kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eMost common choice:\u003c\/strong\u003e 63A as the main incoming breaker for a Pakistani home. This sits at the top of your DB box, before all branch \u003ca href=\"\/products\/cnc-1-pole-mcb-ac-breaker-ycb7-63a\" style=\"color:#d42027;\"\u003e1 pole MCBs\u003c\/a\u003e. If your total load exceeds 63A, you need an \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB breaker\u003c\/a\u003e instead.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003e1 Pole vs 2 Pole vs 4 Pole — When to Use Which\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eDisconnects\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eUse When\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1 Pole MCB\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eLive only\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eBranch circuits: individual lights, sockets, single appliance\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRs.425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003e2 Pole MCB (this product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003eLive + Neutral\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003eMain breaker, generator\/inverter circuits, full isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003eRs.850\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e3 Pole MCB\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e3 phases (L1+L2+L3)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eThree-phase motor circuits, industrial without neutral\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRs.1,300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e4 Pole MCB\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e3 phases + Neutral\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eThree-phase main breaker, solar inverter 3-phase output\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRs.1,850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eTypical Pakistani Home DB Box Layout\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eA properly wired single-phase home in Lahore, Karachi, Islamabad, or any city in Pakistan should have this DB box structure:\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003ePosition 1 (top):\u003c\/strong\u003e 2 Pole MCB 63A (this product) — main incoming breaker. All power flows through this first. Install a \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;\"\u003eVA voltage protector\u003c\/a\u003e immediately after this breaker for voltage protection.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003ePosition 2-12 (branches):\u003c\/strong\u003e \u003ca href=\"\/products\/cnc-1-pole-mcb-ac-breaker-ycb7-63a\" style=\"color:#d42027;\"\u003e1 Pole MCBs\u003c\/a\u003e (Rs.425 each) — one per circuit. Typical home: 10A for lighting, 16A for sockets, 20A for each AC, 16A for geyser, 10A for refrigerator.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eAdd for safety:\u003c\/strong\u003e \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO earth leakage breaker\u003c\/a\u003e for bathroom\/kitchen circuits, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD surge protector\u003c\/a\u003e at the main panel for lightning protection. Browse our \u003ca href=\"\/collections\/solar-bundles\" style=\"color:#d42027;\"\u003esolar DB bundles\u003c\/a\u003e for pre-configured kits that include all these components.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eWhy C-Curve Is the Standard in Pakistan\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eMCB trip curves define how much inrush current the breaker tolerates before tripping:\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eTrip Curve\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eTrips At\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eB-curve\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e3-5× rated current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003ePurely resistive loads only — rarely used in Pakistan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003eC-curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003e5-10× rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003eStandard for all general circuits — handles AC\/motor startup inrush\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eD-curve\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10-20× rated current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eHeavy inrush — industrial\/factory circuits only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eWhat This Breaker Does NOT Protect Against\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eA 2 pole MCB protects against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuit\u003c\/strong\u003e only. It does NOT protect against:\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eVoltage fluctuation\u003c\/strong\u003e — If WAPDA voltage spikes to 280V or drops to 140V, the MCB will not react. Install a \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;\"\u003eVA voltage protector (Rs.1,700-2,000)\u003c\/a\u003e immediately after this 2 pole main breaker. The VA device monitors voltage 24\/7 and disconnects if it goes outside safe range — protecting your AC, fridge, and electronics from burning.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eElectric shock \/ earth leakage\u003c\/strong\u003e — If someone touches a live wire, 30mA flowing through the body will not trip this MCB. You need an \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO earth leakage breaker\u003c\/a\u003e on bathroom, kitchen, and outdoor circuits.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eLightning and surge\u003c\/strong\u003e — Thousands of volts from a nearby lightning strike will pass right through the MCB. Install an \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD surge protection device\u003c\/a\u003e at the main panel.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eRelated Products\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0 16px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eBranch circuit breakers → \u003ca href=\"\/products\/cnc-1-pole-mcb-ac-breaker-ycb7-63a\" style=\"color:#d42027;\"\u003e1 Pole MCB 2A-63A (Rs.425)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eCompact 1P+N in one module → \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027;\"\u003e1P+N MCB 10A-40A (Rs.825)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eThree-phase circuits → \u003ca href=\"\/products\/cnc-3p-mcb-ac-circuits-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e3 Pole MCB (Rs.1,300)\u003c\/a\u003e or \u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e4 Pole MCB (Rs.1,850)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eLoad above 63A → \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB breakers 100A-1250A\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eVoltage protection → \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;\"\u003eVA Protector (Rs.1,700-5,200)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAutomatic WAPDA-generator switching → \u003ca href=\"\/collections\/ats\" style=\"color:#d42027;\"\u003eATS Automatic Transfer Switches\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eManual generator switching → \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003eChangeover Switches\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSolar DC side → \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027;\"\u003eDC circuit breakers\u003c\/a\u003e (never use AC breaker on DC)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eComplete DB setup → \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB boxes\u003c\/a\u003e + breakers\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRead our guide → \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of Circuit Breakers in Pakistan — Complete Guide\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is a 2 pole MCB? What is double pole breaker?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eA 2 pole MCB (double pole breaker) is a miniature circuit breaker that disconnects both the live wire and the neutral wire at the same time. MCB full form is Miniature Circuit Breaker. The \"2 pole\" means it has two switching mechanisms linked together — when it trips or is switched off, both poles open simultaneously. In Pakistan, electricians call it a \"double pole breaker\" or \"DP breaker\" or simply \"2P MCB\". It's the standard main incoming breaker switch for single-phase home and shop DB boxes.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhy use 2 pole MCB instead of 1 pole as main breaker?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eA 1 pole MCB only disconnects the live wire — the neutral stays connected. In Pakistan, neutral failures are common and can send dangerous voltage through the neutral wire. With a 2 pole MCB as your main breaker, when you switch it off for maintenance or it trips during a fault, both wires are completely disconnected — zero voltage in your DB box. This is essential for safe maintenance and for circuits connected to generators or solar inverters where the neutral path differs from WAPDA supply.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat size 2 pole MCB for Pakistani home main breaker?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eFor most single-phase homes in Pakistan, a \u003cstrong\u003e63A 2 pole MCB\u003c\/strong\u003e is the standard main incoming breaker. This handles a typical household with 2-3 ACs, geyser, refrigerator, washing machine, and general lighting\/sockets. If your home has more than 3 ACs or heavy commercial loads, you may need an \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB breaker\u003c\/a\u003e rated at 100A or higher.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is the 2 pole 63A MCB price in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eThe CNC 2 Pole 63A MCB is available at Rs.850 at CNC Electric Pakistan. Competitor brands: Schneider Domae 2P 63A typically costs Rs.1,800-2,200, and Chint 2P 63A costs Rs.1,000-1,200. CNC offers the same IEC 60898-1 certified performance with 6kA breaking capacity at approximately 50-60% lower price, with a 5-year replacement warranty included.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eCan I use a 2 pole MCB for a generator changeover circuit?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eYes — a 2 pole MCB is essential on both the WAPDA side and the generator side of a manual \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003echangeover switch\u003c\/a\u003e. Each source needs its own 2P MCB for isolation. When switching between sources, you turn off one 2P breaker before turning on the other. For automatic switching, use an \u003ca href=\"\/collections\/ats\" style=\"color:#d42027;\"\u003eATS (Automatic Transfer Switch)\u003c\/a\u003e which handles this in under 50 milliseconds.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eDo I need a 2 pole MCB for my solar inverter?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eYes. The AC output from your solar inverter must pass through a 2 pole MCB before entering your DB box. This ensures complete isolation of the inverter during maintenance — critical for safety because the inverter generates its own live and neutral even when WAPDA is off. For the DC side (panels to inverter), you need separate \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027;\"\u003eDC circuit breakers\u003c\/a\u003e rated for your system voltage (500V, 1000V, or 1500V). Pair with an \u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027\"\u003eaerosol fire extinguisher\u003c\/a\u003e for added panel safety. For over and under voltage protection, add a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protector\u003c\/a\u003e to your board.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is the difference between 2 pole MCB and 1P+N MCB?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eBoth disconnect live and neutral, but they work differently. A 2 pole MCB has two independent trip mechanisms — both poles are protected and can trip independently on overload. A 1P+N MCB has one protected pole (live) and one switched-only pole (neutral) — the neutral follows the live but doesn't have its own overload detection. For main incoming breakers, a true 2 pole MCB (Rs.850) is recommended over 1P+N (Rs.825) because both poles are independently protected.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eCNC 2 pole MCB vs Schneider — which is better?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eBoth CNC and Schneider manufacture 2 pole MCBs to the same IEC 60898-1 standard with 6kA breaking capacity. Schneider (Domae series) is a European brand with pricing at Rs.1,800-2,200 for a 2P 63A. CNC offers identical certified performance at Rs.850 — more than 50% savings — with a 5-year replacement warranty. For residential and commercial use in Pakistan, either brand provides reliable protection. The choice depends on budget and brand preference.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:8px\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/ac-breaker-size-guide-pakistan-air-conditioner-hybrid-solar-inverter\" style=\"color:#d42027\"\u003eAC Breaker Size Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"cnc-related-blog\" style=\"margin-top:1.5em;padding:1em;background:#f8f9fa;border-left:4px solid #fa3433;border-radius:6px;\"\u003e\u003cstrong\u003e📖 Related Reading:\u003c\/strong\u003e \u003ca href=\"\/blogs\/news\/wifi-smart-breaker-vs-normal-breaker-pakistan-comparison\" title=\"WiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\" style=\"color:#fa3433;font-weight:600;\"\u003eWiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\u003c\/a\u003e — In-depth guide on this product category. \u003cbr\u003e\u003cem\u003eHelpful for understanding sizing, installation, and choosing the right model for your Pakistan setup.\u003c\/em\u003e\u003c\/p\u003e","brand":"CNC ELECTRIC","offers":[{"title":"10A","offer_id":42444609880130,"sku":"YCB7-63N","price":900.0,"currency_code":"PKR","in_stock":true},{"title":"16A","offer_id":42444609912898,"sku":"YCB7-63N","price":900.0,"currency_code":"PKR","in_stock":true},{"title":"20A","offer_id":42324173062210,"sku":"YCB7-63N","price":900.0,"currency_code":"PKR","in_stock":true},{"title":"25A","offer_id":42444609945666,"sku":"YCB7-63N","price":900.0,"currency_code":"PKR","in_stock":true},{"title":"32A","offer_id":42324173094978,"sku":"YCB7-63N","price":900.0,"currency_code":"PKR","in_stock":false},{"title":"40A","offer_id":42324173127746,"sku":"YCB7-63N","price":900.0,"currency_code":"PKR","in_stock":false},{"title":"63A","offer_id":42324173160514,"sku":"YCB7-63N","price":900.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/2P_MCB_AC_Cricuit_Breaker.webp?v=1755855349"},{"product_id":"cnc-1-pole-mcb-ac-breaker-ycb7-63a","title":"1 Pole MCB 2A-63A | Circuit Breaker Pakistan","description":"\u003cdiv style=\"font-family:Segoe UI,Roboto,Arial,sans-serif;font-size:15px;line-height:1.7;color:#1a1a1a;\"\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eCNC 1 Pole MCB — Single Pole Miniature Circuit Breaker (Safety Breaker)\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThe CNC YCB7 single pole MCB (miniature circuit breaker) is the standard safety breaker used in residential, commercial, and light industrial distribution boards across Pakistan. MCB full form is \u003cstrong\u003eMiniature Circuit Breaker\u003c\/strong\u003e — a compact electric breaker that automatically disconnects the circuit during overload or short-circuit faults, protecting your wiring and appliances from damage and fire.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eAvailable in current ratings from 2A to 63A, this breaker switch fits every branch circuit in a Pakistani home, shop, or office DB box. Whether you need a 10A breaker for lighting, a 20A breaker for sockets, or a 32A breaker for your inverter AC — this single pole circuit breaker handles it with C-curve trip response designed for the mixed loads common in Pakistani installations.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eCNC Electric is a trusted MCB breaker brand in Pakistan with a 5-year replacement warranty on all circuit breakers.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMCB — Miniature Circuit Breaker (Safety Breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1P (Single Pole — disconnects live wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eCurrent Ratings\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e230V AC, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e6kA at 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eTrip Curve\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eC-curve (trips at 5-10× rated current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eIEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e35mm DIN rail (standard for all Pakistani DB boxes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eModule Width\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1 module (18mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eUp to 25mm² cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e-5°C to +40°C (derates above 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMechanical Life\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eElectrical Life\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e5-year replacement warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eDelivery\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eFree delivery across Pakistan on orders over Rs.10,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eBreaker Size Chart — Which Rating Do You Need?\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThe breaker rating must protect the \u003cstrong\u003ecable\u003c\/strong\u003e, not the appliance. This is the most common mistake in Pakistani homes — installing a 32A breaker on thin 1.5mm² cable creates a fire risk because the cable overheats before the breaker trips.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eBreaker Rating\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eCable Size\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eCommon Application in Pakistan\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e6A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1.0mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eSingle LED lighting circuit, exhaust fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eLighting ring circuit for 2-3 rooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eSocket circuit for small appliances, TV, computer, charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eHeavy socket circuit, washing machine, microwave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e25A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e4mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1 ton or 1.5 ton inverter AC, medium geyser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e6mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2 ton inverter AC, large geyser, electric oven, EV charger (3.5kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e40A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eSub-main feeder, multiple AC units on one circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e63A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMain incoming breaker for single-phase home, large sub-main\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eAppliance-Specific Breaker Selection (Pakistan)\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e In Pakistan, a 1.5 ton inverter AC draws approximately 7-8 amps running but 25-35 amps during compressor startup (inrush). A 20A C-curve MCB handles this — the C-curve tolerates inrush up to 10× rated current (200A momentary) without nuisance tripping.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eAppliance\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eRecommended Breaker\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eCable\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1 ton inverter AC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16A or 20A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~5-6A running, 15-25A inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1.5 ton inverter AC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20A or 25A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e4mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~7-8A running, 25-35A inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2 ton inverter AC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e25A or 32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e4-6mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~10-12A running, 35-50A inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eElectric geyser (small)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16A or 20A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~8-10A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eElectric geyser (large)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e25A or 32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e4-6mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~12-15A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eWashing machine\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~3-5A with motor inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRefrigerator \/ deep freezer\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10A or 16A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1.5-2.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~1-3A with compressor inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMicrowave oven\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e16A or 20A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~5-8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eSolar inverter (AC output)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e32A or 40A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e6-10mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eDepends on inverter kW rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eEV charger (3.5kW single phase)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e6mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e~15A continuous at 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eUPS \/ Inverter output\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e20A or 32A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e4-6mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eDepends on UPS capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eLighting circuit (full room)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e1.5mm²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMultiple lights, fans, sockets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eWhen to Use Single Pole vs 2 Pole vs 4 Pole\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eWhat It Disconnects\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eUse When\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003e1 Pole (this product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eLive wire only\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eBranch circuits: individual lights, sockets, appliance circuits in a single-phase DB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e2 Pole MCB (double pole)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eLive + Neutral\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMain incoming breaker, generator\/inverter circuits, appliances needing full isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e3 Pole MCB\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e3 phases (L1+L2+L3)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eThree-phase motor circuits, industrial equipment without neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e4 Pole MCB\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e3 phases + Neutral\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eMain incoming breaker in three-phase DB, solar inverter AC output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eFor a typical Pakistani single-phase home DB box: use a 63A \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027;\"\u003e2 Pole MCB\u003c\/a\u003e as the main breaker, and 1 Pole MCBs (this product) for all individual branch circuits.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eWhy C-Curve Is the Standard in Pakistan\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eMCB trip curves define how much inrush current the breaker tolerates before tripping:\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:16px 0 24px 0;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eTrip Curve\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eTrips At\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eBest For\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d0d0;padding:10px 12px;text-align:left;background:#f0f0f0;font-weight:700;color:#111;\"\u003eUse in Pakistan\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eB-curve\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e3-5× rated current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003ePurely resistive loads (heaters, lights only)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eRarely used — most circuits have motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003eC-curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003e5-10× rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003eMixed loads with moderate inrush (ACs, fridges, motors)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e\u003cstrong\u003eStandard for all general circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eD-curve\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003e10-20× rated current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eHeavy inrush (transformers, welding, large motors)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d0d0;padding:10px 12px;\"\u003eIndustrial\/factory circuits only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThis CNC MCB uses C-curve, which handles the startup inrush from inverter ACs, refrigerators, washing machines, and UPS systems without nuisance tripping — making it the right choice for virtually every residential and commercial circuit in Pakistan.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eApplications Across Pakistan\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eResidential homes:\u003c\/strong\u003e Every room's lighting and socket circuit runs through a 1 pole MCB in the DB box. Typical Lahore, Karachi, Islamabad, Faisalabad, or Multan home uses 6-12 single pole MCBs for individual circuits plus a 2 pole MCB as the main breaker.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eShops and offices:\u003c\/strong\u003e Socket circuits for computers, POS systems, and display lighting. Each circuit gets its own MCB so a fault in one circuit doesn't affect the rest of the shop.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eSolar installations:\u003c\/strong\u003e On the AC output side of your solar inverter, this breaker protects the AC wiring running to your DB. For the DC side (panels to inverter), you need \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027;\"\u003eDC circuit breakers for solar\u003c\/a\u003e — not an AC MCB. Using an AC breaker on a DC solar circuit is dangerous because AC breakers cannot safely extinguish a DC arc.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eBackup power systems:\u003c\/strong\u003e Circuits fed by UPS, inverter, or \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027;\"\u003echangeover switch\u003c\/a\u003e from generator. Each circuit downstream gets a 1 pole MCB for individual protection.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eEV charging:\u003c\/strong\u003e A 3.5kW home EV charger draws approximately 15A continuous at 230V — use a 32A MCB on a dedicated 6mm² cable run from the DB to the charging point.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eWhat This Breaker Does NOT Protect Against\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eAn MCB protects against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuit\u003c\/strong\u003e only. It does NOT protect against:\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eElectric shock \/ earth leakage\u003c\/strong\u003e — If you touch a live wire and current flows through your body (as little as 30mA), the MCB will NOT trip because 30mA is far below its rated current. You need an \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO earth leakage breaker\u003c\/a\u003e for shock protection. Every bathroom, kitchen, and outdoor circuit in Pakistan should have one.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eVoltage fluctuation\u003c\/strong\u003e — If WAPDA voltage spikes to 280V or drops to 140V, the MCB will not react. You need a \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;\"\u003evoltage protector (VA device)\u003c\/a\u003e to disconnect during over\/under voltage.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003e\u003cstrong\u003eLightning and surge\u003c\/strong\u003e — A nearby lightning strike can send thousands of volts through your wiring. The MCB will not stop this. You need an \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;\"\u003eSPD surge protection device\u003c\/a\u003e at your main panel.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eA properly protected Pakistani home DB has MCBs for circuit protection, an RCBO for shock protection, a VA protector for voltage issues, and an SPD for surge\/lightning protection. Browse our \u003ca href=\"\/collections\/solar-bundles\" style=\"color:#d42027;\"\u003esolar DB bundles\u003c\/a\u003e for pre-configured protection kits that include all of these.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eRelated Products\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0 16px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNeed both live and neutral disconnection? → \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027;\"\u003e2 Pole MCB 10A-63A\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNeed a compact 1P+N in one module? → \u003ca href=\"\/collections\/ac-breaker\" style=\"color:#d42027;\"\u003e1P+N MCB 10A-40A\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eHeavy load above 63A? → \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB Breakers 100A-1600A\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eThree-phase circuits? → \u003ca href=\"\/products\/cnc-4p-ac-mcb-circuit-breaker-ycb7h-63\" style=\"color:#d42027;\"\u003e3 Pole or 4 Pole MCB\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSolar DC side? → \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027;\"\u003eDC circuit breakers\u003c\/a\u003e (never use AC breaker on DC)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eEarth leakage protection? → \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027;\"\u003eRCBO breakers\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNeed a complete DB setup? → \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027;\"\u003eDB boxes\u003c\/a\u003e + circuit breakers\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRead our guide → \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027;\"\u003eTypes of Circuit Breakers in Pakistan — Complete Guide\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin:32px 0 14px 0;color:#111;line-height:1.3;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is MCB full form? What does MCB stand for in electrical?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eMCB stands for Miniature Circuit Breaker. It is a compact, DIN-rail mounted safety breaker that automatically disconnects the circuit during overload or short-circuit conditions. In Pakistan, electricians and shopkeepers often call it a \"safety breaker\" or simply \"breaker switch\" — these all refer to the same device. The MCB replaced traditional rewirable fuses because it can be reset after tripping instead of needing wire replacement.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is the 63 amp circuit breaker price in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eThe CNC 1 Pole 63A MCB is available at Rs.425 at CNC Electric Pakistan. Competitor brands like Schneider Domae single pole MCB typically cost Rs.950-1,150, and Chint NXB-63 costs Rs.500-550. CNC offers comparable IEC 60898-1 certified performance at a lower price point, with a 5-year replacement warranty included.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat size breaker do I need for a 1.5 ton inverter AC?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eA 1.5 ton inverter AC draws approximately 7-8 amps running but has compressor startup inrush of 25-35 amps. Use a \u003cstrong\u003e20A C-curve MCB\u003c\/strong\u003e on \u003cstrong\u003e4mm² cable\u003c\/strong\u003e for a dedicated circuit. The C-curve tolerates the momentary inrush without nuisance tripping. If your AC is a fixed-speed (non-inverter) unit, the inrush is higher — use a 25A MCB instead. Never put two ACs on the same breaker circuit.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhat is the difference between MCB and MCCB?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eMCB (Miniature Circuit Breaker) handles up to 63A with fixed trip curves — it's for branch circuits in homes and shops. MCCB (Molded Case Circuit Breaker) handles 100A-1600A with adjustable trip settings — it's for factory mains and commercial buildings where loads exceed 63A or fault levels exceed 6kA. For most Pakistani homes, MCBs are sufficient. If your total load exceeds 63A, see our \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027;\"\u003eMCCB breakers\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eIs MCB the same thing as a safety breaker?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eYes. In Pakistan, \"safety breaker\" is the common name for what engineers call an MCB (miniature circuit breaker). Other common names: breaker switch, electric breaker, trip switch, circuit breaker. They all refer to the same device — a compact breaker that mounts on a DIN rail inside your DB box and automatically trips when current exceeds safe limits.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eCan I use this AC breaker for my solar panels?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eNo. This is an AC breaker rated for 230V AC circuits. Solar panels produce DC (direct current), and DC circuits require purpose-built \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027;\"\u003eDC circuit breakers\u003c\/a\u003e. Using an AC MCB on a DC solar circuit is dangerous — the breaker may fail to extinguish the DC arc during a fault, leading to sustained arcing, overheating, and potential fire. For the AC output side of your solar inverter, this MCB is appropriate.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eWhy does my MCB keep tripping?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eCommon causes in Pakistan: (1) \u003cstrong\u003eOverloaded circuit\u003c\/strong\u003e — too many appliances on one breaker. Add up the amps and check if total exceeds the breaker rating. (2) \u003cstrong\u003eWrong breaker size\u003c\/strong\u003e — a 10A breaker on an AC circuit will trip every time the compressor starts. (3) \u003cstrong\u003eShort circuit\u003c\/strong\u003e — damaged wiring, water in a junction box, or a faulty appliance. Unplug everything and reset — if it trips immediately with nothing connected, the fault is in the wiring. (4) \u003cstrong\u003eHigh ambient temperature\u003c\/strong\u003e — in Pakistani summers (45-50°C), DB box temperatures can reach 60°C. At these temperatures, an MCB derates by 10-20%, meaning a 10A MCB may trip at 8-9A. This is normal physics, not a defect — either upsize the breaker or improve panel ventilation. Pair with an \u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027\"\u003eaerosol fire extinguisher\u003c\/a\u003e for added panel safety. For over and under voltage protection, add a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protector\u003c\/a\u003e to your board.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin:22px 0 8px 0;color:#111;\"\u003eCNC breaker vs Schneider — which is better?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 18px 0;\"\u003eBoth CNC and Schneider manufacture MCBs to the same IEC 60898-1 standard with 6kA breaking capacity at 230V. Schneider (Domae series) is a well-known European brand with higher pricing (Rs.950-1,150 for a single pole 63A). CNC offers the same certified performance at approximately 50-60% lower price (Rs.425 for single pole 63A) with a 5-year warranty. For residential and light commercial use in Pakistan, either brand provides reliable protection — the choice depends on budget and brand preference.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:8px\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/ac-breaker-size-guide-pakistan-air-conditioner-hybrid-solar-inverter\" style=\"color:#d42027\"\u003eAC Breaker Size Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"cnc-related-blog\" style=\"margin-top:1.5em;padding:1em;background:#f8f9fa;border-left:4px solid #fa3433;border-radius:6px;\"\u003e\u003cstrong\u003e📖 Related Reading:\u003c\/strong\u003e \u003ca href=\"\/blogs\/news\/difference-between-mcb-mccb-and-acb-circuit-breakers-complete-guide\" title=\"MCB Full Form: What is Miniature Circuit Breaker \u0026amp; How to Choose in Pakistan (2026 Guide)\" style=\"color:#fa3433;font-weight:600;\"\u003eMCB Full Form: What is Miniature Circuit Breaker \u0026amp; How to Choose in Pakistan (2026 Guide)\u003c\/a\u003e — In-depth guide on this product category. \u003cbr\u003e\u003cem\u003eHelpful for understanding sizing, installation, and choosing the right model for your Pakistan setup.\u003c\/em\u003e\u003c\/p\u003e","brand":"CNC ELECTRIC","offers":[{"title":"2A","offer_id":42324173226050,"sku":"YCB7-63N","price":450.0,"currency_code":"PKR","in_stock":true},{"title":"6A","offer_id":42324173258818,"sku":"YCB7-63N","price":450.0,"currency_code":"PKR","in_stock":true},{"title":"10A","offer_id":42324173291586,"sku":"YCB7-63N","price":450.0,"currency_code":"PKR","in_stock":true},{"title":"16A","offer_id":42324173324354,"sku":"YCB7-63N","price":450.0,"currency_code":"PKR","in_stock":true},{"title":"20A","offer_id":42324173357122,"sku":"YCB7-63N","price":450.0,"currency_code":"PKR","in_stock":true},{"title":"25A","offer_id":42460750872642,"sku":null,"price":450.0,"currency_code":"PKR","in_stock":true},{"title":"32A","offer_id":42324173389890,"sku":"YCB7-63N","price":450.0,"currency_code":"PKR","in_stock":true},{"title":"40A","offer_id":42324173422658,"sku":"YCB7-63N","price":450.0,"currency_code":"PKR","in_stock":true},{"title":"63A","offer_id":42324173455426,"sku":"YCB7-63N","price":450.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/1Pole_63A_MCB_AC_Circuit_Breaker-4.webp?v=1756708222"},{"product_id":"cnc-1p-n-rcbo-reliable-residual-current-circuit-protection","title":"RCBO 1P+N 32A-63A | Earth Leakage Breaker","description":"\u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin-bottom:20px\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eNot sure which voltage protector you need?\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eTry our \u003ca href=\"\/pages\/voltage-protector-finder\" style=\"color:#d42027;font-weight:700\"\u003eVA Protector Product Finder Tool\u003c\/a\u003e — Pakistan's first interactive selector.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eRCBO 1P+N is the smart choice for single-phase circuits in Pakistan when you need earth leakage breaker protection and overload protection in one device. This CNC Electric Pakistan RCBO is available from 16A to 63A with 30mA sensitivity, giving both shock protection and circuit protection on one DIN rail module solution. Starting from Rs.1,700, it is ideal for home circuits feeding ACs, geysers, washing machines, water pumps, kitchen sockets, UPS lines, and other loads in Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, and Peshawar.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eQuick Specs\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eRCBO 1P+N 32A-63A \/ single phase earth leakage breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e1P+N (phase + neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eAmp Ratings\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e16A, 20A, 25A, 32A, 40A, 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eEarth Leakage Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eProtection Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eEarth leakage + overload + short circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eIEC 61009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eTypical Application\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eSingle-phase home and small commercial circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eAn RCBO combines the job of an MCB and an RCCB into one unit. That means it trips if there is overload or short circuit, and it also trips if electricity starts leaking to earth, which can happen because of damaged wiring, wet environments, or faulty appliances. People searching for \u003cstrong\u003ercbo\u003c\/strong\u003e, \u003cstrong\u003ercbo breaker\u003c\/strong\u003e, \u003cstrong\u003eearth leakage breaker\u003c\/strong\u003e, or \u003cstrong\u003eearth leakage circuit breaker\u003c\/strong\u003e usually want exactly this combined protection.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eOn a Pakistani home distribution board, an RCBO is especially useful for circuits that feed washing machines, kitchen sockets, water dispenser outlets, bathroom geyser lines, outdoor plugs, water pumps, inverter input circuits, and room ACs. If a person touches a faulty appliance body or if moisture causes leakage current, the 30mA sensitivity can disconnect the circuit quickly. At the same time, the RCBO still behaves like a circuit breaker for overload and short-circuit events.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eCompared with using a separate \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027\"\u003eRCCB\u003c\/a\u003e plus a separate \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003eMCB\u003c\/a\u003e, the RCBO saves space and makes one-circuit protection simpler. If you only need overcurrent protection, a regular \u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027\"\u003e2P MCB\u003c\/a\u003e may be enough. If you need both shock protection and overload protection on one single-phase circuit, the RCBO is usually the better answer.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhere an RCBO Makes the Biggest Difference\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIn Pakistan, voltage fluctuation gets a lot of attention, but leakage faults are just as serious because they can injure people. A damaged water pump cable, a metal-body washing machine with internal leakage, a damp outdoor socket, or a poorly insulated geyser line can all create dangerous conditions. The RCBO helps reduce that risk on one circuit without forcing you to redesign the entire board.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor example, a 1 ton AC or 1.5 ton AC circuit may only need an MCB for overload, but if the installation location is exposed to moisture or there is user contact risk, RCBO protection becomes much more attractive. The same applies to laundry areas, outdoor kitchens, roof-top socket lines, and any place where human contact and leakage risk are higher.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSelection Guide\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eAppliance \/ Circuit\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eRecommended Rating\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSmall dedicated socket circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e16A or 20A RCBO\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eSuitable for light single-phase loads and shock protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eKitchen or utility socket line\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e20A or 25A RCBO\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eUseful where leakage risk is higher because of appliances and moisture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWashing machine \/ small pump line\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e20A or 25A RCBO\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eGood mix of load handling and earth leakage safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e1 ton AC or similar dedicated circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e20A or 25A RCBO\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eDepends on actual cable and load design by electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e1.5 ton AC \/ larger dedicated line\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e25A or 32A RCBO\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften selected where extra starting current margin is needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eHeavier single-phase feeder\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e40A or 63A RCBO\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eFor larger sub-circuits, always size by cable and actual load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Install\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eAn RCBO should be installed by a licensed electrician because both the phase and neutral path must be handled correctly and test functionality should be checked after wiring.\u003c\/p\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eTurn off the main supply and confirm zero voltage before starting work.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eMount the RCBO on the DIN rail inside the DB board.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eConnect incoming and outgoing phase and neutral exactly according to the product markings.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eAfter energizing, use the test button to confirm the RCBO trips correctly.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003eLabel the protected circuit clearly so future maintenance is easy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis RCBO does \u003cstrong\u003enot\u003c\/strong\u003e protect against voltage spikes or lightning surges, so add an \u003ca href=\"\/products\/cnc-ac-spd-2p-275v-surge-protection-devices-20ka-40ka-ycs6-c\" style=\"color:#d42027\"\u003eAC SPD\u003c\/a\u003e if surge risk exists. It does \u003cstrong\u003enot\u003c\/strong\u003e manage sustained overvoltage or undervoltage caused by weak utility supply, so use a \u003ca href=\"\/products\/cnc-2p-voltage-protection-device-1-80a-yc7va\" style=\"color:#d42027\"\u003eVA protector\u003c\/a\u003e if you need that function. It is also for single-phase circuits, not for three-phase systems where a \u003ca href=\"\/products\/cnc-4p-rcbo-residual-current-circuit-breaker-ycb6hln-63\" style=\"color:#d42027\"\u003e4P RCCB\u003c\/a\u003e or a three-phase protection design is needed.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003ePut simply, RCBO covers one important package: earth leakage plus overcurrent on a single-phase line. For complete board protection, combine it with \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003eSPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protectors\u003c\/a\u003e, appropriate \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003eMCBs\u003c\/a\u003e, and the right \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027\"\u003eDB box\u003c\/a\u003e layout.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCNC vs Schneider and Local Brands\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eCNC\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSchneider\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eLocal Brands\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eTypical price in Pakistan\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eStarting from Rs.1,700\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eUsually significantly higher\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eCan be cheaper but protection quality varies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eProtection functions\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLeakage + overload + short circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eAvailable in premium ranges\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eSome generics lack reliable trip behavior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eStandards\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eIEC 61009\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eStrong brand reputation\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eSpecification consistency may be unclear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eValue for homes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eHigh feature-to-price value\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003ePremium choice\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eLower upfront cost, higher trust risk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003e5-year warranty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eChannel dependent\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;background:#f9f9f9\"\u003eOften limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCross-Category Recommendations\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIf you are buying this RCBO, also consider the parts that complete a safe single-phase board. For incoming voltage control, add a \u003ca href=\"\/products\/cnc-2p-voltage-protection-device-1-80a-yc7va\" style=\"color:#d42027\"\u003eVA protector\u003c\/a\u003e. For lightning and transient surge protection, add an \u003ca href=\"\/products\/cnc-ac-spd-2p-275v-surge-protection-devices-20ka-40ka-ycs6-c\" style=\"color:#d42027\"\u003eAC SPD\u003c\/a\u003e. If your project is three-phase, compare the \u003ca href=\"\/products\/cnc-4p-rcbo-residual-current-circuit-breaker-ycb6hln-63\" style=\"color:#d42027\"\u003e4P RCCB\u003c\/a\u003e. Read the \u003ca href=\"\/blogs\/guides\/rccb-breaker-guide-pakistan-earth-leakage-protection\" style=\"color:#d42027\"\u003eRCBO vs ELCB guide\u003c\/a\u003e and \u003ca href=\"\/blogs\/guides\/types-of-circuit-breakers\" style=\"color:#d42027\"\u003etypes of circuit breakers\u003c\/a\u003e to help sales staff and electricians explain the difference to customers.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBrowse \u003ca href=\"\/collections\/cables\" style=\"color:#d42027\"\u003eMC4 connectors\u003c\/a\u003e, \u003ca href=\"\/collections\/cables\" style=\"color:#d42027\"\u003eDC cables\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027\"\u003eDC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027\"\u003eDC SPD collection\u003c\/a\u003e, \u003ca href=\"\/collections\/solar-bundles\" style=\"color:#d42027\"\u003esolar bundles\u003c\/a\u003e, \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003eAC circuit breakers\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003eAC SPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027\"\u003eRCCB and RCBO\u003c\/a\u003e, \u003ca href=\"\/collections\/changeovers\" style=\"color:#d42027\"\u003emanual changeover switches\u003c\/a\u003e, \u003ca href=\"\/collections\/ats\" style=\"color:#d42027\"\u003eautomatic transfer switches\u003c\/a\u003e, \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027\"\u003eDB boxes\u003c\/a\u003e, and \u003ca href=\"\/collections\/ac-mccb-breakers\" style=\"color:#d42027\"\u003eMCCBs\u003c\/a\u003e for complete protection planning.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products from CNC Electric\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px\"\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-4p-rcbo-residual-current-circuit-breaker-ycb6hln-63\" style=\"color:#d42027\"\u003e4P RCCB\u003c\/a\u003e — Rs.2,800+\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-2p-mcb-ac-circuit-breaker-500v-ycb7h-63\" style=\"color:#d42027\"\u003e2P MCB\u003c\/a\u003e — Rs.850\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-2p-voltage-protection-device-1-80a-yc7va\" style=\"color:#d42027\"\u003eVA Protector\u003c\/a\u003e — Rs.1,700\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px\"\u003e\n\u003ca href=\"\/products\/cnc-ac-spd-2p-275v-surge-protection-devices-20ka-40ka-ycs6-c\" style=\"color:#d42027\"\u003eAC SPD 2P\u003c\/a\u003e — Rs.2,500\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is RCBO full form?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eRCBO stands for Residual Current Breaker with Overcurrent protection. It combines earth leakage protection and circuit breaker protection in one unit.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is rcbo price in pakistan for this model?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis CNC Electric Pakistan RCBO starts from Rs.1,700, depending on the amp rating selected.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the difference between RCCB and RCBO?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eAn RCCB mainly covers leakage protection and usually needs an MCB for overload. An RCBO combines both functions in one device.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eCan I use this RCBO for an AC?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, if the selected amp rating matches the load and cable size. Many buyers use RCBOs on dedicated AC circuits where additional shock protection is desired.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes this protect from electric shock?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eIt helps protect against dangerous leakage current by tripping at 30mA sensitivity, but proper earthing, wiring quality, and correct installation still matter.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDoes RCBO replace a voltage protector?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eNo. It does not manage sustained overvoltage or undervoltage. Add a VA protector if you need voltage protection.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eDo I still need an SPD with an RCBO?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, if the site has surge risk. The RCBO does not replace an SPD for lightning-related transient protection.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this single phase or three phase?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis is 1P+N single phase. For three-phase installations, use the correct three-phase protective device such as a 4P RCCB or a suitable multi-pole arrangement.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhy choose CNC Electric Pakistan for RCBO?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eBecause it offers practical pricing, a 5-year warranty, free delivery, and matching products across the full protection range for Pakistani homes and projects.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor better board planning, compare \u003ca href=\"\/collections\/rccb\" style=\"color:#d42027\"\u003eRCCB\/RCBO\u003c\/a\u003e, \u003ca href=\"\/collections\/spd\" style=\"color:#d42027\"\u003eSPDs\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protectors\u003c\/a\u003e, \u003ca href=\"\/collections\/circuit-breakers\" style=\"color:#d42027\"\u003eMCBs\u003c\/a\u003e, and \u003ca href=\"\/collections\/db-boxes\" style=\"color:#d42027\"\u003eDB boxes\u003c\/a\u003e. CNC Electric Pakistan offers free delivery, 5-year warranty support, and practical advice for electricians and buyers across Pakistan. WhatsApp us at 0326-1111376. Pair with an \u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027\"\u003eaerosol fire extinguisher\u003c\/a\u003e for added panel safety.\u003c\/p\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:8px\"\u003eSee also: \u003ca href=\"\/blogs\/guides\/rccb-breaker-guide-pakistan-earth-leakage-protection\" style=\"color:#d42027\"\u003eRCCB Breaker Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC ELECTRIC","offers":[{"title":"32A","offer_id":42324173619266,"sku":null,"price":1750.0,"currency_code":"PKR","in_stock":true},{"title":"63A","offer_id":42324173652034,"sku":"YCB6HLE","price":1850.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/YCB7LE-63Y-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection.webp?v=1771053620"},{"product_id":"cnc-4p-wifi-smart-circuit-breaker-ycb9zf","title":"WiFi Breaker 4 Pole 100A | 3-Phase Smart MCB | CNC YCB9ZF","description":"\u003cp\u003eLooking for a \u003cstrong\u003eWiFi smart breaker 4 pole\u003c\/strong\u003e in Pakistan for a smart panel, remote site, commercial board, or controlled power-distribution setup? This CNC Electric \u003cstrong\u003eYCB9ZF-100W\u003c\/strong\u003e 4 pole smart circuit breaker is listed at \u003cstrong\u003eRs.12,400\u003c\/strong\u003e and is built for buyers who want more than manual switching at the panel. It combines 4-pole breaker protection with remote app control, operating records, warning functions, and smarter fault handling in one device.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e4 pole WiFi smart circuit breaker for multi-pole control and protection\u003c\/li\u003e\n\u003cli\u003eSingle 100A variant with 6kA short-circuit breaking capacity\u003c\/li\u003e\n\u003cli\u003eWiFi communication with phone-app control for remote switching, status, and visibility\u003c\/li\u003e\n\u003cli\u003eData monitoring, fault alarm, centralised management, rights management, regional search, and data-report generation\u003c\/li\u003e\n\u003cli\u003eOver-voltage, under-voltage, overload, over-temperature, voltage\/current imbalance, and fault-phase protection\u003c\/li\u003e\n\u003cli\u003eShort-circuit faults trip within 100ms\u003c\/li\u003e\n\u003cli\u003eManual and automatic integrated control — operate from the handle or from the app\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eWi-Fi 4 Pole Smart Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eYCB9ZF-100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (this listing)\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Capacity\u003c\/td\u003e\n\u003ctd\u003eIcn = Ics = 6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Characteristic\u003c\/td\u003e\n\u003ctd\u003eC type (others customisable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003eAC 230V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Operating Current\u003c\/td\u003e\n\u003ctd\u003e30–300mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Trip Response\u003c\/td\u003e\n\u003ctd\u003eWithin 100ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver\/Under Voltage Logic\u003c\/td\u003e\n\u003ctd\u003e3s default, 0–99s adjustable; threshold %-settable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;20,000 ops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;3,000 ops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Grade\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eWireless WiFi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e55 × 77 × 90mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eVariant \u0026amp; Price (Live on Shopify)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003cth\u003eCurrent\u003c\/th\u003e\n\u003cth\u003eTypical use\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYCB9ZF-100W\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003ctd\u003eRemote control and monitoring of larger smart-panel circuits and heavier controlled loads\u003c\/td\u003e\n\u003ctd\u003eRs.12,400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis page sells a \u003cstrong\u003esingle 100A variant\u003c\/strong\u003e. Lower-current smart breakers (single-pole or two-pole) are sold on separate pages — see related products below.\u003c\/p\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLarger smart distribution panels needing remote control and monitoring of a serious circuit\u003c\/li\u003e\n\u003cli\u003eCommercial buildings, service rooms, and managed properties in Lahore, Karachi, or Islamabad\u003c\/li\u003e\n\u003cli\u003eCritical feeder or controlled-load panels needing remote access, fault alarms, and centralised management\u003c\/li\u003e\n\u003cli\u003eProjects wanting electrical-fire monitoring, fault-location support, rights management, and remote diagnosis\u003c\/li\u003e\n\u003cli\u003eSmarter industrial and utility boards where voltage\/current imbalance and fault-phase warning add operational value\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Choose\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eYour need\u003c\/th\u003e\n\u003cth\u003eChoice\u003c\/th\u003e\n\u003cth\u003eReason\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-pole smart control at 100A\u003c\/td\u003e\n\u003ctd\u003eThis product (Rs.12,400)\u003c\/td\u003e\n\u003ctd\u003eOnly variant on this page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-pole 63A smart switching\u003c\/td\u003e\n\u003ctd\u003eWiFi 2P 63A (Rs.8,500)\u003c\/td\u003e\n\u003ctd\u003eSmaller single-phase branch control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-pole 100A with LCD display\u003c\/td\u003e\n\u003ctd\u003eWiFi 2P Display (Rs.42,000)\u003c\/td\u003e\n\u003ctd\u003eOn-device metering + remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-pole 100A with LCD display\u003c\/td\u003e\n\u003ctd\u003eWiFi 4P Display (Rs.43,500)\u003c\/td\u003e\n\u003ctd\u003eFull 3-phase smart with front panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eSmart Breaker vs Alternatives\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePoint\u003c\/th\u003e\n\u003cth\u003eCNC YCB9ZF 4P\u003c\/th\u003e\n\u003cth\u003ePlain 4P MCB\u003c\/th\u003e\n\u003cth\u003eNo-name WiFi relay\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eUsually yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaker-class protection\u003c\/td\u003e\n\u003ctd\u003e6kA + V\/I\/temp\/imbalance\/phase\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eUsually not dependable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecords \u0026amp; alarms\u003c\/td\u003e\n\u003ctd\u003eFault logs, centralised mgmt\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eVaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrice\u003c\/td\u003e\n\u003ctd\u003eRs.12,400\u003c\/td\u003e\n\u003ctd\u003eLower\u003c\/td\u003e\n\u003ctd\u003eLower, higher support risk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp\u003eIt is not a full smart-building system by itself. It is not an SPD and does not replace dedicated surge protection. It does not replace full RCCB\/RCBO strategy where residual-current protection is required. It does not fix poor earthing, bad WiFi coverage, weak enclosure design, or incorrectly sized feeder circuits.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the circuit really needs a 4-pole smart breaker and suits the 100A rating.\u003c\/li\u003e\n\u003cli\u003eInstall the breaker inside a proper DB box or smart-panel enclosure with clear circuit identification.\u003c\/li\u003e\n\u003cli\u003eWire and commission locally first before relying on remote control.\u003c\/li\u003e\n\u003cli\u003ePair with the mobile app and verify switching, monitoring, and status feedback under controlled conditions.\u003c\/li\u003e\n\u003cli\u003eTest trip logic, warning thresholds, and remote\/manual interaction safely before handover.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/wi-fi-2-pole-smart-circuit-breaker-63a-ycs1-63wj\"\u003eWiFi 2P 63A Smart Breaker\u003c\/a\u003e — Rs.8,500\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/wi-fi-2-pole-smart-circuit-breaker-with-display-remote-power-monitoring\"\u003eWiFi 2P Display 100A\u003c\/a\u003e — Rs.42,000\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/wi-fi-4-pole-smart-circuit-breaker-with-display-remote-power-monitoring\"\u003eWiFi 4P Display 100A\u003c\/a\u003e — Rs.43,500\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/spd\"\u003eSurge Protection Devices\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/voltage-protectors\"\u003eVoltage Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/db-boxes\"\u003eDB Boxes\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the price?\u003c\/strong\u003e\u003cbr\u003eRs.12,400 for the 4 pole 100A YCB9ZF-100W on the live CNC Electric Pakistan page.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich ratings are available on this page?\u003c\/strong\u003e\u003cbr\u003eOnly one: 4P 100A. Other currents are not stocked on this listing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I control it from my phone?\u003c\/strong\u003e\u003cbr\u003eYes. Voltage and switching status can be checked through the app, and the breaker supports remote control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it still work manually?\u003c\/strong\u003e\u003cbr\u003eYes — manual\/automatic integrated control including handle-based local operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreaking capacity?\u003c\/strong\u003e\u003cbr\u003e6kA short-circuit breaking capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOver\/under voltage protection?\u003c\/strong\u003e\u003cbr\u003eYes — trip after 3s by default, adjustable timing and threshold settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical fire monitoring?\u003c\/strong\u003e\u003cbr\u003eYes — early warning, fault location, fault alarm, and tripping protection are listed on the page.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it replace SPD and RCCB?\u003c\/strong\u003e\u003cbr\u003eNo. A proper panel may still need RCCB\/RCBO, SPD, metering, and other coordinated devices.\u003c\/p\u003e\n\n\u003cp\u003eFor stock confirmation, panel matching, or pairing advice, contact CNC Electric Pakistan on WhatsApp \u003cstrong\u003e0326-1111376\u003c\/strong\u003e. Orders above Rs.10,000 qualify for free delivery.\u003c\/p\u003e\n\n\u003cp class=\"cnc-related-blog\" style=\"margin-top:1.5em;padding:1em;background:#f8f9fa;border-left:4px solid #fa3433;border-radius:6px;\"\u003e\u003cstrong\u003e📖 Related Reading:\u003c\/strong\u003e \u003ca href=\"\/blogs\/news\/wifi-smart-breaker-vs-normal-breaker-pakistan-comparison\" title=\"WiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\" style=\"color:#fa3433;font-weight:600;\"\u003eWiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\u003c\/a\u003e — In-depth guide on this product category. \u003cbr\u003e\u003cem\u003eHelpful for understanding sizing, installation, and choosing the right model for your Pakistan setup.\u003c\/em\u003e\u003c\/p\u003e","brand":"CNC ELECTRIC","offers":[{"title":"55*77*90mm \/ 100A","offer_id":42324173684802,"sku":"YCB9ZF-100A","price":12400.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/4P_WiFi_Smart_Circuit_Breaker.webp?v=1755859139"},{"product_id":"dc-4-pole-mcb-miniature-circuit-breaker-1500v-32a","title":"DC 4 Pole MCB 1500V | Solar PV Breaker","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eDC MCB 4 pole 1500V is used where a solar DC circuit needs compact overcurrent protection instead of a larger MCCB. This 32A model is listed at Rs.3,800 on CNC Electric Pakistan. It suits PV strings, combiner boxes, battery-linked DC boards, and other high-voltage DC circuits where overload, short circuit, and safe isolation matter.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin:10px 0;padding-left:20px;font-size:15px;line-height:1.6\"\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e4 pole DC MCB for solar and other high-voltage DC circuits.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e1500V DC working-voltage class for the listed product family.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e32A local sale variant at Rs.3,800.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003e6kA breaking capacity published on the product page.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eOverload, short circuit, and isolation protection.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eDIN rail installation for combiner boxes and DC panels.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eBuilt for photovoltaic, industrial, civil, and communication DC use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDC miniature circuit breaker, 4 pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRated current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e32A local sale variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMaximum working voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDC1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCurrent range in family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUp to 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBreaking capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eStandard DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eWiring capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e2.5-25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTerminal torque\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e3.5 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e-35°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eElectrical life\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eUp to 10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDimensions \/ full drawing\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eContact us: 0326-1111376\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eVariant\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eVoltage\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePrice\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDC1500V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.3,800\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHigher-voltage PV strings and combiner protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e4P 1000V family option\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDC1000V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSee \u003ca href=\"\/products\/cnc-4-pole-mcb-dc-circuit-breakers-1000v-ycb8-63pv\" style=\"color:#d42027;\"\u003eproduct page\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLower-voltage PV and DC circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1P 500V family option\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDC500V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSee \u003ca href=\"\/products\/cnc-dc-1-pole-125a-mcb-circuit-breakers-500v-ycb8s-125pv\" style=\"color:#d42027;\"\u003eproduct page\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLower-voltage battery and DC panel circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis breaker fits higher-voltage solar work where a compact DIN-rail breaker still makes sense. Typical jobs include PV combiner boxes, rooftop solar strings, communication DC circuits, and battery-linked DC boards. In Lahore and Karachi, this is the kind of product used when installers need a compact 4-pole DC breaker for PV isolation and fault protection instead of moving straight to a larger molded-case unit.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eUse case\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eRecommended variant\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1500V PV string protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eThis 32A 4P 1500V version\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCorrect voltage class with DIN-rail convenience\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e1000V solar combiner box\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e\u003ca href=\"\/products\/cnc-4-pole-mcb-dc-circuit-breakers-1000v-ycb8-63pv\" style=\"color:#d42027;\"\u003e4P 1000V DC MCB\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBetter fit if 1500V class is not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBattery-linked lower-voltage DC board\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e\u003ca href=\"\/products\/cnc-dc-1-pole-125a-mcb-circuit-breakers-500v-ycb8s-125pv\" style=\"color:#d42027;\"\u003e1P 500V DC breaker\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eSmaller circuit and lower voltage need\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eHow to Choose\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eYour need\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eThis product?\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eBetter alternative\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCompact 1500V PV breaker\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed heavier frame and higher fault-duty control\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eMaybe not\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e\u003ca href=\"\/collections\/dc-mccb-breaker\" style=\"color:#d42027;\"\u003eDC MCCB breakers\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNeed fuse-based string protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003e\u003ca href=\"\/collections\/fuses\" style=\"color:#d42027;\"\u003eDC fuses\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eDC MCB vs Alternatives\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003ePoint\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eThis DC MCB\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eDC MCCB\u003c\/th\u003e\n\u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700;font-size:15px;line-height:1.6\"\u003eDC fuse setup\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eTypical price\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eRs.3,800\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHigher\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eLower for fuse only, plus holder cost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9\"\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eBest use\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eCompact DIN-rail PV protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eHigher-frame industrial DC duty\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eString-level fuse protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eInstallation\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eDIN rail\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003ePanel-mounted larger breaker\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #d0d0d0;font-size:15px;line-height:1.6\"\u003eFuse holder and replacement fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis DC MCB does not replace a \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027;\"\u003eDC SPD\u003c\/a\u003e, a correctly sized \u003ca href=\"\/collections\/fuses\" style=\"color:#d42027;\"\u003eDC fuse\u003c\/a\u003e, or the right \u003ca href=\"\/collections\/dc-isolator\" style=\"color:#d42027;\"\u003eDC isolator\u003c\/a\u003e where the design calls for them. It also does not fix poor string design, wrong polarity work, or undersized cable. For full datasheet, accessory fitment, or project selection help: WhatsApp 0326-1111376.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n\u003col style=\"margin:10px 0;padding-left:20px;font-size:15px;line-height:1.6\"\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eMount on standard DIN rail inside a suitable DC enclosure.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eConfirm string voltage and current before selecting the breaker.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eUse the correct cable size and tighten terminals to the published torque.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;font-size:15px;line-height:1.6\"\u003eLabel polarity and test isolation before commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cdiv style=\"background:#fff3f3;border:2px solid #d42027;border-radius:8px;padding:15px;margin:20px 0\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin:0\"\u003eAdd Fire Protection to Your Panel\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin:5px 0 0\"\u003eProtect your panel with a \u003ca href=\"\/products\/cnc-aerosol-fire-extinguisher-din-rail-for-switchgear-distribution-box\" style=\"color:#d42027;font-weight:700\"\u003eDIN Rail Aerosol Fire Extinguisher\u003c\/a\u003e — only Rs.2,500. Auto activation. 10-year shelf life. \u003ca href=\"\/blogs\/guides\/fire-extinguisher-electrical-panels-guide-pakistan\" style=\"color:#d42027\"\u003eFire safety guide →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n\u003cdiv style=\"margin-top:25px;padding:15px;background:#f9f9f9;border:1px solid #e0e0e0;border-radius:5px;\"\u003e\n\u003cp style=\"font-size:16px;font-weight:700;margin-bottom:10px;\"\u003eComplete Your Electrical Setup\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e⚡ \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027;\"\u003eDC SPD\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🔌 \u003ca href=\"\/collections\/dc-isolator\" style=\"color:#d42027;\"\u003eDC Isolators\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📦 \u003ca href=\"\/collections\/solar-bundles\" style=\"color:#d42027;\"\u003eSolar Bundles\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🧰 \u003ca href=\"\/collections\/fuses\" style=\"color:#d42027;\"\u003eDC Fuses\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🔋 \u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027;\"\u003eDC Breakers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e🛡️ \u003ca href=\"\/collections\/dc-mccb-breaker\" style=\"color:#d42027;\"\u003eDC MCCB Breakers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:6px;\"\u003e📖 \u003ca href=\"\/blogs\/news\/dc-breaker-complete-guide-to-dc-circuit-breakers-for-solar-battery-low-voltage-systems\" style=\"color:#d42027;\"\u003eDC Breaker Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:15px;margin-bottom:0;\"\u003e☀️ \u003ca href=\"\/blogs\/guides\/solar-db-box-guide-everything-pakistan-installers-need-to-know\" style=\"color:#d42027;\"\u003eSolar DB Box Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.6;margin-top:12px;margin-bottom:12px\"\u003eYou can also pair this breaker with a \u003ca href=\"\/collections\/cables\" style=\"color:#d42027;\"\u003eDC cable\u003c\/a\u003e, the right \u003ca href=\"\/products\/dc-fuse-20a-32a-1500v-solar-fuse-holder-for-pv-systems\" style=\"color:#d42027;\"\u003e1500V solar fuse\u003c\/a\u003e, and a matching \u003ca href=\"\/products\/cnc-dc-1500v-fuse-with-1p-holder-20a-solar-short-circuit-protection\" style=\"color:#d42027;\"\u003e1500V fuse holder\u003c\/a\u003e for a cleaner PV protection setup.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the price of this DC 4 pole MCB in Pakistan?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eRs.3,800.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs this suitable for solar?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes. It is built for photovoltaic DC protection.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat voltage class does it support?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eDC1500V.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the local amp variant?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003e32A.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhat is the breaking capacity?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003e6kA.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eIs it DIN rail mounted?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eShould I use an SPD as well?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eYes, use a \u003ca href=\"\/collections\/dc-spd\" style=\"color:#d42027;\"\u003eDC SPD\u003c\/a\u003e where surge protection is required.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;margin-top:20px;margin-bottom:8px\"\u003eWhere do I get the full datasheet?\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eWhatsApp 0326-1111376.\u003c\/p\u003e\n\n\u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eShop this DC MCB 4 pole 1500V from CNC Electric Pakistan for compact PV protection with DIN-rail installation and 6kA interruption. Free delivery over Rs.10,000. For full datasheet, project fitment, and bulk pricing, WhatsApp 0326-1111376.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"32A","offer_id":42460953903170,"sku":null,"price":3800.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/4P_63A_DC_MCB_Circuit_Breaker_1000V.webp?v=1755857009"},{"product_id":"wi-fi-2-pole-smart-circuit-breaker-63a-ycs1-63wj","title":"WiFi Breaker 2 Pole 63A | Energy Meter | CNC YCS1-63WJ","description":"\u003cp\u003e\u003cstrong\u003eWiFi 2 pole breaker\u003c\/strong\u003e price in Pakistan matters when a buyer wants more than a normal manual breaker. This CNC Electric \u003cstrong\u003eYCS1-63WJ\u003c\/strong\u003e is a 63A two-pole smart breaker sold locally at \u003cstrong\u003eRs.8,500\u003c\/strong\u003e, designed for remote control, monitoring and everyday circuit protection in one device. For homes, shops, office boards, water pumps, geysers and selected backup circuits, it gives one clear advantage: you can control the load without standing in front of the DB, while keeping breaker-style protection on the circuit.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e63A 2 pole smart breaker format for live + neutral switching on single-phase loads\u003c\/li\u003e\n\u003cli\u003eBuilt-in WiFi for remote open\/close via phone app\u003c\/li\u003e\n\u003cli\u003eOverload, short-circuit and leakage protection stated on the local page\u003c\/li\u003e\n\u003cli\u003eReal-time monitoring to watch circuit activity\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting for compact DB layouts\u003c\/li\u003e\n\u003cli\u003eSuitable for pumps, geysers, lighting groups, office circuits, inverter-fed branches\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eYCS1-63WJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2 Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrice\u003c\/td\u003e\n\u003ctd\u003eRs.8,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eRemote WiFi control, real-time monitoring, overload \/ short-circuit \/ leakage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003eAC 230V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eVariant \u0026amp; Price (Live on Shopify)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003cth\u003eCurrent\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYCS1-63WJ\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003eRs.8,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis page sells a single 2P 63A variant. For 1P, 4P, or display versions, see related products.\u003c\/p\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eA 2-pole WiFi breaker is most useful where remote convenience and branch-level control both matter. In Lahore, this often means a geyser line, roof pump, office lighting feeder, or villa sub-circuit. In Karachi, it suits water-pump circuits and shop boards where access is inconvenient. In Islamabad, it fits selected branch loads that need remote restart after power disturbance.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Choose\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eNeed\u003c\/th\u003e\n\u003cth\u003ePick\u003c\/th\u003e\n\u003cth\u003eReason\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimple single-pole remote\u003c\/td\u003e\n\u003ctd\u003e1P WiFi breaker\u003c\/td\u003e\n\u003ctd\u003eCheaper if one pole is enough\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2P 63A smart control + monitoring\u003c\/td\u003e\n\u003ctd\u003eThis product (Rs.8,500)\u003c\/td\u003e\n\u003ctd\u003eExact local position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront-panel LCD display\u003c\/td\u003e\n\u003ctd\u003eWiFi 2P Display (Rs.42,000)\u003c\/td\u003e\n\u003ctd\u003eOn-device metering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3-phase load\u003c\/td\u003e\n\u003ctd\u003eWiFi 4P 100A (Rs.12,400)\u003c\/td\u003e\n\u003ctd\u003eMulti-pole smart breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eSmart Breaker vs Alternatives — Why CNC?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePoint\u003c\/th\u003e\n\u003cth\u003eCNC WiFi 2P\u003c\/th\u003e\n\u003cth\u003ePlain 2P MCB\u003c\/th\u003e\n\u003cth\u003eCheap no-name app switch\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote ON\/OFF\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eVaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-time monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eOften missing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaker-style protection\u003c\/td\u003e\n\u003ctd\u003eOverload, short-circuit, leakage\u003c\/td\u003e\n\u003ctd\u003eYes but no smart layer\u003c\/td\u003e\n\u003ctd\u003eOften undocumented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrice\u003c\/td\u003e\n\u003ctd\u003eRs.8,500\u003c\/td\u003e\n\u003ctd\u003eLower\u003c\/td\u003e\n\u003ctd\u003eLower, higher support risk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp\u003eThis smart breaker does not replace a dedicated voltage protector where severe over\/under voltage is the main threat, and does not replace a proper SPD against lightning and switching surges. It is not the right class for three-phase loads or very high-current industrial feeders. It cannot fix loose terminations, undersized cable, poor earthing, or a badly designed branch.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eMount on DIN rail inside a dry, correctly built DB enclosure.\u003c\/li\u003e\n\u003cli\u003eConfirm the circuit is suitable for 2P 63A smart control.\u003c\/li\u003e\n\u003cli\u003eTerminate line and load conductors with clean stripping and proper tightening.\u003c\/li\u003e\n\u003cli\u003eCommission locally first, then pair the WiFi side and test open\/close\/status feedback.\u003c\/li\u003e\n\u003cli\u003eAdd a voltage protector and SPD where site conditions demand them.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/cnc-4p-wifi-smart-circuit-breaker-ycb9zf\"\u003eWiFi 4P 100A\u003c\/a\u003e — Rs.12,400\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/wi-fi-2-pole-smart-circuit-breaker-with-display-remote-power-monitoring\"\u003eWiFi 2P Display 100A\u003c\/a\u003e — Rs.42,000\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/spd\"\u003eSurge Protection Devices\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/voltage-protectors\"\u003eVoltage Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/db-boxes\"\u003eDB Boxes\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePrice?\u003c\/strong\u003e\u003cbr\u003eRs.8,500 for the 2P 63A YCS1-63WJ.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplaces a normal MCB?\u003c\/strong\u003e\u003cbr\u003eFor a suitable branch, yes — it adds remote control and monitoring while keeping breaker-style protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLeakage protection?\u003c\/strong\u003e\u003cbr\u003eListed on the local page. Exact trip thresholds are not published there.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGood for pumps?\u003c\/strong\u003e\u003cbr\u003eYes — remote visibility is especially useful for pumps on roofs or hard-to-reach service areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThree-phase machinery?\u003c\/strong\u003e\u003cbr\u003eNo. Use a 4P smart breaker instead.\u003c\/p\u003e\n\n\u003cp\u003eFor availability and setup help, WhatsApp \u003cstrong\u003e0326-1111376\u003c\/strong\u003e. Orders above Rs.10,000 qualify for free delivery.\u003c\/p\u003e\n\n\u003cp class=\"cnc-related-blog\" style=\"margin-top:1.5em;padding:1em;background:#f8f9fa;border-left:4px solid #fa3433;border-radius:6px;\"\u003e\u003cstrong\u003e📖 Related Reading:\u003c\/strong\u003e \u003ca href=\"\/blogs\/news\/wifi-smart-breaker-vs-normal-breaker-pakistan-comparison\" title=\"WiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\" style=\"color:#fa3433;font-weight:600;\"\u003eWiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\u003c\/a\u003e — In-depth guide on this product category. \u003cbr\u003e\u003cem\u003eHelpful for understanding sizing, installation, and choosing the right model for your Pakistan setup.\u003c\/em\u003e\u003c\/p\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"63A","offer_id":42487381426242,"sku":"YCS1-63WJ","price":8500.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Wi-Fi_2-Pole_Smart_Circuit_Breaker_63A_YCS1-63WJ.webp?v=1764157644"},{"product_id":"wi-fi-2-pole-smart-circuit-breaker-with-display-remote-power-monitoring","title":"WiFi 2 Pole Smart Breaker 100A | Display","description":"\u003cp\u003eThis \u003cstrong\u003e2 pole WiFi display breaker\u003c\/strong\u003e is listed in Pakistan at \u003cstrong\u003eRs.42,000\u003c\/strong\u003e and is built for buyers who want remote control plus live electrical feedback in one device. CNC Electric Pakistan offers this smart breaker for users who want app-based switching, on-device LCD visibility, and breaker-style protection on a single 2-pole 100A line. It suits higher-load circuits where a normal breaker gives protection but no monitoring.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2 pole smart breaker for heavier single-phase line control\u003c\/li\u003e\n\u003cli\u003eLCD display on the unit for direct viewing without opening another meter page\u003c\/li\u003e\n\u003cli\u003eRemote WiFi control from mobile app\u003c\/li\u003e\n\u003cli\u003eReal-time voltage, current, and power-use visibility\u003c\/li\u003e\n\u003cli\u003eProtection: overload, short-circuit, leakage\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting for panel-based electrical work\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eWiFi 2 pole smart circuit breaker with display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2 Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrice\u003c\/td\u003e\n\u003ctd\u003eRs.42,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eLCD display, remote WiFi control, real-time V\/I\/kWh monitoring, overload\/SC\/leakage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eExact short-circuit capacity, app ecosystem name, full dimensions, and wiring diagram are not currently listed on the live product page and have not been guessed.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eVariant \u0026amp; Price (Live on Shopify)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003cth\u003eCurrent\u003c\/th\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiFi 2P Display 100A\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003ctd\u003eLCD front panel\u003c\/td\u003e\n\u003ctd\u003eRs.42,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eSingle variant. For simpler 2P without display see the \u003ca href=\"\/products\/wi-fi-2-pole-smart-circuit-breaker-63a-ycs1-63wj\"\u003eWiFi 2P 63A (Rs.8,500)\u003c\/a\u003e. For 4P with display see the \u003ca href=\"\/products\/wi-fi-4-pole-smart-circuit-breaker-with-display-remote-power-monitoring\"\u003eWiFi 4P Display 100A (Rs.43,500)\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThis device is for higher-load single-phase circuits that benefit from both protection and visible monitoring. Generator-connected office circuits, large inverter-fed lines, heavy backup branches, commercial signage, water pumps, and backup-room lines where remote switching saves site visits.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Choose\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eNeed\u003c\/th\u003e\n\u003cth\u003ePick\u003c\/th\u003e\n\u003cth\u003eReason\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay + remote + 2P 100A\u003c\/td\u003e\n\u003ctd\u003eThis product (Rs.42,000)\u003c\/td\u003e\n\u003ctd\u003eDisplay-led option in this smart-breaker group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimpler 2P WiFi, lower cost\u003c\/td\u003e\n\u003ctd\u003eWiFi 2P 63A (Rs.8,500)\u003c\/td\u003e\n\u003ctd\u003eNo display, lighter duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3-phase with display\u003c\/td\u003e\n\u003ctd\u003eWiFi 4P Display (Rs.43,500)\u003c\/td\u003e\n\u003ctd\u003eTrue 4-pole version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnly ordinary protection\u003c\/td\u003e\n\u003ctd\u003eStandard 2P MCB\u003c\/td\u003e\n\u003ctd\u003eMuch cheaper if smart control is unnecessary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp\u003eIt does not replace a proper SPD, voltage protector, or RCD strategy. It does not fix poor earthing, undersized cable, generator instability, or lightning\/surge events. A smart breaker is not a substitute for proper circuit architecture.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eMount on DIN rail inside a clean enclosure with space for safe wiring and ventilation.\u003c\/li\u003e\n\u003cli\u003eConfirm line use and 2P switching format before final connection.\u003c\/li\u003e\n\u003cli\u003eKeep upstream and downstream protection logic clear — do not wire as a casual gadget.\u003c\/li\u003e\n\u003cli\u003eComplete app\/network setup only after the electrical side is verified.\u003c\/li\u003e\n\u003cli\u003eTest local operation, remote operation, display reading, and load response before handover.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/spd\"\u003eSurge Protection Devices\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/voltage-protectors\"\u003eVoltage Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/db-boxes\"\u003eDB Boxes\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/wifi-smart-circuit-breakers\"\u003eWiFi Smart Breakers\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePrice?\u003c\/strong\u003e\u003cbr\u003eRs.42,000 for the 2P 100A WiFi smart breaker with LCD display.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy more expensive than a normal WiFi breaker?\u003c\/strong\u003e\u003cbr\u003eBecause this is the display-led higher-end option. The cost covers the added monitoring and control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShows live voltage and current?\u003c\/strong\u003e\u003cbr\u003eYes — the LCD gives real-time voltage, current, and energy consumption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplaces SPD and voltage protector?\u003c\/strong\u003e\u003cbr\u003eNo. Pair with the correct SPD and voltage protector where site conditions need them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBetter than a smart plug?\u003c\/strong\u003e\u003cbr\u003eFor serious board-mounted work, yes — a smart plug is not the right class for higher-load circuits inside a DB.\u003c\/p\u003e\n\n\u003cp\u003eFor price confirmation, stock status, and selection help, WhatsApp \u003cstrong\u003e0326-1111376\u003c\/strong\u003e. Orders above Rs.10,000 qualify for free delivery.\u003c\/p\u003e\n\n\u003cp class=\"cnc-related-blog\" style=\"margin-top:1.5em;padding:1em;background:#f8f9fa;border-left:4px solid #fa3433;border-radius:6px;\"\u003e\u003cstrong\u003e📖 Related Reading:\u003c\/strong\u003e \u003ca href=\"\/blogs\/news\/wifi-smart-breaker-vs-normal-breaker-pakistan-comparison\" title=\"WiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\" style=\"color:#fa3433;font-weight:600;\"\u003eWiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\u003c\/a\u003e — In-depth guide on this product category. \u003cbr\u003e\u003cem\u003eHelpful for understanding sizing, installation, and choosing the right model for your Pakistan setup.\u003c\/em\u003e\u003c\/p\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"100A","offer_id":42487435722818,"sku":null,"price":42000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Wi-Fi_2_Pole_Circuit_Breaker_with_Display.webp?v=1770891306"},{"product_id":"wi-fi-4-pole-smart-circuit-breaker-with-display-remote-power-monitoring","title":"WiFi 4 Pole Smart Breaker 100A | Display","description":"\u003cp\u003e\u003cstrong\u003eWiFi 4 pole display breaker\u003c\/strong\u003e is the right choice when a normal smart switch is too light for the job and a plain 4 pole breaker gives you no visibility. On the live Pakistan page, this product is listed at \u003cstrong\u003eRs.43,500\u003c\/strong\u003e in a 100A version with remote ON\/OFF control, LCD monitoring, overload, short-circuit, and leakage protection. For buyers building a 3-phase board in Pakistan, that makes it a serious control-and-protection product, not just a convenience gadget.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e4 pole smart circuit breaker with display for 3-phase boards and solar-backed feeders\u003c\/li\u003e\n\u003cli\u003eLCD display with real-time voltage, current, and energy use\u003c\/li\u003e\n\u003cli\u003eRemote WiFi ON\/OFF via smartphone\u003c\/li\u003e\n\u003cli\u003eOverload, short-circuit, and leakage protection\u003c\/li\u003e\n\u003cli\u003eDIN-rail installation\u003c\/li\u003e\n\u003cli\u003eBuilt for 3-phase smart feeder control with front-end monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eWiFi 4 pole smart circuit breaker with display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e4 Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrice\u003c\/td\u003e\n\u003ctd\u003eRs.43,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eLocal display + WiFi remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay data\u003c\/td\u003e\n\u003ctd\u003eVoltage, current, energy consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eOverload, short-circuit, leakage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eExact app brand, short-circuit capacity, dimensions, and threshold menus are not currently listed on the live page and have not been guessed.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eVariant \u0026amp; Price (Live on Shopify)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003cth\u003eCurrent\u003c\/th\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiFi 4P Display 100A\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003ctd\u003eLCD front panel\u003c\/td\u003e\n\u003ctd\u003eRs.43,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eSingle variant. For 2P display see the \u003ca href=\"\/products\/wi-fi-2-pole-smart-circuit-breaker-with-display-remote-power-monitoring\"\u003eWiFi 2P Display 100A (Rs.42,000)\u003c\/a\u003e. For 4P without display see the \u003ca href=\"\/products\/cnc-4p-wifi-smart-circuit-breaker-ycb9zf\"\u003eWiFi 4P 100A (Rs.12,400)\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThis product is built for 3-phase boards and bigger consequences. Commercial three-phase utility rooms, small production lines, solar-backed three-phase panels, pumps, compressors, and building-service feeders where one normal breaker gives no visibility and a cheap WiFi relay gives too little protection.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Choose\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eNeed\u003c\/th\u003e\n\u003cth\u003ePick\u003c\/th\u003e\n\u003cth\u003eReason\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3-phase load + front monitoring\u003c\/td\u003e\n\u003ctd\u003eThis product (Rs.43,500)\u003c\/td\u003e\n\u003ctd\u003e4-pole display unit for serious feeders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3-phase smart control without display\u003c\/td\u003e\n\u003ctd\u003eWiFi 4P 100A (Rs.12,400)\u003c\/td\u003e\n\u003ctd\u003eMuch cheaper if display isn't needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-pole display smart breaker\u003c\/td\u003e\n\u003ctd\u003eWiFi 2P Display (Rs.42,000)\u003c\/td\u003e\n\u003ctd\u003eFor 2-pole applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlain isolation only\u003c\/td\u003e\n\u003ctd\u003eStandard 4P breaker\u003c\/td\u003e\n\u003ctd\u003eOverkill if remote control not needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n\u003cp\u003eIt does not replace a proper SPD against lightning and major surge events. It does not fix poor earthing, undersized cable, badly designed 3-phase boards, or wrong upstream coordination. It does not guarantee remote control if site WiFi is down.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eMount on correct DIN rail inside a rigid, properly ventilated panel.\u003c\/li\u003e\n\u003cli\u003eConfirm the feeder genuinely needs a 4-pole smart device.\u003c\/li\u003e\n\u003cli\u003eComplete wiring only after checking phase order, neutral handling, earthing, and upstream protection.\u003c\/li\u003e\n\u003cli\u003eSet up the remote-control side only after the power side is verified safe.\u003c\/li\u003e\n\u003cli\u003eTest local switching, remote switching, and displayed values before handover.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/spd\"\u003eSurge Protection Devices\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/voltage-protectors\"\u003eVoltage Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/db-boxes\"\u003eDB Boxes\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/wifi-smart-circuit-breakers\"\u003eWiFi Smart Breakers\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePrice?\u003c\/strong\u003e\u003cbr\u003eRs.43,500 for the 4P 100A WiFi smart breaker with LCD display.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy not a normal 4 pole breaker?\u003c\/strong\u003e\u003cbr\u003eBecause this adds remote ON\/OFF and front-end monitoring of voltage, current, and energy use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3-phase compatible?\u003c\/strong\u003e\u003cbr\u003eYes — the 4-pole design is exactly why buyers choose it for three-phase boards and solar-backed setups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShows live data on the front?\u003c\/strong\u003e\u003cbr\u003eYes — real-time voltage, current, and energy on the LCD.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplaces SPD or voltage protector?\u003c\/strong\u003e\u003cbr\u003eNo. It should be part of a proper board, not a substitute.\u003c\/p\u003e\n\n\u003cp\u003eCNC Electric Pakistan lists this at Rs.43,500 for the 100A variant. Breakers on the site carry a 5-year replacement warranty. WhatsApp \u003cstrong\u003e0326-1111376\u003c\/strong\u003e. Free delivery over Rs.10,000.\u003c\/p\u003e\n\n\u003cp class=\"cnc-related-blog\" style=\"margin-top:1.5em;padding:1em;background:#f8f9fa;border-left:4px solid #fa3433;border-radius:6px;\"\u003e\u003cstrong\u003e📖 Related Reading:\u003c\/strong\u003e \u003ca href=\"\/blogs\/news\/wifi-smart-breaker-vs-normal-breaker-pakistan-comparison\" title=\"WiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\" style=\"color:#fa3433;font-weight:600;\"\u003eWiFi Smart Breaker vs Normal MCB Pakistan | CNC Electric\u003c\/a\u003e — In-depth guide on this product category. \u003cbr\u003e\u003cem\u003eHelpful for understanding sizing, installation, and choosing the right model for your Pakistan setup.\u003c\/em\u003e\u003c\/p\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"100A","offer_id":42487481270338,"sku":null,"price":43500.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Wi-Fi_4_Pole_Smart_Circuit_Breaker_with_Display_Remote_Power_Monitoring.webp?v=1770892037"},{"product_id":"ac-3-pole-mccb-250a-ycm8yv","title":"MCCB 3 Pole 250A | Molded Case Breaker","description":"\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCNC Electric YCM8YV Series AC 50Hz Electronic Plastic MCCB (Molded Case Circuit Breaker)\u003c\/b\u003e is a high-performance \u003cb\u003eelectrical protection device\u003c\/b\u003e engineered for robust \u003cb\u003eAC circuit protection\u003c\/b\u003e in industrial, commercial, and heavy-duty power distribution systems. Designed and manufactured in compliance with \u003cb\u003eIEC60947-2 standards\u003c\/b\u003e, this molded case circuit breaker delivers reliable and precise protection against \u003cb\u003eoverload, short circuit, over-voltage, under-voltage, and phase loss conditions\u003c\/b\u003e in AC 50Hz electrical networks up to 400 V and rated currents up to 800 A making it ideal for a wide range of applications. \u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eSuperior Protection and Electrical Safety\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eThe \u003cb\u003eYCM8YV MCCB breaker\u003c\/b\u003e is engineered as a comprehensive protective device that goes beyond simple circuit interruption:.\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eOverload Protection:\u003c\/b\u003e Using an advanced thermal trip mechanism, the MCCB senses sustained over-current conditions and safely interrupts the circuit to protect conductors and equipment from overheating damage.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eInstant Short-Circuit Protection:\u003c\/b\u003e Featuring a magnetic trip response, it detects dangerous short-circuit faults and disconnects the circuit in milliseconds — preventing severe electrical faults and reducing the risk of fire or equipment failure.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003eVoltage Anomaly Safeguards:\u003c\/b\u003e Designed to guard against both \u003cb\u003eover-voltage and under-voltage events\u003c\/b\u003e, the YCM8YV protects sensitive electrical equipment from unstable supply conditions that can cause motor stress or operational disruption.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003ePhase Loss Protection:\u003c\/b\u003e In three-phase systems, the breaker detects phase loss scenarios and protects motors and loads from running under imbalance conditions, which can lead to overheating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eFlexible and Reliable Performance\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eWhat sets the \u003cb\u003eYCM8YV Series MCCB\u003c\/b\u003e apart is its blend of \u003cb\u003eprecision and adaptability\u003c\/b\u003e:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eElectronic Trip Unit:\u003c\/b\u003e The breaker’s electronic control delivers accurate and stable tripping performance that ensures protection without nuisance trips — ideal for systems with variable loads or frequent motor starts.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eWide Application Range:\u003c\/b\u003e Suitable for main power distribution boards, feeders, control panels, motor circuits, and switchgear assemblies in manufacturing plants, commercial buildings, renewable energy farms, and data centers.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003e\n\u003cb\u003eManual Switching Capability:\u003c\/b\u003e Beyond automatic protection, the MCCB also allows manual ON\/OFF operation for maintenance, emergency shutdowns, and commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eDurability \u0026amp; Build Quality\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eCrafted with a \u003cb\u003ehigh-grade electronic plastic casing\u003c\/b\u003e, the YCM8YV MCCB is rugged, lightweight, and resistant to environmental stress factors such as vibration, temperature fluctuations, and mechanical wear — contributing to long-term reliability and lower maintenance costs.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eStandards and Compliance\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eManufactured to meet international quality and safety benchmarks (IEC60947-2), the YCM8YV Series ensures consistent electrical safety performance, compatibility with global electrical systems, and peace of mind for installers, engineers, and end-users alike.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eKey Benefits at a Glance\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eRobust protection against \u003cb\u003eoverload, short circuit, and voltage irregularities\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eCompliance with \u003cb\u003eglobal safety standard IEC60947-2\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eAdvanced \u003cb\u003eelectronic trip unit\u003c\/b\u003e for precise fault interruption\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eManual ON\/OFF operation for maintenance and safety\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eIdeal for \u003cb\u003eindustrial, commercial, and heavy-duty power distribution\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list .5in;\"\u003eCompact, durable, and easy-to-install design\u003c\/li\u003e\n\u003c\/ul\u003e For over and under voltage protection, add a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protector\u003c\/a\u003e to your board.\n\u003cdiv style=\"margin-top:15px;font-size:14px\"\u003e\n\u003cstrong\u003e📖 Related Guides:\u003c\/strong\u003e\u003cul style=\"padding-left:18px;margin-top:5px\"\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/ac-mccb-breaker-complete-guide-to-moulded-case-circuit-breaker-features-applications\" style=\"color:#d42027\"\u003eMCCB Breaker Complete Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/mcb-full-form-what-is-mcb-miniature-circuit-breaker-working-principle-types\" style=\"color:#d42027\"\u003eMCB vs MCCB vs ACB Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"cnc-related-blog\" style=\"margin-top:1.5em;padding:1em;background:#f8f9fa;border-left:4px solid #fa3433;border-radius:6px;\"\u003e\u003cstrong\u003e📖 Related Reading:\u003c\/strong\u003e \u003ca href=\"\/blogs\/guides\/circuit-breaker-price-in-pakistan-complete-price-list-2026\" title=\"Circuit Breaker Price in Pakistan 2026 — Complete Price List MCB MCCB ACB\" style=\"color:#fa3433;font-weight:600;\"\u003eCircuit Breaker Price in Pakistan 2026 — Complete Price List MCB MCCB ACB\u003c\/a\u003e — In-depth guide on this product category. \u003cbr\u003e\u003cem\u003eHelpful for understanding sizing, installation, and choosing the right model for your Pakistan setup.\u003c\/em\u003e\u003c\/p\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"250A","offer_id":42803133415490,"sku":null,"price":18000.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/AC3PoleMCCBYCM8YVSeries.webp?v=1767079372"},{"product_id":"dc-mccb-125a-1000v-yem6","title":"DC MCCB 125A 1000V | Solar Circuit Breaker","description":"\u003cdiv style=\"font-family:system-ui,-apple-system,sans-serif;font-size:15px;line-height:1.6;color:#333\"\u003e\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eDC MCCB 125A 1000V | Solar Circuit Breaker\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe CNC Electric YeM6-125PV DC Molded Case Circuit Breaker (MCCB) is engineered to meet the demands of high-voltage direct current (DC) applications, including solar photovoltaic (PV) systems, battery banks, energy storage systems (ESS), and industrial DC distribution networks.\u003c\/p\u003e\n  \n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eKey Features\u003c\/h2\u003e\n  \u003cul style=\"font-size:15px;line-height:1.6;margin-bottom:12px;list-style-type:disc;padding-left:20px\"\u003e\n    \u003cli\u003eRated for up to DC 1000V and 125A, providing robust protection in solar and industrial applications.\u003c\/li\u003e\n    \u003cli\u003eProtects against overload, short circuit, and fault currents, ensuring system safety and reliability.\u003c\/li\u003e\n    \u003cli\u003eCompact design suitable for integration in various high-voltage DC setups.\u003c\/li\u003e\n    \u003cli\u003eEasy installation and maintenance with a user-friendly interface.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eDetails\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eDC 1000V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eRated Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003e125A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eBreaking Capacity\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eHigh\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eApplications\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eSolar PV, Battery Banks, ESS, DC Networks\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eProduct Range\u003c\/h2\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin:15px 0;font-size:15px;line-height:1.6\"\u003e\n    \u003ctr\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003eModel\u003c\/th\u003e\n      \u003cth style=\"background:#f0f0f0;padding:10px;border:1px solid #d0d0d0;text-align:left;font-weight:700\"\u003ePrice\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eYeM6-125PV\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #d0d0d0\"\u003eRs.4,000\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eApplications\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis DC MCCB is ideal for use in solar PV systems, protecting against overloads and short circuits. It is also suitable for battery banks, energy storage solutions, and other high-voltage DC applications, ensuring reliable performance and safety.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eSizing and Selection Guide\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eChoose this DC MCCB based on your system's voltage and current requirements. Ensure compatibility with existing setups for optimal performance. For assistance in selecting the right breaker, consult with our technical team.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eCompetitor Comparison\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eCompared to other DC MCCBs in the market, the CNC Electric YeM6-125PV offers competitive pricing and robust performance, making it a preferred choice for solar and industrial applications.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eWhat This Product Does NOT Protect Against\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThis DC MCCB does not protect against voltage fluctuations, lightning surges, or poor wiring practices. It does not replace an SPD or a voltage stabilizer and should be used in conjunction with these devices for comprehensive protection.\u003c\/p\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eFor a complete setup, pair it with the right \u003ca href=\"\/collections\/spd\" style=\"color:#d42027;font-weight:700\"\u003eSPD\u003c\/a\u003e, \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027;font-weight:700\"\u003evoltage protector\u003c\/a\u003e, and other relevant protection devices.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eInstallation Guide\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eEnsure installation is performed by a qualified electrician. Follow the manufacturer's guidelines for mounting and connection to ensure safety and compliance with electrical standards.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFire Extinguisher CTA\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eEnhance safety by keeping a suitable fire extinguisher nearby. Visit our \u003ca href=\"\/collections\/fire-extinguisher\" style=\"color:#d42027;font-weight:700\"\u003efire safety collection\u003c\/a\u003e for more information.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eRelated Products\u003c\/h2\u003e\n  \u003cul style=\"font-size:15px;line-height:1.6;margin-bottom:12px;list-style-type:disc;padding-left:20px\"\u003e\n    \u003cli\u003e\u003ca href=\"\/collections\/dc-breaker\" style=\"color:#d42027;font-weight:700\"\u003eSolar DC Breakers\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"\/collections\/solar-bundles\" style=\"color:#d42027;font-weight:700\"\u003eEnergy Storage Solutions\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"\/collections\/magnetic-contactors\" style=\"color:#d42027;font-weight:700\"\u003eIndustrial Control Products\u003c\/a\u003e\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eFAQs\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003e\u003cstrong\u003eQ: Can this MCCB be used in an AC system?\u003c\/strong\u003e\u003cbr\u003eA: No, this MCCB is specifically designed for DC applications.\u003c\/p\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003e\u003cstrong\u003eQ: What is the warranty period?\u003c\/strong\u003e\u003cbr\u003eA: The warranty period is typically one year from the date of purchase.\u003c\/p\u003e\n\n  \u003ch2 style=\"font-size:22px;font-weight:700;margin-top:25px;margin-bottom:10px\"\u003eConclusion\u003c\/h2\u003e\n  \u003cp style=\"font-size:15px;line-height:1.6;margin-bottom:12px\"\u003eThe CNC Electric DC MCCB 125A 1000V is an essential component for any high-voltage DC setup, providing reliable protection for solar PV systems and industrial applications. For more information, contact us via WhatsApp at \u003ca href=\"https:\/\/wa.me\/923001234567\" style=\"color:#d42027;font-weight:700\"\u003e+92 300 1234567\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-top:15px;font-size:14px\"\u003e\n\u003cstrong\u003e📖 Related Guides:\u003c\/strong\u003e\u003cul style=\"padding-left:18px;margin-top:5px\"\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/ac-mccb-breaker-complete-guide-to-moulded-case-circuit-breaker-features-applications\" style=\"color:#d42027\"\u003eMCCB Breaker Complete Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/mcb-full-form-what-is-mcb-miniature-circuit-breaker-working-principle-types\" style=\"color:#d42027\"\u003eMCB vs MCCB vs ACB Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"cnc-related-blog\" style=\"margin-top:1.5em;padding:1em;background:#f8f9fa;border-left:4px solid #fa3433;border-radius:6px;\"\u003e\u003cstrong\u003e📖 Related Reading:\u003c\/strong\u003e \u003ca href=\"\/blogs\/guides\/circuit-breaker-price-in-pakistan-complete-price-list-2026\" title=\"Circuit Breaker Price in Pakistan 2026 — Complete Price List MCB MCCB ACB\" style=\"color:#fa3433;font-weight:600;\"\u003eCircuit Breaker Price in Pakistan 2026 — Complete Price List MCB MCCB ACB\u003c\/a\u003e — In-depth guide on this product category. \u003cbr\u003e\u003cem\u003eHelpful for understanding sizing, installation, and choosing the right model for your Pakistan setup.\u003c\/em\u003e\u003c\/p\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"125A","offer_id":43009664843842,"sku":null,"price":4500.0,"currency_code":"PKR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/DC_MCCB_125A_1000V_YeM6-125PV.webp?v=1771486844"},{"product_id":"shunt-trip-release-for-mccb-remote-circuit-breaker","title":"MCCB 3 Pole 32A-1250A | Industrial Breaker","description":"\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eCNC Electric Shunt Trip Release Module\u003c\/b\u003e is a high-performance electrical accessory designed for \u003cb\u003eremote tripping of MCB and MCCB circuit breakers\u003c\/b\u003e in industrial, commercial, and residential power distribution systems. This compact and durable module allows automatic disconnection of power when connected to external control signals such as fire alarm systems, emergency stop buttons, voltage protection relays, or smart control panels.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBuilt with precision engineering and industrial-grade thermoplastic housing, this shunt trip unit ensures reliable breaker operation under critical fault conditions. It is widely used in \u003cb\u003eelectrical distribution boards, switchgear panels, control panels, and automation systems\u003c\/b\u003e where remote safety shutdown is required.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThis accessory enhances electrical safety by instantly disconnecting the breaker when voltage is applied to the shunt coil, preventing equipment damage, fire hazards, and overload risks.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eTop Features\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l2 level1 lfo4;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eDesigned for CNC Electric MCB \u0026amp; MCCB compatibility\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l2 level1 lfo4;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eEnables remote trip function for circuit breakers\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l2 level1 lfo4;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eFast response electromagnetic tripping mechanism\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l2 level1 lfo4;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eCompact DIN-rail compatible design\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l2 level1 lfo4;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eHigh durability industrial-grade housing\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l2 level1 lfo4;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eEasy wiring with pre-attached control wires\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l2 level1 lfo4;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eReliable performance in switchgear \u0026amp; distribution panels\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eProduct Type: Shunt Trip Release \/ Trip Coil Module\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eApplication: MCB \/ MCCB remote tripping\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eControl Voltage: Available in AC\/DC variants (model dependent)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eMounting Type: Side-mounted \/ DIN rail compatible\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eConnection Type: Pre-wired control leads\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eHousing Material: Flame-retardant thermoplastic\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo1; tab-stops: list .5in;\"\u003eInstallation: Panel mounted with breaker integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l3 level1 lfo3;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eElectrical Distribution Boards (DB Box)\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l3 level1 lfo3;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eIndustrial Control Panels\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l3 level1 lfo3;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eFire Alarm Interlock Systems\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l3 level1 lfo3;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eEmergency Power Shutdown Systems\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l3 level1 lfo3;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eGenerator \u0026amp; ATS Panels\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l3 level1 lfo3;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eVoltage Protection Relay Systems\u003c\/p\u003e\n\u003cp class=\"MsoListParagraph\" style=\"margin-left: 39.0pt; mso-add-space: auto; text-indent: -.25in; mso-list: l3 level1 lfo3;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eSolar Power Protection Systems\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eHow It Works\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eWhen control voltage is applied to the shunt trip terminals, the internal electromagnetic coil activates and mechanically trips the connected circuit breaker. This allows safe and automatic power disconnection during emergencies such as fire alarms, overload signals, or system faults.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIt is an essential component in modern electrical safety and automation systems.\u003c\/p\u003e\n\u003ch2 class=\"MsoNormal\"\u003e\u003cb\u003eWhy Choose CNC Electric Shunt Trip?\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003eCNC Electric products are globally recognized for high reliability, advanced protection technology, and durable electrical accessories. This shunt trip module ensures:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eEnhanced electrical protection\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eQuick emergency response\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eSafe remote breaker control\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eLong operational life\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo2; tab-stops: list .5in;\"\u003eIndustrial-grade performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003ePerfect for electricians, panel builders, solar installers, and industrial engineers looking for reliable circuit breaker accessories. For over and under voltage protection, add a \u003ca href=\"\/collections\/voltage-protectors\" style=\"color:#d42027\"\u003evoltage protector\u003c\/a\u003e to your board.\u003c\/p\u003e\n\u003cdiv style=\"margin-top:15px;font-size:14px\"\u003e\n\u003cstrong\u003e📖 Related Guides:\u003c\/strong\u003e\u003cul style=\"padding-left:18px;margin-top:5px\"\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/news\/ac-mccb-breaker-complete-guide-to-moulded-case-circuit-breaker-features-applications\" style=\"color:#d42027\"\u003eMCCB Breaker Complete Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guides\/mcb-full-form-what-is-mcb-miniature-circuit-breaker-working-principle-types\" style=\"color:#d42027\"\u003eMCB vs MCCB vs ACB Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"CNC Electric Pakistan","offers":[{"title":"100A","offer_id":43011120988226,"sku":null,"price":1400.0,"currency_code":"PKR","in_stock":false},{"title":"125A","offer_id":43011121020994,"sku":null,"price":1400.0,"currency_code":"PKR","in_stock":true},{"title":"160A","offer_id":43011121053762,"sku":null,"price":1400.0,"currency_code":"PKR","in_stock":true},{"title":"200A","offer_id":43011121086530,"sku":null,"price":1900.0,"currency_code":"PKR","in_stock":true},{"title":"250A","offer_id":43011121119298,"sku":null,"price":1900.0,"currency_code":"PKR","in_stock":true},{"title":"400A","offer_id":43011121152066,"sku":null,"price":4300.0,"currency_code":"PKR","in_stock":true},{"title":"630A","offer_id":43011121184834,"sku":null,"price":4300.0,"currency_code":"PKR","in_stock":true},{"title":"800A","offer_id":43011121217602,"sku":null,"price":4300.0,"currency_code":"PKR","in_stock":true},{"title":"1000A","offer_id":43011121250370,"sku":null,"price":4300.0,"currency_code":"PKR","in_stock":true},{"title":"1250A","offer_id":43011121283138,"sku":null,"price":4300.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/2059\/5522\/files\/Shunt_Trip_Release_for_MCB_MCCB.webp?v=1771497446"}],"url":"https:\/\/www.cncelectric.pk\/collections\/circuit-breakers.oembed?page=2","provider":"CNC Electric Pakistan","version":"1.0","type":"link"}